29 resultados para Daisy Dominguez

em Université de Lausanne, Switzerland


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this work was to develop an easily applicable technique and a standardized protocol for high-quality post-mortem angiography. This protocol should (1) increase the radiological interpretation by decreasing artifacts due to the perfusion and by reaching a complete filling of the vascular system and (2) ease and standardize the execution of the examination. To this aim, 45 human corpses were investigated by post-mortem computed tomography (CT) angiography using different perfusion protocols, a modified heart-lung machine and a new contrast agent mixture, specifically developed for post-mortem investigations. The quality of the CT angiographies was evaluated radiologically by observing the filling of the vascular system and assessing the interpretability of the resulting images and by comparing radiological diagnoses to conventional autopsy conclusions. Post-mortem angiography yielded satisfactory results provided that the volumes of the injected contrast agent mixture were high enough to completely fill the vascular system. In order to avoid artifacts due to the post-mortem perfusion, a minimum of three angiographic phases and one native scan had to be performed. These findings were taken into account to develop a protocol for quality post-mortem CT angiography that minimizes the risk of radiological misinterpretation. The proposed protocol is easy applicable in a standardized way and yields high-quality radiologically interpretable visualization of the vascular system in post-mortem investigations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel approach to measure carbon dioxide (CO2) in gaseous samples, based on a precise and accurate quantification by (13)CO2 internal standard generated in situ is presented. The main goal of this study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable in the routine determination of CO2. The main drawback of the GC methods discussed in the literature for CO2 measurement is the lack of a specific internal standard necessary to perform quantification. CO2 measurement is still quantified by external calibration without taking into account analytical problems which can often occur considering gaseous samples. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in situ an internal labeled standard gas ((13)CO2) on the basis of the stoichiometric formation of CO2 by the reaction of hydrochloric acid (HCl) with sodium hydrogen carbonate (NaH(13)CO3). This method allows a precise measurement of CO2 concentration and was validated on various human postmortem gas samples in order to study its efficiency.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Distinguishing postmortem gas accumulations in the body due to natural decomposition and other phenomena such as gas embolism can prove a difficult task using purely Multi-Detector Computed Tomography (MDCT). The Radiological Alteration Index (RAI) was created with the intention to be able to identify bodies undergoing the putrefaction process based on the quantity of gas detected within the body. The flaw in this approach is the inability to absolutely determine putrefaction as the origin of gas volumes in cases of moderate alteration. The aim of the current study is to identify percentage compositions of O2, N2, CO2 and the presence of gases such as H2 and H2S within these sampling sites in order to resolve this complication. Materials and methods: All cases investigated in our University Center of Legal Medicine are undergoing a Post-Mortem Computed Tomography (PMCT)-scan before external examination or autopsy as a routine investigation. In the obtained images, areas of gas were characterized as 0, I, II or III based on the amount of gas present according to the RAI (1). The criteria for these characterizations were dependent of the site of gas, for example thoracic and abdominal cavities were graded as I (1 - 3cm gas), II (3 - 5cm gas) and III (>5cm gas). Cases showing gaseous sites with grade II or III were selected for this study. The sampling was performed under CT-guidance to target the regions to be punctured. Luer-lock PTFE syringes equipped with a three-way valve and needles were used to sample the gas directly (2). Gaseous samples were then analysed using gas chromatography coupled to a thermal conductivity detector (GC-TCD). The components present in the samples were expressed as a percentage of the overall gas present. Results: Up to now, we have investigated more than 40 cases using our standardized procedure for sampling and analysis of gas. O2, N2 and CO2 were present in most samples. The following distributions were found to correlate to gas origins of gas embolism/scuba diving accidents, trauma and putrefaction: ? Putrefaction → O2 = 1 - 5%; CO2 > 15%; N2 = 10 - 70%; H2 / H2S / CH4 variable presence ? Gas embolism/Scuba diving accidents → O2 and N2= varying percentages; CO2 > 20% ? Trauma → O2 = small percentage; CO2 < 15%; N2 > 65% H2 and H2S indicated levels of putrefaction along with methane which can also gauge environmental conditions or conditions of body storage/burial. Many cases showing large RAI values (advanced alteration) did reveal a radiological diagnosis which was in concordance with the interpretation of the gas composition. However, in certain cases (gas embolism, scuba divers) radiological interpretation was not possible and only chemical gas analysis was found to lead to the correct diagnosis, meaning that it provided complementary information to the radiological diagnosis. Conclusion: Investigation of postmortem gases is a useful tool to determine origin of gas generation which can aid the diagnosis of the cause of death. Levels of gas can provide information on stage of putrefaction and help to perform essential medico-legal diagnosis such as vital gas embolism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Atrophic age-related macular degeneration (AMD) is associated with the subretinal accumulation of mononuclear phagocytes (MPs). Their role in promoting or inhibiting retinal degeneration is unknown. We here show that atrophic AMD is associated with increased intraocular CCL2 levels and subretinal CCR2(+) inflammatory monocyte infiltration in patients. Using age- and light-induced subretinal inflammation and photoreceptor degeneration in Cx3cr1 knockout mice, we show that subretinal Cx3cr1 deficient MPs overexpress CCL2 and that both the genetic deletion of CCL2 or CCR2 and the pharmacological inhibition of CCR2 prevent inflammatory monocyte recruitment, MP accumulation and photoreceptor degeneration in vivo. Our study shows that contrary to CCR2 and CCL2, CX3CR1 is constitutively expressed in the retina where it represses the expression of CCL2 and the recruitment of neurotoxic inflammatory CCR2(+) monocytes. CCL2/CCR2 inhibition might represent a powerful tool for controlling inflammation and neurodegeneration in AMD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Postmortem computed tomography angiography (PMCTA) was introduced into forensic investigations a few years ago. It provides reliable images that can be consulted at any time. Conventional autopsy remains the reference standard for defining the cause of death, but provides only limited possibility of a second examination. This study compares these two procedures and discusses findings that can be detected exclusively using each method. MATERIALS AND METHODS: This retrospective study compared radiological reports from PMCTA to reports from conventional autopsy for 50 forensic autopsy cases. Reported findings from autopsy and PMCTA were extracted and compared to each other. PMCTA was performed using a modified heart-lung machine and the oily contrast agent Angiofil® (Fumedica AG, Muri, Switzerland). RESULTS: PMCTA and conventional autopsy would have drawn similar conclusions regarding causes of death. Nearly 60 % of all findings were visualized with both techniques. PMCTA demonstrates a higher sensitivity for identifying skeletal and vascular lesions. However, vascular occlusions due to postmortem blood clots could be falsely assumed to be vascular lesions. In contrast, conventional autopsy does not detect all bone fractures or the exact source of bleeding. Conventional autopsy provides important information about organ morphology and remains the only way to diagnose a vital vascular occlusion with certitude. CONCLUSION: Overall, PMCTA and conventional autopsy provide comparable findings. However, each technique presents advantages and disadvantages for detecting specific findings. To correctly interpret findings and clearly define the indications for PMCTA, these differences must be understood.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In einigen rechtsmedizinischen Instituten gehört die postmortale Bildgebung, mittels MDCT (multidetector computed tomography) bereits zur täglichen Routine. Die Kombination dieser radiologischen Untersuchung und der anschließenden konventionellen Autopsie zeigt deutliche Vorteile im forensischen Alltag. Die Durchführung einer postmortalen Angiographie kann die Aussagekraft der Untersuchungen noch weiter verbessern. Im Institut für Rechtsmedizin in Lausanne-Genf, wurde die Technik der postmortalen dynamischen Angiographie entwickelt, bei der die Gefäße mittels des Kontrastmittels Angiofil® sichtbar gemacht werden. Es handelt sich dabei um eine minimal-invasive Technik einer Ganzkörperangiographie. Mittels einer modifizierten Kreislaufmaschine wird das Gefäßsystem perfundiert und gleichzeitig werden MDCT-Scans gemacht. Dies ermöglicht die Abbildung der Gefäße in verschiedenen Perfusionsstadien (arteriell und venös) während einer Zirkulation, ähnlich der Angiographie eines lebenden Patienten. Eine vollständige und länger andauernde Perfusion ist dank des öligen Kontrastmittels Angiofil® möglich. Es bleibt intravaskulär, ohne wesentlichen Austritt in das umliegende Gewebe, d.h. ohne Ödeme zu verursachen. Um die Methode auch für andere Institutionen brauchbar zu machen, wurde im Institut für Rechtsmedizin in Lausanne-Genf eine Forschungsgruppe gebildet, die an der Entwicklung einer spezialisierten Perfusionsmaschine für die postmortale dynamische Angiographie arbeitet, deren Bedienung möglichst einfach sein soll. Außerdem wird ein standardisiertes Protokoll zur Durchführung der Technik entwickelt, um den Einsatz von Fachkräften gering zu halten. Die Resultate der postmortalen Angiographie dienen der Auffindung von Gefäßpathologien wie Dissektionen, Gefäßmissbildungen oder Rupturen. Schwierigkeiten bereiten noch die Interpretation der Thrombosen und Embolien, da die postmortalen Gerinnungsvorgänge kritisch mit einzuziehen sind.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: We investigated the incidence and distribution of post-mortem gas detected with multidetector computed tomography (MDCT) to identify factors that could distinguish artifactual gas from cardiac air embolism. MATERIAL AND METHODS: MDCT data of 119 cadavers were retrospectively examined. Gas was semiquantitatively assessed in selected blood vessels, organs, and body spaces (82 total sites). RESULTS: Seventy-four of the 119 cadavers displayed gas (62.2%; CI 95% 52.8-70.9), and 56 (75.7%) displayed gas in the heart. Most gas was detected in the hepatic parenchyma (40%), right heart (38% ventricle, 35% atrium), inferior vena cava (30% infrarenally, 26% suprarenally), hepatic veins (26% left, 29% middle, 22% right), and portal spaces (29%). Male cadavers displayed gas more frequently than female cadavers. Gas was detected 5-84 hours after death; therefore, the post-mortem interval could not reliably predict gas distribution (rho = 0.719, p < 0.0001). We found that a large amount of putrefaction-generated gas in the right heart was associated with aggregated gas bubbles in the hepatic parenchyma (sensitivity = 100%, specificity = 89.7%). In contrast, gas in the left heart (sensitivity = 41.7%, specificity = 100%) or in periumbilical subcutaneous tissues (sensitivity = 50%, specificity = 96.3%) could not predict gas due to putrefaction. CONCLUSION: This study is the first to show that the appearance of post-mortem gas follows a specific distribution pattern. An association between intracardiac gas and hepatic parenchymal gas could distinguish between post-mortem-generated gas and vital air embolism. We propose that this finding provides a key for diagnosing death due to cardiac air embolism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

"La soirée des braves", Séance du 04.05 2011 Séminaire de Psychopathologie organisé par Daisy de Avila Seidl, Frédéric Nicod, Leslie Ponce et Renato Seidl

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multidetector computed tomography is becoming more widespread in forensic medicine. In most services, autopsy assistants perform the radiological examination. We introduced professional radiographers into the legal medicine service and hypothesized they would also be able to take over duties currently reserved for other specialists. The aims of this study were to evaluate if radiographers could be trained as "forensic radiographers" by (1) integrating graduated medical radiographers into the legal medicine service, (2) investigating the advantages of this collaboration, and (3) defining the duties of the forensic radiographers.The study was performed prospectively on a group of 8 recruited radiographers who underwent a testing period with special training. They learned the basics of medicolegal case treatment, the autonomous execution of postmortem computed tomography angiography, and postprocessing of data. Seven of 8 radiographers finished the training and were integrated into our service. Although all radiographers were able to fulfill the duties demanded after the training period, some radiographers could not enter or complete the program because they were unable to work with dead bodies.Our study presents the advantages of integrating radiographers into the medicolegal team and proposes how to train the forensic radiographers. In addition, the duties and responsibilities of these new specialists are defined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Performing a post-mortem multidetector CT (MDCT) scan has already become routine in some institutes of forensic medicine. To better visualize the vascular system, different techniques of post-mortem CT-angiography have been explored, which can essentially be divided into partial- and whole-body angiography techniques. Probably the most frequently applied technique today is the so-called multiphase post-mortem CT-angiography (MPMCTA) a standardized method for investigating the vessels of the head, thorax and abdomen. Different studies exist, describing its use for medicolegal investigations, and its advantages as well as its artefacts and pitfalls. With the aim to investigate the performance of PMCTA and to develop and validate techniques, an international working group was created in 2012 called the "Technical Working Group Post-mortem Angiography Methods" (TWGPAM). Beyond its primary perspective, the goals of this group include creating recommendations for the indication of the investigation and for the interpretation of the images and to distribute knowledge about PMCTA. This article provides an overview about the different approaches that have been developed and tested in recent years and an update about ongoing research in this field. It will explain the technique of MPMCTA in detail and give an outline of its indications, application, advantages and limitations.