12 resultados para Energy quality
em Université de Lausanne, Switzerland
Resumo:
In European countries and North America, people spend 80 to 90% of time inside buildings and thus breathe indoor air. In Switzerland, special attention has been devoted to the 16 stations of the national network of observation of atmospheric pollutants (NABEL). The results indicate a reduction in outdoor pollution over the last ten years. With such a decrease in pollution over these ten years the question becomes: how can we explain an increase of diseases? Indoor pollution can be the cause. Indoor contaminants that may create indoor air quality (IAQ) problems come from a variety of sources. These can include inadequate ventilation, temperature and humidity dysfunction, and volatile organic compounds (VOCs). The health effects from these contaminants are varied and can range from discomfort, irritation and respiratory diseases to cancer. Among such contaminants, environmental tobacco smoke (ETS) could be considered the most important in terms of both health effects and engineering controls of ventilation. To perform indoor pollution monitoring, several selected ETS tracers can be used including carbon monoxide (CO), carbon dioxide (CO2), respirable particles (RSP), condensate, nicotine, polycyclic aromatic hydrocarbons (PAHs), nitrosamines, etc. In this paper, some examples are presented of IAQ problems that have occurred following the renewal of buildings and energy saving concerns. Using industrial hygiene sampling techniques and focussing on selected priority pollutants used as tracers, various problems have been identified and solutions proposed. [Author]
Resumo:
OBJECTIVE: Critically ill patients are at high risk of malnutrition. Insufficient nutritional support still remains a widespread problem despite guidelines. The aim of this study was to measure the clinical impact of a two-step interdisciplinary quality nutrition program. DESIGN: Prospective interventional study over three periods (A, baseline; B and C, intervention periods). SETTING: Mixed intensive care unit within a university hospital. PATIENTS: Five hundred seventy-two patients (age 59 ± 17 yrs) requiring >72 hrs of intensive care unit treatment. INTERVENTION: Two-step quality program: 1) bottom-up implementation of feeding guideline; and 2) additional presence of an intensive care unit dietitian. The nutrition protocol was based on the European guidelines. MEASUREMENTS AND MAIN RESULTS: Anthropometric data, intensive care unit severity scores, energy delivery, and cumulated energy balance (daily, day 7, and discharge), feeding route (enteral, parenteral, combined, none-oral), length of intensive care unit and hospital stay, and mortality were collected. Altogether 5800 intensive care unit days were analyzed. Patients in period A were healthier with lower Simplified Acute Physiologic Scale and proportion of "rapidly fatal" McCabe scores. Energy delivery and balance increased gradually: impact was particularly marked on cumulated energy deficit on day 7 which improved from -5870 kcal to -3950 kcal (p < .001). Feeding technique changed significantly with progressive increase of days with nutrition therapy (A: 59% days, B: 69%, C: 71%, p < .001), use of enteral nutrition increased from A to B (stable in C), and days on combined and parenteral nutrition increased progressively. Oral energy intakes were low (mean: 385 kcal*day, 6 kcal*kg*day ). Hospital mortality increased with severity of condition in periods B and C. CONCLUSION: A bottom-up protocol improved nutritional support. The presence of the intensive care unit dietitian provided significant additional progression, which were related to early introduction and route of feeding, and which achieved overall better early energy balance.
Resumo:
BACKGROUND: Protein-energy wasting is a frequent and debilitating condition in maintenance dialysis. We randomly tested if an energy-dense, phosphate-restricted, renal-specific oral supplement could maintain adequate nutritional intake and prevent malnutrition in maintenance haemodialysis patients with insufficient intake. METHODS: Eighty-six patients were assigned to a standard care (CTRL) group or were prescribed two 125-ml packs of Renilon 7.5(R) daily for 3 months (SUPP). Dietary intake, serum (S) albumin, prealbumin, protein nitrogen appearance (nPNA), C-reactive protein, subjective global assessment (SGA) and quality of life (QOL) were recorded at baseline and after 3 months. RESULTS: While intention to treat analysis (ITT) did not reveal strong statistically significant changes in dietary intake between groups, per protocol (PP) analysis showed that the SUPP group increased protein (P < 0.01) and energy (P < 0.01) intakes. In contrast, protein and energy intakes further deteriorated in the CTRL group (PP). Although there was no difference in serum albumin and prealbumin changes between groups, in the total population serum albumin and prealbumin changes were positively associated with the increment in protein intake (r = 0.29, P = 0.01 and r = 0.27, P = 0.02, respectively). The SUPP group did not increase phosphate intake, phosphataemia remained unaffected, and the use of phosphate binders remained stable or decreased. The SUPP group exhibited improved SGA and QOL (P < 0.05). CONCLUSION: This study shows that providing maintenance haemodialysis patients with insufficient intake with a renal-specific oral supplement may prevent deterioration in nutritional indices and QOL without increasing the need for phosphate binders.
Resumo:
INTRODUCTION: The phase III EORTC 22033-26033/NCIC CE5 intergroup trial compares 50.4 Gy radiotherapy with up-front temozolomide in previously untreated low-grade glioma. We describe the digital EORTC individual case review (ICR) performed to evaluate protocol radiotherapy (RT) compliance. METHODS: Fifty-eight institutions were asked to submit 1-2 randomly selected cases. Digital ICR datasets were uploaded to the EORTC server and accessed by three central reviewers. Twenty-seven parameters were analysed including volume delineation, treatment planning, organ at risk (OAR) dosimetry and verification. Consensus reviews were collated and summary statistics calculated. RESULTS: Fifty-seven of seventy-two requested datasets from forty-eight institutions were technically usable. 31/57 received a major deviation for at least one section. Relocation accuracy was according to protocol in 45. Just over 30% had acceptable target volumes. OAR contours were missing in an average of 25% of cases. Up to one-third of those present were incorrectly drawn while dosimetry was largely protocol compliant. Beam energy was acceptable in 97% and 48 patients had per protocol beam arrangements. CONCLUSIONS: Digital RT plan submission and review within the EORTC 22033-26033 ICR provide a solid foundation for future quality assurance procedures. Strict evaluation resulted in overall grades of minor and major deviation for 37% and 32%, respectively.
Resumo:
The shape of the energy spectrum produced by an x-ray tube has a great importance in mammography. Many anode-filtration combinations have been proposed to obtain the most effective spectrum shape for the image quality-dose relationship. On the other hand, third generation synchrotrons such as the European Synchrotron Radiation Facility in Grenoble are able to produce a high flux of monoenergetic radiation. It is thus a powerful tool to study the effect of beam energy on image quality and dose in mammography. An objective method was used to evaluate image quality and dose in mammography with synchrotron radiation and to compare them to standard conventional units. It was performed systematically in the energy range of interest for mammography through the evaluation of a global image quality index and through the measurement of the mean glandular dose. Compared to conventional mammography units, synchrotron radiation shows a great improvement of the image quality-dose relationship, which is due to the beam monochromaticity and to the high intrinsic collimation of the beam, which allows the use of a slit instead of an anti-scatter grid for scatter rejection.
Resumo:
Some years ago, a parish in Geneva decided to reduce heating costs by insulating its church to make it more energy efficient. Three years after the last renovations, it was observed that the internal surfaces of the naves had already become dusty compared with the customary frequency of 10-12 years. Dust even deposited on various surfaces during religious services. Our investigation showed that nearly all the dust found inside the church may in fact be soot from incense and candle combustion. Incense appears to be a significant source of polycyclic aromatic hydrocarbons. With a mechanical ventilation system and petrol lamps resembling candles the problem can be resolved.
Resumo:
INTRODUCTION: The influence of specific health problems on health-related quality of life (HRQoL) in childhood cancer survivors is unknown. We compared HRQoL between survivors of childhood cancer and their siblings, determined factors associated with HRQoL, and investigated the influence of chronic health problems on HRQoL. METHODS: Within the Swiss Childhood Cancer Survivor Study, we sent a questionnaire to all survivors (≥16 years) registered in the Swiss Childhood Cancer Registry, who survived >5 years and were diagnosed 1976-2005 aged <16 years. Siblings received similar questionnaires. We assessed HRQoL using Short Form-36 (SF-36). Health problems from a standard questionnaire were classified into overweight, vision impairment, hearing, memory, digestive, musculoskeletal or neurological, and thyroid problems. RESULTS: The sample included 1,593 survivors and 695 siblings. Survivors scored significantly lower than siblings in physical function, role limitation, general health, and the Physical Component Summary (PCS). Lower score in PCS was associated with a diagnosis of central nervous system tumor, retinoblastoma or bone tumor, having had surgery, cranio-spinal irradiation, or bone marrow transplantation. Lower score in Mental Component Summary was associated with older age. All health problems decreased HRQoL in all scales. Most affected were survivors reporting memory problems and musculoskeletal or neurological problems. Health problems had the biggest impact on physical functioning, general health, and energy and vitality. CONCLUSIONS: In this study, we showed the negative impact of specific chronic health problems on survivors' HRQoL. IMPLICATIONS FOR CANCER SURVIVORS: Therapeutic preventive measures, risk-targeted follow-up, and interventions might help decrease health problems and, consequently, improve survivors' quality of life.
Resumo:
Peripheral assessment of bone density using photon absorptiometry techniques has been available for over 40 yr. The initial use of radio-isotopes as the photon source has been replaced by the use of X-ray technology. A wide variety of models of single- or dual-energy X-ray measurement tools have been made available for purchase, although not all are still commercially available. The Official Positions of the International Society for Clinical Densitometry (ISCD) have been developed following a systematic review of the literature by an ISCD task force and a subsequent Position Development Conference. These cover the technological diversity among peripheral dual-energy X-ray absorptiometry (pDXA) devices; define whether pDXA can be used for fracture risk assessment and/or to diagnose osteoporosis; examine whether pDXA can be used to initiate treatment and/or monitor treatment; provide recommendations for pDXA reporting; and review quality assurance and quality control necessary for effective use of pDXA.
Resumo:
In mammography, the image contrast and dose delivered to the patient are determined by the x-ray spectrum and the scatter to primary ratio S/P. Thus the quality of the mammographic procedure is highly dependent on the choice of anode and filter material and on the method used to reduce the amount of scattered radiation reaching the detector. Synchrotron radiation is a useful tool to study the effect of beam energy on the optimization of the mammographic process because it delivers a high flux of monochromatic photons. Moreover, because the beam is naturally flat collimated in one direction, a slot can be used instead of a grid for scatter reduction. We have measured the ratio S/P and the transmission factors for grids and slots for monoenergetic synchrotron radiation. In this way the effect of beam energy and scatter rejection method were separated, and their respective importance for image quality and dose analyzed. Our results show that conventional mammographic spectra are not far from optimum and that the use of a slot instead of a grid has an important effect on the optimization of the mammographic process. We propose a simple numerical model to quantify this effect.
Resumo:
PURPOSE: EOS (EOS imaging S.A, Paris, France) is an x-ray imaging system that uses slot-scanning technology in order to optimize the trade-off between image quality and dose. The goal of this study was to characterize the EOS system in terms of occupational exposure, organ doses to patients as well as image quality for full spine examinations. METHODS: Occupational exposure was determined by measuring the ambient dose equivalents in the radiological room during a standard full spine examination. The patient dosimetry was performed using anthropomorphic phantoms representing an adolescent and a five-year-old child. The organ doses were measured with thermoluminescent detectors and then used to calculate effective doses. Patient exposure with EOS was then compared to dose levels reported for conventional radiological systems. Image quality was assessed in terms of spatial resolution and different noise contributions to evaluate the detector's performances of the system. The spatial-frequency signal transfer efficiency of the imaging system was quantified by the detective quantum efficiency (DQE). RESULTS: The use of a protective apron when the medical staff or parents have to stand near to the cubicle in the radiological room is recommended. The estimated effective dose to patients undergoing a full spine examination with the EOS system was 290μSv for an adult and 200 μSv for a child. MTF and NPS are nonisotropic, with higher values in the scanning direction; they are in addition energy-dependent, but scanning speed independent. The system was shown to be quantum-limited, with a maximum DQE of 13%. The relevance of the DQE for slot-scanning system has been addressed. CONCLUSIONS: As a summary, the estimated effective dose was 290μSv for an adult; the image quality remains comparable to conventional systems.
Resumo:
BACKGROUND: Enteral nutrition (EN) is recommended for patients in the intensive-care unit (ICU), but it does not consistently achieve nutritional goals. We assessed whether delivery of 100% of the energy target from days 4 to 8 in the ICU with EN plus supplemental parenteral nutrition (SPN) could optimise clinical outcome. METHODS: This randomised controlled trial was undertaken in two centres in Switzerland. We enrolled patients on day 3 of admission to the ICU who had received less than 60% of their energy target from EN, were expected to stay for longer than 5 days, and to survive for longer than 7 days. We calculated energy targets with indirect calorimetry on day 3, or if not possible, set targets as 25 and 30 kcal per kg of ideal bodyweight a day for women and men, respectively. Patients were randomly assigned (1:1) by a computer-generated randomisation sequence to receive EN or SPN. The primary outcome was occurrence of nosocomial infection after cessation of intervention (day 8), measured until end of follow-up (day 28), analysed by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00802503. FINDINGS: We randomly assigned 153 patients to SPN and 152 to EN. 30 patients discontinued before the study end. Mean energy delivery between day 4 and 8 was 28 kcal/kg per day (SD 5) for the SPN group (103% [SD 18%] of energy target), compared with 20 kcal/kg per day (7) for the EN group (77% [27%]). Between days 9 and 28, 41 (27%) of 153 patients in the SPN group had a nosocomial infection compared with 58 (38%) of 152 patients in the EN group (hazard ratio 0·65, 95% CI 0·43-0·97; p=0·0338), and the SPN group had a lower mean number of nosocomial infections per patient (-0·42 [-0·79 to -0·05]; p=0·0248). INTERPRETATION: Individually optimised energy supplementation with SPN starting 4 days after ICU admission could reduce nosocomial infections and should be considered as a strategy to improve clinical outcome in patients in the ICU for whom EN is insufficient. FUNDING: Foundation Nutrition 2000Plus, ICU Quality Funds, Baxter, and Fresenius Kabi.