3 resultados para Best ACRL College Library of 2002
em Université de Lausanne, Switzerland
Resumo:
Swain corrects the chi-square overidentification test (i.e., likelihood ratio test of fit) for structural equation models whethr with or without latent variables. The chi-square statistic is asymptotically correct; however, it does not behave as expected in small samples and/or when the model is complex (cf. Herzog, Boomsma, & Reinecke, 2007). Thus, particularly in situations where the ratio of sample size (n) to the number of parameters estimated (p) is relatively small (i.e., the p to n ratio is large), the chi-square test will tend to overreject correctly specified models. To obtain a closer approximation to the distribution of the chi-square statistic, Swain (1975) developed a correction; this scaling factor, which converges to 1 asymptotically, is multiplied with the chi-square statistic. The correction better approximates the chi-square distribution resulting in more appropriate Type 1 reject error rates (see Herzog & Boomsma, 2009; Herzog, et al., 2007).
Resumo:
OBJECTIVE: The purpose of the present study was to submit the same materials that were tested in the round robin wear test of 2002/2003 to the Alabama wear method. METHODS: Nine restorative materials, seven composites (belleGlass, Chromasit, Estenia, Heliomolar, SureFil, Targis, Tetric Ceram) an amalgam (Amalcap) and a ceramic (IPS Empress) have been submitted to the Alabama wear method for localized and generalized wear. The test centre did not know which brand they were testing. Both volumetric and vertical loss had been determined with an optical sensor. After completion of the wear test, the raw data were sent to IVOCLAR for further analysis. The statistical analysis of the data included logarithmic transformation of the data, the calculation of relative ranks of each material within each test centre, measures of agreement between methods, the discrimination power and coefficient of variation of each method as well as measures of the consistency and global performance for each material. RESULTS: Relative ranks of the materials varied tremendously between the test centres. When all materials were taken into account and the test methods compared with each other, only ACTA agreed reasonably well with two other methods, i.e. OHSU and ZURICH. On the other hand, MUNICH did not agree with the other methods at all. The ZURICH method showed the lowest discrimination power, ACTA, IVOCLAR and ALABAMA localized the highest. Material-wise, the best global performance was achieved by the leucite reinforced ceramic material Empress, which was clearly ahead of belleGlass, SureFil and Estenia. In contrast, Heliomolar, Tetric Ceram and especially Chromasit demonstrated a poor global performance. The best consistency was achieved by SureFil, Tetric Ceram and Chromasit, whereas the consistency of Amalcap and Heliomolar was poor. When comparing the laboratory data with clinical data, a significant agreement was found for the IVOCLAR and ALABAMA generalized wear method. SIGNIFICANCE: As the different wear simulator settings measure different wear mechanisms, it seems reasonable to combine at least two different wear settings to assess the wear resistance of a new material.
Resumo:
PURPOSE: Acute limb ischemia after thrombosis of a popliteal aneurysm is a distinct and limb-threatening entity. Preoperative intra-arterial thrombolysis may improve the outcome in this challenging situation. This study retrospectively analyzed a consecutive series of patients treated with preoperative thrombolysis and subsequent revascularization. METHODS: Thirteen patients with acute limb ischemia caused by thrombosis of a popliteal aneurysm underwent catheter-directed intra-arterial thrombolysis with urokinase and subsequent vascular reconstruction. The angiographic and clinical outcome was analyzed and compared with that in the literature. RESULTS: Complete aneurysm thrombosis with absence of runoff was documented in 12 cases. Thrombolysis restored perfusion with patency of the popliteal artery and a one- or two-vessel runoff in 77% of cases (10/13). Early cumulative graft patency and limb salvage rates were 68% and 83%, respectively, with an ankle/brachial index of 0.8 +/- 0.2. Lytic failure followed by attempts at bypass grafting was present in three patients (23%) and resulted in above-knee amputation. Severe rhabdomyolysis and fatal pulmonary embolism were responsible for a 15% early mortality rate. CONCLUSION: Preoperative thrombolysis followed by bypass grafting is a valid treatment option for patients who can withstand an additional period of ischemia that does not require immediate revascularization and intraoperative lysis. Lytic failure identifies patients with a highly compromised runoff who are probably best treated by means of subsequent amputation, without any attempts at bypass grafting.