201 resultados para Descending toracic aorta

em Université de Lausanne, Switzerland


Relevância:

80.00% 80.00%

Publicador:

Resumo:

We report on a patient with Marfan syndrome who presented a Stanford type B dissection of the descending thoracic aorta in late pregnancy. After a cesarean section, the patient presented a severe obstruction of the mesenteric superior artery. An endovascular fenestration was performed (balloon and guidewire based fenestration). Computed tomography (CT) angiography revealed an intussusception 'like' image of the abdominal aortic layers as a consequence of the fenestration procedure. Because of aneurismal progression in the abdominal aorta, surgical repair of the abdominal aorta and intussusception material removal was achieved six weeks later. The patient is currently in good condition. We conclude that the intussusception could be induced by a guidewire. This fenestration procedure is not recommended in patients with structural aortic disorders.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: A hybrid intervention is a joint procedure involving the interventional cardiologist and the cardiac surgeon. At our institution we have opted for this type of approach in congenital heart disease since 2005. We report here our initial experience. Cases: 1. A 3 year old boy with double aortic arch and multiple muscular ventricular septal defects (VSD),was readdressed for pulmonary band (PAB) removal and residual VSD closure after previous palliation. After surgical removal of the PAB, the surgeon provided a minimal transventricular access for placement of a 6mm Amplatzer® muscular VSD occluder by the cardiologist under transoesophageal guidance. The patient was extubated the same day and discharged after 5 days. 2. An 8 year old girl with Williams syndrome was followed for two large VSDs and severe peripheral pulmonary arteries (PA) stenosis. The membranous VSD was closed surgically, the muscular VSD during the same operation by direct placement of a 12 mm Amplatzer® muscular VSD occluder. During rewarming, balloon angioplasty of peripheral PA stenosis was achieved under fluoroscopy. Patient was extubated the following day and discharged after 8 days. 3. A 9 year old boy post tetralogy of Fallot repair had severe distal stenosis of the right ventricular to PA conduit.With patient on partial cardiopulmonary bypass, an incision was made on the conduit and a CP 8 Zig 16 stent placed on the stenosis. The child passed on full bypass and the definitive placement of the stent achieved. The child was extubated at the end of the intervention and discharged after 6 days. 4. A newborn presented at 2 days life with complex aortic arch anatomy: left aortic arch and right descending thoracic aorta perfused directly from a right arterial duct and left PA atresia. The arterial duct was stented with a Genesis XD stent dilated at 7mm. Two days later the cardiac surgeon made banded the right PA. The child was extubated after the operation and discharged a week later. Conclusion: Hybrid approach opens new ways of correction or palliation in congenital heart disease with encouraging results and less morbidity.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this work we present numerical simulations of continuous flow left ventricle assist device implantation with the aim of comparing difference in flow rates and pressure patterns depending on the location of the anastomosis and the rotational speed of the device. Despite the fact that the descending aorta anastomosis approach is less invasive, since it does not require a sternotomy and a cardiopulmonary bypass, its benefits are still controversial. Moreover, the device rotational speed should be correctly chosen to avoid anomalous flow rates and pressure distribution in specific location of the cardiovascular tree. With the aim of assessing the differences between these two approaches and device rotational speed in terms of flow rate and pressure waveforms, we set up numerical simulations of network of one-dimensional models where we account for the presence of an outflow cannula anastomosed to different locations of the aorta. Then, we use the resulting network to compare the results of the two different cannulations for several stages of heart failure and different rotational speed of the device. The inflow boundary data for the heart and the cannulas are obtained from a lumped parameters model of the entire circulatory system with an assist device, which is validated with clinical data. The results show that ascending and descending aorta cannulations lead to similar waveforms and mean flow rate in all the considered cases. Moreover, regardless of the anastomosis region, the rotational speed of the device has an important impact on wave profiles; this effect is more pronounced at high RPM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Despite the improvements achieved in antibiotic therapy, severe aortic infection resulting in mycotic aneurysms is still a highly lethal disease and surgical management remains a challenging task. PATIENTS AND METHODS: A total of 43 patients with severe aortic infections were analyzed and separated in four groups: (1) Infections of the aortic root Ventriculo-aortic disconnection due to deep aortic infection (6 patients). Two patients were operated using homo-composit grafts. Of the 6 patients total, one died early and two died late during a mean follow-up of 6 years. The two patients with homografts are still alive. (2) Infections of the ascending aorta and the aortic arch. In situ repair for mycotic aneurysmal lesions of the ascending aorta was performed in 6 patients using synthetic graft material in 4/6, biological material in 1/6 and direct suture in 1/6. Two patients had to be reoperated; one of them died early. There was no recurrent infection during a mean follow-up of 6 years. (3) Infections of the descending thoracic and thoraco-abdominal aorta in-situ repair for mycotic aneurysmal lesions of the descending and thoraco-abdominal aorta was performed in 12 patients using homografts in five. Two patients died early and two other patients died late during a mean follow-up of 6 years. (4) Infections of the infrarenal abdominal aorta. In this series of 19 patients with mycotic infrarenal aortic aneurysms, in situ reconstruction was performed in 12 (5/12 with homografts) and extra-anatomic reconstruction (axillo-femoral bypass) was performed in 7. Hospital mortality was 5/19 patients and another 5/19 patients died during a mean follow-up of 6 years. One of the early deaths was due to aortic stump rupture. Two patients with axillo-femoral reconstructions were later converted to descending-thoracic-aortic-bifemoral bypasses. Five thromboses of axillo-femoral bypasses were observed in three of the seven patients with extra-anatomic repairs. RESULTS: Infections of the aortic root, the ascending aorta and the aortic arch are approached with total cardio-pulmonary bypass, using cardioplegic myocardial protection and deep hypothermia with circulatory arrest if necessary. Proximal unloading and distal support using partial cardiopulmonary bypass is preferred for repair of infected descending and thoracoabdominal aortic lesions, whereas no such adjuncts are required for repair of infected infrarenal aortic lesions. CONCLUSIONS: The anatomical location of the aortic infection and the availability of homologous graft material are the main factors determining the surgical strategy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this study was to determine whether thoracic endovascular aortic repair (TEVAR) reduces death and morbidity compared with open surgical repair for descending thoracic aortic disease. BACKGROUND: The role of TEVAR versus open surgery remains unclear. Metaregression can be used to maximally inform adoption of new technologies by utilizing evidence from existing trials. METHODS: Data from comparative studies of TEVAR versus open repair of the descending aorta were combined through meta-analysis. Metaregression was performed to account for baseline risk factor imbalances, study design, and thoracic pathology. Due to significant heterogeneity, registry data were analyzed separately from comparative studies. RESULTS: Forty-two nonrandomized studies involving 5,888 patients were included (38 comparative studies, 4 registries). Patient characteristics were balanced except for age, as TEVAR patients were usually older than open surgery patients (p = 0.001). Registry data suggested overall perioperative complications were reduced. In comparative studies, all-cause mortality at 30 days (odds ratio [OR]: 0.44, 95% confidence interval [CI]: 0.33 to 0.59) and paraplegia (OR: 0.42, 95% CI: 0.28 to 0.63) were reduced for TEVAR versus open surgery. In addition, cardiac complications, transfusions, reoperation for bleeding, renal dysfunction, pneumonia, and length of stay were reduced. There was no significant difference in stroke, myocardial infarction, aortic reintervention, and mortality beyond 1 year. Metaregression to adjust for age imbalance, study design, and pathology did not materially change the results. CONCLUSIONS: Current data from nonrandomized studies suggest that TEVAR may reduce early death, paraplegia, renal insufficiency, transfusions, reoperation for bleeding, cardiac complications, pneumonia, and length of stay compared with open surgery. Sustained benefits on survival have not been proven.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Revolutionary endovascular treatments are on the verge of being available for management of ascending aortic diseases. Morphometric measurements of the ascending aorta have already been done with ECG-gated MDCT to help such therapeutic development. However the reliability of these measurements remains unknown. The objective of this work was to compare the intraobserver and interobserver variability of CAD (computer aided diagnosis) versus manual measurements in the ascending aorta. Methods and materials: Twenty-six consecutive patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters at mid-distance between the brachiocephalic artery and the aortic valve were obtained automatically with a commercially available CAD and manually by two observers separately. Both observers repeated the measurements during a different session at least one month after the first measurements. Intraclass coefficients as well the Bland and Altman method were used for comparison between measurements. Two-paired t-test was used to determine the significance of intraobserver and interobserver differences (alpha = 0.05). Results: There is a significant difference between CAD and manual measurements in the maximum diameter (p = 0.004) for the first observer, whereas the difference was significant for minimum diameter between the second observer and the CAD (p <0.001). Interobserver variability showed a weak agreement when measurements were done manually. Intraobserver variability was lower with the CAD compared to the manual measurements (limits of variability: from -0.7 to 0.9 mm for the former and from -1.2 to 1.3 mm for the latter). Conclusion: In order to improve reproductibility of measurements whenever needed, pre- and post-therapeutic management of the ascending aorta may benefit from follow-up done by a unique observer with the help of CAD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the outcome of patients with ruptured descending thoracic and thoracoabdominal aortic aneurysms undergoing emergency repair, in comparison to elective surgery for chronic lesions. METHODS: A prospective study of 100 consecutive patients operated upon the descending aorta (1-8 segments) using proximal unloading and distal protection with partial cardiopulmonary bypass, heparin surface-coated perfusion equipment and low systemic heparinization (loading dose 100 IU/kg, activated coagulation time > 180 s), staged cross-clamping, sealed grafts and graft inclusion. RESULTS: Arteriosclerotic lesions were present in 53/100 patients (53%) for all, 30/53 (56%) for chronic, and 21/33 (63%) for ruptured, aneurysms (NS). Dissecting lesions were found in 38/100 patients (38%) for all, 20/53 (38%) for chronic, and 8/33 (24%) for ruptured aneurysms (NS). Preoperative hematocrit was 38 +/- 6% for all, 40 +/- 5% for chronic, and 33 +/- 5% for ruptured aneurysmal patients (P < 0.001 ruptured versus chronic). The extent of aortic repair (1-8 segments) was 3.3 +/- 1.6 for all, 3.5 +/- 1.5 for chronic, and 3.2 +/- 1.4 for ruptured, aneurysms (NS). Transdiaphragmatic repair was performed in 51/100 (51%) of all, 28/53 (53%) of chronic, and 17/33 (51%) of ruptured aneurysms (NS). Aortic cross-clamp time was 38 +/- 21 min for all, 39 +/- 24 min for chronic, and 38 +/- 17 min for ruptured, aneurysmal patients (NS). The amount of red cells washed and autotransfused was 2792 +/- 2239 ml in all, 3143 +/- 2531 ml in chronic, and 2074 +/- 1350 ml in ruptured, aneurysmal patients (P < 0.025). The amount of packed red cells required was 2181 +/- 1830 ml for all, 1736 +/- 1333 ml for chronic, and 2947 +/- 2395 ml for ruptured aneurysmal patients (P < 0.010). Thirty-day mortality was 9/100 (9%) for all, 3/53 (6%) for chronic, and 5/33 (15%) for ruptured aneurysmal patients (NS). Parapareses/plegias occurred in 9/100 (9%) of all, 6/53 (11%) of chronic, and 3/33 (9%) of ruptured, aneurysmal patients (NS). Stepwise regression analysis identified aortic cross-clamp time as a predictor of early mortality (P = 0.002) and parapareses and paraplegias (P = 0.001). Age (P = 0.001), extent of repair (P = 0.008) and preoperative hematocrit (P = 0.001) were predictors for homologous transfusion requirements. CONCLUSION: Emergency repair of ruptured descending thoracic and thoracoabdominal aortic aneurysms can be achieved with acceptable results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Upon agonist stimulation, endothelial cells trigger smooth muscle relaxation through the release of relaxing factors such as nitric oxide (NO). Endothelial cells of mouse aorta are interconnected by gap junctions made of connexin40 (Cx40) and connexin37 (Cx37), allowing the exchange of signaling molecules to coordinate their activity. Wild-type (Cx40(+/+)) and hypertensive Cx40-deficient mice (Cx40(-/-)), which also exhibit a marked decrease of Cx37 in the endothelium, were used to investigate the link between the expression of endothelial connexins (Cx40 and Cx37) and endothelial nitric oxide synthase (eNOS) expression and function in the mouse aorta. With the use of isometric tension measurements in aortic rings precontracted with U-46619, a stable thromboxane A(2) mimetic, we first demonstrate that ACh- and ATP-induced endothelium-dependent relaxations solely depend on NO release in both Cx40(+/+) and Cx40(-/-) mice, but are markedly weaker in Cx40(-/-) mice. Consistently, both basal and ACh- or ATP-induced NO production were decreased in the aorta of Cx40(-/-) mice. Altered relaxations and NO release from aorta of Cx40(-/-) mice were associated with lower expression levels of eNOS in the aortic endothelium of Cx40(-/-) mice. Using immunoprecipitation and in situ ligation assay, we further demonstrate that eNOS, Cx40, and Cx37 tightly interact with each other at intercellular junctions in the aortic endothelium of Cx40(+/+) mice, suggesting that the absence of Cx40 in association with altered Cx37 levels in endothelial cells from Cx40(-/-) mice participate to the decreased levels of eNOS. Altogether, our data suggest that the endothelial connexins may participate in the control of eNOS expression levels and function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The RCP is a 14 French collapsable percutaneous cardiovascular support device positioned in the descending part of the thoracic aorta via the femoral artery. A 10 patient first in man study demonstrated device safety and significant improvement in renal function among high risk PCI patients. We now report haemodynamic and renal efficacy in patients with ADHF.Methods: Prospective non randomised study seeking to recruit 20 patients with ADHF with a need for inotropic or mechanical circulatory support with: i) EF < 30% ii)Cardiac index(CI) < 2.2 L / min / m2 Outcome measures included: 1) Cardiac index (CI) 2) Pulmonary Capillary Wedge Pressure (PCWP) 3) Urine output / serum creatinine 4) Vascular / device complications 5) 30 day mortalityResults: INTERIM ANALYSIS (n=12) The mean age of the study group was 64 years, with a mean baseline creatinine of 193 umol/L, eGFR 38 ml/min. The intended RCP treatment period was 24 hours. During RCP treatment there was a significant mean reduction of PCWP at 4 hours of 17% (25 to 21 mmHg p=0.04). Mean CI increased at 12 hours by 11%, though not reaching significance (1.78 to 1.96 L/min/m2 p=0.08). RCP insertion prompted substantial diuresis. Urine output tripled over the first 12 hours compared to baseline (55 ml/hr vs 213 ml/hr p=0.03). This was associated with significantly improved renal function, a 28% reduction in serum creatinine at 12 hours (193 to 151 umol/L p=0.003), and a increase in eGFR from 38 ml/min to 50 ml/min (p=0.0007). 2 patients previously refused cardiac transplantation were reassessed and successfully transplanted within 9 months of RCP treatment on the basis of demonstrable renal reversibility. There were no vascular or device complications. There were 2 deaths at 30 days, one from multi-organ failure and sepsis, and one from intractable heart failure - neither were device related.Conclusion: RCP support in ADHF patients was associated with improved haemodynamics, and an improvement in renal function. The Reitan Catheter Pump may have a role in providing percutaneous cardiovascular and renal support in the acutely decompensated cardiac patient, and may have a role in suggesting renal reversibility in potential cardiac transplant patients. Further data will be reported at recruitment completion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Recently morphometric measurements of the ascending aorta have been done with ECG-gated MDCT to help the development of future endovascular therapies (TCT) [1]. However, the variability of these measurements remains unknown. It will be interesting to know the impact of CAD (computer aided diagnosis) with automated segmentation of the vessel and automatic measurements of diameter on the management of ascending aorta aneurysms. Methods and Materials: Thirty patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters were obtained automatically with a commercially available CAD and semi-manually by two observers separately. The CAD algorithms segment the iv-enhanced lumen of the ascending aorta into perpendicular planes along the centreline. The CAD then determines the largest and the smallest diameters. Both observers repeated the automatic measurements and the semimanual measurements during a different session at least one month after the first measurements. The Bland and Altman method was used to study the inter/intraobserver variability. A Wilcoxon signed-rank test was also used to analyse differences between observers. Results: Interobserver variability for semi-manual measurements between the first and second observers was between 1.2 to 1.0 mm for maximal and minimal diameter, respectively. Intraobserver variability of each observer ranged from 0.8 to 1.2 mm, the lowest variability being produced by the more experienced observer. CAD variability could be as low as 0.3 mm, showing that it can perform better than human observers. However, when used in nonoptimal conditions (streak artefacts from contrast in the superior vena cava or weak lumen enhancement), CAD has a variability that can be as high as 0.9 mm, reaching variability of semi-manual measurements. Furthermore, there were significant differences between both observers for maximal and minimal diameter measurements (p<0.001). There was also a significant difference between the first observer and CAD for maximal diameter measurements with the former underestimating the diameter compared to the latter (p<0.001). As for minimal diameters, they were higher when measured by the second observer than when measured by CAD (p<0.001). Neither the difference of mean minimal diameter between the first observer and CAD nor the difference of mean maximal diameter between the second observer and CAD was significant (p=0.20 and 0.06, respectively). Conclusion: CAD algorithms can lessen the variability of diameter measurements in the follow-up of ascending aorta aneurysms. Nevertheless, in non-optimal conditions, it may be necessary to correct manually the measurements. Improvements of the algorithms will help to avoid such a situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèse : Mesures de l'aorte ascendante par scanner synchronisé au rythme cardiaque: une étude pilote pour établir des valeurs normatives dans le cadre des futures thérapies par transcathéter. Objectif : L'objectif de cette étude est d'établir les valeurs morphométriques normatives de l'aorte ascendante à l'aide de l'angiographie par scanner synchronisé au rythme cardiaque, afin d'aider au développement des futurs traitements par transcathéter. Matériels et méthodes : Chez soixante-dix-sept patients (âgé de 22 à 83 ans, âge moyen: 54,7 ans), une angiographie par scanner synchronisé au rythme cardiaque a été réalisée pour évaluation des vaisseaux coronaires. Les examens ont été revus afin d'étudier l'anatomie de la chambre de chasse du ventricule gauche jusqu'au tronc brachio-céphalique droit. A l'aide de programmes de reconstructions multiplanaires et de segmentation automatique, différents diamètres et longueurs considérés comme importants pour les futurs traitements par transcathéter ont été mesurés. Les valeurs sont exprimées en moyennes, médianes, maximums, minimums, écart-types et en coefficients de variation. Les variations de diamètre de l'aorte ascendante durant le cycle cardiaque ont été aussi considérées. Résultats : Le diamètre moyen de la chambre de chasse du ventricule gauche était de 20.3+/-3.4 mm. Au niveau du sinus coronaire de l'aorte, il était de 34.2+/-4.1 mm et au niveau de la jonction sinotubulaire il était de 29.7+/-3.4 mm. Le diamètre moyen de l'aorte ascendante était de 32.7+/-3.8 mm. Le coefficient de variation de ces mesures variait de 12 à 17%. La distance moyenne entre l'insertion proximale des valvules aortiques et le départ du tronc brachio-céphalique droit était de 92.6+/-11.8 mm. La distance moyenne entre l'insertion proximale des valvules aortiques et l'origine de l'artère coronaire proximale était de 12.1+/-3.7 mm avec un coefficient de variation de 31%. La distance moyenne entre les deux ostia coronaires était de 7.2+/-3.1 mm avec un coefficient de variation de 43%. La longueur moyenne du petit arc de l'aorte ascendante entre l'artère coronaire gauche et le tronc brachio-céphalique droit était de 52.9+/-9.5 mm. La longueur moyenne de la continuité fibreuse entre la valve aortique et la valvule mitrale antérieure était de 14.6+/-3.3 mm avec un coefficient de variation de 23%. L'aire moyenne de la valve aortique était de 582.0+/-131.9 mm2. La variation du diamètre antéro-postérieur et transverse de l'aorte ascendante était respectivement de 8.4% et de 7.3%. Conclusion Il existe d'importantes variations inter-individuelles dans les mesures de l'aorte ascendante avec cependant des variations intra-individuelles faibles durant le cycle cardiaque. De ce fait, une approche personnalisée pour chaque patient est recommandée dans la confection des futures endoprothèses de l'aorte ascendante. Le scanner synchronisé au rythme cardiaque jouera un rôle prépondérant dans le bilan préthérapeutique. Abstract : The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3+/-3.4, coronary sinus 34.2+/-4.1, sinotubular junction 29.7+-3.4 and mid ascending aorta 32.7+/-3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6111.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1+/-3.7, and between both coronary ostia 7.2+/-3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 X9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.óf3.3, CV 13-43%. Mean aortic valve area was 582+-131.9 mm2. The variations of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectif: Déterminer la prévalence de la dysfonction de la valve aortique, de la dilatation de l'aorte proximale et des interventions au niveau de la valve aortique et de l'aorte ascendante chez les adultes avec une coarctation de l'aorte. Contexte: La dysfonction de la valve aortique et la dilatation de l'aorte proximale sont rares chez les enfants et les adolescents avec une coarctation de l'aorte. A long terme, les adultes pourraient être plus à risque de développer ce type de pathologie. Méthode: Nous avons rétrospectivement passé en revue tous les adultes avec une coarctation de l'aorte corrigée ou pas suivis au « Boston Children's Hospital » entre 2004 et 2010. Résultats: 216 adultes (56 % d'hommes) avec une coarctation ont été identifiés. L'âge médian à la dernière évaluation était de 28 (de 18 à 75) ans. Une bicuspidie aortique était présente dans 66% des cas. Au dernier contrôle, 3% avaient une sténose aortique modérée ou sévère et 4% avaient une insuffisance aortique modérée à sévère. Une dilatation de la racine de l'aorte ou de l'aorte ascendante était présente dans 28%, respectivement 42% des patients. Une dilatation au moins modérée de la racine de l'aorte ou de l'aorte ascendante (score Z > 4) était présente dans 8%, respectivement 14%. Les patients avec une bicuspidie aortique étaient plus sujets à avoir une dilatation au moins modérée de la racine de l'aorte ou de l'aorte ascendante comparés à ceux sans bicuspidie (20% contre 0%; p<0.001). L'âge était associé à une dilatation de l'aorte ascendante (p=0.04). Au dernier suivi, 6% avait nécessité une intervention au niveau de la valve aortique et 3% un remplacement de la racine de l'aorte ou de l'aorte ascendante.