70 resultados para CO2 emission

em Université de Lausanne, Switzerland


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Dissection during laparoscopic surgery produces smoke containing potentially toxic substances. The aim of the present study was to analyze smoke samples produced during laparoscopic colon surgery using a bipolar vessel sealing device (LigaSuretrade mark). METHODS: Four consecutive patients undergoing left-sided colectomy were enrolled in this pilot study. Smoke was produced by the use of LigaSuretrade mark. Samples (5,5l) were evacuated from the pneumoperitoneum in a closed system into a reservoir. Analysis was performed with CO2-laser-based photoacoustic spectroscopy and confirmed by a Fourier-transform infrared spectrum. The detected spectra were compared to the available spectra of known toxins. RESULTS: Samples from four laparoscopic sigmoid resections were analyzed. No relevant differences were noted regarding patient and operation characteristics. The gas samples were stable over time proven by congruent control measurements as late as 24 h after sampling. The absorption spectra differed considerably between the patients. One broad absorption line at 100 ppm indicating H2O and several unknown molecules were detected. With a sensitivity of alpha min ca 10-5 cm-1 no known toxic substances like phenol or indole were identified. CONCLUSION: The use of a vessel sealing device during laparoscopic surgery does not produce known toxic substances in relevant quantity. Further studies are needed to identify unknown molecules and to analyze gas emission under various conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: Acetate brain metabolism has the particularity to occur specifically in glial cells. Labeling studies, using acetate labeled either with 13C (NMR) or 11C (PET), are governed by the same biochemical reactions and thus follow the same mathematical principles. In this study, the objective was to adapt an NMR acetate brain metabolism model to analyse [1-11C]acetate infusion in rats. Methods: Brain acetate infusion experiments were modeled using a two-compartment model approach used in NMR.1-3 The [1-11C]acetate labeling study was done using a beta scintillator.4 The measured radioactive signal represents the time evolution of the sum of all labeled metabolites in the brain. Using a coincidence counter in parallel, an arterial input curve was measured. The 11C at position C-1 of acetate is metabolized in the first turn of the TCA cycle to the position 5 of glutamate (Figure 1A). Through the neurotransmission process, it is further transported to the position 5 of glutamine and the position 5 of neuronal glutamate. After the second turn of the TCA cycle, tracer from [1-11C]acetate (and also a part from glial [5-11C]glutamate) is transferred to glial [1-11C]glutamate and further to [1-11C]glutamine and neuronal glutamate through the neurotransmission cycle. Brain poster session: oxidative mechanisms S460 Journal of Cerebral Blood Flow & Metabolism (2009) 29, S455-S466 Results: The standard acetate two-pool PET model describes the system by a plasma pool and a tissue pool linked by rate constants. Experimental data are not fully described with only one tissue compartment (Figure 1B). The modified NMR model was fitted successfully to tissue time-activity curves from 6 single animals, by varying the glial mitochondrial fluxes and the neurotransmission flux Vnt. A glial composite rate constant Kgtg=Vgtg/[Ace]plasma was extracted. Considering an average acetate concentration in plasma of 1 mmol/g5 and the negligible additional amount injected, we found an average Vgtg = 0.08±0.02 (n = 6), in agreement with previous NMR measurements.1 The tissue time-activity curve is dominated by glial glutamate and later by glutamine (Figure 1B). Labeling of neuronal pools has a low influence, at least for the 20 mins of beta-probe acquisition. Based on the high diffusivity of CO2 across the blood-brain barrier; 11CO2 is not predominant in the total tissue curve, even if the brain CO2 pool is big compared with other metabolites, due to its strong dilution through unlabeled CO2 from neuronal metabolism and diffusion from plasma. Conclusion: The two-compartment model presented here is also able to fit data of positron emission experiments and to extract specific glial metabolic fluxes. 11C-labeled acetate presents an alternative for faster measurements of glial oxidative metabolism compared to NMR, potentially applicable to human PET imaging. However, to quantify the relative value of the TCA cycle flux compared to the transmitochondrial flux, the chemical sensitivity of NMR is required. PET and NMR are thus complementary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

C4 photosynthesis is an adaptation derived from the more common C3 photosynthetic pathway that confers a higher productivity under warm temperature and low atmospheric CO2 concentration [1, 2]. C4 evolution has been seen as a consequence of past atmospheric CO2 decline, such as the abrupt CO2 fall 32-25 million years ago (Mya) [3-6]. This relationship has never been tested rigorously, mainly because of a lack of accurate estimates of divergence times for the different C4 lineages [3]. In this study, we inferred a large phylogenetic tree for the grass family and estimated, through Bayesian molecular dating, the ages of the 17 to 18 independent grass C4 lineages. The first transition from C3 to C4 photosynthesis occurred in the Chloridoideae subfamily, 32.0-25.0 Mya. The link between CO2 decrease and transition to C4 photosynthesis was tested by a novel maximum likelihood approach. We showed that the model incorporating the atmospheric CO2 levels was significantly better than the null model, supporting the importance of CO2 decline on C4 photosynthesis evolvability. This finding is relevant for understanding the origin of C4 photosynthesis in grasses, which is one of the most successful ecological and evolutionary innovations in plant history.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a case of experimentally induced pre-syncope in a healthy young man when exposed to increased inspired CO2 in a background of hypoxia. Acute severe hypoxia (FIO2=0.10) was tolerated, but adding CO2 to the inspirate caused pre-syncope symptoms accompanied by hypotension and large reductions in both mean and diastolic middle cerebral artery velocity, while systolic flow velocity was maintained. The mismatch of cerebral perfusion pressure and vascular tone caused unique retrograde cerebral blood flow at the end of systole and a reduction in cerebral tissue oxygenation. We speculate that this occurrence of pre-syncope was due to hypoxia-induced inhibition of brain regions responsible for compensatory sympathetic activity to relative hypercapnia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the failure pattern observed after (18)F fluoroethyltyrosine (FET) planning after chemo- and radiotherapy (RT) for high-grade glioma. METHODS: All patients underwent prospectively RT planning using morphological gross tumour volumes (GTVs) and biological tumour volumes (BTVs). The post-treatment recurrence tumour volumes (RTVs) of 10 patients were transferred on their CT planning. First, failure patterns were defined in terms of percentage of RTV located outside the GTV and BTV. Second, the location of the RTV with respect to the delivered dose distribution was assessed using the RTV's DVHs. Recurrences with >95% of their volume within 95% isodose line were considered as central recurrences. Finally, the relationship between survival and GTV/BTV mismatches was assessed. RESULTS: The median percentages of RTV outside the GTV and BTV were 41.8% (range, 10.5-92.4) and 62.8% (range, 34.2-81.1), respectively. The majority of recurrences (90%) were centrally located. Using a composite target volume planning formalism, the degree of GTV and BTV mismatch did not correlate with survivorship. CONCLUSIONS: The observed failure pattern after FET-PET planning and chemo-RT is primarily central. The target mismatch-survival data suggest that using FET-PET planning may counteract the possibility of BTV-related progression, which may have a detrimental effect on survival.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Positron emission tomography (PET) during the cold pressor test (CPT) has been used to assess endothelium-dependent coronary vasoreactivity, a surrogate marker of cardiovascular events. However, its use remains limited by cardiac PET availability. As multidetector computed tomography (MDCT) is more widely available, we aimed to develop a measurement of endothelium-dependent coronary vasoreactivity with MDCT and similar radiation burden as with PET. METHODS AND RESULTS: A study group of 18 participants without known cardiovascular risk factor (9F/9M; age 60±6 years) underwent cardiac PET with (82)Rb and unenhanced ECG-gated MDCT within 4h, each time at rest and during CPT. The relation between absolute myocardial blood flow (MBF) response to CPT by PET (ml·min(-1)·g(1)) and relative changes in MDCT-measured coronary artery surface were assessed using linear regression analysis and Spearman's correlation. MDCT and PET/CT were analyzed in all participants. Hemodynamic conditions during CPT at MDCT and PET were similar (P>0.3). Relative changes in coronary artery surface because of CPT (2.0-21.2%) correlated to changes in MBF (-0.10-0.52ml·min(-1)·g(1)) (ρ=0.68, P=0.02). Effective dose was 1.3±0.2mSv for MDCT and 3.1mSv for PET/CT. CONCLUSIONS: Assessment of endothelium-dependent coronary vasoreactivity using MDCT CPT appears feasible. Because of its wider availability, shorter examination time and similar radiation burden, MDCT could be attractive in clinical research for coronary status assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photons participate in many atomic and molecular interactions and processes. Recent biophysical research has discovered an ultraweak radiation in biological tissues. It is now recognized that plants, animal and human cells emit this very weak biophotonic emission which can be readily measured with a sensitive photomultiplier system. UVA laser induced biophotonic emission of cultured cells was used in this report with the intention to detect biophysical changes between young and adult fibroblasts as well as between fibroblasts and keratinocytes. With suspension densities ranging from 1-8 x 106 cells/ml, it was evident that an increase of the UVA-laser-light induced photon emission intensity could be observed in young as well as adult fibroblastic cells. By the use of this method to determine ultraweak light emission, photons in cell suspensions in low volumes (100 microl) could be detected, in contrast to previous procedures using quantities up to 10 ml. Moreover, the analysis has been further refined by turning off the photomultiplier system electronically during irradiation leading to the first measurements of induced light emission in the cells after less than 10 micros instead of more than 100 milliseconds. These significant changes lead to an improvement factor up to 106 in comparison to classical detection procedures. In addition, different skin cells as fibroblasts and keratinocytes stemming from the same donor were measured using this new highly sensitive method in order to find new biophysical insight of light pathways. This is important in view to develop new strategies in biophotonics especially for use in alternative therapies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Keywords Diabetes mellitus; coronary artery disease; myocardial ischemia; prognostic value; single-photon emission computed tomography myocardial perfusion imaging Summary Aim: To determine the long-term prognostic value of SPECT myocardial perfusion imaging (MPI) for the occurrence of cardiovascular events in diabetic patients. Methods: SPECT MPI of 210 consecutive Caucasian diabetic patients were analysed using Kaplan-Meier event-free survival curves and independent predictors were determined by Cox multivariate analyses. Results: Follow-up was complete in 200 (95%) patients with a median period of 3.0 years (0.8-5.0). The population was composed of 114 (57%) men, age 65±10 years, 181 (90.5%) type 2 diabetes mellitus, 50 (25%) with a history of coronary artery disease (CAD) and 98 (49%) presenting chest pain prior to MPI. The prevalence of abnormal MPI was 58%. Patients with a normal MPI had neither cardiac death, nor myocardial infarction, independently of a history of coronary artery disease or chest pain. Among the independent predictors of cardiac death and myocardial infarction, the strongest was abnormal MPI (p<.0001), followed by history of CAD (Hazard Ratio (HR)= t 5.9, p=0.0001), diabetic retinopathy (HR=10.0, p=0.001) and inability to exercise (HR=7.7, p=0.02). Patients with normal 1VIPI had a low revascularisation rate of 2.4% during the follow-up period. Compared to normal MPI, cardiovascular events increased 5.2 fold for reversible defects, 8.5 fold for fixed defects and 20.1 fold for the association of both defects. Conclusion: Diabetic patients with normal MPI had an excellent prognosis independently of history of CAD. On the opposite, an abnormal MPI led to a > 5 fold increase in cardiovascular events. This emphasizes the value of SPECT MPI in predicting and risk-stratifying cardiovascular events in diabetic patients. Mots-Clés Diabète; maladie coronarienne; ischémie myocardique; valeur pronostique; tomoscintigraphie myocardique de perfusion par émission monophotonique Résumé Objectifs: Déterminer la valeur pronostique à long terme de la tomoscintigraphie myocardique de perfusion (TSMP) chez les patients diabétiques pour prédire les événements cardiovasculaires (ECV). Méthodes: Etude de 210 diabétiques caucasiens consécutifs référés pour une TSMP. Les courbes de survie ont été déterminées par Kaplan-Meier et les facteurs prédictifs indépendants par analyses multivariées de type Cox. Résultats: Le suivi a été complet chez 200 (95%) patients avec une durée médiane de 3.0 ans (0.8-50). La population était composée de 114 (57%) hommes, âge moyen 65±10 ans, avec 181 (90.5%) diabète de type 2, 50 (25%) antécédents de maladie coronarienne (AMC) et 98 (49%) patients connus pour un angor avant la TSMP. La prévalence de TSMP anormales était de 58%. Aucun décès d'origine cardiaque ou infarctus du myocarde n'est survenu chez les patients avec une TSMP normale, ceci indépendamment de leurs AMC et des douleurs thoraciques. Les facteurs prédictifs indépendants pour les ECV sont une TSMP anormale (p<.0001), les AMC (Hazard Ratio (HR)=15.9, p-0.0001), suivi de la rétinopathie diabétique (HR-10.0, p=0.001) et de l'incapacité à effectuer un exercice (HR=7.7, p=0.02). Les patients avec une TSMP normale ont présenté un taux de revascularisations de 2.4%. La présence de défauts mixtes accroît le risque d'ECV de 20.1 fois, les défauts fixes de 8.5 fois et les défauts réversibles de 5.2 fois comparés aux sujets avec une TSMP normale. Conclusion: Les patients diabétiques, coronariens ou non, avec une tomoscintigraphie myocardique de perfusion normale ont un excellent pronostique. A l'opposé, une TSMP anormale est associée à une augmentation du risque d'ECV de plus de 5 fois. Ceci confirme l'utilité de la TSMP dans la stratification du risque chez les patients diabétiques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare MDCT, MRI and 18F-FDG PET/CT for the detection of peritoneal carcinomatosis due to ovarian cancerMethods and Materials: Fifteen women (mean age 65±) with clinical suspicion of ovarian cancer and peritoneal carcinomatosis underwent MDCT, MRI and 18F-FDG PET/CT, simultaneously and shortly performed before surgery (delay 8.1± days). According to the peritoneal cancer index nine abdominopelvic regions were defined. We applied four scores of lesion size on MDCT and MR images, while the maximal standard uptake value (SUVmax) was measured on 18F-FDG PET/CT. Three sites of lymphadenopathy and posterobasal pleural carcinomatosis were also analyzed. First, one radiologist blindly and separately read MDCT and MR images, while one nuclear physician blindly read PET/CT images grading each lesion according to four diagnostic certitudes. Secondly, all the images were reviewed jointly and compared with histopathology. Receiver operating characteristics (ROC) analysis was performed.Results: Peritoneal implants were proven in ten women (75%). Altogether, 228 abdominopelvic sites were compared. Sensitivity and specificity for MDCT was 90.2% and 90.6%, for MRI 93.5% and 86.3%, and for 18F-FDG PET/CT 92.7% and 95.7%, respectively. ROC area under the curve were 0.93 for MDCT and MRI, and 0.96 for 18F-FDG PET/CT respectively. No significant differences (p=0.11) were found between the three modalities.Conclusion: Although MRI revealed to be the most sensitive and 18F-FDG PET/CT the most specific modality, no significant differences were shown between the three techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been demonstrated in earlier studies that patients with a cochlear implant have increased abilities for audio-visual integration because the crude information transmitted by the cochlear implant requires the persistent use of the complementary speech information from the visual channel. The brain network for these abilities needs to be clarified. We used an independent components analysis (ICA) of the activation (H2 (15) O) positron emission tomography data to explore occipito-temporal brain activity in post-lingually deaf patients with unilaterally implanted cochlear implants at several months post-implantation (T1), shortly after implantation (T0) and in normal hearing controls. In between-group analysis, patients at T1 had greater blood flow in the left middle temporal cortex as compared with T0 and normal hearing controls. In within-group analysis, patients at T0 had a task-related ICA component in the visual cortex, and patients at T1 had one task-related ICA component in the left middle temporal cortex and the other in the visual cortex. The time courses of temporal and visual activities during the positron emission tomography examination at T1 were highly correlated, meaning that synchronized integrative activity occurred. The greater involvement of the visual cortex and its close coupling with the temporal cortex at T1 confirm the importance of audio-visual integration in more experienced cochlear implant subjects at the cortical level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Positron emission tomography is a functional imaging technique that allows the detection of the regional metabolic rate, and is often coupled with other morphological imaging technique such as computed tomography. The rationale for its use is based on the clearly demonstrated fact that functional changes in tumor processes happen before morphological changes. Its introduction to the clinical practice added a new dimension in conventional imaging techniques. This review presents the current and proposed indications of the use of positron emission/computed tomography for prostate, bladder and testes, and the potential role of this exam in radiotherapy planning.