22 resultados para EMISSION ANALYSIS
em Université de Lausanne, Switzerland
Resumo:
It has been demonstrated in earlier studies that patients with a cochlear implant have increased abilities for audio-visual integration because the crude information transmitted by the cochlear implant requires the persistent use of the complementary speech information from the visual channel. The brain network for these abilities needs to be clarified. We used an independent components analysis (ICA) of the activation (H2 (15) O) positron emission tomography data to explore occipito-temporal brain activity in post-lingually deaf patients with unilaterally implanted cochlear implants at several months post-implantation (T1), shortly after implantation (T0) and in normal hearing controls. In between-group analysis, patients at T1 had greater blood flow in the left middle temporal cortex as compared with T0 and normal hearing controls. In within-group analysis, patients at T0 had a task-related ICA component in the visual cortex, and patients at T1 had one task-related ICA component in the left middle temporal cortex and the other in the visual cortex. The time courses of temporal and visual activities during the positron emission tomography examination at T1 were highly correlated, meaning that synchronized integrative activity occurred. The greater involvement of the visual cortex and its close coupling with the temporal cortex at T1 confirm the importance of audio-visual integration in more experienced cochlear implant subjects at the cortical level.
Resumo:
PURPOSE: The aim of this study was to conduct a systematic review and perform a meta-analysis on the diagnostic performances of (18)F-fluorodeoxyglucose positron emission tomography (FDG PET) for giant cell arteritis (GCA), with or without polymyalgia rheumatica (PMR). METHODS: MEDLINE, Embase and the Cochrane Library were searched for articles in English that evaluated FDG PET in GCA or PMR. All complete studies were reviewed and qualitatively analysed. Studies that fulfilled the three following criteria were included in a meta-analysis: (1) FDG PET used as a diagnostic tool for GCA and PMR; (2) American College of Rheumatology and Healey criteria used as the reference standard for the diagnosis of GCA and PMR, respectively; and (3) the use of a control group. RESULTS: We found 14 complete articles. A smooth linear or long segmental pattern of FDG uptake in the aorta and its main branches seems to be a characteristic pattern of GCA. Vessel uptake that was superior to liver uptake was considered an efficient marker for vasculitis. The meta-analysis of six selected studies (101 vasculitis and 182 controls) provided the following results: sensitivity 0.80 [95% confidence interval (CI) 0.63-0.91], specificity 0.89 (95% CI 0.78-0.94), positive predictive value 0.85 (95% CI 0.62-0.95), negative predictive value 0.88 (95% CI 0.72-0.95), positive likelihood ratio 6.73 (95% CI 3.55-12.77), negative likelihood ratio 0.25 (95% CI 0.13-0.46) and accuracy 0.84 (95% CI 0.76-0.90). CONCLUSION: We found overall valuable diagnostic performances for FDG PET against reference criteria. Standardized FDG uptake criteria are needed to optimize these diagnostic performances.
Resumo:
Toperform a meta-analysis of FDG-PET performances in the diagnosis of largevessels vasculitis (Giant Cell Arteritis (GCA) associated or not withPolymyalgia Rheumatica(PMR), Takayasu). Materials and methods : The MEDLINE,Cochrane Library, Embase were searched for relevant original articlesdescribing FDG-PET for vasculitis assessment, using MesH terms ("GiantCell Arteritis or Vasculitis" AND "PET"). Criteria for inclusionwere:(1)FDG-PET for diagnosis of vasculitis(2)American College of Rheumatologycriteria as reference standard(3)control group. After data extraction, analyseswere performed using a random-effects model. Results : Of 184 citations(database search and references screening),70 articles were reviewed of which12 eligible studies were extracted (sensitivity range from 32% to 97%). 7studies fulfilled all inclusion criteria. Owing to overlapping population, 1study was excluded. Statistical heterogeneity justified the random-effectsmodel. Pooled 6 studies analysis(116 vasculitis,224 controls) showed a 81%sensitivity (95%CI:70-89%);a 89% specificity (95%CI:77-95%);a 85%PPV(95%CI:63-95%); a 90% NPV(95%CI:79-95%);a 7.1 positive LR(95%CI:3.4-14.9); a0.2 negative LR(95%CI:0.14-0.35) and 90.1 DOR(95%CI: 18.6-437). Conclusion :FDG-PET has good diagnostic performances in the detection of large vesselsvasculitis. Its promising role could be extended to follow up patients undertreatment, but further studies are needed to confirm this possibility.
Resumo:
OBJECTIVE: To systematically review and meta-analyze published data about the diagnostic performance of Fluorine-18-Fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (PET/CT) in the assessment of pleural abnormalities in cancer patients. METHODS: A comprehensive literature search of studies published through June 2013 regarding the role of (18)F-FDG-PET and PET/CT in evaluating pleural abnormalities in cancer patients was performed. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odd ratio (DOR) of (18)F-FDG-PET or PET/CT on a per patient-based analysis were calculated. The area under the summary ROC curve (AUC) was calculated to measure the accuracy of these methods in the assessment of pleural abnormalities. Sub-analyses considering (18)F-FDG-PET/CT and patients with lung cancer only were carried out. RESULTS: Eight studies comprising 360 cancer patients (323 with lung cancer) were included. The meta-analysis of these selected studies provided the following results: sensitivity 86% [95% confidence interval (95%CI): 80-91%], specificity 80% [95%CI: 73-85%], LR+ 3.7 [95%CI: 2.8-4.9], LR- 0.18 [95%CI: 0.09-0.34], DOR 27 [95%CI: 13-56]. The AUC was 0.907. No significant improvement considering PET/CT studies only and patients with lung cancer was found. CONCLUSIONS: (18)F-FDG-PET and PET/CT demonstrated to be useful diagnostic imaging methods in the assessment of pleural abnormalities in cancer patients, nevertheless possible sources of false-negative and false-positive results should be kept in mind. The literature focusing on the use of (18)F-FDG-PET and PET/CT in this setting remains still limited and prospective studies are needed.
Resumo:
Gas chromatography (GC) is an analytical tool very useful to investigate the composition of gaseous mixtures. The different gases are separated by specific columns but, if hydrogen (H2 ) is present in the sample, its detection can be performed by a thermal conductivity detector or a helium ionization detector. Indeed, coupled to GC, no other detector can perform this detection except the expensive atomic emission detector. Based on the detection and analysis of H2 isotopes by low-pressure chemical ionization mass spectrometry (MS), a new method for H2 detection by GC coupled to MS with an electron ionization ion source and a quadrupole analyser is presented. The presence of H2 in a gaseous mixture could easily be put in evidence by the monitoring of the molecular ion of the protonated carrier gas. Copyright © 2013 John Wiley & Sons, Ltd.
Resumo:
BACKGROUND: Dissection during laparoscopic surgery produces smoke containing potentially toxic substances. The aim of the present study was to analyze smoke samples produced during laparoscopic colon surgery using a bipolar vessel sealing device (LigaSuretrade mark). METHODS: Four consecutive patients undergoing left-sided colectomy were enrolled in this pilot study. Smoke was produced by the use of LigaSuretrade mark. Samples (5,5l) were evacuated from the pneumoperitoneum in a closed system into a reservoir. Analysis was performed with CO2-laser-based photoacoustic spectroscopy and confirmed by a Fourier-transform infrared spectrum. The detected spectra were compared to the available spectra of known toxins. RESULTS: Samples from four laparoscopic sigmoid resections were analyzed. No relevant differences were noted regarding patient and operation characteristics. The gas samples were stable over time proven by congruent control measurements as late as 24 h after sampling. The absorption spectra differed considerably between the patients. One broad absorption line at 100 ppm indicating H2O and several unknown molecules were detected. With a sensitivity of alpha min ca 10-5 cm-1 no known toxic substances like phenol or indole were identified. CONCLUSION: The use of a vessel sealing device during laparoscopic surgery does not produce known toxic substances in relevant quantity. Further studies are needed to identify unknown molecules and to analyze gas emission under various conditions.
Resumo:
The application of support vector machine classification (SVM) to combined information from magnetic resonance imaging (MRI) and [F18]fluorodeoxyglucose positron emission tomography (FDG-PET) has been shown to improve detection and differentiation of Alzheimer's disease dementia (AD) and frontotemporal lobar degeneration. To validate this approach for the most frequent dementia syndrome AD, and to test its applicability to multicenter data, we randomly extracted FDG-PET and MRI data of 28 AD patients and 28 healthy control subjects from the database provided by the Alzheimer's Disease Neuroimaging Initiative (ADNI) and compared them to data of 21 patients with AD and 13 control subjects from our own Leipzig cohort. SVM classification using combined volume-of-interest information from FDG-PET and MRI based on comprehensive quantitative meta-analyses investigating dementia syndromes revealed a higher discrimination accuracy in comparison to single modality classification. For the ADNI dataset accuracy rates of up to 88% and for the Leipzig cohort of up to 100% were obtained. Classifiers trained on the ADNI data discriminated the Leipzig cohorts with an accuracy of 91%. In conclusion, our results suggest SVM classification based on quantitative meta-analyses of multicenter data as a valid method for individual AD diagnosis. Furthermore, combining imaging information from MRI and FDG-PET might substantially improve the accuracy of AD diagnosis.
Resumo:
BACKGROUND: Positron emission tomography (PET) during the cold pressor test (CPT) has been used to assess endothelium-dependent coronary vasoreactivity, a surrogate marker of cardiovascular events. However, its use remains limited by cardiac PET availability. As multidetector computed tomography (MDCT) is more widely available, we aimed to develop a measurement of endothelium-dependent coronary vasoreactivity with MDCT and similar radiation burden as with PET. METHODS AND RESULTS: A study group of 18 participants without known cardiovascular risk factor (9F/9M; age 60±6 years) underwent cardiac PET with (82)Rb and unenhanced ECG-gated MDCT within 4h, each time at rest and during CPT. The relation between absolute myocardial blood flow (MBF) response to CPT by PET (ml·min(-1)·g(1)) and relative changes in MDCT-measured coronary artery surface were assessed using linear regression analysis and Spearman's correlation. MDCT and PET/CT were analyzed in all participants. Hemodynamic conditions during CPT at MDCT and PET were similar (P>0.3). Relative changes in coronary artery surface because of CPT (2.0-21.2%) correlated to changes in MBF (-0.10-0.52ml·min(-1)·g(1)) (ρ=0.68, P=0.02). Effective dose was 1.3±0.2mSv for MDCT and 3.1mSv for PET/CT. CONCLUSIONS: Assessment of endothelium-dependent coronary vasoreactivity using MDCT CPT appears feasible. Because of its wider availability, shorter examination time and similar radiation burden, MDCT could be attractive in clinical research for coronary status assessment.
Resumo:
Photons participate in many atomic and molecular interactions and processes. Recent biophysical research has discovered an ultraweak radiation in biological tissues. It is now recognized that plants, animal and human cells emit this very weak biophotonic emission which can be readily measured with a sensitive photomultiplier system. UVA laser induced biophotonic emission of cultured cells was used in this report with the intention to detect biophysical changes between young and adult fibroblasts as well as between fibroblasts and keratinocytes. With suspension densities ranging from 1-8 x 106 cells/ml, it was evident that an increase of the UVA-laser-light induced photon emission intensity could be observed in young as well as adult fibroblastic cells. By the use of this method to determine ultraweak light emission, photons in cell suspensions in low volumes (100 microl) could be detected, in contrast to previous procedures using quantities up to 10 ml. Moreover, the analysis has been further refined by turning off the photomultiplier system electronically during irradiation leading to the first measurements of induced light emission in the cells after less than 10 micros instead of more than 100 milliseconds. These significant changes lead to an improvement factor up to 106 in comparison to classical detection procedures. In addition, different skin cells as fibroblasts and keratinocytes stemming from the same donor were measured using this new highly sensitive method in order to find new biophysical insight of light pathways. This is important in view to develop new strategies in biophotonics especially for use in alternative therapies.
Resumo:
Purpose: To compare MDCT, MRI and 18F-FDG PET/CT for the detection of peritoneal carcinomatosis due to ovarian cancerMethods and Materials: Fifteen women (mean age 65±) with clinical suspicion of ovarian cancer and peritoneal carcinomatosis underwent MDCT, MRI and 18F-FDG PET/CT, simultaneously and shortly performed before surgery (delay 8.1± days). According to the peritoneal cancer index nine abdominopelvic regions were defined. We applied four scores of lesion size on MDCT and MR images, while the maximal standard uptake value (SUVmax) was measured on 18F-FDG PET/CT. Three sites of lymphadenopathy and posterobasal pleural carcinomatosis were also analyzed. First, one radiologist blindly and separately read MDCT and MR images, while one nuclear physician blindly read PET/CT images grading each lesion according to four diagnostic certitudes. Secondly, all the images were reviewed jointly and compared with histopathology. Receiver operating characteristics (ROC) analysis was performed.Results: Peritoneal implants were proven in ten women (75%). Altogether, 228 abdominopelvic sites were compared. Sensitivity and specificity for MDCT was 90.2% and 90.6%, for MRI 93.5% and 86.3%, and for 18F-FDG PET/CT 92.7% and 95.7%, respectively. ROC area under the curve were 0.93 for MDCT and MRI, and 0.96 for 18F-FDG PET/CT respectively. No significant differences (p=0.11) were found between the three modalities.Conclusion: Although MRI revealed to be the most sensitive and 18F-FDG PET/CT the most specific modality, no significant differences were shown between the three techniques.
Resumo:
BACKGROUND: C iclosporine ( CsA), Tacrolimus (Tcl) and Infliximab (IFX) are effective rescue therapies in steroidrefractory ulcerative colitis (UC). Comparative studies are however m issing. M ETHOD: T his i s the retrospective analysis of treatment outcome for oral Tcl (n=27, initially 0.05mg/Kg twice daily, aiming for serum trough levels of 5-10 n g/mL), i ntravenous C sA ( n=23, 2 mg/kg/daily a nd then o ral CsA 5mg/kg/daily) and IFX ( n=43, 5 mg/kg intravenously at week 0, 2, 6 and then every 8 weeks) in patients with s teroid r efractory moderate to s evere UC enrolled i n the SWISS IBD cohort s tudy. After successful rescue therapy with Tcl o r C sA, t hiopurine m aintenance therapy or maintenance therapy with Tcl (in Tcl pretreated patients) was introduced. The endpoints analyzed steroid free r emission r ate (on the basis of m odified Truelove- Witts severity index (MTWSI)) and number of colectomies after 6 m onths. R ESULTS: A t 6 months, 26% ( 7/27) o f patients treated with T cl r emained i n steroid free remission (MTWSI score ≤4) compared to 30 % (7/23) on 18 droplets to the same extend under the linoleic acid treat, whereas lipid hydrolysis or loss was significantly increased in Huh-7 WT cells after 24h. Conclusions: Chronic alcohol feeding in obese, insulin-resistant rats exerts significant and synergistic effects on PNPLA3 mRNA expression, which correlated with triglyceride content. In v itro experiments suggest that PNPLA3 expression depends on the t ypes of d ietary f atty acids with polyunsaturated fatty a cids i nducing a nd monounsaturated fatty a cids inhibiting PNPLA3 mRNA. I148M polymorphism of PNPLA3 l eads to attenuation o f lipolytic processes resulting in fat accumulation in the cell. 20 CsA and 58% ( 27/41) o f patients t reated w ith IFX ( Tcl & CsA vs I FX p = 0 .018). S ignificant m ore patients had primary non response, loss of response or severe adverse events i n the CsA cohort ( 61%, 1 4/23) c ompared to Tcl cohort (33.3 % , 9/27), and IFX cohort (30%, 1 3/43) (p= 0.037). Colectomy rate was significantly higher after CsA (17.4 %, 4/23) compared to Tcl (3.7 %, 1/27) or IFX (2.3 %, 1/43) (p= 0.047).CONCLUSION: After s ix m onth, rescue therapy with I FX h ad t he l owest c olectomy r ate, significantly h igher steroid free r emission rate, a nd t he lowest rate of non-response, loss of response and severe adverse events compared to CsA or Tcl rescue treatment.
Resumo:
RATIONALE AND OBJECTIVES: To systematically review and meta-analyze published data about the diagnostic accuracy of fluorine-18-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (CT) in the differential diagnosis between malignant and benign pleural lesions. METHODS AND MATERIALS: A comprehensive literature search of studies published through June 2013 regarding the diagnostic performance of (18)F-FDG-PET and PET/CT in the differential diagnosis of pleural lesions was carried out. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odds ratio (DOR) of (18)F-FDG-PET or PET/CT in the differential diagnosis of pleural lesions on a per-patient-based analysis were calculated. The area under the summary receiver operating characteristic curve (AUC) was calculated to measure the accuracy of these methods. Subanalyses considering device used (PET or PET/CT) were performed. RESULTS: Sixteen studies including 745 patients were included in the systematic review. The meta-analysis of 11 selected studies provided the following results: sensitivity 95% (95% confidence interval [95%CI]: 92-97%), specificity 82% (95%CI: 76-88%), LR+ 5.3 (95%CI: 2.4-11.8), LR- 0.09 (95%CI: 0.05-0.14), DOR 74 (95%CI: 34-161). The AUC was 0.95. No significant improvement of the diagnostic accuracy considering PET/CT studies only was found. CONCLUSIONS: (18)F-FDG-PET and PET/CT demonstrated to be accurate diagnostic imaging methods in the differential diagnosis between malignant and benign pleural lesions; nevertheless, possible sources of false-negative and false-positive results should be kept in mind.
Resumo:
PURPOSE: 3'-deoxy-3'-[(18)F]fluorothymidine ([(18)F]FLT), a cell proliferation positron emission tomography (PET) tracer, has been shown in numerous tumors to be more specific than 2-deoxy-2-[(18)F]fluoro-D-glucose ([(18)F]FDG) but less sensitive. We studied the capacity of a nontoxic concentration of 5-fluoro-2'-deoxyuridine (FdUrd), a thymidine synthesis inhibitor, to increase uptake of [(18)F]FLT in tumor xenografts. METHODS: The duration of the FdUrd effect in vivo on tumor cell cycling and thymidine analogue uptake was studied by varying FdUrd pretreatment timing and holding constant the timing of subsequent flow cytometry and 5-[(125)I]iodo-2'-deoxyuridine biodistribution measurements. In [(18)F]FLT studies, FdUrd pretreatment was generally performed 1 h before radiotracer injection. [(18)F]FLT biodistributions were measured 1 to 3 h after radiotracer injection of mice grafted with five different human tumors and pretreated or not with FdUrd and compared with [(18)F]FDG tumor uptake. Using microPET, the dynamic distribution of [(18)F]FLT was followed for 1.5 h in FdUrd pretreated mice. High-field T2-weighted magnetic resonance imaging (MRI) and histology were used comparatively in assessing tumor viability and proliferation. RESULTS: FdUrd induced an immediate increase in tumor uptake of 5-[(125)I]iodo-2'-deoxyuridine, that vanished after 6 h, as also confirmed by flow cytometry. Biodistribution measurements showed that FdUrd pretreatment increased [(18)F]FLT uptake in all tumors by factors of 3.2 to 7.8 compared with controls, while [(18)F]FDG tumor uptake was about fourfold and sixfold lower in breast cancers and lymphoma. Dynamic PET in FdUrd pretreated mice showed that [(18)F]FLT uptake in all tumors increased steadily up to 1.5 h. MRI showed a well-vascularized homogenous lymphoma with high [(18)F]FLT uptake, while in breast cancer, a central necrosis shown by MRI was inactive in PET, consistent with the histomorphological analysis. CONCLUSION: We showed a reliable and significant uptake increase of [(18)F]FLT in different tumor xenografts after low-dose FdUrd pretreatment. These results show promise for a clinical application of FdUrd aimed at increasing the sensitivity of [(18)F]FLT PET.
Resumo:
PURPOSE: 3'-deoxy-3'-[(18)F]fluorothymidine ([(18)F]FLT), a cell proliferation positron emission tomography (PET) tracer, has been shown in numerous tumors to be more specific than 2-deoxy-2-[(18)F]fluoro-D: -glucose ([(18)F]FDG) but less sensitive. We studied the capacity of a nontoxic concentration of 5-fluoro-2'-deoxyuridine (FdUrd), a thymidine synthesis inhibitor, to increase uptake of [(18)F]FLT in tumor xenografts. METHODS: The duration of the FdUrd effect in vivo on tumor cell cycling and thymidine analogue uptake was studied by varying FdUrd pretreatment timing and holding constant the timing of subsequent flow cytometry and 5-[(125)I]iodo-2'-deoxyuridine biodistribution measurements. In [(18)F]FLT studies, FdUrd pretreatment was generally performed 1 h before radiotracer injection. [(18)F]FLT biodistributions were measured 1 to 3 h after radiotracer injection of mice grafted with five different human tumors and pretreated or not with FdUrd and compared with [(18)F]FDG tumor uptake. Using microPET, the dynamic distribution of [(18)F]FLT was followed for 1.5 h in FdUrd pretreated mice. High-field T2-weighted magnetic resonance imaging (MRI) and histology were used comparatively in assessing tumor viability and proliferation. RESULTS: FdUrd induced an immediate increase in tumor uptake of 5-[(125)I]iodo-2'-deoxyuridine, that vanished after 6 h, as also confirmed by flow cytometry. Biodistribution measurements showed that FdUrd pretreatment increased [(18)F]FLT uptake in all tumors by factors of 3.2 to 7.8 compared with controls, while [(18)F]FDG tumor uptake was about fourfold and sixfold lower in breast cancers and lymphoma. Dynamic PET in FdUrd pretreated mice showed that [(18)F]FLT uptake in all tumors increased steadily up to 1.5 h. MRI showed a well-vascularized homogenous lymphoma with high [(18)F]FLT uptake, while in breast cancer, a central necrosis shown by MRI was inactive in PET, consistent with the histomorphological analysis. CONCLUSION: We showed a reliable and significant uptake increase of [(18)F]FLT in different tumor xenografts after low-dose FdUrd pretreatment. These results show promise for a clinical application of FdUrd aimed at increasing the sensitivity of [(18)F]FLT PET.
Resumo:
AIMS: We studied the respective added value of the quantitative myocardial blood flow (MBF) and the myocardial flow reserve (MFR) as assessed with (82)Rb positron emission tomography (PET)/CT in predicting major adverse cardiovascular events (MACEs) in patients with suspected myocardial ischaemia. METHODS AND RESULTS: Myocardial perfusion images were analysed semi-quantitatively (SDS, summed difference score) and quantitatively (MBF, MFR) in 351 patients. Follow-up was completed in 335 patients and annualized MACE (cardiac death, myocardial infarction, revascularization, or hospitalization for congestive heart failure or de novo stable angor) rates were analysed with the Kaplan-Meier method in 318 patients after excluding 17 patients with early revascularizations (<60 days). Independent predictors of MACEs were identified by multivariate analysis. During a median follow-up of 624 days (inter-quartile range 540-697), 35 MACEs occurred. An annualized MACE rate was higher in patients with ischaemia (SDS >2) (n = 105) than those without [14% (95% CI = 9.1-22%) vs. 4.5% (2.7-7.4%), P < 0.0001]. The lowest MFR tertile group (MFR <1.8) had the highest MACE rate [16% (11-25%) vs. 2.9% (1.2-7.0%) and 4.3% (2.1-9.0%), P < 0.0001]. Similarly, the lowest stress MBF tertile group (MBF <1.8 mL/min/g) had the highest MACE rate [14% (9.2-22%) vs. 7.3% (4.2-13%) and 1.8% (0.6-5.5%), P = 0.0005]. Quantitation with stress MBF or MFR had a significant independent prognostic power in addition to semi-quantitative findings. The largest added value was conferred by combining stress MBF to SDS. This holds true even for patients without ischaemia. CONCLUSION: Perfusion findings in (82)Rb PET/CT are strong MACE outcome predictors. MBF quantification has an added value allowing further risk stratification in patients with normal and abnormal perfusion images.