194 resultados para Continuum removal technique

em Université de Lausanne, Switzerland


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background : Port-related bloodstream infection (PRBSI) is a common complication associated with long-term use of ports systems. Systemic antimicrobial therapy (ST) and removal of the device is the standard management of PRBSI. However, a conservative management combining ST with antibiotic lock therapy (ALT) without port removal has been suggested as an alternative management option for infections due to gram-positive skin colonizers with low virulence.¦Objectives : i) to assess the frequency of management of PRBSI in onco-hematological patients by combining the ALT with ST, without catheter removal and ii) to analyze the efficacy of such an approach.¦Methods : Retrospective observational study over a 6-year period between 2005 and 2010, including patients who where diagnosed with PRBSI and who were treated with ST and ALT. PRBSI diagnosis consisted in clinical signs of bacteremia with blood cultures positive for gram-positive skin colonizers. The primary endpoint was failure to cure the PRBSI.¦Results : 61 port infections were analysed, of which 23 PRBSI met the inclusion criteria. All the patients were suffering from haematological conditions and 75% were neutropenic at the time of PRBSI diagnosis. S. epidermidis was responsible for 91% of PRBSI (21/23). The median duration of ST was 14 days (range 7-35) and the median duration of ALT was 15 days (range 8-41). Failure to cure the PRBSI requiring port removal was observed in 4 patients, but was not associated with severe infectious complications. Kaplan-Meier analysis showed a success rate in port salvage at day 180 (6 months) of 78% (95%CI 59-97%).¦Conclusion : The success rate observed in the present study suggests that combining ST and ALT is an effective option to conservatively treat PRBSI caused by pathogens of low virulence such as S. epidermidis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Metallic foreign bodies are rarely found in the maxillary sinus, and usually they have a dental origin.Potential complications related to foreign bodies include recurrent sinusitis, rhinolith formation, cutaneous fistula,chemical poisoning, facial neuralgic pain and even malignancies.Two main surgical approaches are currently used for the removal of foreign bodies in the maxillary sinus: the bone flap and the endoscopic sinus techniques. We are reporting two unusual cases of large high-velocity foreign bodies removed by a modified maxillary lateral antrotomy,with free bone flap repositioning and fixation with a titanium miniplate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Retained T-tubes are rare complications after biliary surgery. The authors present three cases of retained T-tubes in patients with transplanted liver that could not be removed by a standard manual traction. The authors describe a new simple percutaneous method that allows removal of these T-tubes without complication.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Controversy exists about the best method to achieve bone fusion in four-corner arthrodesis. Thirty-five patients who underwent this procedure by our technique were included in the study. Surgical indications were stage II-III SLAC wrist, stage II SNAC wrist and severe traumatic midcarpal joint injury. Mean follow-up was 4.6 years. Mean active flexion and extension were 34 degrees and 30 degrees respectively; grip strength recovery was 79%. Radiological consolidation was achieved in all cases. The mean DASH score was 23 and the postoperative pain improvement by visual analogue scale was statistically significant. Return to work was possible at 4 months for the average patient. Complications were a capitate fracture in one patient and the need for hardware removal in four cases. Four-corner bone wrist arthrodesis by dorsal rectangular plating achieves an acceptable preservation of range of motion with good pain relief, an excellent consolidation rate and minimal complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SUMMARY: Coil displacement during endovascular coiling procedures may require coil retrieval in the context of flow limitation or thromboembolic risk. No standard recommended method of coil retrieval exists. We present a consecutive series of 14 patients with displaced coil during aneurysm coiling in whom the complication was effectively managed with the use of a stent retriever system. Two illustrative cases from the 14 are described, and technical notes are detailed regarding use of the technique. The use of stent retrievers presents a simple, safe, and effective choice for removal of prolapsed coils during aneurysm coiling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intraoperative cardiac imaging plays a key role during transcatheter aortic valve replacement. In recent years, new techniques and new tools for improved image quality and virtual navigation have been proposed, in order to simplify and standardize stent valve positioning and implantation. But routine performance of the new techniques may require major economic investments or specific knowledge and skills and, for this reason, they may not be accessible to the majority of cardiac centres involved in transcatheter valve replacement projects. Additionally, they still require injections of contrast medium to obtain computed images. Therefore, we have developed and describe here a very simple and intuitive method of positioning balloon-expandable stent valves, which represents the evolution of the 'dumbbell' technique for echocardiography-guided transcatheter valve replacement without angiography. This method, based on the partial inflation of the balloon catheter during positioning, traps the crimped valve in the aortic valve orifice and, consequently, very near to the ideal landing zone. It does not require specific echocardiographic knowledge; it does not require angiographies that increase the risk of postoperative kidney failure in elderly patients, and it can be also performed in centres not equipped with a hybrid operating room.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: Standardization of surgical technique helps to reproduce excellent clinical outcomes, especially in teaching institutions. We aim to describe in detail our established approach for oncological right colectomy. TECHNIQUE: The right colon is mobilized in a five-step latero-inferior approach starting off with (1) the terminal ileum, visualizing the duodenum and the head of pancreas. (2) The ascending colon is dissected from the retroperitoneum, and takedown of the hepatic flexure is completed coming retrograde from the transverse colon (3). (4) Transection of the remaining retroperitoneal attachments completes exposure of the duodenum and mobilization of the right colon. (5) Ileocolic vessels are dissected out and divided close to their origin, and the mesocolon is divided. We then establish intestinal continuity by use of a side-to-side stapled technique. (1) The arms of a linear cutting stapler are inserted via transverse incisions at the anti-mesenteric sides of the terminal ileum and the transverse colon (tenia) and fired. (2) The enterotomy site is closed by removal of the specimen using a second transverse firing of the linear cutting stapler. An important final step is the (3) reinforcement of the anastomotic ends and the crossing of the staple lines; an omental patch and closure of the mesenteric window are optional. CONCLUSION: The suggested standardized five-step lateral-to-medial dissection of the right colon and the three-step side-to-side stapled technique for ileo-colonic anastomosis are easy to learn and to reproduce. Careful adherence to pivotal technical details will help to obtain an optimal oncological outcome and a consistently low leak rate around 2 %.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Freehand positioning of the femoral drill guide is difficult during hip resurfacing and the surgeon is often unsure of the implant position achieved peroperatively. The purpose of this study was to find out whether, by using a navigation system, acetabular and femoral component positioning could be made easier and more precise. Eighteen patients operated on by the same surgeon were matched by sex, age, BMI, diagnosis and ASA score (nine patients with computer assistance, nine with the regular ancillary). Pre-operative planning was done on standard AP and axial radiographs with CT scan views for the computer-assisted operations. The final position of implants was evaluated by the same radiographs for all patients. The follow-up was at least 1 year. No difference between both groups in terms of femoral component position was observed (p > 0.05). There was also no difference in femoral notching. A trend for a better cup position was observed for the navigated hips, especially for cup anteversion. There was no additional operating time for the navigated hips. Hip navigation for resurfacing surgery may allow improved visualisation and hip implant positioning, but its advantage probably will be more obvious with mini-incisions than with regular incision surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A consecutive series of 353 patients who underwent Lichtenstein mesh repair for inguinal hernia from the 1st of July 1994 to the 30th of July 1995 were studied. We analysed our indication, technique, complications, follow-up and outcome. Special consideration was given to the advantages and acceptance of day-case surgery. Our results suggest that the Lichtenstein repair should be considered as a new standard procedure, especially outside of hernia centres.