127 resultados para Defect repair

em Université de Lausanne, Switzerland


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: Cardiac Troponin-I (cTnI) is a well-recognized early postoperative marker for myocardial damage in adults and children after heart surgery. The present study was undertaken to evaluate whether the integrated value (area under the curve(AUC)) of postoperative cTnI is a better mode to predict long-term outcome than post operative cTnI maximum value, after surgery for congenital heart defects (CHD). Methods: retrospective cohort study. 279 patients (mean age 4.6 years; range 0-17 years-old, 185 males) with congenital heart defect repair on cardiopulmonary by-pass were retrieved from our database including postoperative cTnI values. Maximal post operative cTnI value, post operative cTnI AUC value at 48h and total post operative cTnI AUC value were calculated and then correlated with duration of intubation, duration of ICU stay and mortality. Results: the mean duration of mechanical ventilation was 5.1+/-7.2 days and mean duration of ICU stay was 11.0+/- 13.3 days,11 patients (3.9%) died in post operative period. When comparing survivor and deceased groups, there was a significant difference in the mean value for max cTnI (16.7+/- 21.8 vs 59.2+/-41.4 mcg/l, p+0.0001), 48h AUC cTnI (82.0+/-110.7 vs 268.8+/-497.7 mcg/l, p+0.0001) and total AUC cTnI (623.8+/-1216.7 vs 2564+/-2826.0, p+0.0001). Analyses for duration of mechanical ventilation and duration of ICU stay by linear regression demonstrated a better correlation for 48h AUC cTnI (ventilation time r+0.82, p+0.0001 and ICU stay r+0.74, p+0.0001) then total AUC cTnI (ventilation time r+0.65, p+0.0001 and ICU stay r+0.60, p+0.0001) and max cTnI (ventilation time r+0.64, p+0.0001 and ICU stay r+0.60, p+0.0001). Conclusion: Cardiac Troponin I is a specific and sensitive marker of myocardial injury after congenital heart surgery and it may predict early in-hospital outcomes. Integration of post operative value of cTnI by calculation of AUC improves prediction of early in-hospital outcomes. It probably takes into account, not only the initial surgical procedure, but probably also incorporates the occurrence of hypoxic-ischemic phenomena in the post-operative period.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We describe a novel repair of an anterior inflammatory tracheal defect with mediastinitis, which occurred after external tracheal suspension of localized intrathoracic tracheomalacia. The malacic tracheal segment of 4-cm length containing the inflammatory tracheal defect was noncircumferentially resected. A temporary endotracheal silicone stent was introduced, and the trachea was closed by a pedicled pectoralis muscle flap reinforced with an embedded rib segment. Retrieval of the stent 5 months postoperatively resulted in a re-epithelialized, persistently stable, noncollapsible tracheal segment that showed the same diameter and configuration as the nonreconstructed part of the trachea.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Surgical correction of complete atrio-ventricular septal defect (AVSD) achieves satisfactory results with low morbidity and mortality, but may require reoperation. Our recent operative results at mid-term were followed-up. METHODS: From June 2000 to December 2007, 81 patients (Down syndrome; n=60), median age 4.0 months (range 0.7-118.6) and weight 4.7kg (range 2.2-33), underwent complete AVSD correction. Patch closure for the ventricular septal defect (VSD; n=69) and atrial septal defect (ASD; n=42) was performed with left atrio-ventricular valve (LAVV) cleft closure (n=76) and right atrio-ventricular valve (RAVV) repair (n=57). Mortality, morbidity, and indications for reoperation were retrospectively studied; the end point 'time to reoperation' was analyzed using Kaplan-Meier curves. Follow-up was complete except in two patients and spanned a median of 28 months (range 0.4-6.1 years). RESULTS: In-hospital mortality was 3.7% (n=3) and one late death occurred. Reoperation was required in 7/79 patients (8.9%) for LAVV insufficiency (n=4), for a residual ASD (n=1), for right atrio-ventricular valve insufficiency (n=1), and for subaortic stenosis (n=1). At last follow-up, no or only mild LAVV and RAVV insufficiency was present in 81.3% and 92.1% of patients, respectively, and 2/3 of patients were medication-free. Risk factors for reoperation were younger age (<3 months; p=0.001) and lower weight (<4kg; p=0.003), and a trend towards less and later reoperations in Down syndrome (p<0.2). CONCLUSIONS: Surgical correction of AVSD can be achieved with low mortality and need for reoperation, regardless of Down syndrome or not. Immediate postoperative moderate or more residual atrio-ventricular valve insufficiency will eventually require a reoperation, and could be anticipated in patients younger than 3 months and weighing <4kg.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Large intrathoracic airway defects may be closed using a pedicled latissimus dorsi (LD) flap, with rewarding results. This study addresses the question of whether this holds true for extrathoracic non-circumferential tracheal defects. METHODS: A cervical segment of the trachea of 4 x 1 cm was resected in 9 white male pigs. The defect was stented with a silicone stent for 3 months and closed either by an LD flap alone (group a, n = 3), an LD flap with an attached rib segment covered by pleura (group b, n = 3), or an LD flap reinforced by a perforated polylactide (MacroPore) plate (group c, n = 3). The trachea was assessed by rigid endoscopy at 3 and 4 months and histologically at 4 months postoperatively. RESULTS: The degree of stenosis at the level of the reconstruction at 4 months was 25, 50 and 75% in group a, 15, 50 and 60% in group b, and 20, 95 and 95% in group c, respectively. The percentage of the defect covered by columnar epithelium was 100% in all animals of group a, 60, 100 and 100% in group b, and 10, 0 and 0% in group c. Resorption of the rib was seen in all animals of group b and obstructive inflammatory polyps were found in 2 animals of group c. CONCLUSION: Pedicled LD flaps provided less satisfactory results for closure of large non-circumferential extrathoracic airway defects than observed after intrathoracic reconstruction. A pedicled rib segment added to the LD flap did not improve the results obtained from LD flap repair alone, and an embedded MacroPore prosthesis may result in severe airway stenosis due to plate migration and intense inflammatory reaction protruding into the tracheal lumen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Five days after surgical repair of pectus excavatum, this 7-year-old boy had a right-sided Kirschner wire protruding beneath the skin. The wire was repositioned blindly. Severe congestive heart failure developed. Surgical exploration showed a pierced right atrium, a torn septal leaflet of the tricuspid valve and noncoronary aortic cusp, and a large traumatic ventricular septal defect. The outcome and the indications and possible complications of surgery are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AbstractBackground: Mucosal healing is becoming a major goal in the treatment of Crohn's disease. It has been previously reported that myeloid cells induce mucosal healing in a mouse model of acute colitis. The aim in this study is to investigate the pro-repair function of myeloid cells in healthy donors (HD) and Crohn's disease patients (CD).Methods: Peripheral blood mononuclear cells (PBMC) from HD and CD patients were isolated from blood samples and tested either directly or after differentiation ex-vivo into macrophages (Μφ). Intestinal macrophages (IMACs) were isolated from the bowel mucosa of patients undergoing intestinal surgical resections. Through an in vitro wound healing assay the repairing ability of these various human myeloid cells and the mechanisms responsible of wound healing were evaluated.Results: PBMC and myeloid CD14+ cells from HD and CD were not able to repair at any tested cell concentration. Μφ from HD and ulcerative colitis (UC) patients were able to induce wound healing and this capacity was partially mediated by Hepatocyte Growth Factor (HGF). Remarkably, CD Μφ were unable to promote wound healing and produced lower levels of HGF as compared to Μφ from HD or UC patients. In particular, Μφ from CD in active phase (ACD) exhibited the weakest repair function, but this defect was rescued if rh- GM-CSF was added during the differentiation of PBMCs. Interestingly, IMACs from HD promoted wound healing and produced HGF.Conclusion: We demonstrated that CD Μφ, unlike HD or UC Μφ, were defective in promoting wound healing, in particular if coming from an ACD. This deficient pro-repair function was related to a lower production of HGF. IMACs from HD colonic mucosa induced wound healing, confirming the results obtained with Μφ. Our results are in keeping with the current theory of CD as an innate immunodeficiency. In this context, Μφ may be responsible for the mucosal repair defects observed in CD patients and for the subsequent chronic activation of the adaptive immune response.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Previous studies support resorbable biocomposites made of poly(L-lactic acid) (PLA) and beta-tricalcium phosphate (TCP) produced by supercritical gas foaming as a suitable scaffold for tissue engineering. The present study was undertaken to demonstrate the biocompatibility and osteoconductive properties of such a scaffold in a large animal cancellous bone model. The biocomposite (PLA/TCP) was compared with a currently used beta-TCP bone substitute (ChronOS, Dr. Robert Mathys Foundation), representing a positive control, and empty defects, representing a negative control. Ten defects were created in sheep cancellous bone, three in the distal femur and two in the proximal tibia of each hind limb, with diameters of 5 mm and depths of 15 mm. New bone in-growth (osteoconductivity) and biocompatibility were evaluated using microcomputed tomography and histology at 2, 4 and 12 months after surgery. The in vivo study was validated by the positive control (good bone formation with ChronOS) and the negative control (no healing with the empty defect). A major finding of this study was incorporation of the biocomposite in bone after 12 months. Bone in-growth was observed in the biocomposite scaffold, including its central part. Despite initial fibrous tissue formation observed at 2 and 4 months, but not at 12 months, this initial fibrous tissue does not preclude long-term application of the biocomposite, as demonstrated by its osteointegration after 12 months, as well as the absence of chronic or long-term inflammation at this time point.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Patients with Ebstein's anomaly can present after childhood or adolescence with cyanosis, arrhythmias, severe right ventricular dysfunction and frequently with left ventricular dysfunction secondary to the prolonged cyanosis and to the right ventricular interference. At this point conventional repair is accompanied by elevated mortality and morbidity and poor functional results. We report our experience with three patients (8, 16 and 35 years of age) with Ebstein's anomaly, very dilated right atrium, severe tricuspid valve regurgitation (4/4), bi-directional shunt through an atrial septal defect and reduced left ventricular function (mean ejection fraction = 58%, mean shortening fraction = 25%). All underwent one and a half ventricular repair consisting of closure of the atrial septal defect, tricuspid repair with reduction of the atrialised portion of the right ventricle and end-to-side anastomosis of the superior vena cava to the right pulmonary artery. All patients survived, with a mean follow-up of 33 months. In all there was complete regression of the cyanosis and of the signs of heart failure. Postoperative echocardiography showed reduced degree of tricuspid regurgitation (2/4) and improvement of the left ventricular function (mean ejection fraction = 77%, mean shortening fraction = 40%). In patients with Ebstein's anomaly referred late for surgery with severely compromised right ventricular function or even with reduced biventricular function, the presence of a relatively hypoplastic and/or malfunctioning right ventricular chamber inadequate to sustain the entire systemic venous return but capable of managing part of the systemic venous return, permits a one and a half ventricular repair with good functional results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tracheobronchial aspergillosis is a rare entity mainly observed in immune-compromised patients or those who have undergone transplantation. It may cause airway ulcerations or bleeding. We report the case of a 17-year-old patient receiving chemotherapy for acute lymphoblastic leukemia who presented with right-sided tension pneumothorax. Chest tube drainage revealed a massive air leak without reexpansion of the lung, and bronchoscopy showed a 15- × 15-mm defect of the distal trachea related to aspergillosis infection. The defect was closed by an intrathoracic transposition of a pedicled latissimus dorsi muscle flap, which was sutured into the debrided defect followed by temporary endotracheal stenting and antifungal medication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Several scores are commonly used to evaluate patients' postoperative satisfaction after lateral ankle ligament repair, including: AOFAS, FAAM, CAIT and CAIS. Comparing published studies in the literature is difficult, as the same patient can have markedly different results depending on which scoring system is used. The current study aims to address this gap in the literature by developing a system to compare these tests, to allow better analysis and comparison of published studies. Patients and methods: This is a retrospective cohort study of 47 patients following lateral ankle ligament repair using a modified Broström-Gould technique. All patients were operated between 2005 and 2010 by a single surgeon and followed the same post operative rehabilitation protocol. Six patients were excluded from the study because of concomitant surgery. Patients were assessed by an independent observer. We used the Pearson correlation coefficient to analyse the concordance of the scores, as well as scatter plots to assess the linear relationship between them. Results: A linear distribution between the scores was found when the results were analysed using scatter plots. We were thus able to use the Pearson correlation coefficient to evaluate the relationship between each of the different postoperative scores. The correlation was found to be above 0.5 in all cases except for the comparison between the CAIT and the FAAM for the activities of daily living (0.39). We were, therefore, able to compare the results obtained and assess the relative concordance of the scoring systems. The results showed that the more specific the scale is, the worst the score is and inversely. So the CAIT and the CAIS appeared to be more severe than the AOFAS and the FAAM measuring the activities of daily living. The sports subscale of the FAAM demonstrated intermediate results. Conclusion: This study outlines a system to compare different postoperative scores commonly used to evaluate outcome after ankle stabilization surgery. The impact of this study is that it makes comparison of published studies easier, even though they use a variety of different clinical scores, thus facilitating better outcome analysis of operative techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human MRE11 is a key enzyme in DNA double-strand break repair and genome stability. Human MRE11 bears a glycine-arginine-rich (GAR) motif that is conserved among multicellular eukaryotic species. We investigated how this motif influences MRE11 function. Human MRE11 alone or a complex of MRE11, RAD50, and NBS1 (MRN) was methylated in insect cells, suggesting that this modification is conserved during evolution. We demonstrate that PRMT1 interacts with MRE11 but not with the MRN complex, suggesting that MRE11 arginine methylation occurs prior to the binding of NBS1 and RAD50. Moreover, the first six methylated arginines are essential for the regulation of MRE11 DNA binding and nuclease activity. The inhibition of arginine methylation leads to a reduction in MRE11 and RAD51 focus formation on a unique double-strand break in vivo. Furthermore, the MRE11-methylated GAR domain is sufficient for its targeting to DNA damage foci and colocalization with gamma-H2AX. These studies highlight an important role for the GAR domain in regulating MRE11 function at the biochemical and cellular levels during DNA double-strand break repair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peripheral nerve injury is a serious problem affecting significantly patients' life. Autografts are the "gold standard" used to repair the injury gap, however, only 50% of patients fully recover from the trauma. Artificial conduits are a valid alternative to repairing peripheral nerve. They aim at confining the nerve environment throughout the regeneration process, and providing guidance to axon outgrowth. Biocompatible materials have been carefully designed to reduce inflammation and scar tissue formation, but modifications of the inner lumen are still required in order to optimise the scaffolds. Biomicking the native neural tissue with extracellular matrix fillers or coatings showed great promises in repairing longer gaps and extending cell survival. In addition, extracellular matrix molecules provide a platform to further bind growth factors that can be released in the system over time. Alternatively, conduit fillers can be used for cell transplantation at the injury site, reducing the lag time required for endogenous Schwann cells to proliferate and take part in the regeneration process. This review provides an overview on the importance of extracellular matrix molecules in peripheral nerve repair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine whether the relative afferent pupillary defect (RAPD) remains constant over time in normal subjects. METHODS: Seventeen normal subjects were tested with infrared pupillography and automated perimetry in four sessions over 3 years. The changes in RAPD and visual field asymmetry between testing sessions were compared. RESULTS: The range of RAPD was 0.0 to 0.3 log unit, and the difference in the mean deviation between the eyes on automated static perimetry was 0 to 3 dB. Eight subjects repeatedly had an RAPD in the same eye. There was no correlation between the RAPD and the visual field asymmetry at the same visit. Changes in the magnitude of the RAPD between any two sessions were typically small (median, 0.08 log unit; 25th percentile, 0.04 log unit; 75th percentile, 0.15 log unit). CONCLUSIONS: Some normal subjects may show a persistent but small RAPD in the absence of detectable pathologic disease. Therefore, an isolated RAPD in the range of 0.3 log unit that is not associated with any other significant historical or clinical finding should probably be considered benign.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Advances in wound care are of great importance in clinical injury management. In this respect, the nuclear receptor peroxisome proliferator-activated receptor (PPAR)beta/delta occupies a unique position at the intersection of diverse inflammatory or anti-inflammatory signals that influence wound repair. This study shows how changes in PPARbeta/delta expression have a profound effect on wound healing. Using two different in vivo models based on topical application of recombinant transforming growth factor (TGF)-beta1 and ablation of the Smad3 gene, we show that prolonged expression and activity of PPARbeta/delta accelerate wound closure. The results reveal a dual role of TGF-beta1 as a chemoattractant of inflammatory cells and repressor of inflammation-induced PPARbeta/delta expression. Also, they provide insight into the so far reported paradoxical effects of the application of exogenous TGF-beta1 at wound sites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: : Intravascular ultrasound (IVUS) generates high definition circumferential cross-sectional images and provides real-time readout of vascular dimensions, including visualization of vessel branches. We have used it as an alternative to angiography in the endovascular thoracic aneurysm repair work-up. METHODS: : Out of consecutive 203 patients with descending thoracic aortic aneurysm, 89 (43.8%) received endovascular treatment [mean age, 68 ± 8 years; range, 29-82; male, 79 (88.7%); female, 10 (11.3%)] without using angiography during the endovascular procedure. IVUS (6 F, 12.5 MHz probe or 10 F 9 MHz) coupled with fluoroscopy for the placement of radiopaque markers was used for target site identification, landing zone measurement, device positioning, and assessment of endovascular repair. RESULTS: : Hospital mortality was 4/89 (4.5%). Number of devices implanted in each patient was 1.2 (range, 1-3). X-ray exposure time was 12 ± 8 minutes. Median procedure time was 63 ± 20 minutes. Conversion to open surgery was necessary in one patient (1.1%) because of aortic dissection. In nine patients (10.1%) left subclavian artery was covered because of a short neck. Two patients (2.2%) had vascular access lesions and required surgical repair. One patient developed paraplegia (1.1%). Early endoleak was observed in eight patients (8.9%) and 4 (4.5%) required additional procedures (proximal or distal extensions). Late conversion was necessary in one patient (1.1%). CONCLUSIONS: : IVUS provides all information necessary for device selection, target site identification as well as safe and correct deployment of thoracic endoprostheses and makes periprocedural angiography unnecessary, thus avoiding the risk of renal failure because of contrast medium.