3 resultados para Blood parameters
em Université de Lausanne, Switzerland
Resumo:
According to the hypothesis of Traub, also known as the 'formula of Traub', postmortem values of glucose and lactate found in the cerebrospinal fluid or vitreous humor are considered indicators of antemortem blood glucose levels. However, because the lactate concentration increases in the vitreous and cerebrospinal fluid after death, some authors postulated that using the sum value to estimate antemortem blood glucose levels could lead to an overestimation of the cases of glucose metabolic disorders with fatal outcomes, such as diabetic ketoacidosis. The aim of our study, performed on 470 consecutive forensic cases, was to ascertain the advantages of the sum value to estimate antemortem blood glucose concentrations and, consequently, to rule out fatal diabetic ketoacidosis as the cause of death. Other biochemical parameters, such as blood 3-beta-hydroxybutyrate, acetoacetate, acetone, glycated haemoglobin and urine glucose levels, were also determined. In addition, postmortem native CT scan, autopsy, histology, neuropathology and toxicology were performed to confirm diabetic ketoacidosis as the cause of death. According to our results, the sum value does not add any further information for the estimation of antemortem blood glucose concentration. The vitreous glucose concentration appears to be the most reliable marker to estimate antemortem hyperglycaemia and, along with the determination of other biochemical markers (such as blood acetone and 3-beta-hydroxybutyrate, urine glucose and glycated haemoglobin), to confirm diabetic ketoacidosis as the cause of death.
Resumo:
Several studies have reported high levels of inflammatory biomarkers in hypertension, but data coming from the general population are sparse, and sex differences have been little explored. The CoLaus Study is a cross-sectional examination survey in a random sample of 6067 Caucasians aged 35-75 years in Lausanne, Switzerland. Blood pressure (BP) was assessed using a validated oscillometric device. Anthropometric parameters were also measured, including body composition, using electrical bioimpedance. Crude serum levels of interleukin-6 (IL-6), tumor necrosis factor α (TNF-α) and ultrasensitive C-reactive protein (hsCRP) were positively and IL-1β (IL-1β) negatively (P<0.001 for all values), associated with BP. For IL-6, IL-1β and TNF-α, the association disappeared in multivariable analysis, largely explained by differences in age and body mass index, in particular fat mass. On the contrary, hsCRP remained independently and positively associated with systolic (β (95% confidence interval): 1.15 (0.64; 1.65); P<0.001) and diastolic (0.75 (0.42; 1.08); P<0.001) BP. Relationships of hsCRP, IL-6 and TNF-α with BP tended to be stronger in women than in men, partly related to the difference in fat mass, yet the interaction between sex and IL-6 persisted after correction for all tested confounders. In the general population, the associations between inflammatory biomarkers and rising levels of BP are mainly driven by age and fat mass. The stronger associations in women suggest that sex differences might exist in the complex interplay between BP and inflammation.
Resumo:
Black-blood fast spin-echo imaging is a powerful technique for the evaluation of cardiac anatomy. To avoid fold-over artifacts, using a sufficiently large field of view in phase-encoding direction is mandatory. The related oversampling affects scanning time and respiratory chest motion artifacts are commonly observed. The excitation of a volume that exclusively includes the heart without its surrounding structures may help to improve scan efficiency and minimize motion artifacts. Therefore, and by building on previously reported inner-volume approach, the combination of a black-blood fast spin-echo sequence with a two-dimensionally selective radiofrequency pulse is proposed for selective "local excitation" small field of view imaging of the heart. This local excitation technique has been developed, implemented, and tested in phantoms and in vivo. With this method, small field of view imaging of a user-specified region in the human thorax is feasible, scanning becomes more time efficient, motion artifacts can be minimized, and additional flexibility in the choice of imaging parameters can be exploited.