346 resultados para CORONARY VESSELS

em Université de Lausanne, Switzerland


Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: Contemporary free-breathing non contrast enhanced cardiovascular magnetic resonance angiography (CMRA) was qualitatively and quantitatively evaluated to ascertain the reproducibility of the method for coronary artery luminal dimension measurements. SUBJECTS AND METHODS: Twenty-two healthy volunteers (mean age 32 +/- 7 years, 12 males) without coronary artery disease were imaged at 2 centers (1 each in Europe and North America) using navigator-gated and corrected SSFP CMRA on a commercial whole body 1.5T System. Repeat images of right (RCA, n = 21), left anterior descending (LAD, n = 14) and left circumflex (LCX, n = 14) coronary arteries were obtained in separate sessions using identical scan protocol and imaging parameters. True visible vessel length, signal-to-noise (SNR), contrast-to-noise ratios (CNR) and the average luminal diameter over the first 4 cm of the vessel were measured. Intra-observer, inter-observer and inter-scan reproducibility of coronary artery luminal diameter were determined using Pearson's correlation, Bland-Altman analysis and intraclass correlation coefficients (ICC). RESULTS: CNR, SNR and the mean length of the RCA, LAD and LCX imaged for original and repeat scans were not significantly different (all p > 0.30). There was a high degree of intra-observer, inter-observer and inter-scan agreements for RCA, LAD and LCX luminal diameter respectively on Bland-Altman and ICC analysis (ICC's for RCA: 0.98. 0.98 and 0.86; LAD: 0.89, 0.89 and 0.63; LCX: 0.95, 0.94 and 0.79). CONCLUSION: In a 2-center study, we demonstrate that free-breathing 3D SSFP CMRA can visualize long continuous segments of coronary vessels with highly reproducible measurements of luminal diameter.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: To evaluate the feasibility of visualizing the stent lumen using coronary magnetic resonance angiography in vitro. MATERIAL AND METHODS: Nineteen different coronary stents were implanted in plastic tubes with an inner diameter of 3 mm. The tubes were positioned in a plastic container filled with gel and included in a closed flow circuit (constant flow 18 cm/sec). The magnetic resonance images were obtained with a dual inversion fast spin-echo sequence. For intraluminal stent imaging, subtraction images were calculated from scans with and without flow. Subsequently, intraluminal signal properties were objectively assessed and compared. RESULTS: As a function of the stent type, various degrees of in-stent signal attenuation were observed. Tantalum stents demonstrated minimal intraluminal signal attenuation. For nitinol stents, the stent lumen could be identified, but the intraluminal signal was markedly reduced. Steel stents resulted in the most pronounced intraluminal signal voids. CONCLUSIONS: With the present technique, radiofrequency penetration into the stents is strongly influenced by the stent material. Thesefindings may have important implicationsforfuture stent design and stent imaging strategies.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: Visualization of coronary blood flow by means of a slice-selective inversion pre-pulse in concert with bright-blood coronary MRA. MATERIALS AND METHODS: Coronary magnetic resonance angiography (MRA) of the right coronary artery (RCA) was performed in eight healthy adult subjects on a 1.5 Tesla MR system (Gyroscan ACS-NT, Philips Medical Systems, Best, NL) using a free-breathing navigator-gated and cardiac-triggered 3D steady-state free-precession (SSFP) sequence with radial k-space sampling. Imaging was performed with and without a slice-selective inversion pre-pulse, which was positioned along the main axis of the coronary artery but perpendicular to the imaging volume. Objective image quality parameters such as SNR, CNR, maximal visible vessel length, and vessel border definition were analyzed. RESULTS: In contrast to conventional bright-blood 3D coronary MRA, the selective inversion pre-pulse provided a direct measure of coronary blood flow. In addition, CNR between the RCA and right ventricular blood pool was increased and the vessels had a tendency towards better delineation. Blood SNR and CNR between right coronary blood and epicardial fat were comparable in both sequences. CONCLUSION: The combination of a free-breathing navigator-gated and cardiac-triggered 3D SSFP sequence with a slice-selective inversion pre-pulse allows for direct and directional visualization of coronary blood flow with the additional benefit of improved contrast between coronary and right ventricular blood pool.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: The goal of the present study was to develop a strategy for three-dimensional (3D) volume acquisition along the major axes of the coronary arteries. BACKGROUND: For high-resolution 3D free-breathing coronary magnetic resonance angiography (MRA), coverage of the coronary artery tree may be limited due to excessive measurement times associated with large volume acquisitions. Planning the 3D volume along the major axis of the coronary vessels may help to overcome such limitations. METHODS: Fifteen healthy adult volunteers and seven patients with X-ray angiographically confirmed coronary artery disease underwent free-breathing navigator-gated and corrected 3D coronary MRA. For an accurate volume targeting of the high resolution scans, a three-point planscan software tool was applied. RESULTS: The average length of contiguously visualized left main and left anterior descending coronary artery was 81.8 +/- 13.9 mm in the healthy volunteers and 76.2 +/- 16.5 mm in the patients (p = NS). For the right coronary artery, a total length of 111.7 +/- 27.7 mm was found in the healthy volunteers and 79.3 +/- 4.6 mm in the patients (p = NS). Comparing coronary MRA and X-ray angiography, a good agreement of anatomy and pathology was found in the patients. CONCLUSIONS: Double-oblique submillimeter free-breathing coronary MRA allows depiction of extensive parts of the native coronary arteries. The results obtained in patients suggest that the method has the potential to be applied in broader prospective multicenter studies where coronary MRA is compared with X-ray angiography.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: An animal study was carried out to compare long-term patency rates of coronary anastomoses performed with the GraftConnector versus running suture technique. METHODS: 10 sheep, 45 to 55 kg, underwent off-pump coronary artery bypass grafting (right internal mammary artery to left anterior descending artery). In 5 animals, the anastomosis was performed with a GraftConnector and in 5 animals with 7-0 running suture. Intraoperative fluoroscopy and a fluoroscopic control at 6 months were performed. After 6 months, the animals were sacrificed and the anastomoses were examined histologically. RESULTS: All animals survived at 6 months with 100% anastomosis patency rates in both groups. In the GraftConnector group, the anastomosis diameter at 6 months fluoroscopy was 118% of native left anterior descending artery versus 97% of the control group. Luminal anastomotic width at histology was 1.7 +/- 0.2 mm in the device group versus 1.6 +/- 0.1 mm in the control group. Mean intimal hyperplasia thickness was 0.21 +/- 0.1 mm in the device group versus 0.01 mm in the control group. CONCLUSIONS: The GraftConnector provides a consistent and reproducible coronary artery anastomosis and reduces technical demand and manual dexterity in coronary operations. Long-term results demonstrate that off-pump coronary artery bypass grafting performed with the GraftConnector had the same patency rate and luminal width as those performed with running suture.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Conventional coronary magnetic resonance angiography (MRA) techniques display the coronary blood-pool along with the surrounding structures, including the myocardium, the ventricular and atrial blood-pool, and the great vessels. This representation of the coronary lumen is not directly analogous to the information provided by x-ray coronary angiography, in which the coronary lumen displayed by iodinated contrast agent is seen. Analogous "luminographic" data may be obtained using MR arterial spin tagging (projection coronary MRA) techniques. Such an approach was implemented using a 2D selective "pencil" excitation for aortic spin tagging in concert with a 3D interleaved segmented spiral imaging sequence with free-breathing, and real-time navigator technology. This technique allows for selective 3D visualization of the coronary lumen blood-pool, while signal from the surrounding structures is suppressed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Coronary magnetic resonance imaging is a powerful non-invasive technique for the combined assessment of coronary artery anatomy and function. In the present review article, challenges in coronary artery imaging are discussed and results obtained in both healthy volunteers and patients with cardiovascular disease are presented. This includes a short overview of coronary artery vessel lumen and wall imaging, contrast agents, permeability of the coronary vessel wall, high-field imaging and imaging of endothelial function.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Positron emission tomography (PET) during the cold pressor test (CPT) has been used to assess endothelium-dependent coronary vasoreactivity, a surrogate marker of cardiovascular events. However, its use remains limited by cardiac PET availability. As multidetector computed tomography (MDCT) is more widely available, we aimed to develop a measurement of endothelium-dependent coronary vasoreactivity with MDCT and similar radiation burden as with PET. METHODS AND RESULTS: A study group of 18 participants without known cardiovascular risk factor (9F/9M; age 60±6 years) underwent cardiac PET with (82)Rb and unenhanced ECG-gated MDCT within 4h, each time at rest and during CPT. The relation between absolute myocardial blood flow (MBF) response to CPT by PET (ml·min(-1)·g(1)) and relative changes in MDCT-measured coronary artery surface were assessed using linear regression analysis and Spearman's correlation. MDCT and PET/CT were analyzed in all participants. Hemodynamic conditions during CPT at MDCT and PET were similar (P>0.3). Relative changes in coronary artery surface because of CPT (2.0-21.2%) correlated to changes in MBF (-0.10-0.52ml·min(-1)·g(1)) (ρ=0.68, P=0.02). Effective dose was 1.3±0.2mSv for MDCT and 3.1mSv for PET/CT. CONCLUSIONS: Assessment of endothelium-dependent coronary vasoreactivity using MDCT CPT appears feasible. Because of its wider availability, shorter examination time and similar radiation burden, MDCT could be attractive in clinical research for coronary status assessment.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Due to SNR constraints, current "bright-blood" 3D coronary MRA approaches still suffer from limited spatial resolution when compared to conventional x-ray coronary angiography. Recent 2D fast spin-echo black-blood techniques maximize signal for coronary MRA at no loss in image spatial resolution. This suggests that the extension of black-blood coronary MRA with a 3D imaging technique would allow for a further signal increase, which may be traded for an improved spatial resolution. Therefore, a dual-inversion 3D fast spin-echo imaging sequence and real-time navigator technology were combined for high-resolution free-breathing black-blood coronary MRA. In-plane image resolution below 400 microm was obtained. Magn Reson Med 45:206-211, 2001.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: To determine the relationship between carotid intima-media thickness (IMT), coronary artery calcification (CAC), and myocardial blood flow (MBF) at rest and during vasomotor stress in type 2 diabetes mellitus (DM). METHODS: In 68 individuals, carotid IMT was measured using high-resolution vascular ultrasound, while the presence of CAC was determined with electron beam tomography (EBT). Global and regional MBF was determined in milliliters per gram per minute with (13)N-ammonia and positron emission tomography (PET) at rest, during cold pressor testing (CPT), and during adenosine (ADO) stimulation. RESULTS: There was neither a relationship between carotid IMT and CAC (r = 0.10, p = 0.32) nor between carotid IMT and coronary circulatory function in response to CPT and during ADO (r = -0.18, p = 0.25 and r = 0.10, p = 0.54, respectively). In 33 individuals, EBT detected CAC with a mean Agatston-derived calcium score of 44 +/- 18. There was a significant difference in regional MBFs between territories with and without CAC at rest and during ADO-stimulated hyperemia (0.69 +/- 0.24 vs. 0.74 +/- 0.23 and 1.82 +/- 0.50 vs. 1.95 +/- 0.51 ml/g/min; p < or = 0.05, respectively) and also during CPT in DM but less pronounced (0.81 +/- 0.24 vs. 0.83 +/- 0.23 ml/g/min; p = ns). The increase in CAC was paralleled with a progressive regional decrease in resting as well as in CPT- and ADO-related MBFs (r = -0.36, p < or = 0.014; r = -0.46, p < or = 0.007; and r = -0.33, p < or = 0.041, respectively). CONCLUSIONS: The absence of any correlation between carotid IMT and coronary circulatory function in type 2 DM suggests different features and stages of early atherosclerosis in the peripheral and coronary circulation. PET-measured MBF heterogeneity at rest and during vasomotor stress may reflect downstream fluid dynamic effects of coronary artery disease (CAD)-related early structural alterations of the arterial wall.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Black-blood MR coronary vessel wall imaging may become a powerful tool for the quantitative and noninvasive assessment of atherosclerosis and positive arterial remodeling. Although dual-inversion recovery is currently the gold standard, optimal lumen-to-vessel wall contrast is sometimes difficult to obtain, and the time window available for imaging is limited due to competing requirements between blood signal nulling time and period of minimal myocardial motion. Further, atherosclerosis is a spatially heterogeneous disease, and imaging at multiple anatomic levels of the coronary circulation is mandatory. However, this requirement of enhanced volumetric coverage comes at the expense of scanning time. Phase-sensitive inversion recovery has shown to be very valuable for enhancing tissue-tissue contrast and for making inversion recovery imaging less sensitive to tissue signal nulling time. This work enables multislice black-blood coronary vessel wall imaging in a single breath hold by extending phase-sensitive inversion recovery to phase-sensitive dual-inversion recovery, by combining it with spiral imaging and yet relaxing constraints related to blood signal nulling time and period of minimal myocardial motion.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Coronary magnetic resonance angiography (MRA) is a powerful noninvasive technique with high soft-tissue contrast for the visualization of the coronary anatomy without X-ray exposure. Due to the small dimensions and tortuous nature of the coronary arteries, a high spatial resolution and sufficient volumetric coverage have to be obtained. However, this necessitates scanning times that are typically much longer than one cardiac cycle. By collecting image data during multiple RR intervals, one can successfully acquire coronary MR angiograms. However, constant cardiac contraction and relaxation, as well as respiratory motion, adversely affect image quality. Therefore, sophisticated motion-compensation strategies are needed. Furthermore, a high contrast between the coronary arteries and the surrounding tissue is mandatory. In the present article, challenges and solutions of coronary imaging are discussed, and results obtained in both healthy and diseased states are reviewed. This includes preliminary data obtained with state-of-the-art techniques such as steady-state free precession (SSFP), whole-heart imaging, intravascular contrast agents, coronary vessel wall imaging, and high-field imaging. Simultaneously, the utility of electron beam computed tomography (EBCT) and multidetector computed tomography (MDCT) for the visualization of the coronary arteries is discussed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: The goal was to test 2 hypotheses: first, that coronary endothelial function can be measured noninvasively and abnormal function detected using clinical 3.0-T magnetic resonance imaging (MRI); and second, that the extent of local coronary artery disease (CAD), in a given patient, is related to the degree of local abnormal coronary endothelial function. BACKGROUND: Abnormal endothelial function mediates the initiation and progression of atherosclerosis and predicts cardiovascular events. However, direct measures of coronary endothelial function have required invasive assessment. METHODS: The MRI was performed in 20 healthy adults and 17 patients with CAD. Cross-sectional coronary area and blood flow were quantified before and during isometric handgrip exercise, an endothelial-dependent stressor. In 10 severe, single-vessel CAD patients, paired endothelial function was measured in the artery with severe stenosis and the contralateral artery with minimal disease. RESULTS: In healthy adults, coronary arteries dilated and flow increased with stress. In CAD patients, coronary artery area and blood flow decreased with stress (both p </= 0.02). In the paired study, coronary artery area and blood flow failed to increase during exercise in the mildly diseased vessel, but both area (p = 0.01) and blood flow (p = 0.02) decreased significantly in the severely diseased, contralateral artery. CONCLUSIONS: Endothelial-dependent coronary artery dilation and increased blood flow in healthy subjects, and their absence in CAD patients, can now be directly visualized and quantified noninvasively. Local coronary endothelial function differs between severely and mildly diseased arteries in a given CAD patient. This novel, safe method may offer new insights regarding the importance of local coronary endothelial function and improved risk stratification in patients at risk for and with known CAD.