33 resultados para Enterprise Resource Planning System

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Late toxicities such as second cancer induction become more important as treatment outcome improves. Often the dose distribution calculated with a commercial treatment planning system (TPS) is used to estimate radiation carcinogenesis for the radiotherapy patient. However, for locations beyond the treatment field borders, the accuracy is not well known. The aim of this study was to perform detailed out-of-field-measurements for a typical radiotherapy treatment plan administered with a Cyberknife and a Tomotherapy machine and to compare the measurements to the predictions of the TPS. MATERIALS AND METHODS: Individually calibrated thermoluminescent dosimeters were used to measure absorbed dose in an anthropomorphic phantom at 184 locations. The measured dose distributions from 6 MV intensity-modulated treatment beams for CyberKnife and TomoTherapy machines were compared to the dose calculations from the TPS. RESULTS: The TPS are underestimating the dose far away from the target volume. Quantitatively the Cyberknife underestimates the dose at 40cm from the PTV border by a factor of 60, the Tomotherapy TPS by a factor of two. If a 50% dose uncertainty is accepted, the Cyberknife TPS can predict doses down to approximately 10 mGy/treatment Gy, the Tomotherapy-TPS down to 0.75 mGy/treatment Gy. The Cyberknife TPS can then be used up to 10cm from the PTV border the Tomotherapy up to 35cm. CONCLUSIONS: We determined that the Cyberknife and Tomotherapy TPS underestimate substantially the doses far away from the treated volume. It is recommended not to use out-of-field doses from the Cyberknife TPS for applications like modeling of second cancer induction. The Tomotherapy TPS can be used up to 35cm from the PTV border (for a 390 cm(3) large PTV).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AbstractBreast cancer is one of the most common cancers affecting one in eight women during their lives. Survival rates have increased steadily thanks to early diagnosis with mammography screening and more efficient treatment strategies. Post-operative radiation therapy is a standard of care in the management of breast cancer and has been shown to reduce efficiently both local recurrence rate and breast cancer mortality. Radiation therapy is however associated with some late effects for long-term survivors. Radiation-induced secondary cancer is a relatively rare but severe late effect of radiation therapy. Currently, radiotherapy plans are essentially optimized to maximize tumor control and minimize late deterministic effects (tissue reactions) that are mainly associated with high doses (» 1 Gy). With improved cure rates and new radiation therapy technologies, it is also important to evaluate and minimize secondary cancer risks for different treatment techniques. This is a particularly challenging task due to the large uncertainties in the dose-response relationship.In contrast with late deterministic effects, secondary cancers may be associated with much lower doses and therefore out-of-field doses (also called peripheral doses) that are typically inferior to 1 Gy need to be determined accurately. Out-of-field doses result from patient scatter and head scatter from the treatment unit. These doses are particularly challenging to compute and we characterized it by Monte Carlo (MC) calculation. A detailed MC model of the Siemens Primus linear accelerator has been thoroughly validated with measurements. We investigated the accuracy of such a model for retrospective dosimetry in epidemiological studies on secondary cancers. Considering that patients in such large studies could be treated on a variety of machines, we assessed the uncertainty in reconstructed peripheral dose due to the variability of peripheral dose among various linac geometries. For large open fields (> 10x10 cm2), the uncertainty would be less than 50%, but for small fields and wedged fields the uncertainty in reconstructed dose could rise up to a factor of 10. It was concluded that such a model could be used for conventional treatments using large open fields only.The MC model of the Siemens Primus linac was then used to compare out-of-field doses for different treatment techniques in a female whole-body CT-based phantom. Current techniques such as conformai wedged-based radiotherapy and hybrid IMRT were investigated and compared to older two-dimensional radiotherapy techniques. MC doses were also compared to those of a commercial Treatment Planning System (TPS). While the TPS is routinely used to determine the dose to the contralateral breast and the ipsilateral lung which are mostly out of the treatment fields, we have shown that these doses may be highly inaccurate depending on the treatment technique investigated. MC shows that hybrid IMRT is dosimetrically similar to three-dimensional wedge-based radiotherapy within the field, but offers substantially reduced doses to out-of-field healthy organs.Finally, many different approaches to risk estimations extracted from the literature were applied to the calculated MC dose distribution. Absolute risks varied substantially as did the ratio of risk between two treatment techniques, reflecting the large uncertainties involved with current risk models. Despite all these uncertainties, the hybrid IMRT investigated resulted in systematically lower cancer risks than any of the other treatment techniques. More epidemiological studies with accurate dosimetry are required in the future to construct robust risk models. In the meantime, any treatment strategy that reduces out-of-field doses to healthy organs should be investigated. Electron radiotherapy might offer interesting possibilities with this regard.RésuméLe cancer du sein affecte une femme sur huit au cours de sa vie. Grâce au dépistage précoce et à des thérapies de plus en plus efficaces, le taux de guérison a augmenté au cours du temps. La radiothérapie postopératoire joue un rôle important dans le traitement du cancer du sein en réduisant le taux de récidive et la mortalité. Malheureusement, la radiothérapie peut aussi induire des toxicités tardives chez les patients guéris. En particulier, les cancers secondaires radio-induits sont une complication rare mais sévère de la radiothérapie. En routine clinique, les plans de radiothérapie sont essentiellement optimisées pour un contrôle local le plus élevé possible tout en minimisant les réactions tissulaires tardives qui sont essentiellement associées avec des hautes doses (» 1 Gy). Toutefois, avec l'introduction de différentes nouvelles techniques et avec l'augmentation des taux de survie, il devient impératif d'évaluer et de minimiser les risques de cancer secondaire pour différentes techniques de traitement. Une telle évaluation du risque est une tâche ardue étant donné les nombreuses incertitudes liées à la relation dose-risque.Contrairement aux effets tissulaires, les cancers secondaires peuvent aussi être induits par des basses doses dans des organes qui se trouvent hors des champs d'irradiation. Ces organes reçoivent des doses périphériques typiquement inférieures à 1 Gy qui résultent du diffusé du patient et du diffusé de l'accélérateur. Ces doses sont difficiles à calculer précisément, mais les algorithmes Monte Carlo (MC) permettent de les estimer avec une bonne précision. Un modèle MC détaillé de l'accélérateur Primus de Siemens a été élaboré et validé avec des mesures. La précision de ce modèle a également été déterminée pour la reconstruction de dose en épidémiologie. Si on considère que les patients inclus dans de larges cohortes sont traités sur une variété de machines, l'incertitude dans la reconstruction de dose périphérique a été étudiée en fonction de la variabilité de la dose périphérique pour différents types d'accélérateurs. Pour de grands champs (> 10x10 cm ), l'incertitude est inférieure à 50%, mais pour de petits champs et des champs filtrés, l'incertitude de la dose peut monter jusqu'à un facteur 10. En conclusion, un tel modèle ne peut être utilisé que pour les traitements conventionnels utilisant des grands champs.Le modèle MC de l'accélérateur Primus a été utilisé ensuite pour déterminer la dose périphérique pour différentes techniques dans un fantôme corps entier basé sur des coupes CT d'une patiente. Les techniques actuelles utilisant des champs filtrés ou encore l'IMRT hybride ont été étudiées et comparées par rapport aux techniques plus anciennes. Les doses calculées par MC ont été comparées à celles obtenues d'un logiciel de planification commercial (TPS). Alors que le TPS est utilisé en routine pour déterminer la dose au sein contralatéral et au poumon ipsilatéral qui sont principalement hors des faisceaux, nous avons montré que ces doses peuvent être plus ou moins précises selon la technTque étudiée. Les calculs MC montrent que la technique IMRT est dosimétriquement équivalente à celle basée sur des champs filtrés à l'intérieur des champs de traitement, mais offre une réduction importante de la dose aux organes périphériques.Finalement différents modèles de risque ont été étudiés sur la base des distributions de dose calculées par MC. Les risques absolus et le rapport des risques entre deux techniques de traitement varient grandement, ce qui reflète les grandes incertitudes liées aux différents modèles de risque. Malgré ces incertitudes, on a pu montrer que la technique IMRT offrait une réduction du risque systématique par rapport aux autres techniques. En attendant des données épidémiologiques supplémentaires sur la relation dose-risque, toute technique offrant une réduction des doses périphériques aux organes sains mérite d'être étudiée. La radiothérapie avec des électrons offre à ce titre des possibilités intéressantes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To make a comprehensive evaluation of organ-specific out-of-field doses using Monte Carlo (MC) simulations for different breast cancer irradiation techniques and to compare results with a commercial treatment planning system (TPS). Three breast radiotherapy techniques using 6MV tangential photon beams were compared: (a) 2DRT (open rectangular fields), (b) 3DCRT (conformal wedged fields), and (c) hybrid IMRT (open conformal+modulated fields). Over 35 organs were contoured in a whole-body CT scan and organ-specific dose distributions were determined with MC and the TPS. Large differences in out-of-field doses were observed between MC and TPS calculations, even for organs close to the target volume such as the heart, the lungs and the contralateral breast (up to 70% difference). MC simulations showed that a large fraction of the out-of-field dose comes from the out-of-field head scatter fluence (>40%) which is not adequately modeled by the TPS. Based on MC simulations, the 3DCRT technique using external wedges yielded significantly higher doses (up to a factor 4-5 in the pelvis) than the 2DRT and the hybrid IMRT techniques which yielded similar out-of-field doses. In sharp contrast to popular belief, the IMRT technique investigated here does not increase the out-of-field dose compared to conventional techniques and may offer the most optimal plan. The 3DCRT technique with external wedges yields the largest out-of-field doses. For accurate out-of-field dose assessment, a commercial TPS should not be used, even for organs near the target volume (contralateral breast, lungs, heart).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: To report a single-center experience in 19 patients (pts) with anal canal cancer treated with helical tomotherapy (HT) and concurrent chemotherapy, and compare the dosimetric results with fixed-field intensitymodulated radiotherapy (IMRT) and 3D conformal radiotherapy (3D RT). Materials and Methods: Between 2007 and 2008, 19 consecutive pts were treated with HT and concurrent CT for anal canal cancer. Median age was 59 years (range, 38−83), and female/male ratio was 14/5. The majority of the pts had T2 or T3 tumours (68.4%), and 52.6% had positive lymph nodes. In all 19 pts, pelvic and inguinal nodes, and tumour irradiation was given using HT upto a median dose of 36 Gy (1.8 Gy/fr) followed by a 1-week gap. A boost dose of 23.4 Gy (1.8 Gy/fr) was delivered to the tumour and involved nodes using 3DRT (n = 12), HT (n = 6), or IMRT (n = 1). Simultaneous integrated boost was used in none of the pts. All but one patient with a T1N0 tumour received concomitant mitomycin/5- fluorouracil (n = 12) or mitomycin/capecitabin (n = 7) CT. Toxicity was scored according to the Common Terminology Criteria for Adverse Events (NCICTCAE v3.0). HT plans and treatments were generated using Tomotherapy, Inc., software and hardware; and 3D or IMRT boost plans with the CMS treatment planning system (TPS), using 6−18 MV photons from a Siemens Primus accelerator. For dosimetric comparison, computed tomography data sets of 10 pts were imported into the TPS, and 3D and 5-field step-andshoot IMRT plans were generated for each case. Plans were optimized with the aim of assessing organs at risk (OAR) and healthy-tissue sparing while enforcing highly conformal target coverage, and evaluated by dose-volume histograms (DVH) of planning target volumes (PTV) and OAR. Results: With a median follow-up of 13 months (range, 3−18), all pts are alive and well; except one patient developing local recurrence at 12 months. No patient developed grade 3 or more acute toxicity. No unplanned treatment interruption was necessary because of toxicity. With 360-degree-of-freedom beam projection, HT showed an advantage over 3D or IMRT plans in terms of dose conformity around the PTV, and dose gradients were steeper outside the PTV, resulting in reduced doses to OARs. Using HT, acute toxicity was acceptable, and seemed to be better than historical standards. Conclusion: We conclude that HT combined with concurrent chemotherapy for anal canal cancer is effective and tolerable. Compared to 3DRT or 5-field IMRT, there is better conformity around the PTV, and OAR sparing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Intensity-modulated radiotherapy (IMRT) treatment plan verification by comparison with measured data requires having access to the linear accelerator and is time consuming. In this paper, we propose a method for monitor unit (MU) calculation and plan comparison for step and shoot IMRT based on the Monte Carlo code EGSnrc/BEAMnrc. The beamlets of an IMRT treatment plan are individually simulated using Monte Carlo and converted into absorbed dose to water per MU. The dose of the whole treatment can be expressed through a linear matrix equation of the MU and dose per MU of every beamlet. Due to the positivity of the absorbed dose and MU values, this equation is solved for the MU values using a non-negative least-squares fit optimization algorithm (NNLS). The Monte Carlo plan is formed by multiplying the Monte Carlo absorbed dose to water per MU with the Monte Carlo/NNLS MU. Several treatment plan localizations calculated with a commercial treatment planning system (TPS) are compared with the proposed method for validation. The Monte Carlo/NNLS MUs are close to the ones calculated by the TPS and lead to a treatment dose distribution which is clinically equivalent to the one calculated by the TPS. This procedure can be used as an IMRT QA and further development could allow this technique to be used for other radiotherapy techniques like tomotherapy or volumetric modulated arc therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Radiosurgery (RS) is gaining increasing acceptance in the upfront management of brain metastases (BM). It was initially used in so-called radioresistant metastases (melanoma, renal cell, sarcoma) because it allowed delivering higher dose to the tumor. Now, RS is also used for BM of other cancers. The risk of high incidence of new BM questions the need for associated whole-brain radiotherapy (WBRT). Recent evidence suggests that RS alone allows avoiding cognitive impairment related to WBRT, and the latter should be upheld for salvage therapy. Thus the increase use of RS for single and multiple BM raises new technical challenges for treatment delivery and dosimetry. We present our single institution experience focusing on the criteria that led to patients' selection for RS treatment with Gamma Knife (GK) in lieu of Linac. METHODS: Leksell Gamma Knife Perfexion (Elekta, Sweden) was installed in July 2010. Currently, the Swiss federal health care supports the costs of RS for BM with Linac but not with GK. Therefore, in our center, we always consider first the possibility to use Linac for this indication, and only select patients for GK in specific situations. All cases of BM treated with GK were retrospectively reviewed for criteria yielding to GK indication, clinical information, and treatment data. Further work in progress includes a posteriori dosimetry comparison with our Linac planning system (Brainscan V.5.3, Brainlab, Germany). RESULTS: From July 2010 to March 2012, 20 patients had RS for BM with GK (7 patients with single BM, and 13 with multiple BM). During the same period, 31 had Linac-based RS. Primary tumor was melanoma in 9, lung in 7, renal in 2, and gastrointestinal tract in 2 patients. In single BM, the reason for choosing of GK was the anatomical location close to, or in highly functional areas (1 motor cortex, 1 thalamic, 1 ventricular, 1 mesio-temporal, 3 deep cerebellar close to the brainstem), especially since most of these tumors were intended to be treated with high-dose RS (24 Gy at margin) because of their histology (3 melanomas, 1 renal cell). In multiple BM, the reason for choosing GK in relation with the anatomical location of the lesions was either technical (limitations of Linac movements, especially in lower posterior fossa locations) or closeness of multiple lesions to highly functional areas (typically, multiple posterior fossa BM close to the brainstem), precluding optimal dosimetry with Linac. Again, this was made more critical for multiple BM needing high-dose RS (6 melanoma, 2 hypernephroma). CONCLUSION: Radiosurgery for BM may represent some technical challenge in relation with the anatomical location and multiplicity of the lesions. These considerations may be accentuated for so-called radioresistant BM, when higher dose RS in needed. In our experience, Leksell Gamma Knife Perfexion proves to be useful in addressing these challenges for the treatment of BM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To report a single-center experience treating patients with squamous- cell carcinoma of the anal canal using helical Tomotherapy (HT) and concurrent chemotherapy (CT).Materials/Methods: From October 2007 to February 2011, 55 patients were treated with HT and concurrent CT (5-fluorouracil/capecitabin and mitomycin) for anal squamous-cell carcinoma. All patients underwent computed- tomography-based treatment planning, with pelvic and inguinal nodes receiving 36 Gy in 1.8 Gy/fraction. Following a planned 1-week break, primary tumor site and involved nodes were boosted to a total dose 59.4 Gy in 1.8 Gy/fraction. Dose-volume histograms of several organs at risk (OAR; bladder, small intestine, rectum, femoral heads, penile bulb, external genitalia) were assessed in terms of conformal avoidance. All toxicity was scored according to the CTCAE, v.3.0. HT plans and treatment were implemented using the Tomotherapy, Inc. software and hardware. For dosimetric comparisons, 3D RT and/or IMRT plans were also computed for some of the patients using the CMS planning system, for treatment with 6-18 MV photons and/or electrons with suitable energies from a Siemens Primus linear accelerator equipped with a multileaf collimator.Locoregional control and survival curves were compared with the log-rank test, and multivariate analysis by the Cox model.Results: With 360-degree-of-freedom beam projection, HT has an advantage over other RT techniques (3D or 5-field step-and-shot IMRT). There is significant improvement over 3D or 5-field IMRT plans in terms of dose conformity around the PTV, and dose gradients are steeper outside the target volume, resulting in reduced doses to OARs. Using HT, acute toxicity was acceptable, and seemed to be better than historical standards.Conclusions: Our results suggest that HT combined with concurrent CT for anal cancer is effective and tolerable. Compared to 3D RT or 5-field step-andshot IMRT, there is better conformity around the PTV, and better OAR sparing.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Summary Forests are key ecosystems of the earth and associated with a large range of functions. Many of these functions are beneficial to humans and are referred to as ecosystem services. Sustainable development requires that all relevant ecosystem services are quantified, managed and monitored equally. Natural resource management therefore targets the services associated with ecosystems. The main hypothesis of this thesis is that the spatial and temporal domains of relevant services do not correspond to a discrete forest ecosystem. As a consequence, the services are not quantified, managed and monitored in an equal and sustainable manner. The thesis aims were therefore to test this hypothesis, establish an improved conceptual approach and provide spatial applications for the relevant land cover and structure variables. The study was carried out in western Switzerland and based primarily on data from a countrywide landscape inventory. This inventory is part of the third Swiss national forest inventory and assesses continuous landscape variables based on a regular sampling of true colour aerial imagery. In addition, land cover variables were derived from Landsat 5 TM passive sensor data and land structure variables from active sensor data from a small footprint laserscanning system. The results confirmed the main hypothesis, as relevant services did not scale well with the forest ecosystem. Instead, a new conceptual approach for sustainable management of natural resources was described. This concept quantifies the services as a continuous function of the landscape, rather than a discrete function of the forest ecosystem. The explanatory landscape variables are therefore called continuous fields and the forest becomes a dependent and function-driven management unit. Continuous field mapping methods were established for land cover and structure variables. In conclusion, the discrete forest ecosystem is an adequate planning and management unit. However, monitoring the state of and trends in sustainability of services requires them to be quantified as a continuous function of the landscape. Sustainable natural resource management iteratively combines the ecosystem and gradient approaches. Résumé Les forêts sont des écosystèmes-clés de la terre et on leur attribue un grand nombre de fonctions. Beaucoup de ces fonctions sont bénéfiques pour l'homme et sont nommées services écosystémiques. Le développement durable exige que ces services écosystémiques soient tous quantifiés, gérés et surveillés de façon égale. La gestion des ressources naturelles a donc pour cible les services attribués aux écosystèmes. L'hypothèse principale de cette thèse est que les domaines spatiaux et temporels des services attribués à la forêt ne correspondent pas à un écosystème discret. Par conséquent, les services ne sont pas quantifiés, aménagés et surveillés d'une manière équivalente et durable. Les buts de la thèse étaient de tester cette hypothèse, d'établir une nouvelle approche conceptuelle de la gestion des ressources naturelles et de préparer des applications spatiales pour les variables paysagères et structurelles appropriées. L'étude a été menée en Suisse occidentale principalement sur la base d'un inventaire de paysage à l'échelon national. Cet inventaire fait partie du troisième inventaire forestier national suisse et mesure de façon continue des variables paysagères sur la base d'un échantillonnage régulier sur des photos aériennes couleur. En outre, des variables de couverture ? terrestre ont été dérivées des données d'un senseur passif Landsat 5 TM, ainsi que des variables structurelles, dérivées du laserscanning, un senseur actif. Les résultats confirment l'hypothèse principale, car l'échelle des services ne correspond pas à celle de l'écosystème forestier. Au lieu de cela, une nouvelle approche a été élaborée pour la gestion durable des ressources naturelles. Ce concept représente les services comme une fonction continue du paysage, plutôt qu'une fonction discrète de l'écosystème forestier. En conséquence, les variables explicatives de paysage sont dénommées continuous fields et la forêt devient une entité dépendante, définie par la fonction principale du paysage. Des méthodes correspondantes pour la couverture terrestre et la structure ont été élaborées. En conclusion, l'écosystème forestier discret est une unité adéquate pour la planification et la gestion. En revanche, la surveillance de la durabilité de l'état et de son évolution exige que les services soient quantifiés comme fonction continue du paysage. La gestion durable des ressources naturelles joint donc l'approche écosystémique avec celle du gradient de manière itérative.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Type 2 diabetes mellitus (T2DM) is a major disease affecting nearly 280 million people worldwide. Whilst the pathophysiological mechanisms leading to disease are poorly understood, dysfunction of the insulin-producing pancreatic beta-cells is key event for disease development. Monitoring the gene expression profiles of pancreatic beta-cells under several genetic or chemical perturbations has shed light on genes and pathways involved in T2DM. The EuroDia database has been established to build a unique collection of gene expression measurements performed on beta-cells of three organisms, namely human, mouse and rat. The Gene Expression Data Analysis Interface (GEDAI) has been developed to support this database. The quality of each dataset is assessed by a series of quality control procedures to detect putative hybridization outliers. The system integrates a web interface to several standard analysis functions from R/Bioconductor to identify differentially expressed genes and pathways. It also allows the combination of multiple experiments performed on different array platforms of the same technology. The design of this system enables each user to rapidly design a custom analysis pipeline and thus produce their own list of genes and pathways. Raw and normalized data can be downloaded for each experiment. The flexible engine of this database (GEDAI) is currently used to handle gene expression data from several laboratory-run projects dealing with different organisms and platforms. Database URL: http://eurodia.vital-it.ch.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Plasmacytoid dendritic cells (pDCs) were first described as interferon-producing cells and, for many years, their overlapping characteristics with both lymphocytes and classical dendritic cells (cDCs) created confusion over their exact ontogeny. In this Viewpoint article, Nature Reviews Immunology asks five leaders in the field to discuss their thoughts on the development and functions of pDCs--do these cells serve mainly as a major source of type I interferons or do they also make other important contributions to immune responses?

Relevância:

30.00% 30.00%

Publicador:

Resumo:

1. The mechanisms underlying host choice strategies by parasites remain poorly understood. We address two main questions: (i) do parasites prefer vulnerable or well-fed hosts, and (ii) to what extent is a parasite species specialized towards a given host species? 2. To answer these questions, we investigated, both in the field and in the lab, a host-parasite system comprising one ectoparasitic mite (Spinturnix myoti) and its major hosts, two sibling species of bats (Myotis myotis and M blythii), which coexist intimately in colonial nursery roosts. We exploited the close physical associations between host species in colonial roosts as well as naturally occurring annual variation in food abundance to investigate the relationships between parasite intensities and (i) host species and (ii) individual nutritional status. 3. Although horizontal transmission of parasites was facilitated by the intimate aggregation of bats within their colonial clusters, we found significant interspecific differences in degree of infestation throughout the 6 years of the study, with M. myotis always more heavily parasitized than M. blythii. This pattern was replicated in a laboratory experiment in which any species-specific resistance induced by exploitation of different trophic niches in nature was removed. 4. Within both host species, S. myoti showed a clear preference for individuals with higher nutritional status. In years with high resource abundance, both bat hosts harboured more parasites than in low-resource years, although the relative difference in parasite burden across species was maintained. This pattern of host choice was also replicated in the laboratory. When offered a choice, parasites always colonized better-fed individuals. 5. These results show first that host specialization in our study system occurred. Second, immediate parasite choice clearly operated towards the selection of hosts in good nutritional state.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective Activation of the renal renin-angiotensin system in patients with diabetes mellitus appears to contribute to the risk of nephropathy. Recently, it has been recognized than an elevation of prorenin in plasma also provides a strong indication of risk of nephropathy. This study was designed to examine renin-angiotensin system control mechanisms in the patient with diabetes mellitus.Methods We enrolled 43 individuals with type 2 diabetes mellitus. All individuals were on a high-salt diet to minimize the contribution of the systemic renin-angiotensin system. After an acute exposure to captopril (25 mg), they were randomized to treatment with either irbesartan (300 mg) or aliskiren (300 mg) for 2 weeks.Results All agents acutely lowered blood pressure and plasma aldosterone, and increased renal plasma flow and glomerular filtration rate. Yet, only captopril and aliskiren acutely increased plasma renin and decreased plasma angiotensin II, whereas irbesartan acutely affected neither renin nor angiotensin II. Plasma renin and angiotensin II subsequently did increase upon chronic irbesartan treatment. When given on day 14, irbesartan and aliskiren again induced the above hemodynamic, renal and adrenal effects, yet without significantly changing plasma renin. Irbesartan at that time did not affect plasma angiotensin II, whereas aliskiren lowered it to almost zero.Conclusion The relative resistance of the renal renin response to acute (irbesartan) and chronic (irbesartan and aliskiren) renin-angiotensin system blockade supports the concept of an activated renal renin-angiotensin system in diabetes, particularly at the level of the juxtaglomerular cell, and implies that diabetic patients might require higher doses of renin-angiotensin system blockers to fully suppress the renal renin-angiotensin system. J Hypertens 29: 2454-2461 (C) 2011 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The MyHits web server (http://myhits.isb-sib.ch) is a new integrated service dedicated to the annotation of protein sequences and to the analysis of their domains and signatures. Guest users can use the system anonymously, with full access to (i) standard bioinformatics programs (e.g. PSI-BLAST, ClustalW, T-Coffee, Jalview); (ii) a large number of protein sequence databases, including standard (Swiss-Prot, TrEMBL) and locally developed databases (splice variants); (iii) databases of protein motifs (Prosite, Interpro); (iv) a precomputed list of matches ('hits') between the sequence and motif databases. All databases are updated on a weekly basis and the hit list is kept up to date incrementally. The MyHits server also includes a new collection of tools to generate graphical representations of pairwise and multiple sequence alignments including their annotated features. Free registration enables users to upload their own sequences and motifs to private databases. These are then made available through the same web interface and the same set of analytical tools. Registered users can manage their own sequences and annotations using only web tools and freeze their data in their private database for publication purposes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

QUESTION UNDER STUDY: Thirty-day readmissions can be classified as potentially avoidable (PARs) or not avoidable (NARs) by following a specific algorithm (SQLape®). We wanted to assess the financial impact of the Swiss-DRG system, which regroups some readmissions occurring within 18 days after discharge within the initial hospital stay, on PARs at our hospital. METHODS: First, PARs were identified from all hospitalisations recorded in 2011 at our university hospital. Second, 2012 Swiss-DRG readmission rules were applied, regrouped readmissions (RR) were identified, and their financial impact computed. Third, RRs were classified as potentially avoidable (PARRs), not avoidable (NARRs), and others causes (OCRRs). Characteristics of PARR patients and stays were retrieved, and the financial impact of PARRS was computed. RESULTS: A total of 36,777 hospitalisations were recorded in 2011, of which 3,140 were considered as readmissions (8.5%): 1,470 PARs (46.8%) and 1,733 NARs (53.2%). The 2012 Swiss-DRG rules would have resulted in 910 RRs (2.5% of hospitalisations, 29% of readmissions): 395 PARRs (43% of RR), 181 NARRs (20%), and 334 OCRRs (37%). Loss in reimbursement would have amounted to CHF 3.157 million (0.6% of total reimbursement). As many as 95% of the 395 PARR patients lived at home. In total, 28% of PARRs occurred within 3 days after discharge, and 58% lasted less than 5 days; 79% of the patients were discharged home again. Loss in reimbursement would amount to CHF 1.771 million. CONCLUSION: PARs represent a sizeable number of 30-day readmissions, as do PARRs of 18-day RRs in the 2012 Swiss DRG system. They should be the focus of attention, as the PARRs represent an avoidable loss in reimbursement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a method based on a geographical information system (GIS) to model ecological networks in a fragmented landscape. The ecological networks are generated with the help of a landscape model (which integrate human activities) and with a wildlife dispersal model. The main results are maps which permit the analysis and the understanding of the impact of human activities on wildlife dispersal. Three applications in a study area are presented: ecological networks at the landscape scale, conflicting areas at the farmstead scale and ecological distance between biotopes. These applications show the flexibility of the model and its potential to give information on ecological networks at different planning scales.