178 resultados para Blood sugar self monitoring

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is a sustained controversy in the literature about the role and utility of self-monitoring of blood glucose (SMBG) in type 2 diabetes. The study results in this field do not provide really useful clues for the integration of SMBG in the follow-up of the individual patient, because they are based on a misconception of SMBG. It is studied as if it was a medical treatment whose effect on glycemic control is to be isolated. However, SMBG has no such intrinsic effect. It gains its purpose only as an inseparable component of a comprehensive and structured educational strategy. To be appropriate this strategy cannot be based on the health care professionals' view on diabetes only. It rather has to be tailored to the individual patient's needs through an ongoing process of shared reflection with him.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Pre-existing psychological factors can strongly influence coping with type 1 diabetes mellitus and interfere with self-monitoring. Psychiatric disorders seem to be positively associated with poor metabolic control. We present a case of extreme compulsive blood testing due to obsessive fear of hypoglycemia in an adolescent with type 1 diabetes mellitus. Case report: Type 1 diabetes mellitus (anti GAD-antibodies 2624 U/l, norm < 9.5) was diagnosed in a boy aged 14.3 years [170 cm (+ 0.93 SDS), weight 50.5 kg (+ 0.05 SDS)]. Laboratory work-up showed no evidence for other autoimmune disease. Family and past medical history were unremarkable. Growth and developmental milestones were normal. Insulin-analog based basal-bolus regime was initiated, associated to standard diabetic education. Routine psychological evaluation performed at the onset of diabetes revealed intermittent anxiety and obsessivecompulsive traits. Accordingly, a close psychiatric follow-up was initiated for the patient and his family. An adequate metabolic control (HbA1c drop from >14 to 8%) was achieved within 3 months, attributed to residual -cell function. In the following 6 months, HbA1c rose unexpectedly despite seemingly adequate adaptations of insulin doses. Obsessive fear of hypoglycemia leading to a severe compulsive behavior developed progressively with as many as 68 glycemia measurements per day (mean over 1 week). The patient reported that he could not bear leaving home with glycemia < 15 mmol/l, ending up with school eviction and severe intra-familial conflict. Despite intensive psychiatric outpatient support, HbA1c rose rapidly to >14% with glycemia-testing reaching peaks of 120 tests/day. The situation could only be discontinued through psychiatric hospitalization with intensive behavioral training. As a result, adequate metabolic balance was restored (HbA1c value: 7.1 %) with acceptable 10-15 daily glycemia measurements. Discussion: The association of overt psychiatric disorders to type 1 diabetes mellitus is very rare in the pediatric age group. It can lead to a pathological behavior with uncontrolled diabetes. Such exceptional situations require long-term admissions with specialized psychiatric care. Slow acceptation of a "less is better" principle in glycemia testing and amelioration of metabolic control are difficult to achieve.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The current issues debate brings together experts around the themes of self-sufficiency (in its national and European aspects) and of needs in cellular blood products. The point of view of the manufacturer and prescribers of blood products are confronted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: In type 1 diabetic patients (T1DM), nocturnal hypoglycaemias (NH) are a serious complication of T1DM treatment; self-monitoring of blood glucose (SMBG) is recommended to detect them. However, the majority of NH remains undetected on an occasional SMBG done during the night. An alternative strategy is the Continuous glucose monitoring (CGMS), which retrospectively shows the glycaemic profile. The aims of this retrospective study were to evaluate the true incidence of NH in T1DM, the best SMBG time to predict NH, the relationship between morning hyperglycaemia and NH (Somogyi phenomenon) and the utility of CGMS to reduce NH. METHODS: Eighty-eight T1DM who underwent a CGMS exam were included. Indications for CGMS evaluation, hypoglycaemias and correlation with morning hyperglycaemias were recorded. The efficiency of CGMS to reduce the suspected NH was evaluated after 6-9 months. RESULTS: The prevalence of NH was 67% (32% of them unsuspected). A measured hypoglycaemia at bedtime (22-24 h) had a sensitivity of 37% to detect NH (OR=2.37, P=0.001), while a single measure < or =4 mmol/l at 3-hour had a sensitivity of 43% (OR=4.60, P<0.001). NH were not associated with morning hyperglycaemias but with morning hypoglycaemias (OR=3.95, P<0.001). After 6-9 months, suspicions of NH decreased from 60 to 14% (P<0.001). CONCLUSION: NH were highly prevalent and often undetected. SMBG at bedtime, which detected hypoglycaemia had sensitivity almost equal to that of 3-hour and should be preferred because it is easier to perform. Somogyi phenomenon was not observed. CGMS is useful to reduce the risk of NH in 75% of patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rapport de synthèse : Hypoglycémies nocturnes chez les patients diabétiques de type 1 : que pouvons-nous apprendre de la mesure de la glycémie en continu ? But : les hypoglycémies nocturnes sont une complication majeure du traitement des patients diabétiques de type 1; des autocontrôles de la glycémie capillaire sont donc recommandés pour les détecter. Cependant, la majorité des hypoglycémies nocturnes ne sont pas décelées par un autocontrôle glycémique durant la nuit. La mesure de la glycémie en continu (CGMS) est une alternative intéressante. Les buts de cette étude rétrospective étaient d'évaluer la véritable incidence des hypoglycémies nocturnes chez des patients diabétiques de type 1, la meilleure période pour effectuer un autocontrôle permettant de prédire une hypoglycémie nocturne, la relation entre les hyperglycémies matinales et les hypoglycémies nocturnes (phénomène de Somogyi) ainsi que l'utilité du CGMS pour réduire les hypoglycémies nocturnes. Méthode : quatre-vingt-huit patients diabétiques de type 1 qui avaient bénéficié d'un CGMS ont été inclus. Les indications au CGMS, les hypoglycémies nocturnes et diurnes ainsi que la corrélation entre les hypoglycémies nocturnes et les hyperglycémies matinales durant le CGMS ont été enregistrées. L'efficacité du CGMS pour réduire les hypoglycémies nocturnes a été évaluée six à neuf mois après. Résultats : la prévalence des hypoglycémies nocturnes était de 67% (32% non suspectées). La sensibilité d'une hypoglycémie à prédire une hypoglycémie nocturne était de 37% (OR = 2,37, P = 0,001) lorsqu'elle survient au coucher (22-24 h) et de 43% lorsqu'elle survient à 3 h (OR = 4,60, P < 0,001). Les hypoglycémies nocturnes n'étaient pas associées à des hyperglycémies matinales, mais à des hypoglycémies matinales (OR = 3.95, P < 0.001). Six à neuf mois après le CGMS, les suspicions cliniques d'hypoglycémies nocturnes ont diminué de 60% à 14% (P < 0.001). Abstract : Aim. - In type 1 diabetic patients (TIDM), nocturnal hypoglycaemias (Nlï) are a serious complication of T1DM treatment; self-monitoring of blood glucose (SMBG) is recommended to detect them. However, the majority of NH remains undetected on an occasional SMBG done during the night. An alternative strategy is the Continuous glucose monitoring (CGMS), which retrospectively shows the glycaemic profile. The aims of this retrospective study were to evaluate the true incidence of NH in TiDM, the bèst SMBG time to predict NH, the relationship between morning hyperglycaemia and N$ (Somogyi phenomenon) and the utility of CGMS to reduce NH. Methods. -Eighty-eight T1DM who underwent a CGMS exam were included. Indications for CGMS evaluarion, hypoglycaemias and correlation with morning hyperglycaemias were recorded. The efficiency of CGMS to reduce the suspected NH was evaluated after 6-9 months. Results. -The prevalence of NH was 67% (32% of them unsuspected). A measured hypoglycaemia at bedtime (22-24 h) had a sensitivity of 37% to detect NH (OR = 2.37, P = 0.001), while a single measure <_ 4 mmol/l at 3-hour had a sensitivity of 43% (OR = 4.60, P < 0.001). NH were not associated with morning hyperglycaemias but with morning hypoglycaemias (OR = 3.95, P < 0.001). After 6-9 months, suspicions of NH decreased from 60 to 14% (P < 0.001). Conclusion. - NH were highly prevalent and often undetected. SMBG at bedtime, which detected hypoglycaemia had sensitivity almost equal to that of 3-hour and should be preferred because it is easier to perform. Somogyi phenomenon was not observed. CGMS is useful to reduce the risk of NH in 75% of patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this report is to address the benefits of the minimal invasive venous drainage in a pediatric cardio surgical scenario. Juvenile bovine experiments (67.4+/-11 kg) were performed. The right atrium was cannulated in a trans-jugular way by using the self-expandable (Smart Stat, 12/20F, 430 mm) venous cannula (Smartcannula LLC, Lausanne, Switzerland) vs. a 14F 250 mm (Polystan Lighthouse) standard pediatric venous cannula. Establishing the cardiopulmonary bypass (CPB), the blood flows were assessed for 20 mmHg, 30 mmHg and 40 mmHg of driving pressure. Venous drainage (flow in l/min) at 20 mmHg, 30 mmHg, and 40 mmHg drainage load was 0.26+/-0.1, 0.35+/-0.2 and 0.28+/-0.08 for the 14F standard vs. 1.31+/-0.22, 1.35+/-0.24 and 1.9+/-0.2 for the Smart Stat 12/20F cannula. The 43 cm self-expanding 12/20F Smartcannula outperforms the 14F standard cannula. The results described herein allow us to conclude that usage of the self-expanding Smartcannula also in the pediatric patients improves the flow and the drainage capacity, avoiding the insufficient and excessive drainage. We believe that similar results may be expected in the clinical settings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ambulatory blood pressure (BP) monitoring is increasingly used in the evaluation of hypertensive patients. The ability to monitor BP throughout the day and night allows the detection of abnormal nocturnal BP patterns, the most common being a "nondipping" pattern, which is associated with increased cardiovascular risk; its correction appears to have a positive impact on cardiovascular outcome. Antihypertensive treatment should be individually adjusted to control BP during both daytime and nighttime. However, drug-induced lowering of nocturnal BP, if excessive, could amplify the morning BP surge in patients with daytime BP elevation, increasing the risk of developing a cardiovascular event. Ambulatory BP monitoring therefore represents a unique tool to establish the most appropriate antihypertensive drug regimen for the individual patient.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Within the framework of the «Programme cantonal Diabète», we aimed at collecting data to 1) describe the population of diabetic patients in the canton of Vaud, and 2) assess the quality of their care. Methods: A cross-sectional study was conducted in the fall of 2011. Out of 140 randomly selected community pharmacies registered in the canton of Vaud, 56 accepted to participate in patients' recruitment. Noninstitutionalized adult diabetic patients (disease duration >12 months) visiting a pharmacy with a prescription for oral anti-diabetic drugs, insulin, glycemic strips or glucose meter were eligible. Patients not residing in the canton of Vaud, not speaking and understanding French well enough, presenting obvious cognitive impairment, and women with gestational diabetes, were excluded. Using a self-administered questionnaire, data was collected on patients' characteristics and diabetes as well as various process (e.g. recommended annual screenings) and outcomes quality of care indicators. Descriptive analyses were performed. Results: A total of 406 patients with diabetes participated. Mean age was 64 years, 41% were women and 63% were married. Patients reported type 1, 2 and other types of diabetes in 13%, 69% and 19%, respectively. They were treated with oral anti-diabetic drugs, insulin or both in 50%, 23% and 27% of the cases. Half of the patients did not report any diabetes-related complication. Glucose self-monitoring was reported by 82% of the patients. Of those who were aware of HbA1C (n = 218), 98% reported at least one HbA1C control during the last 12 months. During that same time frame, 97% and 95% reported at least one blood pressure and weight measure, 94% reported having had a cholesterol check, 74%, 68% and 64% had eyes, feet and urine screening respectively. 62% of the patients had been immunized against influenza. At least 76% of the patients had a minimum of 5 of the 7 described process indicators performed during the last 12 months. Among patients who knew the value (n = 145), mean HbA1C was 7.4 (SD 1.2). Conclusion: This study targeting community-based diabetic patients shows that while routine clinical and laboratory tests were annually performed in the vast majority of patients, feet and urine screening, as well as influenza immunization, were less often reported by patients. The proportion of patients with diabetes having had at least 5 out of the 7 annual screenings performed was nevertheless very high.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ETHNOPHARMACOLOGICAL RELEVANCE: The aim of this survey was to describe which traditional medicines (TM) are most commonly used for non-communicable diseases (NCD - diabetes, hypertension related to excess weight and obesity) in Pacific islands and with what perceived effectiveness. NCD, especially prevalent in the Pacific, have been subject to many public health interventions, often with rather disappointing results. Innovative interventions are required; one hypothesis is that some local, traditional approaches may have been overlooked. MATERIALS AND METHODS: The method used was a retrospective treatment-outcome study in a nation-wide representative sample of the adult population (about 15,000 individuals) of the Republic of Palau, an archipelago of Micronesia. RESULTS: From 188 respondents (61% female, age 16-87, median 48,), 30 different plants were used, mostly self-prepared (69%), or from a traditional healer (18%). For excess weight, when comparing the two most frequent plants, Morinda citrifolia L. was associated with more adequate outcome than Phaleria nishidae Kaneh. (P=0.05). In case of diabetes, when comparing Phaleria nishidae (=Phaleria nisidai) and Morinda citrifolia, the former was statistically more often associated with the reported outcome "lower blood sugar" (P=0.01). CONCLUSIONS: Statistical association between a plant used and reported outcome is not a proof of effectiveness or safety, but it can help select plants of interest for further studies, e.g. through a reverse pharmacology process, in search of local products which may have a positive impact on population health.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: A study was undertaken to develop a score for assessing risk for symptomatic intracranial hemorrhage (sICH) in ischemic stroke patients treated with intravenous (IV) thrombolysis. METHODS: The derivation cohort comprised 974 ischemic stroke patients treated (1995-2008) with IV thrombolysis at the Helsinki University Central Hospital. The predictive value of parameters associated with sICH (European Cooperative Acute Stroke Study II) was evaluated, and we developed our score according to the magnitude of logistic regression coefficients. We calculated absolute risks and likelihood ratios of sICH per increasing score points. The score was validated in 828 patients from 3 Swiss cohorts (Lausanne, Basel, and Geneva). Performance of the score was tested with area under a receiver operating characteristic curve (AUC-ROC). RESULTS: Our SEDAN score (0 to 6 points) comprises baseline blood Sugar (glucose; 8.1-12.0 mmol/l [145-216 mg/dl] = 1; >12.0 mmol/l [>216 mg/dl] = 2), Early infarct signs (yes = 1) and (hyper)Dense cerebral artery sign (yes = 1) on admission computed tomography scan, Age (>75 years = 1), and NIH Stroke Scale on admission (≥10 = 1). Absolute risk for sICH in the derivation cohort was: 1.4%, 2.9%, 8.5%, 12.2%, 21.7%, and 33.3% for 0, 1, 2, 3, 4, and 5 score points, respectively. In the validation cohort, absolute risks were similar (1.0%, 3.5%, 5.1%, 9.2%, 16.9%, and 27.8%, respectively). AUC-ROC was 0.77 (0.71-0.83; p < 0.001). INTERPRETATION: Our SEDAN score reliably assessed risk for sICH in IV thrombolysis-treated patients with anterior- and posterior circulation ischemic stroke, and it can support clinical decision making in high-risk patients. External validation of the score supports its generalization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cet article présente les résultats de la revue systématique: Garcia-Alamino JM, Ward AM, Alonso-Coello P, et al. Self-monitoring and self-management of oral anticoagulation. Cochrane Database of Systematic Reviews 2010, Issue 4. Art. No. : CD003839. DOI: 10.1002/14651858.CD003839.pub2.. PMID: 20393937.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A passive sampling device called Monitor of NICotine or "MoNIC", was constructed and evaluated by IST laboratory for determining nicotine in Environmental Tobacco Smoke (ETS). Vapour nicotine was passively collected on a potassium bisulfate treated glass fibre filter as collection medium. Analysis of amount of nicotine on the treated filter by gas chromatography equipped with Thermoionic-Specific Detector (GCTSD) after liquid-liquid extraction of 1mL of 5N NaOH : 1 mL of n-heptane saturated with NH3 using quinoline as internal standard. Based on nicotine amount of 0.2 mg/cigarette as reference, the inhaled Cigarette Equivalents (CE) by non-smokers can be calculated. Using the detected CE on the badge for nonsmokers, and comparing with amount of nicotine and cotinine level in saliva of both smokers and exposed non-smokers (N=49), we can confirm the use of the CE concept for estimating exposure to ETS. The Valais CIPRET (Center of information and prevention of the addiction to smoking), is going to organize a big campaign on the subject of the passive addiction to smoking entitled "Smoked passive, we suffer from it, we die from it ". This campaign will take place in 2007 and has for objective to inform clearly the population of Valais of the dangerousness of the passive smoke. More than 1'500 MoNIC badges were gracefully distributed to Swiss population to perform a self-monitoring of population exposure level to ETS, expressed in term of CE. Non-stimulated saliva were also collected to determine ETS biomarkers nicotine/cotinine levels of participating volunteers. Preliminary results of different levels of CE in occupational and non-occupational situations in relation with ETS were presented in this study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hypoglycaemia can occur if the endogenous liver glucose output is lower than the glucose uptake in insulin-sensitive and insulin-insensitive tissues. The onset of hypoglycaemia induces the production of counterregulatory hormones such as glucagon, epinephrine, growth hormone and cortisol, and symptoms of neuroglycopenia. The correlation between biological hypoglycaemia and the symptoms associated with low blood sugar is particularly poor in diabetic patients and in patients with suspected postprandial hypoglycaemia. It is important to discriminate between fasting and postprandial hypoglycaemia. Idiopathic postprandial hypoglycaemia should be diagnosed clinically without further laboratory assessment, whereas the etiology of a fasting hypoglycaemia needs to be clarified further by laboratory testing, as it is potentially life-threatening.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A passive sampling device called Monitor of NICotine or "MoNIC", was constructed and evaluated by IST laboratory for determining nicotine in Second Hand Tobacco Smoke (SHTS) or Environmental Tobacco Smoke (ETS). Vapour nicotine was passively collected on a potassium bisulfate treated glass fibre filter as collection medium. Analysis of collected nicotine on the treated filter by gas chromatography equipped with Thermoionic-Specific Detector (GC-TSD) after liquid-liquid extraction of 1mL of 5N NaOH : 1 mL of n-heptane saturated with NH3 using quinoline as internal standard. Based on nicotine amount of 0.2 mg/cigarette as the reference, the inhaled Cigarette Equivalents (CE) by non-smokers can be calculated. Using the detected CE on the badge for non-smokers, and comparing with amount of nicotine and cotinine level in saliva of both smokers and exposed non-smokers, we can confirm the use of the CE concept for estimating exposure to ETS. The regional CIPRET (Center of information and prevention of the addiction to smoking) of different cantons (Valais (VS), Vaud (VD), Neuchâtel (NE) and Fribourg (FR)) are going to organize a big campaign on the subject of the passive addiction to smoking. This campaign took place in 2007-2008 and has for objective to inform clearly the Swiss population of the dangerousness of the passive smoke. More than 3'900 MoNIC badges were gracefully distributed to Swiss population to perform a self-monitoring of population exposure level to ETS, expressed in term of CE. Non-stimulated saliva was also collected to determine ETS biomarkers nicotine/cotinine levels of participating volunteers. Results of different levels of CE in occupational and non-occupational situations in relation with ETS were presented in this study. This study, unique in Switzerland, has established a base map on the population's exposure to SHTS. It underscored the fact that all the Swiss people involved in this campaign (N=1241) is exposed to passive smoke, from <0.2 cig/d (10.8%), 1-2 to more than 10 cig/d (89.2%). In the area of high exposure (15-38 cig/d), are the most workers in public restaurant, cafe, bar, disco. By monitoring ETS tracer nicotine and its biomarkers, salivary nicotine and cotinine, it is demonstrated that the MoNIC badge can serve as indicator of CE passive smoking. The MoNIC badge, accompanied with content of salivary nicotine/cotinine can serve as a tool of evaluation of the ETS passive smoking and contributes to supply useful data for future epidemiological studies. It is also demonstrated that the salivary nicotine (without stimulation) is a better biomarker of ETS exposure than cotinine.