27 resultados para Didactic laboratory of physics
em Université de Lausanne, Switzerland
Resumo:
In this paper the rift between Jevons and Mill over the method of political economy serves as a prehistory to recent attempts of behavioural economists to once again explain economic behaviour by taking recourse to mankind's physiology. While Mill relied on the association psychology and its introspective method to establish indubitable first principles, Jevons scorned all recourse to introspection. As exemplified for Jevons's theory of labour, psychophysiology gave Jevons the means to think about economic behaviour in terms of functional form, and promised its assessment by means of experiments. Thus levelling down the Victorian distinction between mind and matter, Jevons turned political economy into social physics.
Resumo:
OBJECTIVE: : To determine the influence of nebulizer types and nebulization modes on bronchodilator delivery in a mechanically ventilated pediatric lung model. DESIGN: : In vitro, laboratory study. SETTING: : Research laboratory of a university hospital. INTERVENTIONS: : Using albuterol as a marker, three nebulizer types (jet nebulizer, ultrasonic nebulizer, and vibrating-mesh nebulizer) were tested in three nebulization modes in a nonhumidified bench model mimicking the ventilatory pattern of a 10-kg infant. The amounts of albuterol deposited on the inspiratory filters (inhaled drug) at the end of the endotracheal tube, on the expiratory filters, and remaining in the nebulizers or in the ventilator circuit were determined. Particle size distribution of the nebulizers was also measured. MEASUREMENTS AND MAIN RESULTS: : The inhaled drug was 2.8% ± 0.5% for the jet nebulizer, 10.5% ± 2.3% for the ultrasonic nebulizer, and 5.4% ± 2.7% for the vibrating-mesh nebulizer in intermittent nebulization during the inspiratory phase (p < 0.01). The most efficient nebulizer was the vibrating-mesh nebulizer in continuous nebulization (13.3% ± 4.6%, p < 0.01). Depending on the nebulizers, a variable but important part of albuterol was observed as remaining in the nebulizers (jet and ultrasonic nebulizers), or being expired or lost in the ventilator circuit (all nebulizers). Only small particles (range 2.39-2.70 µm) reached the end of the endotracheal tube. CONCLUSIONS: : Important differences between nebulizer types and nebulization modes were seen for albuterol deposition at the end of the endotracheal tube in an in vitro pediatric ventilator-lung model. New aerosol devices, such as ultrasonic and vibrating-mesh nebulizers, were more efficient than the jet nebulizer.
Resumo:
Hypoglycaemia is a major cause of neonatal morbidity and may induce long-term developmental sequelae. Clinical signs of hypoglycaemia in neonatal infants are unspecific or even absent, and therefore, precise and accurate methods for the assessment of glycaemia are needed. Glycaemia measurement in newborns has some particularities like a very low limit of normal glucose concentration compared to adults and a large range of normal haematocrit values. Many bedside point-of-care testing (POCT) systems are available, but literature about their accuracy in newborn infants is scarce and not very convincing. In this retrospective study, we identified over a 1-year study period 1,324 paired glycaemia results, one obtained at bedside with one of three different POCT systems (Elite? XL, Ascensia? Contour? and ABL 735) and the other in the central laboratory of the hospital with the hexokinase reference method. All three POCT systems tended to overestimate glycaemia values, and none of them fulfilled the ISO 15197 accuracy criteria. The Elite XL appeared to be more appropriate than Contour to detect hypoglycaemia, however with a low specificity. Contour additionally showed an important inaccuracy with increasing haematocrit. The bench analyzer ABL 735 was the most accurate of the three tested POCT systems. Both of the tested handheld glucometers have important drawbacks in their use as screening tools for hypoglycaemia in newborn infants. ABL 735 could be a valuable alternative, but the blood volume needed is more than 15 times higher than for handheld glucometers. Before daily use in the newborn population, careful clinical evaluation of each new POCT system for glucose measurement is of utmost importance.
Resumo:
BACKGROUND: Within the frame of a twinning programme with Nicaragua, The La Mascota project, we evaluated in our study the contribution of cytogenetic characterization of acute lymphoblastic leukemia (ALL) as prognostic factor compared to clinical, morphological, and immunohistochemical parameters. METHODS: All patients with ALL treated at the only cancer pediatric hospital in Nicaragua during 2006 were studied prospectively. Diagnostic immunophenotyping was performed locally and bone marrow or blood samples were sent to the cytogenetic laboratory of Zurich for fluorescence in situ hybridization (FISH) analysis and G-banding. RESULTS: Sixty-six patients with ALL were evaluated. Their mean age at diagnosis was 7.3 years, 31.8% were >or=10 years. Thirty-four patients (51.5%) presented with hyperleucocytosis >or=50 x 10(9)/L, 45 (68.2%) had hepatosplenomegaly. Immunophenotypically 63/66 patients (95%) had a B-precursor, 2 (3%) a T- and 1 (1.5%) a B-mature ALL. FISH analysis demonstrated a TEL/AML1 fusion in 9/66 (14%), BCR/ABL fusion in 1 (1.5%), MLL rearrangement in 2 (3.1%), iAMP21 in 2 (3.1%), MYC rearrangement in 1 (1.5%), and high-hyperdiploidy in 16 (24%). All patients but two with TEL/AML1 fusion and high-hyperdiploidy were clinically and hematologically in the standard risk group whereas those with poor cytogenetic factors had clinical high-risk features and were treated intensively. CONCLUSIONS: Compared to Europe, the ALL population in Nicaragua is older, has a higher proportion of poor prognostic clinical and hematological features and receives more intensive treatment, while patients with TEL/AML1 translocations and high-hyperdiploidy are clinically in the standard risk group. Cytogenetics did not contribute as an additional prognostic factor in this setting.
Resumo:
In this paper, we study the average crossing number of equilateral random walks and polygons. We show that the mean average crossing number ACN of all equilateral random walks of length n is of the form . A similar result holds for equilateral random polygons. These results are confirmed by our numerical studies. Furthermore, our numerical studies indicate that when random polygons of length n are divided into individual knot types, the for each knot type can be described by a function of the form where a, b and c are constants depending on and n0 is the minimal number of segments required to form . The profiles diverge from each other, with more complex knots showing higher than less complex knots. Moreover, the profiles intersect with the ACN profile of all closed walks. These points of intersection define the equilibrium length of , i.e., the chain length at which a statistical ensemble of configurations with given knot type -upon cutting, equilibration and reclosure to a new knot type -does not show a tendency to increase or decrease . This concept of equilibrium length seems to be universal, and applies also to other length-dependent observables for random knots, such as the mean radius of gyration Rg.
Resumo:
It is a common macroscopic observation that knotted ropes or fishing lines under tension easily break at the knot. However, a more precise localization of the breakage point in knotted macroscopic strings is a difficult task. In the present work, the tightening of knots was numerically simulated, a comparison of strength of different knots was experimentally performed and a high velocity camera was used to precisely localize the site where knotted macroscopic strings break. In the case of knotted spaghetti, the breakage occurs at the position with high curvature at the entry to the knot. This localization results from joint contributions of loading, bending and friction forces into the complex process of knot breakage. The present simulations and experiments are in agreement with recent molecular dynamics simulations of a knotted polymer chain and with experiments performed on actin and DNA filaments. The strength of the knotted string is greatly reduced (down to 50%) by the presence of a knot, therefore reducing the resistance to tension of all materials containing chains of any sort. The present work with macroscopic strings revels some important aspects, which are not accessible by experiments with microscopic chains.
Resumo:
Inspired by experiments that use single-particle tracking to measure the regions of confinement of selected chromosomal regions within cell nuclei, we have developed an analytical approach that takes into account various possible positions and shapes of the confinement regions. We show, in particular, that confinement of a particle into a subregion that is entirely enclosed within a spherical volume can lead to a higher limit of the mean radial square displacement value than the one associated with a particle that can explore the entire spherical volume. Finally, we apply the theory to analyse the motion of extrachromosomal chromatin rings within nuclei of living yeast.
Resumo:
Probably the most natural energy functional to be considered for knotted strings is that given by electrostatic repulsion. In the absence of counter-charges, a charged, knotted string evolving along the energy gradient of electrostatic repulsion would progressively tighten its knotted domain into a point on a perfectly circular string. However, in the presence of charge screening self-repelling knotted strings can be stabilized. It is known that energy functionals in which repulsive forces between repelling charges grow inversely proportionally to the third or higher power of their relative distance stabilize self-repelling knots. Especially interesting is the case of the third power since the repulsive energy becomes scale invariant and does not change upon Mobius transformations (reflections in spheres) of knotted trajectories. We observe here that knots minimizing their repulsive Mobius energy show quantization of the energy and writhe (measure of chirality) within several tested families of knots.
Resumo:
Delayed-choice experiments in quantum mechanics are often taken to undermine a realistic interpretation of the quantum state. More specifically, Healey has recently argued that the phenomenon of delayed-choice entanglement swapping is incompatible with the view that entanglement is a physical relation between quantum systems. This paper argues against these claims. It first reviews two paradigmatic delayed-choice experiments and analyzes their metaphysical implications. It then applies the results of this analysis to the case of entanglement swapping, showing that such experiments pose no threat to realism about entanglement.
Resumo:
PURPOSE: Recent work practices in the conservation and restoration involve the use of cyclododecane (CDD, CAS 294-62-2) to protect fragile artifacts during their handling or transportation. Little is known about its toxicity, and no previous exposure has been reported. A short field investigation was conducted to characterize the exposure conditions to both CDD vapors and aerosols.METHODS: Measurements were conducted in the laboratory of conservation and restoration of the archeological service in Bern (Switzerland). Three indoor and four outdoor typical work situations, either during brush or spray gun applications, were investigated. Measurements were performed on charcoal adsorbent tube and analyzed by a gas chromatograph equipped with a flame ionization detector.RESULTS: Measurements have been conducted during both brush and spray gun applications. Indoor exposures were of 0.75-15.5 mg/m(3), while outdoors exposures were 19.5-53.9 mg/m(3). Exposures appear to be extremely localized due to both physicochemical properties and application methods of the CDD. Vapor exposure increases dramatically with the confinement of the workplace.CONCLUSION: Preventive measures should be undertaken to limit as much as possible these exposures. Field work in confined areas (ditches, underground) is of particular concern. CDD-coated artifacts or materials should be stored in ventilated areas to avoid delayed exposures. [Authors]
Resumo:
Gel electrophoresis can be used to separate nicked circular DNA molecules of equal length but forming different knot types. At low electric fields, complex knots drift faster than simpler knots. However, at high electric field the opposite is the case and simpler knots migrate faster than more complex knots. Using Monte Carlo simulations we investigate the reasons of this reversal of relative order of electrophoretic mobility of DNA molecules forming different knot types. We observe that at high electric fields the simulated knotted molecules tend to hang over the gel fibres and require passing over a substantial energy barrier to slip over the impeding gel fibre. At low electric field the interactions of drifting molecules with the gel fibres are weak and there are no significant energy barriers that oppose the detachment of knotted molecules from transverse gel fibres.
Resumo:
BACKGROUND: Within the frame of a twinning programme with Nicaragua, The La Mascota project, we evaluated in our study the contribution of cytogenetic characterization of acute lymphoblastic leukemia (ALL) as prognostic factor compared to clinical, morphological, and immunohistochemical parameters. METHODS: All patients with ALL treated at the only cancer pediatric hospital in Nicaragua during 2006 were studied prospectively. Diagnostic immunophenotyping was performed locally and bone marrow or blood samples were sent to the cytogenetic laboratory of Zurich for fluorescence in situ hybridization (FISH) analysis and G-banding. RESULTS: Sixty-six patients with ALL were evaluated. Their mean age at diagnosis was 7.3 years, 31.8% were >or=10 years. Thirty-four patients (51.5%) presented with hyperleucocytosis >or=50 x 10(9)/L, 45 (68.2%) had hepatosplenomegaly. Immunophenotypically 63/66 patients (95%) had a B-precursor, 2 (3%) a T- and 1 (1.5%) a B-mature ALL. FISH analysis demonstrated a TEL/AML1 fusion in 9/66 (14%), BCR/ABL fusion in 1 (1.5%), MLL rearrangement in 2 (3.1%), iAMP21 in 2 (3.1%), MYC rearrangement in 1 (1.5%), and high-hyperdiploidy in 16 (24%). All patients but two with TEL/AML1 fusion and high-hyperdiploidy were clinically and hematologically in the standard risk group whereas those with poor cytogenetic factors had clinical high-risk features and were treated intensively. CONCLUSIONS: Compared to Europe, the ALL population in Nicaragua is older, has a higher proportion of poor prognostic clinical and hematological features and receives more intensive treatment, while patients with TEL/AML1 translocations and high-hyperdiploidy are clinically in the standard risk group. Cytogenetics did not contribute as an additional prognostic factor in this setting.
Resumo:
Laudisa (Found. Phys. 38:1110-1132, 2008) claims that experimental research on the class of non-local hidden-variable theories introduced by Leggett is misguided, because these theories are irrelevant for the foundations of quantum mechanics. I show that Laudisa's arguments fail to establish the pessimistic conclusion he draws from them. In particular, it is not the case that Leggett-inspired research is based on a mistaken understanding of Bell's theorem, nor that previous no-hidden-variable theorems already exclude Leggett's models. Finally, I argue that the framework of Bohmian mechanics brings out the importance of Leggett tests, rather than proving their irrelevance, as Laudisa supposes.