20 resultados para Electric current measurement
em Université de Lausanne, Switzerland
Resumo:
The major problems associated with the use of corticosteroids for the treatment of ocular diseases are their poor intraocular penetration to the posterior segment when administered locally and their secondary side effects when given systemically. To circumvent these problems more efficient methods and techniques of local delivery are being developed. The purposes of this study were: (1) to investigate the pharmacokinetics of intraocular penetration of hemisuccinate methyl prednisolone (HMP) after its delivery using the transscleral Coulomb controlled iontophoresis (CCI) system applied to the eye or after intravenous (i.v.) injection in the rabbit, (2) to test the safety of the CCI system for the treated eyes and (3) to compare the pharmacokinetic profiles of HMP intraocular distribution after CCI delivery to i.v. injection. For each parameter evaluated, six rabbit eyes were used. For the CCI system, two concentrations of HMP (62.5 and 150mg ml(-1)), various intensities of current and duration of treatment were analyzed. In rabbits serving as controls the HMP was infused in the CCI device but without applied electric current. For the i.v. delivery, HMP at 10mg kg(-1)as a 62.5mg ml(-1)solution was used. The rabbits were observed clinically for evidence of ocular toxicity. At various time points after the administration of drug, rabbits were killed and intraocular fluids and tissues were sampled for methylprednisolone (MP) concentrations by high pressure liquid chromatography (HPLC). Histology examinations were performed on six eyes of each group. Among groups that received CCI, the concentrations of MP increased in all ocular tissues and fluids in relation to the intensities of current used (0.4, 1.0 and 2.0mA/0.5cm(2)) and its duration (4 and 10min). Sustained and highest levels of MP were achieved in the choroid and the retina of rabbit eyes treated with the highest current and 10min duration of CCI. No clinical toxicity or histological lesions were observed following CCI. Negligible amounts of MP were found in ocular tissues in the CCI control group without application of current. Compared to i.v. administration, CCI achieved higher and more sustained tissue concentrations with negligible systemic absorption. These data demonstrate that high levels of MP can be safely achieved in intraocular tissues and fluids of the rabbit eye, using CCI. With this system, intraocular tissues levels of MP are higher than those achieved after i.v. injection. Furthermore, if needed, the drug levels achieved with CCI can be modulated as a function of current intensity and duration of treatment. CCI could therefore be used as an alternative method for the delivery of high levels of MP to the intraocular tissues of both the anterior and posterior segments.
Resumo:
Electrotransfer and iontophoresis are being developed as innovative non-viral gene delivery systems for the treatment of eye diseases. These two techniques rely on the use of electric current to allow for higher transfection yield of various ocular cell types in vivo. Short pulses of relatively high-intensity electric fields are used for electrotransfer delivery, whereas the iontophoresis technique is based on the application of low voltage electric current. The basic principles of these techniques and their potential therapeutic application for diseases of the anterior and posterior segments of the eye are reviewed. Iontophoresis has been found most efficient for the delivery of small nucleic acid fragments such as antisense oligonucleotides, siRNA, or ribozymes. Electrotransfer, on the other hand, is being developed for the delivery of oligonucleotides or custom designed plasmids. The wide range of strategies already validated and the potential for targeting specific types of cells confirm the promising early observations made using electrotransfer and iontophoresis. These two nonviral delivery systems are safe and can be used efficiently for targeted gene delivery to ocular tissues in vivo. At the present, their application for the treatment of ocular human diseases is nearing its final stages of adaptation and practical implementation at the bedside.
Resumo:
Life-history models predict an evolutionary trade-off in the allocation of resources to current versus future reproduction. This corresponds, at the physiological level, to a trade-off in the allocation of resources to current reproduction or to the immune system, which will enhance survival and therefore future reproduction. For clutch size, life-history models predict a positive correlation between current measurement in eggs and the subsequent parasite load. Tn a population of great tits, we analyzed the correlation between natural clutch size of females and the subsequent prevalence of Plasmodium spp., a potentially harmful blood parasite. Females that showed, 14 days after hatching of the nestlings, an infection with Plasmodium had a significantly larger clutch (9.3 eggs +/- 0.5 SE, n = 18) than uninfected females (8.0 eggs +/- 0.2 SE, n = 80), as predicted by the allocation trade-off. Clutch size was positively correlated with tile prevalence of Plasmodium, but brood size 14 days after hatching was not. This suggests that females incur higher costs during laying the clutch than during rearing nestlings. Infection status of some females changed between years, and these changes were significantly correlated with a change in clutch size as predicted by die trade-off. The link between reproductive effort and parasitism may represent a possible mechanism by which the cost of egg production is mediated into future survival and may thereby be an important selective force in the shaping of clutch size.
Resumo:
Gene correction at the site of the mutation in the chromosome is the absolute way to really cure a genetic disease. The oligonucleotide (ODN)-mediated gene repair technology uses an ODN perfectly complementary to the genomic sequence except for a mismatch at the base that is mutated. The endogenous repair machinery of the targeted cell then mediates substitution of the desired base in the gene, resulting in a completely normal sequence. Theoretically, it avoids potential gene silencing or random integration associated with common viral gene augmentation approaches and allows an intact regulation of expression of the therapeutic protein. The eye is a particularly attractive target for gene repair because of its unique features (small organ, easily accessible, low diffusion into systemic circulation). Moreover therapeutic effects on visual impairment could be obtained with modest levels of repair. This chapter describes in details the optimized method to target active ODNs to the nuclei of photoreceptors in neonatal mouse using (1) an electric current application at the eye surface (saline transpalpebral iontophoresis), (2) combined with an intravitreous injection of ODNs, as well as the experimental methods for (3) the dissection of adult neural retinas, (4) their immuno-labelling, and (5) flat-mounting for direct observation of photoreceptor survival, a relevant criteria of treatment outcomes for retinal degeneration.
Resumo:
Pioneer work on iontophoresis undertaken by David Maurice during the 1970s and 1980s laid the initial groundwork for its potential implementation as a promising ocular therapeutic modality. A better understanding of tissue interactions within the eye during electric current application, along with better designs of drug delivery devices have enabled us to pursue David Maurice's original ideas and take them from the bench to the bed side. In the present study we demonstrate the potential application of an iontophoresis device (Eyegate, Optis, France) for the treatment of certain human eye diseases. Seventeen patients received a penetrating keratoplasty (PKP) at various intervals before presentation with active graft rejection in our clinic and were treated using this iontophoresis device. Methylprednisolone sodium succinate (MP) 62.5 mg/ml was infused within the Eyegate ocular probe container and an electrical current of 1.5 mA was delivered for 4 min with the negative pole connected to the ocular probe. Patients were treated on an ambulatory basis and received a standard course of three iontophoresis applications given once a day over 3 consecutive days. After treatment, 15 of the 17 treated eyes (88%) demonstrated a complete reversal of the rejection processes. In two eyes, only a partial and temporary improvement was observed. The mean best corrected visual acuity of all 17 patients during the last follow up visit was 0.37 +/- 0.2 compared to 0.06 +/- 0.05 before initiation of the iontophoresis treatment. The mean follow-up time was 13.7 months with a range of 5-29 months for the 17 patients. No significant side-effects associated with the iontophoresis treatment were observed. Thus, for the management of active corneal graft rejection, iontophoresis of MP can be an alternative to very frequent instillations of eye drops, or to pulsed intravenous therapy of corticosteroids.
Resumo:
NlmCategory="UNASSIGNED">This study is aimed at the determination of the measurement properties of the shoulder function B-B Score measured with a smartphone. This score measures the symmetry between sides of a power-related metric for two selected movements, with 100% representing perfect symmetry. Twenty healthy participants, 20 patients with rotator cuff conditions, 23 with fractures, 22 with capsulitis, and 23 with shoulder instabilities were measured twice across a six-month interval using the B-B Score and shoulder function questionnaires. The discriminative power, responsiveness, diagnostic power, concurrent validity, minimal detectable change (MDC), minimal clinically important improvement (MCII), and patient acceptable symptom state (PASS) were evaluated. Significant differences with the control group and significant baseline-six-month differences were found for the rotator cuff condition, fracture, and capsulitis patient groups. The B-B Score was responsive and demonstrated excellent diagnostic power, except for shoulder instability. The correlations with clinical scores were generally moderate to high, but lower for instability. The MDC was 18.1%, the MCII was 25.2%, and the PASS was 77.6. No floor effect was observed. The B-B Score demonstrated excellent measurement properties in populations with rotator cuff conditions, proximal humerus fractures, and capsulitis, and can thus be used as a routine test to evaluate those patients.
Resumo:
Energy metabolism measurements in spinal cord tumors, as well as in osseous spinal tumors/metastasis in vivo, are rarely performed only with molecular imaging (MI) by positron emission tomography (PET). This imaging modality developed from a small number of basic clinical science investigations followed by subsequent work that influenced and enhanced the research of others. Apart from precise anatomical localization by coregistration of morphological imaging and quantification, the most intriguing advantage of this imaging is the opportunity to investigate the time course (dynamics) of disease-specific molecular events in the intact organism. Most importantly, MI represents one of the key technologies in translational molecular neuroscience research, helping to develop experimental protocols that may later be applied to human patients. PET may help monitor a patient at the vertebral level after surgery and during adjuvant treatment for recurrent or progressive disease. Common clinical indications for MI of primary or secondary CNS spinal tumors are: (i) tumor diagnosis, (ii) identification of the metabolically active tumor compartments (differentiation of viable tumor tissue from necrosis) and (iii) prediction of treatment response by measurement of tumor perfusion or ischemia. While spinal PET has been used under specific circumstances, a question remains as to whether the magnitude of biochemical alterations observed by MI in CNS tumors in general (specifically spinal tumors) can reveal any prognostic value with respect to survival. MI may be able to better identify early disease and to differentiate benign from malignant lesions than more traditional methods. Moreover, an adequate identification of treatment effectiveness may influence patient management. MI probes could be developed to image the function of targets without disturbing them or as treatment to modify the target's function. MI therefore closes the gap between in vitro and in vivo integrative biology of disease. At the spinal level, MI may help to detect progression or recurrence of metastatic disease after surgical treatment. In cases of nonsurgical treatments such as chemo-, hormone- or radiotherapy, it may better assess biological efficiency than conventional imaging modalities coupled with blood tumor markers. In fact, PET provides a unique possibility to correlate topography and specific metabolic activity, but it requires additional clinical and experimental experience and research to find new indications for primary or secondary spinal tumors.
Resumo:
BACKGROUND: Chronic pain is frequent in persons living with spinal cord injury (SCI). Conventionally, the pain is treated pharmacologically, yet long-term pain medication is often refractory and associated with side effects. Non-pharmacological interventions are frequently advocated, although the benefit and harm profiles of these treatments are not well established, in part because of methodological weaknesses of available studies. OBJECTIVES: To critically appraise and synthesise available research evidence on the effects of non-pharmacological interventions for the treatment of chronic neuropathic and nociceptive pain in people living with SCI. SEARCH METHODS: The search was run on the 1st March 2011. We searched the Cochrane Injuries Group's Specialised Register, the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE (OvidSP), Embase (OvidSP), PsycINFO (OvidSP), four other databases and clinical trials registers. In addition, we manually searched the proceedings of three major scientific conferences on SCI. We updated this search in November 2014 but these results have not yet been incorporated. SELECTION CRITERIA: Randomised controlled trials of any intervention not involving intake of medication or other active substances to treat chronic pain in people with SCI. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted data and assessed risk of bias in the included studies. The primary outcome was any measure of pain intensity or pain relief. Secondary outcomes included adverse events, anxiety, depression and quality of life. When possible, meta-analyses were performed to calculate standardised mean differences for each type of intervention. MAIN RESULTS: We identified 16 trials involving a total of 616 participants. Eight different types of interventions were studied. Eight trials investigated the effects of electrical brain stimulation (transcranial direct current stimulation (tDCS) and cranial electrotherapy stimulation (CES); five trials) or repetitive transcranial magnetic stimulation (rTMS; three trials). Interventions in the remaining studies included exercise programmes (three trials); acupuncture (two trials); self-hypnosis (one trial); transcutaneous electrical nerve stimulation (TENS) (one trial); and a cognitive behavioural programme (one trial). None of the included trials were considered to have low overall risk of bias. Twelve studies had high overall risk of bias, and in four studies risk of bias was unclear. The overall quality of the included studies was weak. Their validity was impaired by methodological weaknesses such as inappropriate choice of control groups. An additional search in November 2014 identified more recent studies that will be included in an update of this review.For tDCS the pooled mean difference between intervention and control groups in pain scores on an 11-point visual analogue scale (VAS) (0-10) was a reduction of -1.90 units (95% confidence interval (CI) -3.48 to -0.33; P value 0.02) in the short term and of -1.87 (95% CI -3.30 to -0.45; P value 0.01) in the mid term. Exercise programmes led to mean reductions in chronic shoulder pain of -1.9 score points for the Short Form (SF)-36 item for pain experience (95% CI -3.4 to -0.4; P value 0.01) and -2.8 pain VAS units (95% CI -3.77 to -1.83; P value < 0.00001); this represented the largest observed treatment effects in the included studies. Trials using rTMS, CES, acupuncture, self-hypnosis, TENS or a cognitive behavioural programme provided no evidence that these interventions reduce chronic pain. Ten trials examined study endpoints other than pain, including anxiety, depression and quality of life, but available data were too scarce for firm conclusions to be drawn. In four trials no side effects were reported with study interventions. Five trials reported transient mild side effects. Overall, a paucity of evidence was found on any serious or long-lasting side effects of the interventions. AUTHORS' CONCLUSIONS: Evidence is insufficient to suggest that non-pharmacological treatments are effective in reducing chronic pain in people living with SCI. The benefits and harms of commonly used non-pharmacological pain treatments should be investigated in randomised controlled trials with adequate sample size and study methodology.
Resumo:
Even though anal incontinence affects a significant proportion of the population, causing a major burden to both patient and society, it still remains "the last closet issue". Less than a third of patients will share this problem with their physician. Consequently, the incidence of anal incontinence is difficult to determine, varying from 2-50%. Since this disabling condition is often associated with urinary incontinence and/or pelvic organ prolapse, a multidisciplinary team approach is required. A wide range of therapeutic options are available. When dietary, medical and rehabilitative treatments have failed, sacral neuromodulation should be considered in selected cases. More invasive surgery is usually undertaken in the presence of major structural defects. The aim of this article is to suggest a comprehensive way of identifying and treating anal incontinence.
Resumo:
Abstract : The occupational health risk involved with handling nanoparticles is the probability that a worker will experience an adverse health effect: this is calculated as a function of the worker's exposure relative to the potential biological hazard of the material. Addressing the risks of nanoparticles requires therefore knowledge on occupational exposure and the release of nanoparticles into the environment as well as toxicological data. However, information on exposure is currently not systematically collected; therefore this risk assessment lacks quantitative data. This thesis aimed at, first creating the fundamental data necessary for a quantitative assessment and, second, evaluating methods to measure the occupational nanoparticle exposure. The first goal was to determine what is being used where in Swiss industries. This was followed by an evaluation of the adequacy of existing measurement methods to assess workplace nanopaiticle exposure to complex size distributions and concentration gradients. The study was conceived as a series of methodological evaluations aimed at better understanding nanoparticle measurement devices and methods. lt focused on inhalation exposure to airborne particles, as respiration is considered to be the most important entrance pathway for nanoparticles in the body in terms of risk. The targeted survey (pilot study) was conducted as a feasibility study for a later nationwide survey on the handling of nanoparticles and the applications of specific protection means in industry. The study consisted of targeted phone interviews with health and safety officers of Swiss companies that were believed to use or produce nanoparticles. This was followed by a representative survey on the level of nanoparticle usage in Switzerland. lt was designed based on the results of the pilot study. The study was conducted among a representative selection of clients of the Swiss National Accident Insurance Fund (SUVA), covering about 85% of Swiss production companies. The third part of this thesis focused on the methods to measure nanoparticles. Several pre- studies were conducted studying the limits of commonly used measurement devices in the presence of nanoparticle agglomerates, This focus was chosen, because several discussions with users and producers of the measurement devices raised questions about their accuracy measuring nanoparticle agglomerates and because, at the same time, the two survey studies revealed that such powders are frequently used in industry. The first preparatory experiment focused on the accuracy of the scanning mobility particle sizer (SMPS), which showed an improbable size distribution when measuring powders of nanoparticle agglomerates. Furthermore, the thesis includes a series of smaller experiments that took a closer look at problems encountered with other measurement devices in the presence of nanoparticle agglomerates: condensation particle counters (CPC), portable aerosol spectrometer (PAS) a device to estimate the aerodynamic diameter, as well as diffusion size classifiers. Some initial feasibility tests for the efficiency of filter based sampling and subsequent counting of carbon nanotubes (CNT) were conducted last. The pilot study provided a detailed picture of the types and amounts of nanoparticles used and the knowledge of the health and safety experts in the companies. Considerable maximal quantities (> l'000 kg/year per company) of Ag, Al-Ox, Fe-Ox, SiO2, TiO2, and ZnO (mainly first generation particles) were declared by the contacted Swiss companies, The median quantity of handled nanoparticles, however, was 100 kg/year. The representative survey was conducted by contacting by post mail a representative selection of l '626 SUVA-clients (Swiss Accident Insurance Fund). It allowed estimation of the number of companies and workers dealing with nanoparticles in Switzerland. The extrapolation from the surveyed companies to all companies of the Swiss production sector suggested that l'309 workers (95%-confidence interval l'073 to l'545) of the Swiss production sector are potentially exposed to nanoparticles in 586 companies (145 to l'027). These numbers correspond to 0.08% (0.06% to 0.09%) of all workers and to 0.6% (0.2% to 1.1%) of companies in the Swiss production sector. To measure airborne concentrations of sub micrometre-sized particles, a few well known methods exist. However, it was unclear how well the different instruments perform in the presence of the often quite large agglomerates of nanostructured materials. The evaluation of devices and methods focused on nanoparticle agglomerate powders. lt allowed the identification of the following potential sources of inaccurate measurements at workplaces with considerable high concentrations of airborne agglomerates: - A standard SMPS showed bi-modal particle size distributions when measuring large nanoparticle agglomerates. - Differences in the range of a factor of a thousand were shown between diffusion size classifiers and CPC/SMPS. - The comparison between CPC/SMPS and portable aerosol Spectrometer (PAS) was much better, but depending on the concentration, size or type of the powders measured, the differences were still of a high order of magnitude - Specific difficulties and uncertainties in the assessment of workplaces were identified: the background particles can interact with particles created by a process, which make the handling of background concentration difficult. - Electric motors produce high numbers of nanoparticles and confound the measurement of the process-related exposure. Conclusion: The surveys showed that nanoparticles applications exist in many industrial sectors in Switzerland and that some companies already use high quantities of them. The representative survey demonstrated a low prevalence of nanoparticle usage in most branches of the Swiss industry and led to the conclusion that the introduction of applications using nanoparticles (especially outside industrial chemistry) is only beginning. Even though the number of potentially exposed workers was reportedly rather small, it nevertheless underscores the need for exposure assessments. Understanding exposure and how to measure it correctly is very important because the potential health effects of nanornaterials are not yet fully understood. The evaluation showed that many devices and methods of measuring nanoparticles need to be validated for nanoparticles agglomerates before large exposure assessment studies can begin. Zusammenfassung : Das Gesundheitsrisiko von Nanopartikel am Arbeitsplatz ist die Wahrscheinlichkeit dass ein Arbeitnehmer einen möglichen Gesundheitsschaden erleidet wenn er diesem Stoff ausgesetzt ist: sie wird gewöhnlich als Produkt von Schaden mal Exposition gerechnet. Für eine gründliche Abklärung möglicher Risiken von Nanomaterialien müssen also auf der einen Seite Informationen über die Freisetzung von solchen Materialien in die Umwelt vorhanden sein und auf der anderen Seite solche über die Exposition von Arbeitnehmenden. Viele dieser Informationen werden heute noch nicht systematisch gesarnmelt und felilen daher für Risikoanalysen, Die Doktorarbeit hatte als Ziel, die Grundlagen zu schaffen für eine quantitative Schatzung der Exposition gegenüber Nanopartikel am Arbeitsplatz und die Methoden zu evaluieren die zur Messung einer solchen Exposition nötig sind. Die Studie sollte untersuchen, in welchem Ausmass Nanopartikel bereits in der Schweizer Industrie eingesetzt werden, wie viele Arbeitnehrner damit potentiel] in Kontakt komrrien ob die Messtechnologie für die nötigen Arbeitsplatzbelastungsmessungen bereits genügt, Die Studie folcussierte dabei auf Exposition gegenüber luftgetragenen Partikel, weil die Atmung als Haupteintrittspforte iïlr Partikel in den Körper angesehen wird. Die Doktorarbeit besteht baut auf drei Phasen auf eine qualitative Umfrage (Pilotstudie), eine repräsentative, schweizerische Umfrage und mehrere technische Stndien welche dem spezitischen Verständnis der Mëglichkeiten und Grenzen einzelner Messgeräte und - teclmikeri dienen. Die qualitative Telephonumfrage wurde durchgeführt als Vorstudie zu einer nationalen und repräsentativen Umfrage in der Schweizer Industrie. Sie zielte auf Informationen ab zum Vorkommen von Nanopartikeln, und den angewendeten Schutzmassnahmen. Die Studie bestand aus gezielten Telefoninterviews mit Arbeit- und Gesundheitsfachpersonen von Schweizer Unternehmen. Die Untemehmen wurden aufgrund von offentlich zugànglichen lnformationen ausgewählt die darauf hinwiesen, dass sie mit Nanopartikeln umgehen. Der zweite Teil der Dolctorarbeit war die repräsentative Studie zur Evalniernng der Verbreitnng von Nanopaitikelanwendungen in der Schweizer lndustrie. Die Studie baute auf lnformationen der Pilotstudie auf und wurde mit einer repräsentativen Selektion von Firmen der Schweizerischen Unfall Versicherungsanstalt (SUVA) durchgeüihxt. Die Mehrheit der Schweizerischen Unternehmen im lndustrieselctor wurde damit abgedeckt. Der dritte Teil der Doktorarbeit fokussierte auf die Methodik zur Messung von Nanopartikeln. Mehrere Vorstudien wurden dnrchgefîihrt, um die Grenzen von oft eingesetzten Nanopartikelmessgeräten auszuloten, wenn sie grösseren Mengen von Nanopartikel Agglomeraten ausgesetzt messen sollen. Dieser F okns wurde ans zwei Gründen gewählt: weil mehrere Dislcussionen rnit Anwendem und auch dem Produzent der Messgeràte dort eine Schwachstelle vermuten liessen, welche Zweifel an der Genauigkeit der Messgeräte aufkommen liessen und weil in den zwei Umfragestudien ein häufiges Vorkommen von solchen Nanopartikel-Agglomeraten aufgezeigt wurde. i Als erstes widmete sich eine Vorstndie der Genauigkeit des Scanning Mobility Particle Sizer (SMPS). Dieses Messgerät zeigte in Präsenz von Nanopartikel Agglorneraten unsinnige bimodale Partikelgrössenverteilung an. Eine Serie von kurzen Experimenten folgte, welche sich auf andere Messgeräte und deren Probleme beim Messen von Nanopartikel-Agglomeraten konzentrierten. Der Condensation Particle Counter (CPC), der portable aerosol spectrometer (PAS), ein Gerät zur Schàtzung des aerodynamischen Durchniessers von Teilchen, sowie der Diffusion Size Classifier wurden getestet. Einige erste Machbarkeitstests zur Ermittlnng der Effizienz von tilterbasierter Messung von luftgetragenen Carbon Nanotubes (CNT) wnrden als letztes durchgeiührt. Die Pilotstudie hat ein detailliiertes Bild der Typen und Mengen von genutzten Nanopartikel in Schweizer Unternehmen geliefert, und hat den Stand des Wissens der interviewten Gesundheitsschntz und Sicherheitsfachleute aufgezeigt. Folgende Typen von Nanopaitikeln wurden von den kontaktierten Firmen als Maximalmengen angegeben (> 1'000 kg pro Jahr / Unternehrnen): Ag, Al-Ox, Fe-Ox, SiO2, TiO2, und ZnO (hauptsächlich Nanopartikel der ersten Generation). Die Quantitäten von eingesetzten Nanopartikeln waren stark verschieden mit einem ein Median von 100 kg pro Jahr. ln der quantitativen Fragebogenstudie wurden l'626 Unternehmen brieflich kontaktiert; allesamt Klienten der Schweizerischen Unfallversicherringsanstalt (SUVA). Die Resultate der Umfrage erlaubten eine Abschätzung der Anzahl von Unternehmen und Arbeiter, welche Nanopartikel in der Schweiz anwenden. Die Hochrechnung auf den Schweizer lndnstriesektor hat folgendes Bild ergeben: ln 586 Unternehmen (95% Vertrauensintervallz 145 bis 1'027 Unternehmen) sind 1'309 Arbeiter potentiell gegenüber Nanopartikel exponiert (95%-Vl: l'073 bis l'545). Diese Zahlen stehen für 0.6% der Schweizer Unternehmen (95%-Vl: 0.2% bis 1.1%) und 0.08% der Arbeiternehmerschaft (95%-V1: 0.06% bis 0.09%). Es gibt einige gut etablierte Technologien um die Luftkonzentration von Submikrometerpartikel zu messen. Es besteht jedoch Zweifel daran, inwiefern sich diese Technologien auch für die Messurrg von künstlich hergestellten Nanopartikeln verwenden lassen. Aus diesem Grund folcussierten die vorbereitenden Studien für die Arbeitsplatzbeurteilnngen auf die Messung von Pulverri, welche Nan0partike1-Agg10merate enthalten. Sie erlaubten die ldentifikation folgender rnöglicher Quellen von fehlerhaften Messungen an Arbeitsplätzen mit erhöhter Luft-K0nzentrati0n von Nanopartikel Agglomeratenz - Ein Standard SMPS zeigte eine unglaubwürdige bimodale Partikelgrössenverteilung wenn er grössere Nan0par'til<e1Agg10merate gemessen hat. - Grosse Unterschiede im Bereich von Faktor tausend wurden festgestellt zwischen einem Diffusion Size Classiîier und einigen CPC (beziehungsweise dem SMPS). - Die Unterschiede zwischen CPC/SMPS und dem PAS waren geringer, aber abhängig von Grosse oder Typ des gemessenen Pulvers waren sie dennoch in der Grössenordnung von einer guten Grössenordnung. - Spezifische Schwierigkeiten und Unsicherheiten im Bereich von Arbeitsplatzmessungen wurden identitiziert: Hintergrundpartikel können mit Partikeln interagieren die während einem Arbeitsprozess freigesetzt werden. Solche Interaktionen erschweren eine korrekte Einbettung der Hintergrunds-Partikel-Konzentration in die Messdaten. - Elektromotoren produzieren grosse Mengen von Nanopartikeln und können so die Messung der prozessbezogenen Exposition stören. Fazit: Die Umfragen zeigten, dass Nanopartikel bereits Realitàt sind in der Schweizer Industrie und dass einige Unternehmen bereits grosse Mengen davon einsetzen. Die repräsentative Umfrage hat diese explosive Nachricht jedoch etwas moderiert, indem sie aufgezeigt hat, dass die Zahl der Unternehmen in der gesamtschweizerischen Industrie relativ gering ist. In den meisten Branchen (vor allem ausserhalb der Chemischen Industrie) wurden wenig oder keine Anwendungen gefunden, was schliessen last, dass die Einführung dieser neuen Technologie erst am Anfang einer Entwicklung steht. Auch wenn die Zahl der potentiell exponierten Arbeiter immer noch relativ gering ist, so unterstreicht die Studie dennoch die Notwendigkeit von Expositionsmessungen an diesen Arbeitsplätzen. Kenntnisse um die Exposition und das Wissen, wie solche Exposition korrekt zu messen, sind sehr wichtig, vor allem weil die möglichen Auswirkungen auf die Gesundheit noch nicht völlig verstanden sind. Die Evaluation einiger Geräte und Methoden zeigte jedoch, dass hier noch Nachholbedarf herrscht. Bevor grössere Mess-Studien durgefîihrt werden können, müssen die Geräte und Methodem für den Einsatz mit Nanopartikel-Agglomeraten validiert werden.
Resumo:
High performance liquid chromatography (HPLC) is the reference method for measuring concentrations of antimicrobials in blood. This technique requires careful sample preparation. Protocols using organic solvents and/or solid extraction phases are time consuming and entail several manipulations, which can lead to partial loss of the determined compound and increased analytical variability. Moreover, to obtain sufficient material for analysis, at least 1 ml of plasma is required. This constraint makes it difficult to determine drug levels when blood sample volumes are limited. However, drugs with low plasma-protein binding can be reliably extracted from plasma by ultra-filtration with a minimal loss due to the protein-bound fraction. This study validated a single-step ultra-filtration method for extracting fluconazole (FLC), a first-line antifungal agent with a weak plasma-protein binding, from plasma to determine its concentration by HPLC. Spiked FLC standards and unknowns were prepared in human and rat plasma. Samples (240 microl) were transferred into disposable microtube filtration units containing cellulose or polysulfone filters with a 5 kDa cut-off. After centrifugation for 60 min at 15000g, FLC concentrations were measured by direct injection of the filtrate into the HPLC. Using cellulose filters, low molecular weight proteins were eluted early in the chromatogram and well separated from FLC that eluted at 8.40 min as a sharp single peak. In contrast, with polysulfone filters several additional peaks interfering with the FLC peak were observed. Moreover, the FLC recovery using cellulose filters compared to polysulfone filters was higher and had a better reproducibility. Cellulose filters were therefore used for the subsequent validation procedure. The quantification limit was 0.195 mgl(-1). Standard curves with a quadratic regression coefficient > or = 0.9999 were obtained in the concentration range of 0.195-100 mgl(-1). The inter and intra-run accuracies and precisions over the clinically relevant concentration range, 1.875-60 mgl(-1), fell well within the +/-15% variation recommended by the current guidelines for the validation of analytical methods. Furthermore, no analytical interference was observed with commonly used antibiotics, antifungals, antivirals and immunosuppressive agents. Ultra-filtration of plasma with cellulose filters permits the extraction of FLC from small volumes (240 microl). The determination of FLC concentrations by HPLC after this single-step procedure is selective, precise and accurate.
Resumo:
Tumour immunologists strive to develop efficient tumour vaccination and adoptive transfer therapies that enlarge the pool of tumour-specific and -reactive effector T-cells in vivo. To assess the efficiency of the various strategies, ex vivo assays are needed for the longitudinal monitoring of the patient's specific immune responses providing both quantitative and qualitative data. In particular, since tumour cell cytolysis is the end goal of tumour immunotherapy, routine immune monitoring protocols need to include a read-out for the cytolytic efficiency of Ag-specific cells. We propose to combine current immune monitoring techniques in a highly sensitive and reproducible multi-parametric flow cytometry based cytotoxicity assay that has been optimised to require low numbers of Ag-specific T-cells. The possibility of re-analysing those T-cells that have undergone lytic activity is illustrated by the concomitant detection of CD107a upregulation on the surface of degranulated T-cells. To date, the LiveCount Assay provides the only possibility of assessing the ex vivo cytolytic activity of low-frequency Ag-specific cytotoxic T-lymphocytes from patient material.
The Europeanisation of the measurement of diversity in education: a soft instrument of public policy
Resumo:
Faced with an increasing number of data and rankings, the author questions the roles of the different groups of actors who were originally involved in questioning the use of statistical indicators as a means of addressing issues of access to higher education. The comparison and nature of these international (UNESCO, OECD, EUROSTAT) and national (Germany, England, France, Switzerland) indicators in matters of inequalities of access to higher education question the tension between the discourses and the indicators they generate, and their recording at the national level. Who says what and with what consequences? What range of actors are involved in this process? What kind of power relations forms them? The author discusses how the issue of inequalities of access to higher education got on to the agendas of European organisations, identifies the policies that were defined, and sets them against an array of indicators, showing the discrepancy between the discourses and what the indicators reveal, the gap between the recommendations and the available tools. Why is there such a contrast? What are the mechanisms at work? Is it a technical or a political problem? What does this discrepancy reveal as far as national specificities within the construction of social inequalities are concerned?