10 resultados para DISTANCE MEASUREMENTS

em Université de Lausanne, Switzerland


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: Intraoperative EMG based neurophysiological monitoring is increasingly used to assist pedicle screw insertion. We carried out a study comparing the final screw position in the pedicle measured on CT images in relation to its corresponding intraoperative muscle compound action potential (CMAP) values. Material and methods: A total of 189 screws were inserted in thoracolumbar spines of 31 patients during instrumented fusion under EMG control. An observer, blinded to the CMAP value, assessed the horizontal and vertical 'screw edge to pedicle edge' distance perpendicular to the longitudinal axis of the screw on reformatted CT reconstructions using OsiriX software. These distances were analysed with their corresponding CMAP values. Data from 62 thoracic and 127 lumbar screws were processed separately. Interobserver reliability of distance measurements was assessed. Results: No patient suffered neurological injury secondary to screw insertion. Distance measurements were reliable (paired t-test, P = 0.13/0.98 horizontal/vertical). Two screws had their position altered due to low CMAP values suggesting close proximity of nerve tissue. Seventy five percent of screws had CMAP results above 10mA and had an average distance of 0.35cm (SD 0.23) horizontally and 0.46cm (SD 0.26) vertically from the pedicle edge. Additional 12% had a distance from the edge of the pedicle less than 0mm indicating cortical breach but had CMAP values above 10mA. A poor correlation between CMAP values and screw position was found. Discussion: In this study CMAP values above 10mA indicated correct screw position in the majority of cases. The zone of 10-20mA CMAP carries highest risk of a misplaced screw despite high CMAP value (17% of screws this CMAP range). In order to improve accuracy of EMG predictive value further research is warranted including improvement of probing techniques.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Object The purpose of this study was to investigate whether diffusion tensor imaging (DTI) of the corticospinal tract (CST) is a reliable surrogate for intraoperative macrostimulation through the deep brain stimulation (DBS) leads. The authors hypothesized that the distance on MRI from the DBS lead to the CST as determined by DTI would correlate with intraoperative motor thresholds from macrostimulations through the same DBS lead. Methods The authors retrospectively reviewed pre- and postoperative MRI studies and intraoperative macrostimulation recordings in 17 patients with Parkinson disease (PD) treated by DBS stimulation. Preoperative DTI tractography of the CST was coregistered with postoperative MRI studies showing the position of the DBS leads. The shortest distance and the angle from each contact of each DBS lead to the CST was automatically calculated using software-based analysis. The distance measurements calculated for each contact were evaluated with respect to the intraoperative voltage thresholds that elicited a motor response at each contact. Results There was a nonsignificant trend for voltage thresholds to increase when the distances between the DBS leads and the CST increased. There was a significant correlation between the angle and the voltage, but the correlation was weak (coefficient of correlation [R] = 0.36). Conclusions Caution needs to be exercised when using DTI tractography information to guide DBS lead placement in patients with PD. Further studies are needed to compare DTI tractography measurements with other approaches such as microelectrode recordings and conventional intraoperative MRI-guided placement of DBS leads.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Raman spectroscopy combined with chemometrics has recently become a widespread technique for the analysis of pharmaceutical solid forms. The application presented in this paper is the investigation of counterfeit medicines. This increasingly serious issue involves networks that are an integral part of industrialized organized crime. Efficient analytical tools are consequently required to fight against it. Quick and reliable authentication means are needed to allow the deployment of measures from the company and the authorities. For this purpose a method in two steps has been implemented here. The first step enables the identification of pharmaceutical tablets and capsules and the detection of their counterfeits. A nonlinear classification method, the Support Vector Machines (SVM), is computed together with a correlation with the database and the detection of Active Pharmaceutical Ingredient (API) peaks in the suspect product. If a counterfeit is detected, the second step allows its chemical profiling among former counterfeits in a forensic intelligence perspective. For this second step a classification based on Principal Component Analysis (PCA) and correlation distance measurements is applied to the Raman spectra of the counterfeits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Revolutionary endovascular treatments are on the verge of being available for management of ascending aortic diseases. Morphometric measurements of the ascending aorta have already been done with ECG-gated MDCT to help such therapeutic development. However the reliability of these measurements remains unknown. The objective of this work was to compare the intraobserver and interobserver variability of CAD (computer aided diagnosis) versus manual measurements in the ascending aorta. Methods and materials: Twenty-six consecutive patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters at mid-distance between the brachiocephalic artery and the aortic valve were obtained automatically with a commercially available CAD and manually by two observers separately. Both observers repeated the measurements during a different session at least one month after the first measurements. Intraclass coefficients as well the Bland and Altman method were used for comparison between measurements. Two-paired t-test was used to determine the significance of intraobserver and interobserver differences (alpha = 0.05). Results: There is a significant difference between CAD and manual measurements in the maximum diameter (p = 0.004) for the first observer, whereas the difference was significant for minimum diameter between the second observer and the CAD (p <0.001). Interobserver variability showed a weak agreement when measurements were done manually. Intraobserver variability was lower with the CAD compared to the manual measurements (limits of variability: from -0.7 to 0.9 mm for the former and from -1.2 to 1.3 mm for the latter). Conclusion: In order to improve reproductibility of measurements whenever needed, pre- and post-therapeutic management of the ascending aorta may benefit from follow-up done by a unique observer with the help of CAD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rapport de synthèse : Mesures de l'aorte ascendante par scanner synchronisé au rythme cardiaque: une étude pilote pour établir des valeurs normatives dans le cadre des futures thérapies par transcathéter. Objectif : L'objectif de cette étude est d'établir les valeurs morphométriques normatives de l'aorte ascendante à l'aide de l'angiographie par scanner synchronisé au rythme cardiaque, afin d'aider au développement des futurs traitements par transcathéter. Matériels et méthodes : Chez soixante-dix-sept patients (âgé de 22 à 83 ans, âge moyen: 54,7 ans), une angiographie par scanner synchronisé au rythme cardiaque a été réalisée pour évaluation des vaisseaux coronaires. Les examens ont été revus afin d'étudier l'anatomie de la chambre de chasse du ventricule gauche jusqu'au tronc brachio-céphalique droit. A l'aide de programmes de reconstructions multiplanaires et de segmentation automatique, différents diamètres et longueurs considérés comme importants pour les futurs traitements par transcathéter ont été mesurés. Les valeurs sont exprimées en moyennes, médianes, maximums, minimums, écart-types et en coefficients de variation. Les variations de diamètre de l'aorte ascendante durant le cycle cardiaque ont été aussi considérées. Résultats : Le diamètre moyen de la chambre de chasse du ventricule gauche était de 20.3+/-3.4 mm. Au niveau du sinus coronaire de l'aorte, il était de 34.2+/-4.1 mm et au niveau de la jonction sinotubulaire il était de 29.7+/-3.4 mm. Le diamètre moyen de l'aorte ascendante était de 32.7+/-3.8 mm. Le coefficient de variation de ces mesures variait de 12 à 17%. La distance moyenne entre l'insertion proximale des valvules aortiques et le départ du tronc brachio-céphalique droit était de 92.6+/-11.8 mm. La distance moyenne entre l'insertion proximale des valvules aortiques et l'origine de l'artère coronaire proximale était de 12.1+/-3.7 mm avec un coefficient de variation de 31%. La distance moyenne entre les deux ostia coronaires était de 7.2+/-3.1 mm avec un coefficient de variation de 43%. La longueur moyenne du petit arc de l'aorte ascendante entre l'artère coronaire gauche et le tronc brachio-céphalique droit était de 52.9+/-9.5 mm. La longueur moyenne de la continuité fibreuse entre la valve aortique et la valvule mitrale antérieure était de 14.6+/-3.3 mm avec un coefficient de variation de 23%. L'aire moyenne de la valve aortique était de 582.0+/-131.9 mm2. La variation du diamètre antéro-postérieur et transverse de l'aorte ascendante était respectivement de 8.4% et de 7.3%. Conclusion Il existe d'importantes variations inter-individuelles dans les mesures de l'aorte ascendante avec cependant des variations intra-individuelles faibles durant le cycle cardiaque. De ce fait, une approche personnalisée pour chaque patient est recommandée dans la confection des futures endoprothèses de l'aorte ascendante. Le scanner synchronisé au rythme cardiaque jouera un rôle prépondérant dans le bilan préthérapeutique. Abstract : The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3+/-3.4, coronary sinus 34.2+/-4.1, sinotubular junction 29.7+-3.4 and mid ascending aorta 32.7+/-3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6111.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1+/-3.7, and between both coronary ostia 7.2+/-3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 X9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.óf3.3, CV 13-43%. Mean aortic valve area was 582+-131.9 mm2. The variations of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Laboratory safety data are routinely collected in clinical studies for safety monitoring and assessment. We have developed a truncated robust multivariate outlier detection method for identifying subjects with clinically relevant abnormal laboratory measurements. The proposed method can be applied to historical clinical data to establish a multivariate decision boundary that can then be used for future clinical trial laboratory safety data monitoring and assessment. Simulations demonstrate that the proposed method has the ability to detect relevant outliers while automatically excluding irrelevant outliers. Two examples from actual clinical studies are used to illustrate the use of this method for identifying clinically relevant outliers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The beneficial effect of physical exercise on bone mineral density (BMD) is at least partly explained by the forces exerted directly on the bones. Male runners present generally higher BMD than sedentary individuals. We postulated that the proximal tibia BMD is related to the running distance as well as to the magnitude of the shocks (while running) in male runners. Methods: A prospective study (three yearly measurements) included 81 healthy male subjects: 16 sedentary lean subjects and three groups of runners (5-30 km/week, n=19; 30-50 km/week, n=29; 50-100 km/week, n=17). Several measurements were performed at the proximal tibia level: volumetric BMD (vBMD), cortical index (CI) i.e. an index of cortical bone thickness and peak accelerations (an index of shocks during heel strike) while running (measured by a 3-D accelerometer). A general linear model assessed the prediction of vBMD or CI by a) simple effects (running distance, peak accelerations, time) and b) interactions (for instance if vBMD prediction by peak acceleration depends on running distance). Results: CI and vBMD a) increase with running distance to reach a plateau over 30 km/wk, b) are positively associated with peak accelerations over 30 km/week. Discussion: Running may be associated with high peak accelerations in order to have beneficial effects on BMD. More important strains are needed to be associated with the same increase in BMD during running sessions of short duration than those of long duration. Conclusion: CI and vBMD are associated with the magnitude of the shocks during heel strike in runners. Key words: Bone mineral density, strains, physical exercise, running distance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The leaves of all plants use elaborate and inducible defence systems to protect themselves. A wide variety of such defences are known and they include defence chemicals such as alkaloids, phenolics and terpenes, physical structures ranging from fibre cells to silica deposits, and a wide variety of defence proteins many of which target digestive processes in herbivores. It has long been known that the defence responses of plants under attack by insects are not restricted to the site of attack. Instead, if a leaf is damaged, defence can be triggered in other parts of the plant body, for example in distal leaves or even in roots and flowers. This raises the question of what are the organ-to-organ signals that coordinate this process. Several hypotheses have been proposed. These include the long-distance transfer of chemical signals through the plant vasculature, hydraulic signals that may transit through the xylem, and electrical signals that would move through living tissues such as the phloem. Much evidence for each of these scenarios has been published. In this thesis we took advantage of the fact that many plant defence responses are regulated by a signal transduction pathway based on a molecule called jasmonic acid. We used this molecule, one of its derivatives (jasmonoyl-isoleucine), and some of the genes it regulates as markers. Using these we investigated the possible role of the electrical signals in the leaf- to-leaf activation of the jasmonate pathway. We found that feeding insects stimulate easily detected electrical activity in the leaves of Arabidopsis thaliana and we used non-invasive surface electrodes to record this activity. This approach showed that jasmonate pathway activity and the electrical activity provoked by mechanical wounding occurred within identical spatial boundaries. Measurements of the apparent speed of surface potentials agreed well with previous velocity estimates for the speed of leaf-to-leaf signals that activate the jasmonate pathway. Using this knowledge we were able to investigate the effects of current injection into Arabidopsis leaves. This resulted in the strong expression of many jasmonate-regulated genes. All these results showed that electrical activity and the activation of jasmonate signalling were highly correlated. In order to test for possible causal links between the two processes, we conducted a small-scale reverse genetic screen on a series of T-DNA insertion mutants in ion channel genes and in other genes encoding proteins such as proton pumps. This screen, which was based on surface potential measurements, revealed that mutations in genes related to ionotropic glutamate receptors in animals had impaired electrical activity after wounding. Combining mutation of two of these glutamate-receptor-like genes in a double mutant reduced the response of leaves to current injection. When a leaf of this double mutant was wounded it failed to transmit a long-distance signal to a distal leaf. This result distinguished the double mutant from the wild-type plant and provides the first genetic evidence that electrical signalling is necessary to coordinate defence responses between organs in plants. - Les feuilles des plantes disposent de systèmes de défense inductibles très élaborés. Un grand nombre de ces systèmes de défenses sont connus et sont basés sur des composés chimiques comme les alcaloïdes, les composés phénoliques ou les terpènes, des systèmes physiques allant de la production de cellules fibreuses aux cristaux de silice ainsi qu'un grand nombre de protéines de défense ciblant le processus digestif des herbivores. Il est connu dépuis longtemps que la réponse défensive de la plante face à l'attaque pas un insecte n'est pas seulement localisée au niveau de la zone d'attaque. A la place, si une feuille est attaquée, les systèmes de défense peuvent être activés ailleurs dans la plante, comme par exemple dans d'autres feuilles, les racines ou même les fleurs. Ces observations soulèvent la question de la nature des signaux d'organes à organes qui régulent ces systèmes. Plusieurs hypothèses ont été formulées; une ou plusieures molécules pourraient être véhiculées dans la plante grâce au système vasculaire, un signal hydraulique transmis au travers du xylème ou encore des signaux électriques transmis par les cellules comme dans le phloème par exemple. De nombreuses études ont été publiées sur ces différentes hypothèses. Dans ce travail de thèse, nous avons choisi d'utiliser à notre avantage le fait que de nombreuses réponses de défense de la plante sont régulées par une même voie de signalisation utilisant l'acide jasmonique. Nous avons utilisé comme marqueurs cette molécule, un de ses dérivés (le jasmonoyl-isoleucine) ainsi que certains des gènes que l'acide jasmonique régule. Nous avons alors testé l'implication de la transmission de signaux électriques dans l'activation de la voie du jasmonate de feuille à feuille. Nous avons découvert que les insectes qui se nourrissent de feuilles d'Arabidopsis thaliana activent un signal électrique que nous avons pu mesurer grâce à une technique non invasive d'électrodes de surface. Les enregistrements ont montré que la génération de signaux électriques et l'activation de la voie du jasmonate avaient lieu aux mêmes endroits. La mesure de la vitesse de déplacement des impulsions électriques correspond aux estimations faites concernant l'activation de la voie du jasmonate. Grâce à cela, nous avons pu tester l'effet d'injection de courant électrique dans les feuilles d'Arabidopsis. La conséquence a été une forte expression de nombreux gènes de la voie du jasmonate, suggérant une forte corrélation entre l'activité électrique et l'activation de la voie du jasmonate. Afin de tester le lien de cause entre ces deux phénomènes, nous avons entrepris un criblage génétique sur une série de mutants d'insertion à l'ADN-T dans des gènes de canaux ioniques et d'autres gènes d'intérêt comme les gènes des pompes à protons. Ce criblage, basé sur la mesure de potentiels de surface, a permis de montrer que plusieurs mutations de gènes liés aux récepteurs au glutamate ionotropique présentent une baisse drastique de leurs activités électriques après une blessure mécanique des feuilles par rapport au type sauvage. Par la combinaison de deux mutations de ces récepteurs au glutamate en un double mutant, on obtient une réponse à la stimulation électrique encore plus faible. Quand une feuille du double mutant est blessée, elle est incapable de transmettre un signal à longue distance vers une feuille éloignée. Ce résultat permet de distinguer le double mutant de la plante sauvage et amène la première preuve génétique que l'activité électrique est nécessaire pour coordonner les réponses de défense entre les organes chez les plantes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Ankle arthrodesis (AD) and total ankle replacement (TAR) are typical treatments for ankle osteoarthritis (AO). Despite clinical interest, there is a lack of their outcome evaluation using objective criteria. Gait analysis and plantar pressure assessment are appropriate to detect pathologies in orthopaedics but they are mostly used in lab with few gait cycles. In this study, we propose an ambulatory device based on inertial and plantar pressure sensors to compare the gait during long-distance trials between healthy subjects (H) and patients with AO or treated by AD and TAR. Methods: Our study included four groups: 11 patients with AO, 9 treated by TAR, 7 treated by AD and 6 control subjects. An ambulatory system (Physilog®, CH) was used for gait analysis; plantar pressure measurements were done using a portable insole (Pedar®-X, DE). The subjects were asked to walk 50 meters in two trials. Mean value and coefficient of variation of spatio-temporal gait parameters were calculated for each trial. Pressure distribution was analyzed in ten subregions of foot. All parameters were compared among the four groups using multi-level model-based statistical analysis. Results: Significant difference (p <0.05) with control was noticed for AO patients in maximum force in medial hindfoot and forefoot and in central forefoot. These differences were no longer significant in TAR and AD groups. Cadence and speed of all pathologic groups showed significant difference with control. Both treatments showed a significant improvement in double support and stance. TAR decreased variability in speed, stride length and knee ROM. Conclusions: In spite of a small sample size, this study showed that ankle function after AO treatments can be evaluated objectively based on plantar pressure and spatio-temporal gait parameters measured during unconstrained walking outside the lab. The combination of these two ambulatory techniques provides a promising way to evaluate foot function in clinics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the evaluation results of the methods submitted to Challenge US: Biometric Measurements from Fetal Ultrasound Images, a segmentation challenge held at the IEEE International Symposium on Biomedical Imaging 2012. The challenge was set to compare and evaluate current fetal ultrasound image segmentation methods. It consisted of automatically segmenting fetal anatomical structures to measure standard obstetric biometric parameters, from 2D fetal ultrasound images taken on fetuses at different gestational ages (21 weeks, 28 weeks, and 33 weeks) and with varying image quality to reflect data encountered in real clinical environments. Four independent sub-challenges were proposed, according to the objects of interest measured in clinical practice: abdomen, head, femur, and whole fetus. Five teams participated in the head sub-challenge and two teams in the femur sub-challenge, including one team who tackled both. Nobody attempted the abdomen and whole fetus sub-challenges. The challenge goals were two-fold and the participants were asked to submit the segmentation results as well as the measurements derived from the segmented objects. Extensive quantitative (region-based, distance-based, and Bland-Altman measurements) and qualitative evaluation was performed to compare the results from a representative selection of current methods submitted to the challenge. Several experts (three for the head sub-challenge and two for the femur sub-challenge), with different degrees of expertise, manually delineated the objects of interest to define the ground truth used within the evaluation framework. For the head sub-challenge, several groups produced results that could be potentially used in clinical settings, with comparable performance to manual delineations. The femur sub-challenge had inferior performance to the head sub-challenge due to the fact that it is a harder segmentation problem and that the techniques presented relied more on the femur's appearance.