2 resultados para Electrocardiography - Methods

em Université de Lausanne, Switzerland


Relevância:

60.00% 60.00%

Publicador:

Resumo:

QUESTION UNDER STUDY: Emergency room (ER) interpretation of the ECG is critical to assessment of patients with acute coronary syndromes (ACS). Our aim was to assess its reliability in our institution, a tertiary teaching hospital. METHODS: Over a 6-month period all consecutive patients admitted for ACS were included in the study. ECG interpretation by emergency physicians (EPs) was recorded on a preformatted sheet and compared with the interpretation of two specialist physicians (SPs). Discrepancies between the 2 specialists were resolved by an ECG specialist. RESULTS: Over the 6-month period, 692 consecutive patients were admitted with suspected ACS. ECG interpretation was available in 641 cases (93%). Concordance between SPs was 87%. Interpretation of normality or abnormality of the ECG was concordant between EPs and SPs in 475 cases (74%, kappa = 0.51). Interpretation of ischaemic modifications was concordant in 69% of cases, and as many ST segment elevations were unrecognised as overdiagnosed (5% each). The same findings occurred for ST segment depressions and negative T waves (12% each). CONCLUSIONS: Interpretation of the ECG recorded during ACS by 2 SPs was discrepant in 13% of cases. Similarly, EP interpretation was discrepant from SP interpretation in 25% of cases, equally distributed between over- and underdiagnosing of ischaemic changes. The clinical implications and impact of medical education on ECG interpretation require further study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently, morphometric measurements of the ascending aorta have been done with ECG-gated multidector computerized tomography (MDCT) to help the development of future novel transcatheter therapies (TCT); nevertheless, the variability of such measurements remains unknown. Thirty patients referred for ECG-gated CT thoracic angiography were evaluated. Continuous reformations of the ascending aorta, perpendicular to the centerline, were obtained automatically with a commercially available computer aided diagnosis (CAD). Then measurements of the maximal diameter were done with the CAD and manually by two observers (separately). Measurements were repeated one month later. The Bland-Altman method, Spearman coefficients, and a Wilcoxon signed-rank test were used to evaluate the variability, the correlation, and the differences between observers. The interobserver variability for maximal diameter between the two observers was up to 1.2 mm with limits of agreement [-1.5, +0.9] mm; whereas the intraobserver limits were [-1.2, +1.0] mm for the first observer and [-0.8, +0.8] mm for the second observer. The intraobserver CAD variability was 0.8 mm. The correlation was good between observers and the CAD (0.980-0.986); however, significant differences do exist (P<0.001). The maximum variability observed was 1.2 mm and should be considered in reports of measurements of the ascending aorta. The CAD is as reproducible as an experienced reader.