9 resultados para Clinical performance

em Université de Lausanne, Switzerland


Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Intensification of pharmacotherapy in persons with poorly controlled chronic conditions has been proposed as a clinically meaningful process measure of quality. OBJECTIVE: To validate measures of treatment intensification by evaluating their associations with subsequent control in hypertension, hyperlipidemia, and diabetes mellitus across 35 medical facility populations in Kaiser Permanente, Northern California. DESIGN: Hierarchical analyses of associations of improvements in facility-level treatment intensification rates from 2001 to 2003 with patient-level risk factor levels at the end of 2003. PATIENTS: Members (515,072 and 626,130; age >20 years) with hypertension, hyperlipidemia, and/or diabetes mellitus in 2001 and 2003, respectively. MEASUREMENTS: Treatment intensification for each risk factor defined as an increase in number of drug classes prescribed, of dosage for at least 1 drug, or switching to a drug from another class within 3 months of observed poor risk factor control. RESULTS: Facility-level improvements in treatment intensification rates between 2001 and 2003 were strongly associated with greater likelihood of being in control at the end of 2003 (P < or = 0.05 for each risk factor) after adjustment for patient- and facility-level covariates. Compared with facility rankings based solely on control, addition of percentages of poorly controlled patients who received treatment intensification changed 2003 rankings substantially: 14%, 51%, and 29% of the facilities changed ranks by 5 or more positions for hypertension, hyperlipidemia, and diabetes, respectively. CONCLUSIONS: Treatment intensification is tightly linked to improved control. Thus, it deserves consideration as a process measure for motivating quality improvement and possibly for measuring clinical performance.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has recently been introduced in diagnostic microbiology laboratories for the identification of bacterial and yeast strains isolated from clinical samples. In the present study, we prospectively compared MALDI-TOF MS to the conventional phenotypic method for the identification of routine isolates. Colonies were analyzed by MALDI-TOF MS either by direct deposition on the target plate or after a formic acid-acetonitrile extraction step if no valid result was initially obtained. Among 1,371 isolates identified by conventional methods, 1,278 (93.2%) were putatively identified to the species level by MALDI-TOF MS and 73 (5.3%) were identified to the genus level, but no reliable identification was obtained for 20 (1.5%). Among the 1,278 isolates identified to the species level by MALDI-TOF MS, 63 (4.9%) discordant results were initially identified. Most discordant results (42/63) were due to systematic database-related taxonomical differences, 14 were explained by poor discrimination of the MALDI-TOF MS spectra obtained, and 7 were due to errors in the initial conventional identification. An extraction step was required to obtain a valid MALDI-TOF MS identification for 25.6% of the 1,278 valid isolates. In conclusion, our results show that MALDI-TOF MS is a fast and reliable technique which has the potential to replace conventional phenotypic identification for most bacterial strains routinely isolated in clinical microbiology laboratories.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Assays that measure a patient's immune response play an increasingly important role in the development of immunotherapies. The inherent complexity of these assays and independent protocol development between laboratories result in high data variability and poor reproducibility. Quality control through harmonization--based on integration of laboratory-specific protocols with standard operating procedures and assay performance benchmarks--is one way to overcome these limitations. Harmonization guidelines can be widely implemented to address assay performance variables. This process enables objective interpretation and comparison of data across clinical trial sites and also facilitates the identification of relevant immune biomarkers, guiding the development of new therapies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Smart canula concept allows for collapsed cannula insertion, and self-expansion within a vein of the body. (A) Computational fluid dynamics, and (B) bovine experiments (76+/-3.8 kg) were performed for comparative analyses, prior to (C) the first clinical application. For an 18F access, a given flow of 4 l/min (A) resulted in a pressure drop of 49 mmHg for smart cannula versus 140 mmHg for control. The corresponding Reynolds numbers are 680 versus 1170, respectively. (B) For an access of 28F, the maximal flow for smart cannula was 5.8+/-0.5 l/min versus 4.0+/-0.1 l/min for standard (P<0.0001), for 24F 5.5+/-0.6 l/min versus 3.2+/-0.4 l/min (P<0.0001), and for 20F 4.1+/-0.3 l/min versus 1.6+/-0.3 l/min (P<0.0001). The flow obtained with the smart cannula was 270+/-45% (20F), 172+/-26% (24F), and 134+/-13% (28F) of standard (one-way ANOVA, P=0.014). (C) First clinical application (1.42 m2) with a smart cannula showed 3.55 l/min (100% predicted) without additional fluids. All three assessment steps confirm the superior performance of the smart cannula design.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Emergency room reading performances have been a point of interest in recent studies comparing radiologists to other physician groups. Our objective was to evaluate and compare the reading performances of radiologists and surgeons in an emergency room setting of non-traumatic abdominal CTs. Methods and materials: A total of ten readers representing four groups participated in this study: three senior radiologists and visceral surgeons, respectively, and two junior radiologists and surgeons, respectively. Each observer blindedly evaluated a total of 150 multi-slice acute abdominal CTs. CTs were chosen representing established proportions of acute abdomen pathologies in a Level I trauma centre from 2003 to 2005. Each answer was interpretated as right or wrong regarding pathology location, diagnosis and need for operation. Gold standard was the intraoperative result, and the clinical patient follow-up for non-operated patients. Significance was assumed at a p <.05 level. Results: Senior radiologists had a mean score of 2.38 ± 1.14, junior radiologists a score of 2.34 ± 1.14, whereas senior surgeons scored 2.07 ± 1.30 and junior surgeons 1.62 ± 1.42. No significant difference was found between the two radiologist groups, but results were significantly better for senior surgeons as compared to junior surgeons and better for the two radiologist groups as compared to each of the surgeon groups (all p <.05). Conclusion: Abdominal CT reading in an acute abdomen setting should continue to rely on an evaluation by a radiologist, whether senior or junior. Satisfying reading results can be achieved by senior visceral surgeons, but junior surgeons need more experience for a good reading performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Point-of-care (POC) tests offer potentially substantial benefits for the management of infectious diseases, mainly by shortening the time to result and by making the test available at the bedside or at remote care centres. Commercial POC tests are already widely available for the diagnosis of bacterial and viral infections and for parasitic diseases, including malaria. Infectious diseases specialists and clinical microbiologists should be aware of the indications and limitations of each rapid test, so that they can use them appropriately and correctly interpret their results. The clinical applications and performance of the most relevant and commonly used POC tests are reviewed. Some of these tests exhibit insufficient sensitivity, and should therefore be coupled to confirmatory tests when the results are negative (e.g. Streptococcus pyogenes rapid antigen detection test), whereas the results of others need to be confirmed when positive (e.g. malaria). New molecular-based tests exhibit better sensitivity and specificity than former immunochromatographic assays (e.g. Streptococcus agalactiae detection). In the coming years, further evolution of POC tests may lead to new diagnostic approaches, such as panel testing, targeting not just a single pathogen, but all possible agents suspected in a specific clinical setting. To reach this goal, the development of serology-based and/or molecular-based microarrays/multiplexed tests will be needed. The availability of modern technology and new microfluidic devices will provide clinical microbiologists with the opportunity to be back at the bedside, proposing a large variety of POC tests that will allow quicker diagnosis and improved patient care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Because of its high prevalence, early screening for occupational asthma (OA) is crucial. We aimed to evaluate the screening performance of the Occupational Asthma Screening Questionnaire-11 items (OASQ-11) in a clinical setting. METHODS: Between January 2009 and December 2011, 169 workers referred for potential OA to our hospital completed the OASQ-11 and underwent workups to determine the final diagnosis. The discriminative abilities of the OASQ-11 as a whole and in relation to demographic and exposure parameters were determined by the area under the receiving operator characteristic curve (AUC). RESULTS: Model 1, consisting of the OASQ's items, showed fair discrimination (AUC, 0.69; 95% confidence interval, 0.58 to 0.80). Addition of age and exposure duration to model 1 improved discrimination (AUC, 0.80; confidence interval, 0.72 to 0.88). CONCLUSION: A simple model consisting of the OASQ-11's items, age, and exposure duration could well discriminate subjects with OA in a clinical setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The Geneva Prognostic Score (GPS), the Pulmonary Embolism Severity Index (PESI), and its simplified version (sPESI) are well known clinical prognostic scores for pulmonary embolism (PE).Objectives: To compare the prognostic performance of these scores in elderly patients with PE. Patients/Methods: In a multicenter Swiss cohort of elderly patients with venous thromboembolism, we prospectively studied 449 patients aged ≥65 years with symptomatic PE. The outcome was 30-day overall mortality. We dichotomized patients as low- vs. higher-risk in all three scores using the following thresholds: GPS scores ≤2 vs. >2, PESI risk classes I-II vs. III-V, and sPESI scores 0 vs. ≥1. We compared 30-day mortality in low- vs. higher-risk patients and the areas under the receiver operating characteristic curve (ROC). Results: Overall, 3.8% of patients (17/449) died within 30 days. The GPS classified a greater proportion of patients as low risk (92% [413/449]) than the PESI (36.3% [163/449]) and the sPESI (39.6% [178/449]) (P<0.001 for each comparison). Low-risk patients based on the sPESI had a mortality of 0% (95% confidence interval [CI] 0-2.1%) compared to 0.6% (95% CI 0-3.4%) for low-risk patients based on the PESI and 3.4% (95% CI 1.9-5.6%) for low-risk patients based on the GPS. The areas under the ROC curves were 0.77 (95%CI 0.72-0.81), 0.76 (95% CI 0.72-0.80), and 0.71 (95% CI 0.66-0.75), respectively (P=0.47). Conclusions: In this cohort of elderly patients with PE, the GPS identified a higher proportion of patients as low-risk but the PESI and sPESI were more accurate in predicting mortality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction : Décrire les patients d'une structure gériatrique offrant des hospitalisations de courte durée, dans un contexte ambulatoire, pour des situations gériatriques courantes dans le canton de Genève (Suisse). Mesurer les performances de cette structure en termes de qualité des soins et de coûts. Méthodes : Des données relatives au profil des 100 premiers patients ont été collectées (huit mois), ainsi qu'aux prestations, aux ressources et aux effets (réadmissions, décès, satisfaction, complications) de manière à mesurer différents indicateurs de qualité et de coûts. Les valeurs observées ont été systématiquement comparées aux valeurs attendues, calculées à partir du profil des patients. Résultats : Des critères d'admission ont été fixés pour exclure les situations dans lesquelles d'autres structures offrent des soins mieux adaptés. La spécificité de cette structure intermédiaire a été d'assurer une continuité des soins et d'organiser d'emblée le retour à domicile par des prestations de liaison ambulatoire. La faible occurrence des réadmissions potentiellement évitables, une bonne satisfaction des patients, l'absence de décès prématurés et le faible nombre de complications suggèrent que les soins médicaux et infirmiers ont été délivrés avec une bonne qualité. Le coût s'est révélé nettement plus économique que des séjours hospitaliers après ajustement pour la lourdeur des cas. Conclusion : L'expérience-pilote a démontré la faisabilité et l'utilité d'une unité d'hébergement et d'hospitalisation de court séjour en toute sécurité. Le suivi du patient par le médecin traitant assure une continuité des soins et évite la perte d'information lors des transitions ainsi que les examens non pertinents. INTRODUCTION: To describe patients admitted to a geriatric institution, providing short-term hospitalizations in the context of ambulatory care in the canton of Geneva. To measure the performances of this structure in terms of quality ofcare and costs. METHOD: Data related to the clinical,functioning and participation profiles of the first 100 patients were collected. Data related to effects (readmission, deaths, satisfaction, complications), services and resources were also documented over an 8-month period to measure various quality and costindicators. Observed values were systematically compared to expected values, adjusted for case mix. RESULTS: Explicit criteria were proposed to focus on the suitable patients, excluding situations in which other structures were considered to be more appropriate. The specificity of this intermediate structure was to immediately organize, upon discharge, outpatient services at home. The low rate of potentially avoidable readmissions, the high patient satisfaction scores, the absence of premature death and the low number of iatrogenic complications suggest that medical and nursing care delivered reflect a good quality of services. The cost was significantly lower than expected, after adjusting for case mix. CONCLUSION: The pilot experience showed that a short-stay hospitalization unit was feasible with acceptable security conditions. The attending physician's knowledge of the patients allowed this system tofocus on essential issues without proposing inappropriate services.