109 resultados para Durable medical equipment
em Université de Lausanne, Switzerland
Resumo:
[Table des matières] Technology assessment in health care in the United States: an historical review / S. Perry. - The aims and methods of technology assessment / JH Glasser. - Evaluation des technologies de la santé / A. Griffiths. - Les données nécessaires pour l'évaluation des technologies médicales / R. Chrzanowski, F. Gutzwiller, F. Paccaud. - Economic issues in technology assessment/DR Lairson, JM Swint. - Two decades of experience in technology assessment: evaluating the safety, performance, and cost effectiveness of medical equipment / JJ Nobel. - Demography and technology assessment / H. Hansluwka. - Méthodes expérimentale et non expérimentale pour l'évaluation des innovations technologiques / R. Chrzanowski, F. Paccaud. - Skull radiography in head trauma: a successful case of technology assessment / NT Racoveanu. - Complications associées à l'anesthésie: une étude prospective en France / L. Tiret et al. - Impact de l'information publique sur les taux opératoires: le cas de l'hystérectomie / G. Domenighetti, P. Luraschi, A. Casabianca. - The clinical effectiveness of acupuncture for the relief of chronic pain / MS Patel, F. Gutzwiller, F. Paccaud, A. Marazzi. - Soins à domicile et hébergement à long terme: à la recherche d'un développement optimum / G. Tinturier. - Economic evaluation of six scenarios for the treatment of stones in the kidney and ureter by surgery or ESWL / MS Patel et al. - Technology assessment and medical practice / F. Gutzwiller. - Technology assessment and health policy / SJ Reiser. - Global programme on appropriate technology for health, its role and place within WHO / K. Staehr Johansen.
Resumo:
Every medical practitioner is confronted on a daily basis with emergencies. Among these, life-threatening emergencies can have disastrous consequences in term of morbidity and mortality; 22 cardiac arrests and 10 deaths were reported among the 1,650 Swiss practices during a 5 year period. The occurrence of life-threatening emergencies at the office necessitates, according to the type and place of the practice, the skills of the practitioner and the organization of his practice, the implementation of procedures, equipments (for example room equipped with a defibrillator, respiratory nebulizer, splints, emergency drugs) and specific continuous education programs that should be encouraged and made available to the whole medical corporation.
Resumo:
OBJECTIVE: The occurrence of the 2003 G8 summit in Evian and the threat of major civil riots or even terrorist attacks in the Swiss neighbourhood forced us to imagine a new system of rescue and medical care in case of numerous victims. Previous occurrences of the G8 in Europe or America have demonstrated the need of flexible and mobile structures, able to respond quickly to crowd movements, unlike the usual static structure of rescue systems designed for major accidents. METHODS: We developed a new concept of Mobile Medical Squadrons (MMS) consisting of several vehicles and medical care and rescue human resources. In our concept, each MMS consisted of 3 emergency doctors, 5 paramedics and 9 first-aid workers. They were designed to handle 15 patients, with a large autonomy in terms of rescue, medical care, evacuation and medical authority. The equipment included medical, resuscitation, simple decontamination, evacuation and communication materials. RESULTS: The MMS were dispatched four times during the G8 summit following civil riots. They took care of 12 injured patients. CONCLUSION: The concept of MMS as a reinforcement of the existing rescue and health care resources appears as a new flexible, a modular and useful concept for the medical management of collective prehospital emergency situations. Its use is suggested instead of the traditional static concept of rescue systems designed for major accidents.
Resumo:
BACKGROUND: Infliximab (IFX) has been used for over a decade worldwide. Less is known about the natural history of IFX use beyond a few years and which patients are more likely to sustain benefits. METHODS: Patients with Crohn's disease (CD) exposed to IFX from Massachusetts General Hospital, Boston, Saint-Antoine Hospital, Paris, and the Swiss IBD Cohort Study were identified through retrospective and prospective data collection, complemented by chart abstraction of electronic medical records. We compared long-term users of IFX (>5 yr of treatment, long-term users of infliximab [LTUI]), with non-LTUI patients to identify prognostic factors. RESULTS: We pooled data on 1014 patients with CD from 3 different databases, of whom 250 were defined as LTUI. The comparison group comprised 290 patients with CD who discontinued IFX: 48 primary nonresponses, 95 loss of responses, and 147 adverse events. Factors associated with LTUI were colonic involvements and an earlier age at the start of IFX. The prevalence of active smokers and obese patients differed markedly, but inversely, between American and European centers but did not impact outcome. The discontinuation rate was stable around 3% to 6%, each year from years 3 to 10. CONCLUSIONS: Young age at start of IFX and colonic CD are factors associated with a beneficial long-term use of IFX. After 5 years of IFX, there is still a 3% to 5% discontinuation rate annually. Several factors associated with a good initial response such as nonsmoker and shorter disease duration at IFX initiation do not seem associated with a longer term response.
Resumo:
BACKGROUND/OBJECTIVES: This study aims to assess whether patent foramen ovale (PFO) closure is superior to medical therapy in preventing recurrence of cryptogenic ischemic stroke or transient ischemic attack (TIA). METHODS: We searched PubMed for randomized trials which compared PFO closure with medical therapy in cryptogenic stroke/TIA using the items: "stroke or cerebrovascular accident or TIA" and "patent foramen ovale or paradoxical embolism" and "trial or study". RESULTS: Among 650 potentially eligible articles, 3 were included including 2303 patients. There was no statistically significant difference between PFO-closure and medical therapy in ischemic stroke recurrence (1.91% vs. 2.94% respectively, OR: 0.64, 95%CI: 0.37-1.10), TIA (2.08% vs. 2.42% respectively, OR: 0.87, 95%CI: 0.50-1.51) and death (0.60% vs. 0.86% respectively, OR: 0.71, 95%CI: 0.28-1.82). In subgroup analysis, there was significant reduction of ischemic strokes in the AMPLATZER PFO Occluder arm vs. medical therapy (1.4% vs. 3.04% respectively, OR: 0.46, 95%CI: 0.21-0.98, relative-risk-reduction: 53.2%, absolute-risk-reduction: 1.6%, number-needed-to-treat: 61.8) but not in the STARFlex device (2.7% vs. 2.8% with medical therapy, OR: 0.93, 95%CI: 0.45-2.11). Compared to medical therapy, the number of patients with new-onset atrial fibrillation (AF) was similar in the AMPLATZER PFO Occluder arm (0.72% vs. 1.28% respectively, OR: 1.81, 95%CI: 0.60-5.42) but higher in the STARFlex device (0.64% vs. 5.14% respectively, OR: 8.30, 95%CI: 2.47-27.84). CONCLUSIONS: This meta-analysis does not support PFO closure for secondary prevention with unselected devices in cryptogenic stroke/TIA. In subgroup analysis, selected closure devices may be superior to medical therapy without increasing the risk of new-onset AF, however. This observation should be confirmed in further trials using inclusion criteria for patients with high likelihood of PFO-related stroke recurrence.
Resumo:
BACKGROUND: Robot surgery is a further step towards new potential developments in minimally invasive surgery. Surgeons must keep abreast of these new technologies and learn their limits and possibilities. Robot-assisted laparoscopic cholecystectomy has not yet been performed in our institution. The purpose of this report is to present the pathway of implementation of robotic laparoscopic cholecystectomy in a university hospital. METHODS: The Zeus(R) robot system was used. Experimental training was performed on animals. The results of our experimental training allowed us to perform our first two clinical cases. RESULTS: Robot arm set-up and trocar placement required 53 and 35 minutes. Operative time were 59 and 45 minutes respectively. The overall operative time was 112 and 80 minutes, respectively. There were no intraoperative complications. Patients were discharged from the hospital after an overnight stay. CONCLUSION: Robotic laparoscopic cholecystectomy is safe and patient recovery similar to those of standard laparoscopy. At present, there are no advantages of robotic over conventional surgery. Nevertheless, robots have the potential to revolutionise the way surgery is performed. Robot surgery is not reserved for a happy few. This technology deserves more attention because it has the potential to change the way surgery is performed.
Resumo:
OBJECTIVE: To examine the effectiveness of motivational interviewing (MI) training among medical students. METHODS: All students (n=131) (year 5) at Lausanne Medical School, Switzerland were randomized into an experimental or a control group. After a training in basic communication skills (control condition), an 8-h MI training was completed by 84.8% students in the exprimental group. One week later, students in both groups were invited to meet with two standardized patients. MI skills were coded by blinded research assistants using the Motivational Interviewing Treatment Integrity 3.0. RESULTS: Superior MI performance was shown for trained versus control students, as demonstrated by higher scores for "Empathy" [p<0.001] and "MI Spirit" [p<0.001]. Scores were similar between groups for "Direction", indicating that students in both groups invited the patient to talk about behavior change. Behavior counts assessment demonstrated better performance in MI in trained versus untrained students regarding occurences of MI-adherent behavior [p<0.001], MI non-adherent behavior [p<0.001], Closed questions [p<0.001], Open questions [p=0.001], simple reflections [p=0.03], and Complex reflections [p<0.001]. Occurrences were similar between groups regarding "Giving information". CONCLUSION: An 8-h training workshop was associated with improved MI performance. PRACTICE IMPLICATIONS: These findings lend support for the implementation of MI training in medical schools.