13 resultados para Distribuito, Modello, Attori, Software, quality, Scalabilità

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose a new approach and related indicators for globally distributed software support and development based on a 3-year process improvement project in a globally distributed engineering company. The company develops, delivers and supports a complex software system with tailored hardware components and unique end-customer installations. By applying the domain knowledge from operations management on lead time reduction and its multiple benefits to process performance, the workflows of globally distributed software development and multitier support processes were measured and monitored throughout the company. The results show that the global end-to-end process visibility and centrally managed reporting at all levels of the organization catalyzed a change process toward significantly better performance. Due to the new performance indicators based on lead times and their variation with fixed control procedures, the case company was able to report faster bug-fixing cycle times, improved response times and generally better customer satisfaction in its global operations. In all, lead times to implement new features and to respond to customer issues and requests were reduced by 50%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rigorous organization and quality control (QC) are necessary to facilitate successful genome-wide association meta-analyses (GWAMAs) of statistics aggregated across multiple genome-wide association studies. This protocol provides guidelines for (i) organizational aspects of GWAMAs, and for (ii) QC at the study file level, the meta-level across studies and the meta-analysis output level. Real-world examples highlight issues experienced and solutions developed by the GIANT Consortium that has conducted meta-analyses including data from 125 studies comprising more than 330,000 individuals. We provide a general protocol for conducting GWAMAs and carrying out QC to minimize errors and to guarantee maximum use of the data. We also include details for the use of a powerful and flexible software package called EasyQC. Precise timings will be greatly influenced by consortium size. For consortia of comparable size to the GIANT Consortium, this protocol takes a minimum of about 10 months to complete.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Images obtained from high-throughput mass spectrometry (MS) contain information that remains hidden when looking at a single spectrum at a time. Image processing of liquid chromatography-MS datasets can be extremely useful for quality control, experimental monitoring and knowledge extraction. The importance of imaging in differential analysis of proteomic experiments has already been established through two-dimensional gels and can now be foreseen with MS images. We present MSight, a new software designed to construct and manipulate MS images, as well as to facilitate their analysis and comparison.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of copper (Cu) filtration on image quality and dose in different digital X-ray systems was investigated. Two computed radiography systems and one digital radiography detector were used. Three different polymethylmethacrylate blocks simulated the pediatric body. The effect of Cu filters of 0.1, 0.2, and 0.3 mm thickness on the entrance surface dose (ESD) and the corresponding effective doses (EDs) were measured at tube voltages of 60, 66, and 73 kV. Image quality was evaluated in a contrast-detail phantom with an automated analyzer software. Cu filters of 0.1, 0.2, and 0.3 mm thickness decreased the ESD by 25-32%, 32-39%, and 40-44%, respectively, the ranges depending on the respective tube voltages. There was no consistent decline in image quality due to increasing Cu filtration. The estimated ED of anterior-posterior (AP) chest projections was reduced by up to 23%. No relevant reduction in the ED was noted in AP radiographs of the abdomen and pelvis or in posterior-anterior radiographs of the chest. Cu filtration reduces the ESD, but generally does not reduce the effective dose. Cu filters can help protect radiosensitive superficial organs, such as the mammary glands in AP chest projections.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Quality assurance (QA) in clinical trials is essential to ensure treatment is safely and effectively delivered. As QA requirements have increased in complexity in parallel with evolution of radiation therapy (RT) delivery, a need to facilitate digital data exchange emerged. Our objective is to present the platform developed for the integration and standardization of QART activities across all EORTC trials involving RT. METHODS: The following essential requirements were identified: secure and easy access without on-site software installation; integration within the existing EORTC clinical remote data capture system; and the ability to both customize the platform to specific studies and adapt to future needs. After retrospective testing within several clinical trials, the platform was introduced in phases to participating sites and QART study reviewers. RESULTS: The resulting QA platform, integrating RT analysis software installed at EORTC Headquarters, permits timely, secure, and fully digital central DICOM-RT based data review. Participating sites submit data through a standard secure upload webpage. Supplemental information is submitted in parallel through web-based forms. An internal quality check by the QART office verifies data consistency, formatting, and anonymization. QART reviewers have remote access through a terminal server. Reviewers evaluate submissions for protocol compliance through an online evaluation matrix. Comments are collected by the coordinating centre and institutions are informed of the results. CONCLUSIONS: This web-based central review platform facilitates rapid, extensive, and prospective QART review. This reduces the risk that trial outcomes are compromised through inadequate radiotherapy and facilitates correlation of results with clinical outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose of the study: Basic life support (BLS) and automated externaldefibrillation (AED) represent important skills to be acquired duringpregraduate medical training. Since 3 years, our medical school hasintroduced a BLS-AED course (with certification) for all second yearmedical students. Few reports about quality and persistence over timeof BLS-AED learning are available to date in the medical literature.Comprehensive evaluation of students' acquired skills was performedat the end of the 2008 academic year, 6 month after certification.Materials and methods: The students (N = 142) were evaluated duringa 9 minutes «objective structured clinical examination» (OSCE) station.Out of a standardized scenario, they had to recognize a cardiac arrestsituation and start a resuscitation process. Their performance wererecorded on a PC using an Ambuman(TM) mannequin and the AmbuCPR software kit(TM) during a minimum of 8 cycles (30 compressions:2 ventilations each). BLS parameters were systematically checked. Nostudent-rater interactions were allowed during the whole evaluation.Results: Response of the victim was checked by 99% of the students(N = 140), 96% (N = 136) called for an ambulance and/or an AED. Openthe airway and check breathing were done by 96% (N = 137), 92% (N =132) gave 2 rescue breaths. Pulse was checked by 95% (N=135), 100%(N = 142) begun chest compression, 96% (N = 136) within 1 minute.Chest compression rate was 101 ± 18 per minute (mean ± SD), depthcompression 43 ± 8 mm, 97% (N = 138) respected a compressionventilationratio of 30:2.Conclusions: Quality of BLS skills acquisition is maintained during a6-month period after a BLS-AED certification. Main targets of 2005 AHAguidelines were well respected. This analysis represents one of thelargest evaluations of specific BLS teaching efficiency reported. Furtherfollow-up is needed to control the persistence of these skills during alonger time period and noteworthy at the end of the pregraduatemedical curriculum.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Percutaneous transluminal renal angioplasty (PTRA) is an invasive technique that is costly and involves the risk of complications and renal failure. The ability of PTRA to reduce the administration of antihypertensive drugs has been demonstrated. A potentially greater benefit, which nevertheless remains to be proven, is the deferral of the need for chronic dialysis. The aim of the study (ANPARIA) was to assess the appropriateness of PTRA to impact on the evolution of renal function. A standardized expert panel method was used to assess the appropriateness of medical treatment alone or medical treatment with revascularization in various clinical situations. The choice of revascularization by either PTRA or surgery was examined for each clinical situation. Analysis was based on a detailed literature review and on systematically elicited expert opinion, which were obtained during a two-round modified Delphi process. The study provides detailed responses on the appropriateness of PTRA for 1848 distinct clinical scenarios. Depending on the major clinical presentation, appropriateness of revascularization varied from 32% to 75% for individual scenarios (overal 48%). Uncertainty as to revascularization was 41% overall. When revascularization was appropriate, PTRA was favored over surgery in 94% of the scenarios, except in certain cases of aortic atheroma where sugery was the preferred choice. Kidney size [7 cm, absence of coexisting disease, acute renal failure, a high degree of stenosis (C70%), and absence of multiple arteries were identified as predictive variables of favorable appropriateness ratings. Situations such as cardiac failure with pulmonary edema or acute thrombosis of the renal artery were defined as indications for PTRA. This study identified clinical situations in which PTRA or surgery are appropriate for renal artery disease. We built a decision tree which can be used via Internet: the ANPARIA software (http://www.chu-clermontferrand.fr/anparia/). In numerous clinical situations uncertainty remains as to whether PTRA prevents deterioration of renal function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: IOL centration and stability after cataract surgery is of high interest for cataract surgeons and IOL-producing companies. We present a new imaging software to evaluate the centration of the rhexis and the centration of the IOL after cataract surgery.Methods: We developed, in collaboration with the Biomedical Imaging Group (BIG), EPFL, Lausanne, a new working tool in order to assess precisely outcomes after IOL-implantation, such as ideal capsulorhexis and IOL-centration. The software is a plug-in of ImageJ, a general-purpose image processing and image-analysis package. The specifications of this software are: evaluation of the rhexis-centration and evaluation the position of the IOL in the posterior chamber. The end points are to analyze the quality of the centration of a rhexis after cataract surgery, the deformation of the rhexis with capsular bag retraction and the centration of the IOL after implantation.Results: This software delivers tools to interactively measure the distances between limbus, IOL and capsulorhexis and its changes over time. The user is invited to adjust nodes of three radial curves for the limbus, rhexis and the optic of the IOL. The radial distances of the curves are computed to evaluate the IOL implantation. The user is also able to define patterns for ideal capsulorhexis and optimal IOL-centration. We are going to present examples of calculations after cataract surgery.Conclusions: Evaluation of the centration of the rhexis and of the IOL after cataract surgery is an important end point for optimal IOL implantation after cataract surgery. Especially multifocal or accommodative lenses need a precise position in the bag with a good stability over time. This software is able to evaluate these parameters just after the surgery but also its changes over time. The results of these evaluations can lead to an optimizing of surgical procedures and materials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: The EORTC 22043-30041 trial investigates the role of the addition of androgen suppression to post-operative radiotherapy in patients who have undergone radical prostatectomy. As part of the quality assurance of radiotherapy (QART) a Dummy Run (DR) procedure was performed. MATERIALS AND METHOD: The protocol included detailed and published delineation guidelines. Participating institutions digitally submitted radiotherapy treatment volumes and a treatment plan for a standard clinical case. Submissions were centrally reviewed using the VODCA software platform. RESULTS: Thirty-eight submissions from thirty-one institutions were reviewed. Six were accepted without comments. Twenty-three were accepted with comments on one or more items: target volume delineation (22), OAR delineation (23), planning and dosimetry (3) or treatment verification (1). Nine submissions were rejected requiring resubmission, seven for target volume delineation reasons alone. Intervention to highlight the importance of delineation guidelines was made prior to the entry of the first patient in the trial. After this, a lower percentage of resubmissions was required. CONCLUSIONS: The EORTC 22043-30041 Dummy Run highlights the need for timely and effective QART in clinical trials. The variation in target volume and OAR definition demonstrates that clinical guidelines and radiotherapy protocols are not a substitute for QART procedures. Early intervention in response to the Dummy Run improved protocol understanding.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent technological progress has greatly facilitated de novo genome sequencing. However, de novo assemblies consist in many pieces of contiguous sequence (contigs) arranged in thousands of scaffolds instead of small numbers of chromosomes. Confirming and improving the quality of such assemblies is critical for subsequent analysis. We present a method to evaluate genome scaffolding by aligning independently obtained transcriptome sequences to the genome and visually summarizing the alignments using the Cytoscape software. Applying this method to the genome of the red fire ant Solenopsis invicta allowed us to identify inconsistencies in 7%, confirm contig order in 20% and extend 16% of scaffolds.Scripts that generate tables for visualization in Cytoscape from FASTA sequence and scaffolding information files are publicly available at https://github.com/ksanao/TGNet.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose of the study: Basic life support (BLS) and automated externaldefibrillation (AED) represent important skills to be acquired duringpregraduate medical training. Since 3 years, our medical school hasintroduced a BLS-AED course (with certification) for all second yearmedical students. Few reports about quality and persistence over timeof BLS-AED learning are available to date in the medical literature.Comprehensive evaluation of students' acquired skills was performedat the end of the 2008 academic year, 6 month after certification.Materials and methods: The students (N = 142) were evaluated duringa 9 minutes «objective structured clinical examination» (OSCE) station.Out of a standardized scenario, they had to recognize a cardiac arrestsituation and start a resuscitation process. Their performance wererecorded on a PC using an Ambuman(TM) mannequin and the AmbuCPR software kit(TM) during a minimum of 8 cycles (30 compressions:2 ventilations each). BLS parameters were systematically checked. Nostudent-rater interactions were allowed during the whole evaluation.Results: Response of the victim was checked by 99% of the students(N = 140), 96% (N = 136) called for an ambulance and/or an AED. Openthe airway and check breathing were done by 96% (N = 137), 92% (N =132) gave 2 rescue breaths. Pulse was checked by 95% (N=135), 100%(N = 142) begun chest compression, 96% (N = 136) within 1 minute.Chest compression rate was 101 ± 18 per minute (mean ± SD), depthcompression 43 ± 8 mm, 97% (N = 138) respected a compressionventilationratio of 30:2.Conclusions: Quality of BLS skills acquisition is maintained during a6-month period after a BLS-AED certification. Main targets of 2005 AHAguidelines were well respected. This analysis represents one of thelargest evaluations of specific BLS teaching efficiency reported. Furtherfollow-up is needed to control the persistence of these skills during alonger time period and noteworthy at the end of the pregraduatemedical curriculum.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Imaging during a period of minimal myocardial motion is of paramount importance for coronary MR angiography (MRA). The objective of our study was to evaluate the utility of FREEZE, a custom-built automated tool for the identification of the period of minimal myocardial motion, in both a moving phantom at 1.5 T and 10 healthy adults (nine men, one woman; mean age, 24.9 years; age range, 21-32 years) at 3 T. CONCLUSION: Quantitative analysis of the moving phantom showed that dimension measurements approached those obtained in the static phantom when using FREEZE. In vitro, vessel sharpness, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were significantly improved when coronary MRA was performed during the software-prescribed period of minimal myocardial motion (p < 0.05). Consistent with these objective findings, image quality assessments by consensus review also improved significantly when using the automated prescription of the period of minimal myocardial motion. The use of FREEZE improves image quality of coronary MRA. Simultaneously, operator dependence can be minimized while the ease of use is improved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

MRI has evolved into an important diagnostic technique in medical imaging. However, reliability of the derived diagnosis can be degraded by artifacts, which challenge both radiologists and automatic computer-aided diagnosis. This work proposes a fully-automatic method for measuring image quality of three-dimensional (3D) structural MRI. Quality measures are derived by analyzing the air background of magnitude images and are capable of detecting image degradation from several sources, including bulk motion, residual magnetization from incomplete spoiling, blurring, and ghosting. The method has been validated on 749 3D T(1)-weighted 1.5T and 3T head scans acquired at 36 Alzheimer's Disease Neuroimaging Initiative (ADNI) study sites operating with various software and hardware combinations. Results are compared against qualitative grades assigned by the ADNI quality control center (taken as the reference standard). The derived quality indices are independent of the MRI system used and agree with the reference standard quality ratings with high sensitivity and specificity (>85%). The proposed procedures for quality assessment could be of great value for both research and routine clinical imaging. It could greatly improve workflow through its ability to rule out the need for a repeat scan while the patient is still in the magnet bore.