Resumo:

OBJECT: In this study the accuracy of multislice computerized tomography (MSCT) angiography in the postoperative examination of clip-occluded intracranial aneurysms was compared with that of intraarterial digital subtraction (DS) angiography METHODS: Forty-nine consecutive patients with 60 clipped aneurysms (41 of which had ruptured) were studied with the aid of postoperative MSCT and DS angiography. Both types of radiological studies were reviewed independently by two observers to assess the quality of the images, the artifacts left by the clips, the completeness of aneurysm occlusion, the patency of the parent vessel, and the duration and cost of the examination. The quality of MSCT angiography was good in 42 patients (86%). Poor-quality MSCT angiograms (14%) were a result of the late acquisition of images in three patients and the presence of clip or motion artifacts in four. Occlusion of the aneurysm on good-quality MSCT angiograms was confirmed in all but two patients in whom a small (2-mm) remnant was confirmed on DS angiograms. In one patient, occlusion of a parent vessel was seen on DS angiograms but missed on MSCT angiograms. The sensitivity and specificity for detecting neck remnants on MSCT angiography were both 100%, and the sensitivity and specificity for evaluating vessel patency were 80 and 100%, respectively (95% confidence interval 29.2-100%). Interobserver agreements were 0.765 and 0.86, respectively. The mean duration of the examination was 13 minutes for MSCT angiography and 75 minutes for DS angiography (p < 0.05). Multislice CT angiography was highly cost effective (p < 0.01). CONCLUSIONS: Current-generation MSCT angiography is an accurate noninvasive tool used for assessment of clipped aneurysms in the anterior circulation. Its high sensitivity and low cost warrant its use for postoperative routine control examinations following clip placement on an aneurysm. Digital subtraction angiography must be performed if the interpretation of MSCT angiograms is doubtful or if the aneurysm is located in the posterior circulation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To assess the technical feasibility of multi-detector row computed tomographic (CT) angiography in the assessment of peripheral arterial bypass grafts and to evaluate its accuracy and reliability in the detection of graft-related complications, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. MATERIALS AND METHODS: Four-channel multi-detector row CT angiography was performed in 65 consecutive patients with 85 peripheral arterial bypass grafts. Each bypass graft was divided into three segments (proximal anastomosis, course of the graft body, and distal anastomosis), resulting in 255 segments. Two readers evaluated all CT angiograms with regard to image quality and the presence of bypass graft-related abnormalities, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. The results were compared with McNemar test with Bonferroni correction. CT attenuation values were recorded at five different locations from the inflow artery to the outflow artery of the bypass graft. These findings were compared with the findings at duplex ultrasonography (US) in 65 patients and the findings at conventional digital subtraction angiography (DSA) in 27. RESULTS: Image quality was rated as good or excellent in 250 (98%) and in 252 (99%) of 255 bypass segments, respectively. There was excellent agreement both between readers and between CT angiography and duplex US in the detection of graft stenosis, aneurysmal changes, and arteriovenous fistulas (kappa = 0.86-0.99). CT angiography and duplex US were compared with conventional DSA, and there was no statistically significant difference (P >.25) in sensitivity or specificity between CT angiography and duplex US for both readers for detection of hemodynamically significant bypass stenosis or occlusion, aneurysmal changes, or arteriovenous fistulas. Mean CT attenuation values ranged from 232 HU in the inflow artery to 281 HU in the outflow artery of the bypass graft. CONCLUSION: Multi-detector row CT angiography may be an accurate and reliable technique after duplex US in the assessment of peripheral arterial bypass grafts and detection of graft-related complications, including stenosis, aneurysmal changes, and arteriovenous fistulas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Management of brain arteriovenous malformation (bAVM) is controversial. We have analyzed the largest surgical bAVM cohort for outcome. METHODS: Both operated and nonoperated cases were included for analysis. A total of 779 patients with bAVMs were consecutively enrolled between 1989 and 2014. Initial management recommendations were recorded before commencement of treatment. Surgical outcome was prospectively recorded and outcomes assigned at the last follow-up visit using modified Rankin Scale. First, a sensitivity analyses was performed to select a subset of the entire cohort for which the results of surgery could be generalized. Second, from this subset, variables were analyzed for risk of deficit or near miss (intraoperative hemorrhage requiring blood transfusion of ≥2.5 L, hemorrhage in resection bed requiring reoperation, and hemorrhage associated with either digital subtraction angiography or embolization). RESULTS: A total of 7.7% of patients with Spetzler-Ponce classes A and B bAVM had an adverse outcome from surgery leading to a modified Rankin Scale >1. Sensitivity analyses that demonstrated outcome results were not subject to selection bias for Spetzler-Ponce classes A and B bAVMs. Risk factors for adverse outcomes from surgery for these bAVMs include size, presence of deep venous drainage, and eloquent location. Preoperative embolization did not affect the risk of perioperative hemorrhage. CONCLUSIONS: Most of the ruptured and unruptured low and middle-grade bAVMs (Spetzler-Ponce A and B) can be surgically treated with a low risk of permanent morbidity and a high likelihood of preventing future hemorrhage. Our results do not apply to Spetzler-Ponce C bAVMs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Management of brain arteriovenous malformation (bAVM) is controversial. We have analyzed the largest surgical bAVM cohort for outcome. METHODS: Both operated and nonoperated cases were included for analysis. A total of 779 patients with bAVMs were consecutively enrolled between 1989 and 2014. Initial management recommendations were recorded before commencement of treatment. Surgical outcome was prospectively recorded and outcomes assigned at the last follow-up visit using modified Rankin Scale. First, a sensitivity analyses was performed to select a subset of the entire cohort for which the results of surgery could be generalized. Second, from this subset, variables were analyzed for risk of deficit or near miss (intraoperative hemorrhage requiring blood transfusion of ≥2.5 L, hemorrhage in resection bed requiring reoperation, and hemorrhage associated with either digital subtraction angiography or embolization). RESULTS: A total of 7.7% of patients with Spetzler-Ponce classes A and B bAVM had an adverse outcome from surgery leading to a modified Rankin Scale >1. Sensitivity analyses that demonstrated outcome results were not subject to selection bias for Spetzler-Ponce classes A and B bAVMs. Risk factors for adverse outcomes from surgery for these bAVMs include size, presence of deep venous drainage, and eloquent location. Preoperative embolization did not affect the risk of perioperative hemorrhage. CONCLUSIONS: Most of the ruptured and unruptured low and middle-grade bAVMs (Spetzler-Ponce A and B) can be surgically treated with a low risk of permanent morbidity and a high likelihood of preventing future hemorrhage. Our results do not apply to Spetzler-Ponce C bAVMs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A 28-year-old woman consulted for disabling pulsatile tinnitus. Clinical examination suggested a venous etiology. An aneurysm of the transverse-sigmoid sinus was identified on computed tomography angiography (CTA) and confirmed by digital subtraction angiography. Endovascular occlusion of the aneurysm with detachable coils permanently eliminated the bruit. Thus, this report is of a new case of pulsatile tinnitus caused by an aneurysm of the transverse-sigmoid sinus, with a focus on a literature review and etiopathophysiology. Embryological studies suggest that these aneurysms represent a partial remnant of the petrosquamous sinus.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIM: Chronic critical limb ischemia (CLI) often requires venous bypass grafting to distal arterial segments. However, graft patency is influenced by the length and quality of the graft and occasionally patients may have limited suitable veins. We investigated short distal bypass grafting from the superficial femoral or popliteal artery to the infrapopliteal, ankle or foot arteries, despite angiographic alterations of inflow vessels, providing that invasive pressure measurement at the site of the planned proximal anastomosis revealed an inflow-brachial pressure difference of <or=10 mmHg. METHODS: Four hundred and twenty-three consecutive infrainguinal bypass grafts were performed for CLI between June, 1999 and November, 2002 at our institution. All patients underwent preoperative clinical examination, arteriography and assessment of the veins by duplex ultrasound. The study group are patients in whom the proximal and distal anastomoses of the bypass are below the femoral bifurcation and the popliteal artery, respectively. Invasive arterial pressure measurements were recorded at the level of the planned proximal anastomosis which was performed at that level if the difference of the inflow-brachial pressure was <or=10 mmHg, irrespective of angiographic alterations of the inflow vessels proximal to the planned anastomosis. All patients had a clinical follow-up included a duplex examination of their graft, at 1 week, 3, 9 and 12 months and, thereafter, annually. No patient was lost to follow-up. RESULTS: Sixty-seven patients underwent 71 short distal bypass grafts in 71 limbs with reversed saphenous vein grafts in 52, in situ saphenous veins in 11, reversed cephalic vein in 1 and composite veins in 7, respectively. Surgical or endovascular interventions to improve inflow were required in 4 limbs (5.6%). The mean follow-up time was 22.5 months and the two-year survival was 92.5%. Primary and secondary patency rates at 2 years were 73% and 93%, respectively, and the limb salvage rate was 98.5%. CONCLUSION: In appropriately selected patients, short distal venous bypass grafts can be performed with satisfactory patency and limb salvage rates even in the presence of morphologic alterations of the inflow vessels providing that these are not hemodynamically significant, or can be corrected intraoperatively.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective was to design a vascular phantom compatible with digital subtraction angiography, computerized tomography angiography, ultrasound and magnetic resonance angiography (MRA). Fiducial markers were implanted at precise known locations in the phantom to facilitate identification and orientation of plane views from three-dimensional (3-D) reconstructed images. A vascular conduit connected to tubing at the extremities of the phantom ran through an agar-based gel filling it. A vessel wall in latex was included around the conduit to avoid diffusion of contrast agents. Using a lost-material casting technique based on a low melting point metal, geometries of pathological vessels were modeled. During the experimental testing, fiducial markers were detectable in all modalities without distortion. No leak of gadolinium through the vascular wall was observed on MRA after 5 hours. Moreover, no significant deformation of the vascular conduit was noted during the fabrication process (confirmed by microtome slicing along the vessel). The potential use of the phantom for calibration, rescaling, and fusion of 3-D images obtained from the different modalities as well as its use for the evaluation of intra- and inter-modality comparative studies of imaging systems are discussed. In conclusion, the vascular phantom can allow accurate calibration of radiological imaging devices based on x-ray, magnetic resonance and ultrasound and quantitative comparisons of the geometric accuracy of the vessel lumen obtained with each of these methods on a given well defined 3-D geometry.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to compare the diagnostic value of post-mortem computed tomography angiography (PMCTA) to conventional, ante-mortem computed tomography (CT)-scan, CT-angiography (CTA) and digital subtraction angiography (DSA) in the detection and localization of the source of bleeding in cases of acute hemorrhage with fatal outcomes. The medical records and imaging scans of nine individuals who underwent a conventional, ante-mortem CT-scan, CTA or DSA and later died in the hospital as a result of an acute hemorrhage were reviewed. Post-mortem computed tomography angiography, using multi-phase post-mortem CTA, as well as medico-legal autopsies were performed. Localization accuracy of the bleeding was assessed by comparing the diagnostic findings of the different techniques. The results revealed that data from ante-mortem and post-mortem radiological examinations were similar, though the PMCTA showed a higher sensitivity for detecting the hemorrhage source than did ante-mortem radiological investigations. By comparing the results of PMCTA and conventional autopsy, much higher sensitivity was noted in PMCTA in identifying the source of the bleeding. In fact, the vessels involved were identified in eight out of nine cases using PMCTA and only in three cases through conventional autopsy. Our study showed that PMCTA, similar to clinical radiological investigations, is able to precisely identify lesions of arterial and/or venous vessels and thus determine the source of bleeding in cases of acute hemorrhages with fatal outcomes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: To identify patients with spontaneous subarachnoid hemorrhage for whom CT angiography alone can exclude ruptured aneurysms. METHODS: An observational retrospective review was carried out of all consecutive patients with non-traumatic subarachnoid hemorrhage who underwent both CT angiography and catheter angiography to exclude an aneurysm. CT angiography negative cases (no aneurysm) were classified according to their CT hemorrhage pattern as "aneurismal", "perimesencephalic" or as "no-hemorrhage." RESULTS: Two hundred and forty-one patients were included. A CT angiography aneurysm detection sensitivity and specificity of 96.4% and 96.0% were observed. All 35 cases of perimesencephalic or no-hemorrhage out of 78 CT angiography negatives also had negative angiography findings. CONCLUSIONS: CT angiography is self-reliant to exclude ruptured aneurysms when either a perimesencephalic hemorrhage or no-hemorrhage pattern is identified on the CT within a week of symptom onset.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to evaluate helical CT angiography in the assessment of occlusive arterial disease of abdominal aorta and the lower extremities. Sixteen patients underwent both transcatheter angiography and helical CT. Helical CT was inconclusive in 6.2% of segments whereas angiography was inconclusive in 5%. The overall sensitivity of helical CT was 91% and specificity 93%. Segmental analysis found a sensitivity of 43% in infrapopliteal arteries, and a specificity of 86%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 1903, the eastern slope of Turtle Mountain (Alberta) was affected by a 30 M m3-rockslide named Frank Slide that resulted in more than 70 casualties. Assuming that the main discontinuity sets, including bedding, control part of the slope morphology, the structural features of Turtle Mountain were investigated using a digital elevation model (DEM). Using new landscape analysis techniques, we have identified three main joint and fault sets. These results are in agreement with those sets identified through field observations. Landscape analysis techniques, using a DEM, confirm and refine the most recent geology model of the Frank Slide. The rockslide was initiated along bedding and a fault at the base of the slope and propagated up slope by a regressive process following a surface composed of pre-existing discontinuities. The DEM analysis also permits the identification of important geological structures along the 1903 slide scar. Based on the so called Sloping Local Base Level (SLBL) an estimation was made of the present unstable volumes in the main scar delimited by the cracks, and around the south area of the scar (South Peak). The SLBL is a method permitting a geometric interpretation of the failure surface based on a DEM. Finally we propose a failure mechanism permitting the progressive failure of the rock mass that considers gentle dipping wedges (30°). The prisms or wedges defined by two discontinuity sets permit the creation of a failure surface by progressive failure. Such structures are more commonly observed in recent rockslides. This method is efficient and is recommended as a preliminary analysis prior to field investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Red blood cell (RBC) parameters such as morphology, volume, refractive index, and hemoglobin content are of great importance for diagnostic purposes. Existing approaches require complicated calibration procedures and robust cell perturbation. As a result, reference values for normal RBC differ depending on the method used. We present a way for measuring parameters of intact individual RBCs by using digital holographic microscopy (DHM), a new interferometric and label-free technique with nanometric axial sensitivity. The results are compared with values achieved by conventional techniques for RBC of the same donor and previously published figures. A DHM equipped with a laser diode (lambda = 663 nm) was used to record holograms in an off-axis geometry. Measurements of both RBC refractive indices and volumes were achieved via monitoring the quantitative phase map of RBC by means of a sequential perfusion of two isotonic solutions with different refractive indices obtained by the use of Nycodenz (decoupling procedure). Volume of RBCs labeled by membrane dye Dil was analyzed by confocal microscopy. The mean cell volume (MCV), red blood cell distribution width (RDW), and mean cell hemoglobin concentration (MCHC) were also measured with an impedance volume analyzer. DHM yielded RBC refractive index n = 1.418 +/- 0.012, volume 83 +/- 14 fl, MCH = 29.9 pg, and MCHC 362 +/- 40 g/l. Erythrocyte MCV, MCH, and MCHC achieved by an impedance volume analyzer were 82 fl, 28.6 pg, and 349 g/l, respectively. Confocal microscopy yielded 91 +/- 17 fl for RBC volume. In conclusion, DHM in combination with a decoupling procedure allows measuring noninvasively volume, refractive index, and hemoglobin content of single-living RBCs with a high accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The transmembrane water movements during cellular processes and their relationship to ionic channel activity remain largely unknown. As an example, in epithelial cells it was proposed that the movement of water could be directly linked to cystic fibrosis transmembrane conductance regulator (CFTR) protein activity through a cAMP-stimulated aqueous pore, or be dependent on aquaporin. Here, we used digital holographic microscopy (DHM) an interferometric technique to quantify in situ the transmembrane water fluxes during the activity of the epithelial chloride channel, CFTR, measured by patch-clamp and iodide efflux techniques. We showed that the water transport measured by DHM is fully inhibited by the selective CFTR blocker CFTRinh172 and is absent in cells lacking CFTR. Of note, in cells expressing the mutated version of CFTR (F508del-CFTR), which mimics the most common genetic alteration encountered in cystic fibrosis, we also show that the water movement is profoundly altered but restored by pharmacological manipulation of F508del-CFTR-defective trafficking. Importantly, whereas activation of this endogenous water channel required a cAMP-dependent stimulation of CFTR, activation of CFTR or F508del-CFTR by two cAMP-independent CFTR activators, genistein and MPB91, failed to trigger water movements. Finally, using a specific small-interfering RNA against the endogenous aquaporin AQP3, the water transport accompanying CFTR activity decreased. We conclude that water fluxes accompanying CFTR activity are linked to AQP3 but not to a cAMP-stimulated aqueous pore in the CFTR protein.