22 resultados para Beam interferences

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the efficacy of first-line chemotherapy (CT) in preventing external-beam radiotherapy (EBR) and/or enucleation in patients with retinoblastoma (Rbl). PATIENTS AND METHODS: Twenty-four patients with newly diagnosed unilateral or bilateral Rbl received CT associated with local treatment (LT). Two to five courses of etoposide and carboplatin were administered at 3- to 4-week intervals, depending on tumor response, and were completed each time by LT. RESULTS: Tumor response was observed in all eyes. Twenty-one of 24 patients showed a complete response (CR) that persisted at a median follow-up (FU) of 31 months (range, 4 to 41 months). Among the three patients who relapsed, two were lost to FU and one died of progressive disease. CR was achieved by CT and LT alone in 15 (71.4%) of 21 patients with less advanced disease (groups I to III). Six other patients with advanced disease (groups IV and V) experienced treatment failure and needed salvage treatment by EBR and/or enucleation. The difference between the two patient groups with regard to disease stage was statistically significant (P <.0001). EBR could be avoided in 13 (68.4%) of 19 patients, who presented with groups I to III (15 eyes) and group V (one eye) disease, whereas enucleation could be avoided in only two (40%) of five. CONCLUSION: CT combined with intensive LT is effective in patients with groups I to III Rbl, permitting the avoidance of EBR in the majority of these young children and, thus, reducing the risk of long-term sequelae. This is in contrast with the disappointing results for patients with groups IV and V Rbl, in whom EBR and/or enucleation was needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Melanoma of the iris and ciliary body may be associated with secondary glaucoma. Treatment with proton beam radiotherapy (PBRT) to the anterior segment can also elevate intraocular pressure (IOP), resulting in uncontrolled glaucoma, often requiring enucleation. This is the first prospective study of Baerveldt aqueous shunts in irradiated eyes with anterior uveal melanoma (AUM; affecting the iris or ciliary body). METHODS: Thirty-one eyes with uncontrolled IOP following anterior segment PBRT treatment for AUM were prospectively recruited to undergo Baerveldt shunt implantation. Postoperative examinations were performed on day 1; weeks 1, 3, 6, 9; months 3, 6, 9, 12 and annually thereafter. Surgical success was defined as IOP 21 mm Hg or less and 20% reduction from baseline. All complications were recorded. RESULTS: Mean follow-up was 15.7 months (SD ±8.3 months). Mean interval from irradiation to shunt implantation was 2.5 years. Mean preoperative IOP was 31.0 (±10.3) mm Hg; mean IOP at last visit was 15.0 (±5.0) mm Hg; mean pre-operative glaucoma medications were 3.3 (±1.3); postoperatively 0.7 (±1.3) glaucoma medications. Surgical success rate was 86% using glaucoma medications. Four eyes had minor postoperative complications, none of which were sight threatening. There were no local tumour recurrences or systemic metastases. There were no enucleations caused by ocular hypertension. CONCLUSIONS: Baerveldt shunts were effective in lowering IOP, with few complications, in eyes treated with total anterior segment irradiation for AUM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To report on trans-scleral local resection of choroidal melanoma for exudative retinal detachment and neovascular glaucoma (toxic tumour syndrome) after proton beam radiotherapy (PBR). METHODS: A non-randomised, prospective study of secondary trans-scleral local resection of choroidal melanoma for exudative retinal detachment with or without neovascular glaucoma after PBR. The patients were treated at the Liverpool Ocular Oncology Centre between February 2000 and April 2008. The trans-scleral local resection was performed with a lamellar-scleral flap, using systemic hypotension to reduce haemorrhage. RESULTS: 12 patients (six women, six men) with a mean age of 51 years (range 20-75) were included in this study. The tumour margins extended anterior to ora serrata in six patients. On ultrasonography, the largest basal tumour dimension averaged 12.4 mm (range 6.8-18.1) and the tumour height averaged 7.1 mm (range 4.2-10.7). The retinal detachment was total in seven patients. Neovascular glaucoma was present in four patients. The time between PBR and local resection had a mean of 17.4 months (range 1-84). The ophthalmic follow-up time after the local resection had a mean of 46.2 months (range 14-99). At the latest known status, the eye was conserved in 10 patients, with a flat retina in all these patients and visual acuity equal or better than 6/30 in four patients. The reasons for enucleation were: patient request for enucleation when rhegmatogenous retinal detachment complicated the resection (one patient) and phthisis (one patient). CONCLUSIONS: Exudative retinal detachment, rubeosis and neovascular glaucoma after PBR of a choroidal melanoma can resolve after trans-scleral local resection of the tumour. Our findings suggest that these complications are caused by the persistence of the irradiated tumour within the eye ('toxic tumour syndrome').

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Collateral damage to upper eyelid margin during proton beam radiotherapy (PBR) for choroidal melanoma may cause squamous metaplasia of the tarsal conjunctiva with keratinisation, corneal irritation, discomfort and, rarely, corneal perforation. We evaluated transpalpebral PBR as a means of avoiding collateral damage to the upper eyelid margin without increasing the risk of failure of local tumour control. METHODS: Retrospective study of consecutive patients who underwent PBR for choroidal melanoma between 1992 and 2007 at the Royal Liverpool University Hospital and the Douglas Cyclotron at Clatterbridge Cancer Centre, UK. RESULTS: Sixty-three patients were included in this study. Mean basal tumour diameter and tumour thickness were 11.8 mm and 3.6 mm, respectively. PBR mean beam range and modulation were 26.5 mm and 16.9 mm respectively. The eyelid margin was included in the radiation field in 15 (24%) eyes. The median follow-up was 2.5 years. Local tumour recurrence developed in 2 (3.2%) patients. In these two cases that developed tumour recurrence the transpalpebral treatment did not involve the eyelid margin. Six (9.5%) patients died of metastatic disease. No eyelid or ocular surface problems developed in any of the 48 patients who were treated without eyelid rim involvement, while 7 of the 15 patients with unavoidable irradiation of the eyelid rim developed some degree of madarosis. These seven patients all received more than 26.55 proton Gy to the eyelid margin. Symptoms, such as grittiness occurred in 12% of 48 patients without eyelid margin irradiation as compared with 53% of 15 patients whose lid margin was irradiated. CONCLUSIONS: Transpalpebral PBR of choroidal melanoma avoids eyelid and ocular surface complications without increasing failure of local tumour control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study seeks to perform a survey of patterns of practice among the different physicians involved in the bone metastases management, with special focus on external beam radiotherapy (EBRT).A questionnaire about bone metastases based on clinical cases and supplemented with general questions, including medical therapies, EBRT and metabolic radiotherapy strategies, surgery, and supportive care approaches, was sent to 4,706 French-speaking physicians in Belgium, France, Luxemburg, and Switzerland.Overall, 644 questionnaires were analyzed. Twenty-eight percent concerned the radiotherapy approach and were judged adequate to respond to the part dedicated to EBRT. Sixty-nine percent of physicians used a total dose irradiation of 30 Gy delivered in ten fractions. A large majority (75%) used two opposed fields prescribed at mid-depth (30%), or with non-equally weighted fields (45%). Seventy percent irradiated also above and below the concerned vertebra. A dosimetry planning treatment was done in 85% and high-energy megavoltage photons were used in 42%. Moreover, 54% physicians used short course radiotherapy in routine.Radiotherapy remains the mainstay of treatment of bone metastases, but there is substantial heterogeneity in clinical practice. Guidelines and treatment protocols are required to improve the treatment quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: To determine the outcome of patients with brain metastasis (BM) from lung cancer treated with an external beam radiotherapy boost (RTB) after whole brain radiotherapy (WBRT). METHODS: A total of 53 BM patients with lung cancer were treated sequentially with WBRT and RTB between 1996 and 2008 according to our institutional protocol. Mean age was 58.8 years. The median KPS was 90. Median recursive partitioning analysis (RPA) and graded prognostic assessment (GPA) grouping were 2 and 2.5, respectively. Surgery was performed on 38 (71%) patients. The median number of BM was 1 (range, 1-3). Median WBRT and RTB combined dose was 39 Gy (range, 37.5-54). Median follow-up was 12.0 months. RESULTS: During the period of follow-up, 37 (70%) patients died. The median overall survival (OS) was 14.5 months. Only 13 patients failed in the brain. The majority of patients (n = 29) failed distantly. The 1-year OS, -local control, extracranial failure rates were 61.2%, 75.2% and 60.8%, respectively. On univariate analysis, improved OS was found to be significantly associated with total dose (< or = 39 Gy vs. > 39 Gy; p < 0.01), age < 65 (p < 0.01), absence of extracranial metastasis (p < 0.01), GPA > or = 2.5 (p = 0.01), KPS > or = 90 (p = 0.01), and RPA < 2 (p = 0.04). On multivariate analysis, total dose (p < 0.01) and the absence of extracranial metastasis (p = 0.03) retained statistical significance. CONCLUSIONS: The majority of lung cancer patients treated with WBRT and RTB progressed extracranially. There might be a subgroup of younger patients with good performance status and no extracranial disease who may benefit from dose escalation after WBRT to the metastatic site.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the end of the last millennium, the focused ion beam scanning electron microscopy (FIB-SEM) has progressively found use in biological research. This instrument is a scanning electron microscope (SEM) with an attached gallium ion column and the 2 beams, electrons and ions (FIB) are focused on one coincident point. The main application is the acquisition of three-dimensional data, FIB-SEM tomography. With the ion beam, some nanometres of the surface are removed and the remaining block-face is imaged with the electron beam in a repetitive manner. The instrument can also be used to cut open biological structures to get access to internal structures or to prepare thin lamella for imaging by (cryo-) transmission electron microscopy. Here, we will present an overview of the development of FIB-SEM and discuss a few points about sample preparation and imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One-hundred patients treated with curative radiotherapy (RT) ± chemotherapy (CT) for an anal canal carcinoma (T1-4N0-3M0) were retrospectively analyzed. Five- and 10-year local control (LC) rates were 73% and 67%, respectively. Acute and late G3-G4 toxicity rates were 32% and 12%, respectively. Two patients underwent a colostomy for a G4 anal toxicity. This study confirms the outcomes of RT ± CT in the treatment of anal canal cancer. Concomitant CT and LC statistically influenced Overall Survival and Colostomy-Free Survival. CT also statistically reduced the risk of nodal relapse. High rates of acute skin toxicity impose tailored volumes and techniques of irradiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Ocular anatomy and radiation-associated toxicities provide unique challenges for external beam radiation therapy. For treatment planning, precise modeling of organs at risk and tumor volume are crucial. Development of a precise eye model and automatic adaptation of this model to patients' anatomy remain problematic because of organ shape variability. This work introduces the application of a 3-dimensional (3D) statistical shape model as a novel method for precise eye modeling for external beam radiation therapy of intraocular tumors. METHODS AND MATERIALS: Manual and automatic segmentations were compared for 17 patients, based on head computed tomography (CT) volume scans. A 3D statistical shape model of the cornea, lens, and sclera as well as of the optic disc position was developed. Furthermore, an active shape model was built to enable automatic fitting of the eye model to CT slice stacks. Cross-validation was performed based on leave-one-out tests for all training shapes by measuring dice coefficients and mean segmentation errors between automatic segmentation and manual segmentation by an expert. RESULTS: Cross-validation revealed a dice similarity of 95% ± 2% for the sclera and cornea and 91% ± 2% for the lens. Overall, mean segmentation error was found to be 0.3 ± 0.1 mm. Average segmentation time was 14 ± 2 s on a standard personal computer. CONCLUSIONS: Our results show that the solution presented outperforms state-of-the-art methods in terms of accuracy, reliability, and robustness. Moreover, the eye model shape as well as its variability is learned from a training set rather than by making shape assumptions (eg, as with the spherical or elliptical model). Therefore, the model appears to be capable of modeling nonspherically and nonelliptically shaped eyes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To report the results of whole anterior segment proton beam radiotherapy (PBR) for diffuse iris melanoma. METHODS: Between 2000 and 2011, 12 patients with iris melanoma received PBR to the entire iris and ciliary body. RESULTS: Patients had a mean age of 57 years and a median follow-up of 3.5 years (range 1-11.6 years). Tumour iris involvement was 1-4 h in five patients, 5-8 h in four and 9-12 h in three. Angle involvement was 6-8 h in five patients and 9-12 h in seven. The visual acuity (VA) before treatment was 6/5-6/6 in six patients, 6/8-6/9 in three and 6/18-6/38 in three. No tumour recurrence occurred during the follow-up period. Glaucoma treatment was required in 11 of 12 patients. The visual acuity at the last follow-up was 6/5-6/9 in five patients, 6/18-6/24 in three, 6/60-1/60 in two and no light perception in two. Four patients developed varying non-severe degrees of limbal stem cell deficiency, which was treatable with conservative measures. CONCLUSIONS: Whole anterior segment PBR is a useful alternative to enucleation for diffuse iris melanoma. Most patients will need treatment for glaucoma and some may require treatment for tear-film instability and/or stem cell failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report neovascular glaucoma after proton-beam radiotherapy of an adenocarcinoma of the pigmented ciliary epithelium and its successful treatment by iridocyclectomy. PATIENT AND METHODS: A 65-year-old man developed neovascular glaucoma 10 months after proton-beam radiotherapy of a small pigmented iridociliary tumour with a clinical differential diagnosis of uveal melanoma or adenocarcinoma. The diagnosis of 'toxic tumour syndrome' was made, and iridocyclectomy performed. RESULTS: Histopathology and immunohistochemistry of the specimen diagnosed an adenocarcinoma of the pigmented ciliary epithelium, with the presence of mitoses suggesting residual viable tumour cells. The rubeosis regressed, with normalization of the intraocular pressure. Phacoemulsification for radiation-induced cataract restored VA to 6/9, which was better than that recorded at initial referral, the patient having longstanding cellophane maculopathy. CONCLUSIONS: Neovascular glaucoma after radiotherapy of a small, pigmented, ciliary body tumour raises the possibility of adenocarcinoma. This 'toxic tumour syndrome' may respond to iridocyclectomy of the irradiated tumour.