21 resultados para Chasse-galerie

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Idiopathic premature ventricular complexes originating from the ventricular outflow tract: evaluation, prognosis and management The prognosis of ventricular premature complexes (VPC) in the absence of heart disease is considered benign. VPC usually originate from the right or, less commonly, left ventricular outflow tract. QRS complexes therefore usually assume a left bundle branch block and inferior axis morphology. These VPC, particularly if very frequent (> 20,000 per day), may adversely affect left ventricular function and their suppression can restore normal function. Moreover, there is a clinical overlap with arrhythmogenic right ventricular dysplasia and this diagnosis should be considered when facing a left bundle branch block shaped VPC. However, the prognosis of outflow tract VPC is good for appropriately selected patients with normal left ventricular function, absence of syncope or ventricular tachycardia, and no evidence of cardiac disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cet article se veut une revue des effets ergogéniques et potentiellement délétères des principaux compléments alimentaires consommés par les sportifs populaires ou d'élite. De nombreux produits sont proposés sur le marché avec des allégations prometteuses, le plus souvent sans preuve scientifique sur leur validité ou leur innocuité. Les antioxydants n'augmentent ni la force ni l'endurance. La créatine améliore la capacité de récupération pour les exercices en intervalle anaérobie mais pas en course à pied ni en natation. L'hormone de croissance et les stéroïdes anabolisants augmentent la synthèse protéique et la masse maigre mais comportent des effets secondaires graves et souvent irréversibles. Les médecins, les diététiciens et les fédérations sportives ont un rôle important à jouer dans l'information et la prévention, afin d'éviter des attitudes néfastes pour la santé, pouvant même créer des addictions. This article reviews the evidence-based ergogenic potential adverse effects of the most common products in use by recreational and elite athletes today. This is an aggressively marketed and controversial area of sports medicine wordwide. It is therefore important for the scientific societies, clinicians, dieticians sports federations to be well versed in the more popular supplements and drugs in order to have an important role in information and prevention attitudes that can lead to health risks or addictions!

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le traité de sorcellerie connu sous le nom de Vauderye de Lyonois en brief n'a cessé d'intriguer les historiens. Sa description des agissements d'une secte de sorciers et de sorcières au service du diable le rattache indubitablement au puissant stéréotype du sabbat qui se construit dans la première moitié du XVe siècle. L'anonymat de son auteur, ainsi que la difficulté à établir les circonstances de sa rédaction, ont cependant contribué à reléguer ce texte énigmatique dans un angle mort de l'historiographie. À la lumière de nouvelles sources, le présent ouvrage entend restituer à la Vauderye de Lyonois toute son importance historique. Au-delà de l'édition critique, de la traduction et de l'analyse interne du texte, l'enquête offre un éclairage inédit sur les modalités d'émergence, de succès ou, a contrario, d'échec de la chasse aux sorcières dans la ville de Lyon, au temps de Charles VII. L'histoire retrouvée de la Vauderie de Lyon implique également une étude comparée des espaces frontaliers du royaume de France et de l'Empire (Dauphiné, Bourgogne, Savoie, Artois, Rhénanie) en fonction de leur sensibilité au péril sorcier. Se dessine ainsi un paysage politique où le nouveau mythe du sabbat, tout en se jouant apparemment des frontières, contribue aussi à mieux les définir.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

(Résumé de l'ouvrage) Durant toute l'Europe, et au-delà, on a assisté ces dernières années à un grand débat sur les sectes, leur nature, leur nombre, leur influence, leur rôle. Des événements tragiques comme les suicides collectifs ont confirmé dans leurs convictions ceux qui pensent que les sectes sont un fléau pour la société qui les tolère et pour les individus qui s'y engagent. D'autres, au contraire, mettent en garde contre la nouvelle « chasse aux sorcières » qu'on risque de déclencher et en appellent au respect du droit à la liberté religieuse. Ne faut-il pas compléter les analyses classiques de Max Weber et d'Ernst Troeltsch, qui distinguent entre le type « Église » et le type « Secte » ? Plusieurs études sur des groupes controversés (le tristement célèbre Ordre du Temple Solaire, les Témoins de Jéhovah, la Soka Gakkaï, les Loubavitch... ou les mouvances accusées de dérives sectaires) illustrent les évolutions contrastées du paysage religieux aujourd'hui. On assiste d'ailleurs à une mondialisation de ces phénomènes. Les auteurs reviennent longuement sur le débat de société autour des sectes, sur leur nocivité réelle ou supposée, sur leur stigmatisation légitime ou irraisonnée dans les médias et l'opinion publique. Les sectes interrogent la laïcité de l'État et le droit : entrent-elles dans le droit commun des religions ou faut-il créer une législation « anti-sectes » spécifiques ?

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction : Le syndrome de Brugada, décrit en 1992 par Pedro et Josep Brugada, est un syndrome cardiaque caractérisé par un sus-décalage particulier du segment ST associé à un bloc de branche droit atypique au niveau des dérivations ECG V1 à V3. Les altérations ECG du syndrome de Brugada sont classifiées en 3 types dont seul le type 1 est diagnostique. Les mécanismes physiopathologiques exacts de ce syndrome sont pour le moment encore controversés. Plusieurs hypothèses sont proposées dans la littérature dont deux principales retiennent l'attention : 1) le modèle du trouble de repolarisation stipule des potentiels d'action réduits en durée et en amplitude liés à un changement de répartition de canaux potassiques 2) le modèle du trouble de dépolarisation spécifie un retard de conduction se traduisant par une dépolarisation retardée. Dans le STEMI, un sus-décalage ST ressemblant à celui du syndrome de Brugada est expliqué par deux théories : 1) le courant de lésion diastolique suggère une élévation du potentiel diastolique transformé artificiellement en sus-décalage ST par les filtres utilisés dans tous les appareils ECG.¦Objectif : Recréer les manifestations ECG du syndrome de Brugada en appliquant les modifications du potentiel d'action des cardiomyocytes rapportées dans la littérature.¦Méthode : Pour ce travail, nous avons utilisé "ECGsim", un simulateur informatique réaliste d'ECG disponible gratuitement sur www.ecgsim.org. Ce programme est basé sur une reconstruction de l'ECG de surface à l'aide de 1500 noeuds représentant chacun les potentiels d'action des ventricules droit et gauche, épicardiques et endocardiques. L'ECG simulé peut être donc vu comme l'intégration de l'ensemble de ces potentiels d'action en tenant compte des propriétés de conductivité des tissus s'interposant entre les électrodes de surface et le coeur. Dans ce programme, nous avons définit trois zones, de taille différente, comprenant la chambre de chasse du ventricule droit. Pour chaque zone, nous avons reproduit les modifications des potentiels d'action citées dans les modèles du trouble de repolarisation et de dépolarisation et des théories de courant de lésion systolique et diastolique. Nous avons utilisé, en plus des douze dérivations habituelles, une électrode positionnée en V2IC3 (i.e. 3ème espace intercostal) sur le thorax virtuel du programme ECGsim.¦Résultats : Pour des raisons techniques, le modèle du trouble de repolarisation n'a pas pu être entièrement réalisée dans ce travail. Le modèle du trouble de dépolarisation ne reproduit pas d'altération de type Brugada mais un bloc de branche droit plus ou moins complet. Le courant de lésion diastolique permet d'obtenir un sus-décalage ST en augmentant le potentiel diastolique épicardique des cardiomyocytes de la chambre de chasse du ventricule droit. Une inversion de l'onde T apparaît lorsque la durée du potentiel d'action est prolongée. L'amplitude du sus-décalage ST dépend de la valeur du potentiel diastolique, de la taille de la lésion et de sa localisation épicardique ou transmurale. Le courant de lésion systolique n'entraîne pas de sus-décalage ST mais accentue l'amplitude de l'onde T.¦Discussion et conclusion : Dans ce travail, l'élévation du potentiel diastolique avec un prolongement de la durée du potentiel d'action est la combinaison qui reproduit le mieux les altérations ECG du Brugada. Une persistance de cellules de type nodal au niveau de la chambre de chasse du ventricule droit pourrait être une explication à ces modifications particulières du potentiel d'action. Le risque d'arythmie dans la Brugada pourrait également être expliqué par une automaticité anormale des cellules de type nodal. Ainsi, des altérations des mécanismes cellulaires impliqués dans le maintien du potentiel diastolique pourraient être présentes dans le syndrome de Brugada, ce qui, à notre connaissance, n'a jamais été rapporté dans la littérature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The increasing number of bomb attacks involving improvised explosive devices, as well as the nature of the explosives, give rise to concern among safety and law enforcement agencies. The substances used in explosive charges are often everyday products diverted from their primary licit applications. Thus, reducing or limiting their accessibility for prevention purposes is difficult. Ammonium nitrate, employed in agriculture as a fertiliser, is used worldwide in small and large homemade bombs. Black powder, dedicated to hunting and shooting sports, is used illegally as a filling in pipe bombs causing extensive damage. If the main developments of instrumental techniques in explosive analysis have been constantly pushing the limits of detection, their actual contribution to the investigation of explosives in terms of source discrimination is limited. Forensic science has seen the emergence of a new technology, isotope ratio mass spectrometry (IRMS), that shows promising results. Its very first application in forensic science dates back to 1979. Liu et al. analysed cannabis plants coming from different countries [Liu et al. 1979]. This preliminary study highlighted its potential to discriminate specimens coming from different sources. Thirty years later, the keen interest in this new technology has given rise to a flourishing number of publications in forensic science. The countless applications of IRMS to a wide range of materials and substances attest to its success and suggest that the technique is ready to be used in forensic science. However, many studies are characterised by a lack of methodology and fundamental data. They have been undertaken in a top-down approach, applying this technique in an exploratory manner on a restricted sampling. This manner of procedure often does not allow the researcher to answer a number of questions, such as: do the specimens come from the same source, what do we mean by source or what is the inherent variability of a substance? The production of positive results has prevailed at the expense of forensic fundamentals. This research focused on the evaluation of the contribution of the information provided by isotopic analysis to the investigation of explosives. More specifically, this evaluation was based on a sampling of black powders and ammonium nitrate fertilisers coming from known sources. Not only has the methodology developed in this work enabled us to highlight crucial elements inherent to the methods themselves, but also to evaluate both the longitudinal and transversal variabilities of the information. First, the study of the variability of the profile over time was undertaken. Secondly, the variability of black powders and ammonium nitrate fertilisers within the same source and between different sources was evaluated. The contribution of this information to the investigation of explosives was then evaluated and discussed. --------------------------------------------------------------------------------------------------- Le nombre croissant d'attentats à la bombe impliquant des engins explosifs artisanaux, ainsi que la nature des charges explosives, constituent une préoccupation majeure pour les autorités d'application de la loi et les organismes de sécurité. Les substances utilisées dans les charges explosives sont souvent des produits du quotidien, détournés de leurs applications licites. Par conséquent, réduire ou limiter l'accessibilité de ces produits dans un but de prévention est difficile. Le nitrate d'ammonium, employé dans l'agriculture comme engrais, est utilisé dans des petits et grands engins explosifs artisanaux. La poudre noire, initialement dédiée à la chasse et au tir sportif, est fréquemment utilisée comme charge explosive dans les pipe bombs, qui causent des dommages importants. Si les développements des techniques d'analyse des explosifs n'ont cessé de repousser les limites de détection, leur contribution réelle à l'investigation des explosifs est limitée en termes de discrimination de sources. Une nouvelle technologie qui donne des résultats prometteurs a fait son apparition en science forensique: la spectrométrie de masse à rapport isotopique (IRMS). Sa première application en science forensique remonte à 1979. Liu et al. ont analysé des plants de cannabis provenant de différents pays [Liu et al. 1979]. Cette étude préliminaire, basée sur quelques analyses, a mis en évidence le potentiel de l'IRMS à discriminer des spécimens provenant de sources différentes. Trente ans plus tard, l'intérêt marqué pour cette nouvelle technologie en science forensique se traduit par un nombre florissant de publications. Les innombrables applications de l'IRMS à une large gamme de matériaux et de substances attestent de son succès et suggèrent que la technique est prête à être utilisée en science forensique. Cependant, de nombreuses études sont caractérisées par un manque de méthodologie et de données fondamentales. Elles ont été menées sans définir les hypothèses de recherche et en appliquant cette technique de façon exploratoire sur un échantillonnage restreint. Cette manière de procéder ne permet souvent pas au chercheur de répondre à un certain nombre de questions, tels que: est-ce que deux spécimens proviennent de la même source, qu'entend-on par source ou encore quelle est l'intravariabilité d'une substance? La production de résultats positifs a prévalu au détriment des fondamentaux de science forensique. Cette recherche s'est attachée à évaluer la contribution réelle de l'information isotopique dans les investigations en matière d'explosifs. Plus particulièrement, cette évaluation s'est basée sur un échantillonnage constitué de poudres noires et d'engrais à base de nitrate d'ammonium provenant de sources connues. La méthodologie développée dans ce travail a permis non seulement de mettre en évidence des éléments cruciaux relatifs à la méthode d'analyse elle-même, mais également d'évaluer la variabilité de l'information isotopique d'un point de vue longitudinal et transversal. Dans un premier temps, l'évolution du profil en fonction du temps a été étudiée. Dans un second temps, la variabilité du profil des poudres noires et des engrais à base de nitrate d'ammonium au sein d'une même source et entre différentes sources a été évaluée. La contribution de cette information dans le cadre des investigations d'explosifs a ensuite été discutée et évaluée.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rapport de synthèse : Mesures de l'aorte ascendante par scanner synchronisé au rythme cardiaque: une étude pilote pour établir des valeurs normatives dans le cadre des futures thérapies par transcathéter. Objectif : L'objectif de cette étude est d'établir les valeurs morphométriques normatives de l'aorte ascendante à l'aide de l'angiographie par scanner synchronisé au rythme cardiaque, afin d'aider au développement des futurs traitements par transcathéter. Matériels et méthodes : Chez soixante-dix-sept patients (âgé de 22 à 83 ans, âge moyen: 54,7 ans), une angiographie par scanner synchronisé au rythme cardiaque a été réalisée pour évaluation des vaisseaux coronaires. Les examens ont été revus afin d'étudier l'anatomie de la chambre de chasse du ventricule gauche jusqu'au tronc brachio-céphalique droit. A l'aide de programmes de reconstructions multiplanaires et de segmentation automatique, différents diamètres et longueurs considérés comme importants pour les futurs traitements par transcathéter ont été mesurés. Les valeurs sont exprimées en moyennes, médianes, maximums, minimums, écart-types et en coefficients de variation. Les variations de diamètre de l'aorte ascendante durant le cycle cardiaque ont été aussi considérées. Résultats : Le diamètre moyen de la chambre de chasse du ventricule gauche était de 20.3+/-3.4 mm. Au niveau du sinus coronaire de l'aorte, il était de 34.2+/-4.1 mm et au niveau de la jonction sinotubulaire il était de 29.7+/-3.4 mm. Le diamètre moyen de l'aorte ascendante était de 32.7+/-3.8 mm. Le coefficient de variation de ces mesures variait de 12 à 17%. La distance moyenne entre l'insertion proximale des valvules aortiques et le départ du tronc brachio-céphalique droit était de 92.6+/-11.8 mm. La distance moyenne entre l'insertion proximale des valvules aortiques et l'origine de l'artère coronaire proximale était de 12.1+/-3.7 mm avec un coefficient de variation de 31%. La distance moyenne entre les deux ostia coronaires était de 7.2+/-3.1 mm avec un coefficient de variation de 43%. La longueur moyenne du petit arc de l'aorte ascendante entre l'artère coronaire gauche et le tronc brachio-céphalique droit était de 52.9+/-9.5 mm. La longueur moyenne de la continuité fibreuse entre la valve aortique et la valvule mitrale antérieure était de 14.6+/-3.3 mm avec un coefficient de variation de 23%. L'aire moyenne de la valve aortique était de 582.0+/-131.9 mm2. La variation du diamètre antéro-postérieur et transverse de l'aorte ascendante était respectivement de 8.4% et de 7.3%. Conclusion Il existe d'importantes variations inter-individuelles dans les mesures de l'aorte ascendante avec cependant des variations intra-individuelles faibles durant le cycle cardiaque. De ce fait, une approche personnalisée pour chaque patient est recommandée dans la confection des futures endoprothèses de l'aorte ascendante. Le scanner synchronisé au rythme cardiaque jouera un rôle prépondérant dans le bilan préthérapeutique. Abstract : The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3+/-3.4, coronary sinus 34.2+/-4.1, sinotubular junction 29.7+-3.4 and mid ascending aorta 32.7+/-3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6111.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1+/-3.7, and between both coronary ostia 7.2+/-3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 X9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.óf3.3, CV 13-43%. Mean aortic valve area was 582+-131.9 mm2. The variations of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rapport de synthèseObjectif: le remplacement valvulaire aortique par voie transcathétère est, actuellement, une méthode fiable indiquée pour des patients à haut risque porteurs d'une sténose valvulaire aortique. La voie transfémorale est utilisable seulement en cas d'absence de maladie vasculaire et la voie transapicale est contrindiquée en cas de dysfonction pulmonaire chronique sévère. Une alternative pour ne pas passer a travers l'espace pleural serait par voie sous- xiphoïdienne et trans-septale à travers le ventricule droit.Méthode: une expérience animale a été amené au laboratoire de recherche du CHUV. Cinq cochons (poids : 52.3±10.9 kg) ont été endormi et, sous anesthésie générale, le ventricule droit a été préparé a travers un accès sous- xiphoïdien. Ensuite, sous guide fluoroscopique et avec l'utilisation d'une échocardiographie intracardiaque, un accès trans-septal a été crée entre le ventricule droit et le ventricule gauche en utilisant des dilatateur de diamètre croissant (de 8F à 26F). Par la suite, une valve stentée crée dans le laboratoire en utilisant un stent en nitinol et du péricarde a été chargé dans une cartouche et introduite dans le ventricule gauche à travers un introducteur trans-septal. Enfin, la valve a été amené dans la chambre de chasse du ventricule gauche et ensuite dans la racine aortique et puis déployé au bon endroit. Quand le système a été retiré, le septum ventriculaire a pu être réparé par mise en place d'un système d'occlusion septal Amplazer. Trente minutes après la procédure, les animaux ont été sacrifié et le coeur a été analysé pour étudier le positionnement da la valve stentée, l'efficacité de la fermeture du septum inter-ventriculaire et la fermeture de la paroi du ventricule droit.Résultat : les cinq cochon ont tous eu un parfait positionnement et pose de la prothèse en position aortique au premier essai (efficacité 100%). Les procédures ont duré, moyennement, 49±4 minutes et la progressive dilatation de l'accès trans-septale à donné lieu à une communication inter-ventriculaire mesurable après dilatation avec du 18F et plus. Toutes les valves stentées ont été déployées au bon endroit avec un bon résultat du fonctionnement des valves prothétiques et absence d'insuffisance para prothétique. Pendant les procédures, des battement prématurés ainsi que des épisodes isolées de tachycardie supra ventriculaire ont été détectés. Par contre, il n'y a pas eu de bloc atrio-ventriculaire. Les pertes sanguines pendant les procédures étaient de 280±10mL, et les systèmes d'occlusion Amplatzer étaient tous bien déployés sans shunts inter-ventriculaires résiduels.Conclusion: la technique d'introduction de valve stentées par voie extrapleural (trans-ventriculaire et trans-septale) est techniquement possible et elle jette les bases pour le remplacement valvulaire aortique trans-ventriculaire sous anesthésie locale.