30 resultados para Cement materials
em Université de Lausanne, Switzerland
Resumo:
Biological materials are increasingly used in abdominal surgery for ventral, pelvic and perineal reconstructions, especially in contaminated fields. Future applications are multi-fold and include prevention and one-step closure of infected areas. This includes prevention of abdominal, parastomal and pelvic hernia, but could also include prevention of separation of multiple anastomoses, suture- or staple-lines. Further indications could be a containment of infected and/or inflammatory areas and protection of vital implants such as vascular grafts. Reinforcement patches of high-risk anastomoses or unresectable perforation sites are possibilities at least. Current applications are based mostly on case series and better data is urgently needed. Clinical benefits need to be assessed in prospective studies to provide reliable proof of efficacy with a sufficient follow-up. Only superior results compared with standard treatment will justify the higher costs of these materials. To date, the use of biological materials is not standard and applications should be limited to case-by-case decision.
Resumo:
Different embolic materials for portal vein embolization (PVE) were evaluated. Twenty pigs received left and median PVE. Hydrophilic phosphorylcholine, N-butyl cyanoacrylate, hydrophilic gel, and polyvinyl alcohol (PVA) particles measuring either 50-150 microm or 700-900 microm were used in five pigs each. Portography and portal vein pressure measurement were performed before, immediately after PVE, and before being euthanized at day 7. Tissue wedges from embolized, and non-embolized liver were obtained for pathology. After complete embolization, recanalization occurred at 7 days in one gel and one 700-900 PVA embolization. Post-PVE increase in portal pressure was found in all groups (p = 0.01). The area of the hepatic lobules in non-embolized liver was larger than in the embolized liver in all groups (p = 0.001). The ratios of the areas between non-embolized/embolized livers were 1.65, 2.19, 1.57, and 1.32 for gel, NBCA, 50-150 PVA and 700-900 PVA, respectively; the ratios of fibrosis between the embolized and non-embolized livers were 1.37, 3.01, 3.49, and 2.11 for gel, NBCA, 50-150 PVA and 700-900 PVA, respectively. Hepatic lobules in non-embolized liver were significantly larger with NBCA than in other groups (p = 0.01). Fibrosis in embolized liver was significantly higher for NBCA and 50-150 PVA (p = 0.002). The most severe changes in embolized and non-embolized liver were induced by 50-150 PVA and NCBA PVE.
Resumo:
The application of two approaches for high-throughput, high-resolution X-ray phase contrast tomographic imaging being used at the tomographic microscopy and coherent radiology experiments (TOMCAT) beamline of the SLS is discussed and illustrated. Differential phase contrast (DPC) imaging, using a grating interferometer and a phase-stepping technique, is integrated into the beamline environment at TOMCAT in terms of the fast acquisition and reconstruction of data and the availability to scan samples within an aqueous environment. A second phase contrast method is a modified transfer of intensity approach that can yield the 3D distribution of the decrement of the refractive index of a weakly absorbing object from a single tomographic dataset. The two methods are complementary to one another: the DPC method is characterised by a higher sensitivity and by moderate resolution with larger samples; the modified transfer of intensity approach is particularly suited for small specimens when high resolution (around 1 mu m) is required. Both are being applied to investigations in the biological and materials science fields.
Resumo:
In this paper, a phenomenologically motivated magneto-mechanically coupled finite strain elastic framework for simulating the curing process of polymers in the presence of a magnetic load is proposed. This approach is in line with previous works by Hossain and co-workers on finite strain curing modelling framework for the purely mechanical polymer curing (Hossain et al., 2009b). The proposed thermodynamically consistent approach is independent of any particular free energy function that may be used for the fully-cured magneto-sensitive polymer modelling, i.e. any phenomenological or micromechanical-inspired free energy can be inserted into the main modelling framework. For the fabrication of magneto-sensitive polymers, micron-size ferromagnetic particles are mixed with the liquid matrix material in the uncured stage. The particles align in a preferred direction with the application of a magnetic field during the curing process. The polymer curing process is a complex (visco) elastic process that transforms a fluid to a solid with time. Such transformation process is modelled by an appropriate constitutive relation which takes into account the temporal evolution of the material parameters appearing in a particular energy function. For demonstration in this work, a frequently used energy function is chosen, i.e. the classical Mooney-Rivlin free energy enhanced by coupling terms. Several representative numerical examples are demonstrated that prove the capability of our approach to correctly capture common features in polymers undergoing curing processes in the presence of a magneto-mechanical coupled load.
Resumo:
Several mechanisms have been postulated as potentially involved in life-threatening complications during cemented surgery. In this study, we evaluated the role of anaphylaxis and pulmonary fat embolism in the pathophysiology of bone cement implantation syndrome in a series of fatal cases that underwent medicolegal investigations. Postmortem findings in these cases were compared with those obtained from individuals who died after other injuries and/or interventions and in which activated mast cells and pulmonary fat embolism were involved in the pathogenesis of death. Fifty subjects were selected including 6 individuals who had undergone cemented total hip arthroplasty and died intraoperatively, 32 subjects who died shortly after being involved in traffic accidents, 8 individuals who died shortly after the injection of contrast material, and 4 subjects who had undergone orthopedic surgery and died postoperatively. Massive pulmonary fat embolism was determined to be the cause of death in all the 6 subjects who died intraoperatively as well as the main cause of death in traffic-road victims with rapid respiratory function deterioration. Mast cell activation was identified exclusively in the group of subjects who died shortly after contrast material administration. Massive pulmonary fat embolism appears to be the most important factor responsible for severe cardiorespiratory function deterioration during cemented arthroplasty. Cardiac comorbidities can also significantly influence the severity of intraoperative complications, thus corroborating the hypothesis of a multifactorial model in the pathogenesis of bone cement implantation syndrome.
Resumo:
Background: Local antibiotics may significantly improve the treatmentoutcome in bone infection without systemic toxicity. For impregnationof polymethylmethacrylate (PMMA), gentamicin, vancomycin and/orclindamycin are currently used. A new lipopeptid antibiotic,daptomycin, is a promising candidate for local treatment due to itsspectrum against staphylococci and enterococci (including multiresistantstrains), and concentration-dependent rapid bactericidalactivity. We investigated activity of antibiotic-loaded PMMA againstStaphylococcus epidermidis biofilms using an ultra-sensitive bacterialheat detection method (microcalorimetry).Methods: Staphylococcus epidermidis (strain RP62A, susceptibleto daptomycin, vancomycin and gentamicin) at concentration 106bacteria/ml was incubated with 2 g-PMMA block (Palacos, HeraeusMedical, Hanau, Germany) in 25 ml tryptic soy broth (TSB)supplemented with calcium. PMMA blocks were preloaded withdaptomycin, vancomycin and gentamicin each at 2 g/40 mg (= 100 mg/block) PMMA. After 72 h-incubation at 35 °C under static conditions,PMMA blocks were rinsed in phosphate-buffered solution (PBS) 5times and transferred in 4 ml-microcalorimetry ampoule filled with 1 mlTSB. Bacterial heat production, which is proportional to the quantityof biofilm on PMMA surface, was measured by isothermalmicrocalorimetry. The detection time was calculated as the time untilthe heat flow reached 20 microwatt.Results: Biomechanical properties did not differ between antibioticloadedand non-loaded PMMA blocks. The mean detection time (±standard deviation) of bacterial heat was 6.5 ± 0.4 h for PMMA withoutantibiotics (negative control), 13.5 ± 4.6 h for PMMA with daptomycin,14.0 ± 4.1 h for PMMA with vancomycin and 5.0 ± 0.4 h for PMMAwith gentamicin.Conclusion: Our data indicates that antibiotics at 2 g/40 mg PMMAdid not change the biomechanical properties of bone cement. Daptomycinand vancomycin were more active than gentamicin against S.epidermidis biofilms when all tested at 2 g/40 mg PMMA. In the nextstep, higher concentrations of daptomycin and their elution kineticneeds to be determined to optimize its antibiofilm activity before usingin the clinical setting.
Resumo:
Introduction: The use of bioabsorbable materials for orthopaedic useand traumatic fracture fixation in children has been poorly investigatedin the litterature and the effects on growing bones seem contradictory.The aim of the study is to compare the clinical and radiological resultsand evolution between bioabsorbable and traditional K-Wires for thetreatment of elbow epiphyseal fractures in children.Method: From jan. 2008 to Dec. 2009 21 children with similar fracturesand age were separated in two groups according to the way of fracturefixation: bioabsorbable K-Wire group and traditional K-Wire group.Follow-up was done at 3, 6 and 12 month post-operatively. Range ofmotion and elbow stability were measured for all patients. Theradiological evolution of the two groups were compared in term ofconsolidation, ossous resorption and radiolucencies. The clinicalresults were compared according to the Mayo Elbow Peformancescore. Controlateral elbow is compared with injured elbow in the twogroups.Results: In the bioabsorbable K-wire group, there were 10 children,including 5 girles and 5 boys with an average age of 9.5 years, rangingfrom 5 to 14 years. They were 7 external condylar fractures and3 epitrochlear fractures. In the traditional K-Wire group there were11 children, 2 girls and 9 boys with an average age of 7.6 years,ranging from 4 to 14 years. There were 10 external condylar fracturesand 1 epitrochlear fracture. At first follow up. The Mayo ElbowPerformance score was 93.8 (85-100 )for the bioabsorbable K-Wiregroup and 95.5 (85-100) for the traditional K-Wire group. In twochildren from the bioabsorbable K-Wire group there were transitoryradiolucencies along the wire tract on the x-ray, without clinicalmanifestation of it.We didn't see any premature closure of growingcartilage.Discussion: There is no significant differencies in term of clinical andradiological outcome between the two groups. The use ofbioabsorbable pins seems to be a good alternative to removabletraditional materials, avoiding a second operation.
Resumo:
The aim of this study was to compare clinical and radiological outcome of lateral condyle fracture of the elbow in children treated with bioabsorbable or metallic material. From January 2008 to December 2009, 16 children with similar fractures and ages were grouped according to the fixation material used. Children were seen at 3, 6, and 12 months and more than 4 years (mean 51.8 months) postoperatively. The clinical results were compared using the Mayo Elbow Performance Score (MEPS). Radiographic studies of the fractured and opposite elbow were assessed at last follow-up control. Twelve children had a sufficient followup and could be included in the study. Seven could be included in the traditional group and 5 in the bioabsorbable group. At 12 months, the MEPS was 100 for every child in both groups. Asymptomatic bony radiolucent visible tracks and heterotopic ossifications were noted in both groups. There were no significant differences in terms of clinical and radiological outcome between the two groups. The use of bioabsorbable pins or screws is a reasonable alternative to the traditional use of metallic materials for the treatment of lateral condyle fracture of the elbow in children.
Resumo:
INTRODUCTION: This is a single, level 1 trauma centre, prospective consecutive patient series with intramedullary infection in the presence of unstable tibial fracture treated using the Kirschner wire-reinforced, antibiotic cement nail. PATIENTS AND METHODS: A total of 10 consecutive patients (eight males and two females) with a mean age of 42 years (range, 20-59) suffering from infection after intramedullary nailing for tibial fracture, admitted during a period of 4 years, were included. An antibiotic cement-coated nail, handmade at the time of surgery, was implanted in all patients. This was followed by a standardised 6-week treatment protocol, extraction of the nail and definitive fixation. RESULTS: At 6 years of follow-up, infection eradication and bony union were possible in all of the patients. No further infection treatment was necessary; however, all of our patients underwent additional procedures (mean: four additional procedures per patient) for cosmetic or other non-infectious reasons (bone grafting, muscle flaps, etc.). CONCLUSIONS: The antibiotic cement-coated nail seems to be an effective treatment for intramedullary infections of the fractured tibia.
Resumo:
STATEMENT OF PROBLEM: Wear of methacrylate artificial teeth resulting in vertical loss is a problem for both dentists and patients. PURPOSE: The purpose of this study was to quantify wear of artificial teeth in vivo and to relate it to subject and tooth variables. MATERIAL AND METHODS: Twenty-eight subjects treated with complete dentures received 2 artificial tooth materials (polymethyl methacrylate (PMMA)/double-cross linked PMMA fillers; 35%/59% (SR Antaris DCL, SR Postaris DCL); experimental 48%/46%). At baseline and after 12 months, impressions of the dentures were poured with improved stone. After laser scanning, the casts were superimposed and matched. Maximal vertical loss (mm) and volumetric loss (mm(3)) were calculated for each tooth and log-transformed to reduce variability. Volumetric loss was related to the occlusally active surface area. Linear mixed models were used to study the influence of the factors jaw, tooth, and material on adjusted (residual) wear values (alpha=.05). RESULTS: Due to drop outs (n=5) and unmatchable casts (n=3), 69% of all teeth were analyzed. Volumetric loss had a strong linear relationship to surface area (P<.001); this was less pronounced for vertical loss (P=.004). The factor showing the highest influence was the subject. Wear was tooth dependent (increasing from incisors to molars). However, these differences diminished once the wear rates were adjusted for occlusal area, and only a few remained significant (anterior versus posterior maxillary teeth). Another influencing factor was the age of the subject. CONCLUSIONS: Clinical wear of artificial teeth is higher than previously measured or expected. The presented method of analyzing wear of artificial teeth using a laser-scanning device seemed suitable.
Resumo:
OBJECTIVES: (1) To evaluate the changes in surface roughness and gloss after simulated toothbrushing of 9 composite materials and 2 ceramic materials in relation to brushing time and load in vitro; (2) to assess the relationship between surface gloss and surface roughness. METHODS: Eight flat specimens of composite materials (microfilled: Adoro, Filtek Supreme, Heliomolar; microhybrid: Four Seasons, Tetric EvoCeram; hybrid: Compoglass F, Targis, Tetric Ceram; macrohybrid: Grandio), two ceramic materials (IPS d.SIGN and IPS Empress polished) were fabricated according to the manufacturer's instructions and optimally polished with up to 4000 grit SiC. The specimens were subjected to a toothbrushing (TB) simulation device (Willytec) with rotating movements, toothpaste slurry and at three different loads (100g/250g/350g). At hourly intervals from 1h to 10h TB, mean surface roughness Ra was measured with an optical sensor and the surface gloss (Gl) with a glossmeter. Statistical analysis was performed for log-transformed Ra data applying two-way ANOVA to evaluate the interaction between load and material and load and brushing time. RESULTS: There was a significant interaction between material and load as well as between load and brushing time (p<0.0001). The microhybrid and hybrid materials demonstrated more surface deterioration with higher loads, whereas with the microfilled resins Heliomolar and Adoro it was vice versa. For ceramic materials, no or little deterioration was observed over time and independent of the load. The ceramic materials and 3 of the composite materials (roughness) showed no further deterioration after 5h of toothbrushing. Mean surface gloss was the parameter which discriminated best between the materials, followed by mean surface roughness Ra. There was a strong correlation between surface gloss and surface roughness for all the materials except the ceramics. The evaluation of the deterioration curves of individual specimens revealed a more or less synchronous course suspecting hinting specific external conditions and not showing the true variability in relation to the tested material. SIGNIFICANCE: The surface roughness and gloss of dental materials changes with brushing time and load and thus results in different material rankings. Apart from Grandio, the hybrid composite resins were more prone to surface changes than microfilled composites. The deterioration potential of a composite material can be quickly assessed by measuring surface gloss. For this purpose, a brushing time of 10h (=72,000 strokes) is needed. In further comparative studies, specimens of different materials should be tested in one series to estimate the true variability.