122 resultados para Coagulation tests
em Université de Lausanne, Switzerland
Resumo:
INTRODUCTION: Rivaroxaban (RXA) is licensed for prophylaxis of venous thromboembolism after major orthopaedic surgery of the lower limbs. Currently, no test to quantify RXA in plasma has been validated in an inter-laboratory setting. Our study had three aims: to assess i) the feasibility of RXA quantification with a commercial anti-FXa assay, ii) its accuracy and precision in an inter-laboratory setting, and iii) the influence of 10mg of RXA on routine coagulation tests. METHODS: The same chromogenic anti-FXa assay (Hyphen BioMed) was used in all participating laboratories. RXA calibrators and sets of blinded probes (aim ii.) were prepared in vitro by spiking normal plasma. The precise RXA content was assessed by high-pressure liquid chromatography-tandem mass spectrometry. For ex-vivo studies (aim iii), plasma samples from 20 healthy volunteers taken before and 2 - 3hours after ingestion of 10mg of RXA were analyzed by participating laboratories. RESULTS: RXA can be assayed chromogenically. Among the participating laboratories, the mean accuracy and the mean coefficient of variation for precision of RXA quantification were 7.0% and 8.8%, respectively. Mean RXA concentration was 114±43μg/L .RXA significantly altered prothrombin time, activated partial thromboplastin time, factor analysis for intrinsic and extrinsic factors. Determinations of thrombin time, fibrinogen, FXIII and D-Dimer levels were not affected. CONCLUSIONS: RXA plasma levels can be quantified accurately and precisely by a chromogenic anti-FXa assay on different coagulometers in different laboratories. Ingestion of 10mg RXA results in significant alterations of both PT- and aPTT-based coagulation assays.
Resumo:
BACKGROUND: While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when performing coagulation tests with identical analytical platforms in different laboratories and computed intraclass correlations coefficients (ICC) for each coagulation test. METHODS: Data from eight laboratories measuring fibrinogen twice in twenty healthy subjects with one out of 3 different platforms and single measurements of prothrombin time (PT), and coagulation factors II, V, VII, VIII, IX, X, XI and XIII were analysed. By platform, the variance components of (i) the subjects, (ii) the laboratory and the technician and (iii) the total variance were obtained for fibrinogen as well as (i) and (iii) for the remaining factors using ANOVA. RESULTS: The variability for fibrinogen measurements within a laboratory ranged from 0.02 to 0.04, the variability between laboratories ranged from 0.006 to 0.097. The ICC for fibrinogen ranged from 0.37 to 0.66 and from 0.19 to 0.80 for PT between the platforms. For the remaining factors the ICC's ranged from 0.04 (FII) to 0.93 (FVIII). CONCLUSIONS: Variance components that could be attributed to technicians or laboratory procedures were substantial, led to disappointingly low intraclass correlation coefficients for several factors and were pronounced for some of the platforms. Our findings call for sustained efforts to raise the level of standardization of structures and procedures involved in the quantification of coagulation factors.
The cost of inappropriateness of coagulation testing [I costi dell'inappropriatezza in coagulazione]
Resumo:
Background. Laboratory utilization has steadily increased with a corresponding increase in overall costs; several authors have attempted to measure the impact of inappropriateness on clinical outcomes but data are insufficient. The aim of the study is to assess the cost of inappropriateness of test-ordering behaviour for second-level coagulation tests (hemorrhagic diathesisand thrombophilia). Methods. We reviewed all second-level coagulation testrequests received by our department during a six months period. Clinicians must fill out a specific order form for these kind of tests, containing all informations deemed necessary for the laboratory specialist to evaluatethe appropriateness of the request. We identified all inappropriate requests and counted the numbers and types of all coagulation tests that were not performed during the period. An analysis of the laboratory activity costs was done in order to calculate the global costof each test in our department and to estimate the savings achieved. Results. On a total of 1664 second-level coagulationtest requests, we estimated 150 as completely inappropriate. We found an overall of 295 inappropriate testswhich were not performed. This resulted in an economic saving of 20.000 euro in 6 months. Conclusions. The analysis of cost of our intervention shows the urgent need for a definite and sustained reduction in inappropriate requests of second-level coagulation tests. Even though we estimated only the economic aspect of inappropriate testing, this is also associated with the overuse of diagnostic tests which entailsthe risk of generating erroneous results with potentialnegative consequences on patients' health.
Resumo:
Résumé Fondement : le développement de solutions d'hydroxy-éthyl-amidons (HEAS) avec peu d'impact sur la coagulation sanguine, mais un effet supérieur sur la volémie, par comparaison aux HEAS couramment utilisés, est d'un grand intérêt clinique. Nous posons l'hypothèse que des solutions de haut poids moléculaire et de bas degré de substitution possèdent ces caractéristiques. Méthode : trente porcs ont été perfusés avec trois HEAS différents (20 ml/kg) de même degré de substitution (0.42) mais de poids moléculaire différent (130, 500 et 900 kDa). Une série de prélèvements sanguins ont été effectués sur 24 heures, sur lesquels des analyses de coagulation sanguine étaient effectuées par thromboélastographie et dosages plasmatiques. De plus, la concentration plasmatique ainsi que le poids moléculaire in vivo ont été déterminés, ainsi que des paramètres de pharmacocinétiques, ceci en se basant sur un modèle bi-compartimental. Résultats : les analyses de thromboélastographie et les tests de coagulation plasmatique n'ont pas démontré d'altération plus marquée de la coagulation sanguine après l'utilisation des solutions des HAES 500 et HAES 900, par comparaison avec celle de HAES 130. Par contre, les HAES 500 et HAES 900 ont présenté une plus grande aire sous la courbe (area under the curve), dans la relation concentration en fonction du temps [1542 (142) g min litre-1, p<0.001, 1701 (321) g min litre-1, p<0.001] par rapport au HAES 130 [1156 (223) g min litre-1]. La demi-vie alpha (t ½α) était plus longue pour les HAES 500 [53.8 (8.6) min, p<0.01] et HAES 900 [57.1 (12.3) min, p<0.01 ]que pour le HAES 130 [39.9 (10.7) min]. La demi-vie beta (t½β) était par contre similaire pour les trois types de HAES [de 332 (100) à 381 (63) min]. Conclusions : pour les HAES de bas degré de substitution, le poids moléculaire n'est pas un facteur clé en ce qui concerne l'altération de la coagulation. La persistance intravasculaire initialement plus longue des HAES de haut poids moléculaire et bas degré de substitution pourrait résulter dans un plus long effet volémique de ces substances. Abstract Background: The development of hydroxyethyl starches (HES) with low impact on blood coagulation but higher volume effect compared with the currently used HES solutions is of clinical interest. We hypothesized that high molecular weight, low-substituted HES might possess these properties. Methods: Thirty pigs were infused with three different HES solutions (20 ml kg-1) with the same degree of molar substitution (0.42) but different molecular weights (130, 500 and 900 kDa). Serial blood samples were taken over 24 h and blood coagulation was assessed by Thromboelastograph® analysis and analysis of plasma coagulation. In addition, plasma concentration and in vivo molecular weight were determined and pharmacokinetic data were computed based on a two-compartment model. Results: Thromboelastograph analysis and plasma coagulation tests did not reveal a more pronounced alteration of blood coagulation with HES 500 and HES 900 compared with HES 130. In contrast, HES 500 and HES 900 had a greater area under the plasma concentration-time curve [1542 (142) g min litre-1, P<0.001, 1701 (321) g min litre-1, P<0.001] than HES 130 [I 156 (223) g min litre-1] and alpha half life (t ½α) was longer for HES 500 [53.8 (8.6) min, P<0.01 ] and HES 900 [57. I (I 2.3) min, P<0.01 ] than for HES 130 [39.9 (I 0.7) min]. Beta half life (t½β), however, was similar for all three types of HES [from 332 (100) to 381 (63) min]. Conclusions. In low-substituted HES, molecular weight is not a key factor in compromising blood coagulation. The longer initial intravascular persistence of high molecular weight lowsubstituted HES might result in a longer lasting volume effect.
Resumo:
The aim of this review article is to provide a clinical guideline for the child presenting with easy bruising, distinguishing among the different etiologic groups associated with this symptom what is normal and what is not, allowing then to establish an algorithm for work-up and follow-up. We also precise in which concrete situation it would be necessary to refer the child to a pediatric hematologist.
Resumo:
The authors evaluated ten years of surgical reanimation in the University Centre of Lausanne (CHUV). Irreversible coagulopathy (IC) is the predominant cause of death for the polytraumatized patient. Acidosis, hypothermy, and coagulation troubles are crucial elements of this coagulopathy. The authors looked for a criterion allowing the identification of dying of IC. In a retrospective study, laboratory results of pH, TP, PTT, thrombocyte count and the need for blood transfusion units were checked for each major step of the primary evaluation and treatment of the polytraumatized patients. These results were considered as critical according to criteria of the literature (30). The authors conclude that the apparation of a third critical value may be useful to identify the polytraumatized patient at risk of dying of IC status. This criterion may also guide the trauma team in selecting a damage control surgical approach (DCS). This criterion was then introduced into an algorithm involving the Emergency Department, the operating room and the Intensive Care Unit. This criterion is a new tool to address the patient at the crucial moment to the appropriate hospital structure.
Resumo:
Rapport de synthèse : Contexte: l'hydroxyéthylamidon (HEA) est largement utilisé comme expanseur volémique en anesthésiologie et réanimation. Cependant, cette classe de produits perturbe le system de la coagulation. Des améliorations restent possibles dans le choix de la combinaison optimale de poids moléculaire, de degré de substitution en radicaux éthyle et de localisation de ces radicaux sur le squelette glucidique des polymères, afin d'optimiser leur efficacité et leur tolérance. L'HEA de poids moléculaire élevé et faiblement substitué n'affecte pas plus la coagulation sanguine que de l'HEA de bas poids moléculaire faiblement substitué. Nous examinons in vivo l'effet d'un abaissement du rapport C2/C6 sur les caractéristiques pharmacocinétiques et l'impact sur la coagulation sanguine d'un HEA de haut poids moléculaire faiblement substitué. Matériels et méthode: nous comparons dans une étude prospective, randomisée et parallèle l'HEA 650/0.42/2.8 avec l'HEA 650/0.42/5.6 auprès de 30 cochons. Avant, pendant et jusqu'à 630 minutes après une perfusion de 30 ml/kg d'HEA, des échantillons sanguins ont été collectés pour mesurer les concentrations d'HEA, les tests de coagulation plasmatique classiques et la coagulation sanguine par thrombélastographie (TEG®, Haemoscope Corporation, Niles, II, U.S.). Les paramètres pharmacocinétiques ont été estimés en adaptant un modèle à deux compartiments. Résultats: la constante d'élimination est de 0.009 ± 0.001 (min-1) pour l'HEA 650/0.42/2.8 et 0.007 ± 0.001 (min-1) pour l'HEA 650/0.42/5.6 (p<0.001); la surface sous la courbe de concentration est de 1374 ± 340 min*g/L pour l'HEA 650/0.42/2.8 et 1697 ± 411 min*g/L pour l'HEA 650/0.42/5.6 (p=0.026). Les concentrations mesurées d'HEA ne montrent pas de différence entre l'HEA 650/0.42/2.8 et l'HEA 650/0.42/5.6. Les deux solutions d'HEA affectent de façon identique la coagulation sanguine: l'index de coagulation thrombélastographique diminue pareillement à ta fin de la perfusion d'HEA 650/0.42/2.8 et d'HEA 650/0.42/5.6 (p=0.29). De même, le temps de thromboplastine partielle activée et le temps de prothrombine augmentent de manière similaire pour l'HEA 650/0.42/2.8 et l'HEA 650/0.42/5.6 (p=0.83). Conclusion: la réduction du rapport C2/C6 de l'HEA de poids moléculaire élevé et faiblement substitué aboutit à une élimination légèrement accélérée d'HEA. Cependant, elle ne modifie pas l'effet perturbateur sur la coagulation.
Resumo:
Point-of-care (POC) tests offer potentially substantial benefits for the management of infectious diseases, mainly by shortening the time to result and by making the test available at the bedside or at remote care centres. Commercial POC tests are already widely available for the diagnosis of bacterial and viral infections and for parasitic diseases, including malaria. Infectious diseases specialists and clinical microbiologists should be aware of the indications and limitations of each rapid test, so that they can use them appropriately and correctly interpret their results. The clinical applications and performance of the most relevant and commonly used POC tests are reviewed. Some of these tests exhibit insufficient sensitivity, and should therefore be coupled to confirmatory tests when the results are negative (e.g. Streptococcus pyogenes rapid antigen detection test), whereas the results of others need to be confirmed when positive (e.g. malaria). New molecular-based tests exhibit better sensitivity and specificity than former immunochromatographic assays (e.g. Streptococcus agalactiae detection). In the coming years, further evolution of POC tests may lead to new diagnostic approaches, such as panel testing, targeting not just a single pathogen, but all possible agents suspected in a specific clinical setting. To reach this goal, the development of serology-based and/or molecular-based microarrays/multiplexed tests will be needed. The availability of modern technology and new microfluidic devices will provide clinical microbiologists with the opportunity to be back at the bedside, proposing a large variety of POC tests that will allow quicker diagnosis and improved patient care.
Resumo:
Introduction: Although the pig is a standard model for the evaluation of various diseases in humans, including coagulopathy, it is not clear whether results in animals can be extrapolated to man.Materials and methods: In 75 anesthetized pigs, we assessed reagent-supported thrombelastometry (ExTEM (R)), platelet-blocked thrombelastometry (FibTEM (R)), and aprotinin thrombelastometry (ApTEM (R)). Results were compared to values from 13 anesthetized humans.Results (median, 95% CI): ExTEM (R) : While clot strength was comparable in pigs (66 mm, 65-67 mm) and in humans (64 mm, 60-68 mm; NS), clotting time in animals was longer (pigs 64 s, 62-66 s; humans 55 s, 49-71 s; P<0.05) and clot formation time shorter (pigs 52 s, 49-54 s; humans 83 s, 67-98 s, P<0.001). The clot lysis index at 30 minutes was lower in animals (96.9%, 95.1-97.3%) than in humans (99.5%, 98.6-99.9%; P<0.001). ApTEM (R) showed no hyperfibrinolysis in animals. Modification of the anesthesia protocol in animals resulted in significant ExTEM (R) changes. FibTEM (R) : Complete platelet inhibition yielded significantly higher platelet contribution to clot strength in pigs (79%, 76-81%) than in humans (73%, 71-77%; P<0.05), whereas fibrinogen contribution to clot strength was higher in humans (27%, 24-29%) than in animals (21%, 19-24%; P<0.05).Conclusions: Maximum clot firmness is comparable in human and porcine blood. However, clot lysis, platelet and fibrinogen contribution to clot strength, as well as initiation and propagation of clotting, are considerably different between pigs and humans. In addition, anesthesic drugs seem to influence thrombelastometry in animals. Accordingly, coagulation abnormalities in pigs subjected to diseases may not necessarily represent the coagulation profile in sick patients. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
The recent roll-out of rapid diagnostic tests (RDTs) for malaria has highlighted the decreasing proportion of malaria-attributable illness in endemic areas. Unfortunately, once malaria is excluded, there are few accessible diagnostic tools to guide the management of severe febrile illnesses in low resource settings. This review summarizes the current state of RDT development for several key infections, including dengue fever, enteric fever, leptospirosis, brucellosis, visceral leishmaniasis and human African trypanosomiasis, and highlights many remaining gaps. Most RDTs for non-malarial tropical infections currently rely on the detection of host antibodies against a single infectious agent. The sensitivity and specificity of host-antibody detection tests are both inherently limited. Moreover, prolonged antibody responses to many infections preclude the use of most serological RDTs for monitoring response to treatment and/or for diagnosing relapse. Considering these limitations, there is a pressing need for sensitive pathogen-detection-based RDTs, as have been successfully developed for malaria and dengue. Ultimately, integration of RDTs into a validated syndromic approach to tropical fevers is urgently needed. Related research priorities are to define the evolving epidemiology of fever in the tropics, and to determine how combinations of RDTs could be best used to improve the management of severe and treatable infections requiring specific therapy.
Resumo:
Problématiques sur le plan éthique, mais aussi sur le plan juridique, les tests de dépistage des substances psychoactives en milieu scolaire et en milieu professionnel renvoient d'abord et avant tout à un examen d'aptitude. Celui-ci est du ressort de l'intervenant médical, sous couvert des garanties d'adéquation, de pertinence et de proportionnalité des moyens d'évaluation mis en oeuvre, ainsi que des règles relatives au consentement et à la confidentialité.
Resumo:
Forensic scientists working in 12 state or private laboratories participated in collaborative tests to improve the reliability of the presentation of DNA data at trial. These tests were motivated in response to the growing criticism of the power of DNA evidence. The experts' conclusions in the tests are presented and discussed in the context of the Bayesian approach to interpretation. The use of a Bayesian approach and subjective probabilities in trace evaluation permits, in an easy and intuitive manner, the integration into the decision procedure of any revision of the measure of uncertainty in the light of new information. Such an integration is especially useful with forensic evidence. Furthermore, we believe that this probabilistic model is a useful tool (a) to assist scientists in the assessment of the value of scientific evidence, (b) to help jurists in the interpretation of judicial facts and (c) to clarify the respective roles of scientists and of members of the court. Respondents to the survey were reluctant to apply this methodology in the assessment of DNA evidence.