297 resultados para CT colonography (virtual colonoscopy)

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to determine the impact of the learning curve on the diagnostic performances of CT colonography. Two blinded teams, each having a radiologist and gastroenterologist, prospectively examined 50 patients using helical CT scan followed by colonoscopy. Intermediate data evaluation was performed after 24 data sets (group 1) and compared with data from 26 subsequent patients (group 2). Parameters evaluated included sensitivity, specificity, false-positive and false-negative findings, time of data acquisition and interpretation. Using colonoscopy as the gold standard, sensitivity for CT colonography was for lesions >5 mm 63% for both teams for group 1 patients; for group 2 patients sensitivity was 45% for team 1 and 64% for team 2. Specificity per patients was for patient group 1 42% for team 1 and 58% for team 2; for patient group 2 it was 79% for both teams ( p=0.04 for team 1; p=0.2 for team 2). Comparing group 1 with group 2, the number of false-positive findings decreased significantly ( p=0.02). Furthermore, the mean time of data evaluation decreased from 45 to 17 min ( p=0.002) and the mean time of data acquisition from 19 to 17 min. With increasing experience, specificity and the time required for data interpretation improved and false positives decreased. There was no significant change of sensitivity, false-negative findings and time of data acquisition. A minimum experience of the readers is required for data interpretation of CT colonography.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: 1. To assess the diagnostic value of MDCT for acute colitis of various origin confirmed by colonoscopy and histology. 2. To evaluate the accuracy of MDCT of making the correct differential diagnosis. Methods and materials: The electronic hospital database from January 2006 to August 2008 revealed 351 patients with acute colitis of any origin wdetected by colonoscopy. In 85 out of these patients MDCT had been simultaneously performed (delay 3.1 days). Two radiologists jointly reviewed their corresponding CT features without knowledge of pathology and correlated them with the final histological diagnosis. Results: Eighty patients were finally included (46 women, mean age 63.4). Colitis was of ischemic (n = 35, 44%) or infectious (n = 15, 19%) origin. 18 patients (23%) had acute ulcerative colitis or Crohn's disease, in 10 patients (12%) another inflammatory cause and in two patients (2%) post radiation colitis was proven. MDCT was positive in 63 patients (78.9%). In 11 out of the 17 negative MDCT, the examination had been performed without large bowel distention. Ischemic colitis was responsible for 47.1% of the negative MDCT. Correct differential diagnosis was made in 32 (50.7%) out of the 63 positive MDCT. Among the different etiologies, the ischemic colitis was the most often misdiagnosed cause (n = 17, 58.6%). Conclusion: Large bowel distension is mandatory for reliable MDCT detection of acute colitis of any origin. Among the different aetiologies the ischemic cause is the most often associated with false negative MDCT findings and, in case of positive features, the most difficult to recognize as such.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Precise focusing is essential for transcranial MRI-guided focused ultrasound (TcMRgFUS) to minimize collateral damage to non-diseased tissues and to achieve temperatures capable of inducing coagulative necrosis at acceptable power deposition levels. CT is usually used for this refocusing but requires a separate study (CT) ahead of the TcMRgFUS procedure. The goal of this study was to determine whether MRI using an appropriate sequence would be a viable alternative to CT for planning ultrasound refocusing in TcMRgFUS. We tested three MRI pulse sequences (3D T1 weighted 3D volume interpolated breath hold examination (VIBE), proton density weighted 3D sampling perfection with applications optimized contrasts using different flip angle evolution and 3D true fast imaging with steady state precision T2-weighted imaging) on patients who have already had a CT scan performed. We made detailed measurements of the calvarial structure based on the MRI data and compared those so-called 'virtual CT' to detailed measurements of the calvarial structure based on the CT data, used as a reference standard. We then loaded both standard and virtual CT in a TcMRgFUS device and compared the calculated phase correction values, as well as the temperature elevation in a phantom. A series of Bland-Altman measurement agreement analyses showed T1 3D VIBE as the optimal MRI sequence, with respect to minimizing the measurement discrepancy between the MRI derived total skull thickness measurement and the CT derived total skull thickness measurement (mean measurement discrepancy: 0.025; 95% CL (-0.22-0.27); p = 0.825). The T1-weighted sequence was also optimal in estimating skull CT density and skull layer thickness. The mean difference between the phase shifts calculated with the standard CT and the virtual CT reconstructed from the T1 dataset was 0.08 ± 1.2 rad on patients and 0.1 ± 0.9 rad on phantom. Compared to the real CT, the MR-based correction showed a 1 °C drop on the maximum temperature elevation in the phantom (7% relative drop). Without any correction, the maximum temperature was down 6 °C (43% relative drop). We have developed an approach that allows for a reconstruction of a virtual CT dataset from MRI to perform phase correction in TcMRgFUS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Intensity-modulated radiotherapy (IMRT) credentialing for a EORTC study was performed using an anthropomorphic head phantom from the Radiological Physics Center (RPC; RPCPH). Institutions were retrospectively requested to irradiate their institutional phantom (INSTPH) using the same treatment plan in the framework of a Virtual Phantom Project (VPP) for IMRT credentialing. MATERIALS AND METHODS: CT data set of the institutional phantom and measured 2D dose matrices were requested from centers and sent to a dedicated secure EORTC uploader. Data from the RPCPH and INSTPH were thereafter centrally analyzed and inter-compared by the QA team using commercially available software (RIT; ver.5.2; Colorado Springs, USA). RESULTS: Eighteen institutions participated to the VPP. The measurements of 6 (33%) institutions could not be analyzed centrally. All other centers passed both the VPP and the RPC ±7%/4 mm credentialing criteria. At the 5%/5 mm gamma criteria (90% of pixels passing), 11(92%) as compared to 12 (100%) centers pass the credentialing process with RPCPH and INSTPH (p = 0.29), respectively. The corresponding pass rate for the 3%/3 mm gamma criteria (90% of pixels passing) was 2 (17%) and 9 (75%; p = 0.01), respectively. CONCLUSIONS: IMRT dosimetry gamma evaluations in a single plane for a H&N prospective trial using the INSTPH measurements showed agreement at the gamma index criteria of ±5%/5 mm (90% of pixels passing) for a small number of VPP measurements. Using more stringent, criteria, the RPCPH and INSTPH comparison showed disagreement. More data is warranted and urgently required within the framework of prospective studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In recent years, technological advances have allowed manufacturers to implement dual-energy computed tomography (DECT) on clinical scanners. With its unique ability to differentiate basis materials by their atomic number, DECT has opened new perspectives in imaging. DECT has been used successfully in musculoskeletal imaging with applications ranging from detection, characterization, and quantification of crystal and iron deposits; to simulation of noncalcium (improving the visualization of bone marrow lesions) or noniodine images. Furthermore, the data acquired with DECT can be postprocessed to generate monoenergetic images of varying kiloelectron volts, providing new methods for image contrast optimization as well as metal artifact reduction. The first part of this article reviews the basic principles and technical aspects of DECT including radiation dose considerations. The second part focuses on applications of DECT to musculoskeletal imaging including gout and other crystal-induced arthropathies, virtual noncalcium images for the study of bone marrow lesions, the study of collagenous structures, applications in computed tomography arthrography, as well as the detection of hemosiderin and metal particles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In recent years, technological advances have allowed manufacturers to implement dual-energy computed tomography (DECT) on clinical scanners. With its unique ability to differentiate basis materials by their atomic number, DECT has opened new perspectives in imaging. DECT has been successfully used in musculoskeletal imaging with applications ranging from detection, characterization, and quantification of crystal and iron deposits, to simulation of noncalcium (improving the visualization of bone marrow lesions) or noniodine images. Furthermore, the data acquired with DECT can be postprocessed to generate monoenergetic images of varying kiloelectron volts, providing new methods for image contrast optimization as well as metal artifact reduction. The first part of this article reviews the basic principles and technical aspects of DECT including radiation dose considerations. The second part focuses on applications of DECT to musculoskeletal imaging including gout and other crystal-induced arthropathies, virtual noncalcium images for the study of bone marrow lesions, the study of collagenous structures, applications in computed tomography arthrography, as well as the detection of hemosiderin and metal particles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 67-year-old woman was referred for staging of a mucosa-associated lymphoid tumor lymphoma involving the left conjunctiva. CT scan had shown paravertebral and pelvic masses, and a breast nodule. FDG PET/CT demonstrated moderately increased uptake in the left ocular conjunctiva and confirmed the paravertebral and pelvic masses and the breast nodule. Moreover, abnormal FDG uptake was shown in 2 breast nodules, the flank, the gluteus maximus, and the gastric cardia. The patient received 6 cycles of rituximab-bendamustine chemotherapy with a complete clinical and metabolic response at the 6-month follow-up PET/CT and remained relapse-free without visual acuity problem after a 36-month follow-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mouse has emerged as an animal model for many diseases. At IRO, we have used this animal to understand the development of many eye diseases and treatment of some of them. Precise evaluation of vision is a prerequisite for both these approaches. In this unit we describe three ways to measure vision: testing the optokinetic response, and evaluating the fundus by direct observation and by fluorescent angiography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to develop an easily applicable technique and a standardized protocol for high-quality post-mortem angiography. This protocol should (1) increase the radiological interpretation by decreasing artifacts due to the perfusion and by reaching a complete filling of the vascular system and (2) ease and standardize the execution of the examination. To this aim, 45 human corpses were investigated by post-mortem computed tomography (CT) angiography using different perfusion protocols, a modified heart-lung machine and a new contrast agent mixture, specifically developed for post-mortem investigations. The quality of the CT angiographies was evaluated radiologically by observing the filling of the vascular system and assessing the interpretability of the resulting images and by comparing radiological diagnoses to conventional autopsy conclusions. Post-mortem angiography yielded satisfactory results provided that the volumes of the injected contrast agent mixture were high enough to completely fill the vascular system. In order to avoid artifacts due to the post-mortem perfusion, a minimum of three angiographic phases and one native scan had to be performed. These findings were taken into account to develop a protocol for quality post-mortem CT angiography that minimizes the risk of radiological misinterpretation. The proposed protocol is easy applicable in a standardized way and yields high-quality radiologically interpretable visualization of the vascular system in post-mortem investigations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to compare the plaque morphology between coronary and peripheral arteries using intravascular ultrasound (IVUS). Methods: IVUS was performed in 68 patients with coronary and 93 with peripheral artery lesions (29 carotid, 50 renal, and 14 iliac). Plaques were classified as fibroatheroma (VH-FA) (further subclassified as thin-capped [VH-TCFA] and thick-capped [VH-ThCFA]), fibrocalcific plaque (VH-FC) and pathological intimal thickening (VH-PIT). Results: Plaque rupture (13% of coronary, 7% of carotid, 6% of renal, and 7% of iliac arteries; P=NS) and VH-TCFA (37% of coronary, 24% of carotid, 16% of renal, and 7% of iliac arteries; P=0.02) was observed in all arteries. Compared to coronary arteries, VH-FA was less frequently observed in renal (P<0.001) and iliac arteries (P<0.006), while VH-PIT and VH-FC were prevalent in both of these peripheral arteries. Lesions with positive remodeling demonstrated more characteristics of VH-FA in coronary, carotid, and renal arteries compared to those with intermediate/negative remodeling (all P<0.01). There was positive relationship between RI and percent necrotic core area in all four arteries. Conclusions: Atherosclerotic plaque phenotypes were heterogeneous among four different arteries. In contrast, the associations of remodeling mode with plaque phenotype and composition were similar among the various arterial beds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this educational poster is to introduce the technical principles of cerebral perfusion CT and to provide examples of its clinical applications and potential limitations in the everyday emergency practice. Methods and materials: Cerebral perfusion CT is a well established investigatory tool for many vascular and parenchymal brain dysfunctions. CT perfusion maps allow a semiquantitative assessment of cerebral perfusion. Results: Currently, cerebral perfusion CT has a pivotal role in differentiating reversible from irreversible ischemic parenchymal insult besides its integral role in grading vasospasm after subarachnoid hemorrhage. Furthermore, cerebral perfusion CT can be coupled to acetazolamide administration in order to assess the cerebrovascular reserve capacity before performing extra-/intra-cranial bypass surgery in patients with cerebral vascular insufficiency. Cerebral perfusion CT can also identify diffuse abnormalities of cerebral perfusion in children with traumatic brain injury showing a low initial GCS in order to predict the final outcome regarding the late occurrence of irreversible parenchymal damage. Cerebral Perfusion CT is also able to detect focal parenchymal perfusion abnormalities in acute epileptic seizures. Conclusion: Cerebral perfusion CT can be integrated in the management of many vascular, traumatic and functional disorders of the brain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Postmortem radiology had in recent years appeared in the field of forensic medicine and is now considered by some authors as a good replacement for conventional autopsy and by others as a complementary examination. Although postmortem CT radiological imaging is very useful in demonstrating traumatic lesions, its utility is still quite limited in the cardiovascular field. This limitation could be minimized by the introduction of postmortem angiography. At the University Center of Legal Medicine of Lausanne, CT scans and postmortem multiphase CTangiography are used in cases with a suspicion of ischemic heart disease.Method: The goal of this presentation is to demonstrate some correlations between postmortem CT, CTangiography and conventional autopsy examination in cases of ischemic heart disease.Results: We observed that the native CT scan can show only some pathological findings as cardiac tamponade and calcifications of coronary arteries. However, postmortem angiography allows a better visualization of coronary arteries and evaluation of stenosis and occlusion as well as better imaging of soft tissue.Conclusion: The interpretation of postmortem modern radiology is a new field for both forensic pathologists and radiologists who have to learn to read the postmortem modified images. The information obtained from both parties can help to further the understanding of CT and CT angiography in postmortem cases.