76 resultados para Balloon
em Université de Lausanne, Switzerland
Resumo:
Intraoperative cardiac imaging plays a key role during transcatheter aortic valve replacement. In recent years, new techniques and new tools for improved image quality and virtual navigation have been proposed, in order to simplify and standardize stent valve positioning and implantation. But routine performance of the new techniques may require major economic investments or specific knowledge and skills and, for this reason, they may not be accessible to the majority of cardiac centres involved in transcatheter valve replacement projects. Additionally, they still require injections of contrast medium to obtain computed images. Therefore, we have developed and describe here a very simple and intuitive method of positioning balloon-expandable stent valves, which represents the evolution of the 'dumbbell' technique for echocardiography-guided transcatheter valve replacement without angiography. This method, based on the partial inflation of the balloon catheter during positioning, traps the crimped valve in the aortic valve orifice and, consequently, very near to the ideal landing zone. It does not require specific echocardiographic knowledge; it does not require angiographies that increase the risk of postoperative kidney failure in elderly patients, and it can be also performed in centres not equipped with a hybrid operating room.
Resumo:
RESUME : Actuellement la brachythérapie endovasculaire reste le seul traitement efficace pour la resténose intrastent. Malgré ceci, la limitation majeure de cette technique est la resténose aux extrémités du stent (effet de bord) due à une couverture incomplète par la source radioactive (geographical miss). Le ballon coupant et qui ne glisse pas pourrait limiter le barotraumatisme engendré par la dilatation et qui avec la diminution de la radiation aux extrémités de la source radioactive, est à la base du geographical miss. Cette étude prospective a pour but d'examiner l'efficacité du traitement de la resténose intrastent par la combinaison d'angioplastie avec cutting ballon et β - irradiation. Le registre « Radiation in Europe NOvoste » (RENO) inclut tous les patients traités par β - irradiation coronaire avec le système Beta-CathTM System (Novoste Corporation, Brussels, Belgium) n'ayant pas été inclus dans une autre étude randomisée. Un premier sous-groupe de ces patients (groupe 1, n=166), représente les patients traités par cutting ballon et β - irradiation intra coronaire. Ce groupe a été défini d'une manière prospective et les résultats cliniques à 6 mois ont été comparés par rapport aux autres patients qui ont reçu un traitement par dilatation coronaire conventionnelle et β - irradiation (groupe 2, n=712). A 6 mois de suivi, on a retrouvé une différence significative entre les 2 groupes par rapport à la nécessité d'une nouvelle revascularisation du vaisseau préalablement traité (10,2% de récidive dans le groupe 1 contre 16,6 % dans le groupe 2 , p=0,04). Le nombre d'événements cardiaques majeurs (mortalité, infarctus du myocarde et revascularisation) a également été diminué de manière significative (10,8% contre 19,2% ; />=0,01). Cette observation a été confirmée par une analyse multivariée qui indique un risque diminué pour les événements cardiaques majeurs à 6 mois, (rapport de côtes : 0,49 ; intervalle de confiance 0,27-0,88 ; p=0,02). Comparé à l'angioplastie coronarienne avec ballon conventionnel, l'utilisation de cutting ballon avant la β - irradiation dans le traitement de la resténose intrastent démontre une meilleure évolution clinique à 6 mois. ABSTRACT: At present, vascular brachytherapy is the only efficient therapy for in-stent restenosis. Nevertheless edge restenosis often relat¬ed to geographical miss has been identified as a major limitation of the technique. The non-slippery cutting balloon has the potential to limit vascular barotraumas which, together with low-dose irradiation at both ends of the radioactive source, are the prerequisite for geographical miss. This prospective study aimed to examine the efficacy of combining cut¬ting balloon angioplasty and brachytherapy for in-stent restenosis. The Radiation in Europe NOvoste (RENO) registry prospectively tracked all patients who had been treated by coronary β-radiation with the Beta-CathTM System (Novoste Corporation. Brussels, Belgium) but were not included in a randomized radiation trial, A subgroup of patients with in-stent restenosis treated by cutting balloon angioplasty and coronary β-radiation (group 1, n = 166) was prospectively defined, and clinical outcomes of patients at 6 months were compared with those of patients treated by conventional angioplasty and coronary β -radiation (group 2, n = 712). At 6-month follow-up, there was a significant difference between groups 1 and 2 in- target vessel revascularization (10.2% versus 16.6% respectively; p = 0.04) and in the incidence of major adverse clinical events (MACE) including, death, myocardial infarction, and revascularization (10.8% versus 19.2%; p= 0.01). This observation was confirmed by a multivariate analysis indicating a. lower risk for MACE at 6 months (odds ratio: 0.49; confidence intervals: 0.27-0.88; p = 0.02). Compared to conventional angioplasty, cutting balloon angio¬plasty prior to coronary beta-radiation with the Beta-CathTM System seems to improve the 6-month clinical outcome in patients with in-stent restenosis.
Resumo:
Objectives The objective of this article is to describe the development of an anatomically accurate simulator in order to aid the training of a perinatal team in the insertion and removal of a fetal endoscopic tracheal occlusion (FETO) balloon in the management of prenatally diagnosed congenital diaphragmatic hernia. Methods An experienced perinatal team collaborated with a medical sculptor to design a fetal model for the FETO procedure. Measurements derived from 28-week fetal magnetic resonance imaging were used in the development of an anatomically precise simulated airway within a silicone rubber preterm fetal model. Clinician feedback was then used to guide multiple iterations of the model with serial improvements in the anatomic accuracy of the simulator airway. Results An appropriately sized preterm fetal mannequin with a high-fidelity airway was developed. The team used this model to develop surgical skills with balloon insertion, and removal, and to prepare the team for an integrated response to unanticipated delivery with the FETO balloon still in situ. Conclusions This fetal mannequin aided in the ability of a fetal therapy unit to offer the FETO procedure at their center for the first time. This model may be of benefit to other perinatal centers planning to offer this procedure.
Resumo:
OBJECTIVES: This study sought to investigate whether self-expanding stents are more effective than balloon-expandable stents for reducing stent malapposition at 3 days after implantation in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention. BACKGROUND: Acute myocardial infarction is associated with vasoconstriction and large thrombus burden. Resolution of vasoconstriction and thrombus load during the first hours to days after primary percutaneous coronary intervention may lead to stent undersizing and malapposition, which may subsequently lead to stent thrombosis or restenosis. In addition, aggressive stent deployment may cause distal embolization. METHODS: Eighty patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention were randomized to receive a self-expanding stent (STENTYS, STENTYS SA, Paris, France) (n = 43) or a balloon-expandable stent (VISION, Abbott Vascular, Santa Clara, California; or Driver, Medtronic, Minneapolis, Minnesota) (n = 37) at 9 European centers. The primary endpoint was the proportion of stent strut malapposition at 3 days after implantation measured by optical coherence tomography. Secondary endpoints included major adverse cardiac events (cardiac death, recurrent myocardial infarction, emergent bypass surgery, or clinically driven target lesion revascularization). RESULTS: At 3 days after implantation, on a per-strut basis, a lower rate of malapposed stent struts was observed by optical coherence tomography in the self-expanding stent group than in the balloon-expandable group (0.58% vs. 5.46%, p < 0.001). On a per-patient basis, none of the patients in the self-expanding stent group versus 28% in the balloon-expandable group presented ≥5% malapposed struts (p < 0.001). At 6 months, major adverse cardiac events were 2.3% versus 0% in the self-expanding and balloon-expandable groups, respectively (p = NS). CONCLUSIONS: Strut malapposition at 3 days is significantly lower in ST-segment elevation myocardial infarction patients allocated to self-expanding stents when than in those allocated to balloon-expandable stents. The impact of this difference on clinical outcome and the risk of late stent thrombosis need to be evaluated further. (Randomized Comparison Between the STENTYS Self-expanding Coronary Stent and a Balloon-expandable Stent in Acute Myocardial Infarction [APPOSITION II]; NCT01008085).
Resumo:
The PulseCath iVAC 3L? left ventricular assist device is an option to treat transitory left heart failure or dysfunction post-cardiac surgery. Assisted blood flow should reach up to 3 l/min. In the present in vitro model exact pump flow, depending on various frequencies and afterload was examined. Optimal flow was achieved with inflation/deflation frequencies of about 70-80/min. The maximal flow rate was achieved at about 2.5 l/min with a minimal afterload of 22 mmHg. Handling of the device was easy due to the connection to a standard intra-aortic balloon pump console. With increasing afterload (up to a simulated mean systemic pressure of 66 mmHg) flow rate and cardiac support are in some extent limited.
Resumo:
Acute cardiovascular dysfunction occurs perioperatively in more than 20% of cardiosurgical patients, yet current acute heart failure (HF) classification is not applicable to this period. Indicators of major perioperative risk include unstable coronary syndromes, decompensated HF, significant arrhythmias and valvular disease. Clinical risk factors include history of heart disease, compensated HF, cerebrovascular disease, presence of diabetes mellitus, renal insufficiency and high-risk surgery. EuroSCORE reliably predicts perioperative cardiovascular alteration in patients aged less than 80 years. Preoperative B-type natriuretic peptide level is an additional risk stratification factor. Aggressively preserving heart function during cardiosurgery is a major goal. Volatile anaesthetics and levosimendan seem to be promising cardioprotective agents, but large trials are still needed to assess the best cardioprotective agent(s) and optimal protocol(s). The aim of monitoring is early detection and assessment of mechanisms of perioperative cardiovascular dysfunction. Ideally, volume status should be assessed by 'dynamic' measurement of haemodynamic parameters. Assess heart function first by echocardiography, then using a pulmonary artery catheter (especially in right heart dysfunction). If volaemia and heart function are in the normal range, cardiovascular dysfunction is very likely related to vascular dysfunction. In treating myocardial dysfunction, consider the following options, either alone or in combination: low-to-moderate doses of dobutamine and epinephrine, milrinone or levosimendan. In vasoplegia-induced hypotension, use norepinephrine to maintain adequate perfusion pressure. Exclude hypovolaemia in patients under vasopressors, through repeated volume assessments. Optimal perioperative use of inotropes/vasopressors in cardiosurgery remains controversial, and further large multinational studies are needed. Cardiosurgical perioperative classification of cardiac impairment should be based on time of occurrence (precardiotomy, failure to wean, postcardiotomy) and haemodynamic severity of the patient's condition (crash and burn, deteriorating fast, stable but inotrope dependent). In heart dysfunction with suspected coronary hypoperfusion, an intra-aortic balloon pump is highly recommended. A ventricular assist device should be considered before end organ dysfunction becomes evident. Extra-corporeal membrane oxygenation is an elegant solution as a bridge to recovery and/or decision making. This paper offers practical recommendations for management of perioperative HF in cardiosurgery based on European experts' opinion. It also emphasizes the need for large surveys and studies to assess the optimal way to manage perioperative HF in cardiac surgery.
Resumo:
GOAL: To evaluate the impact of the Ross operation, recently (1997) introduced in our unit, for the treatment of patients with congenital aortic valve stenosis. METHODS: The period from January 1997 to December 2000 was compared with the previous 5 years (1992-96). Thirty-seven children (< 16 yrs) and 49 young adults (16-50 yrs) with congenital aortic valve stenosis underwent one of these treatments: percutaneous balloon dilatation (PBD), aortic valve commissurotomy, aortic valve replacement and the Ross operation. The Ross operation was performed in 16 patients, mean age 24.5 yrs (range 9-46 yrs) with a bicuspid stenotic aortic valve, 7/10 adults with calcifications, 2/10 adults with previous aortic valve commissurotomy, 4/6 children with aortic regurgitation following PBD, and 1/6 children who had had a previous aortic valve replacement with a prosthetic valve and aortic root enlargement. RESULTS: PBD was followed by death in two neonates (fibroelastosis); all other children survived PBD. Although there were no deaths, PBD in adults was recently abandoned, owing to unfavourable results. Aortic valve commissurotomy showed good results in children (no deaths). Aortic valve replacement, although associated with good results (no deaths), has been recently abandoned in children in favour of the Ross operation. Over a mean follow-up of 16 months (2-40 months) all patients are asymptomatic following Ross operation, with no echocardiographic evidence of aortic valve regurgitation in 10/16 patients and with trivial regurgitation in 6/16 patients. CONCLUSIONS: The approach now for children and young adults with congenital aortic valve stenosis should be as follows: (1) PBD is the first choice in neonates and infants; (2) Aortic valve commissurotomy is the first choice for children, neonates and infants after failed PBD; (3) The Ross operation is increasingly used in children after failed PBD and in young adults, even with a calcified aortic valve.
Resumo:
Purpose: To evaluate the safety-efficacy of Gamma Knife surgery (GKS) as a second treatment for classical trigeminal neuralgia (CTN), and the influence of prior microvascular decompression (MVD). Methods: Between July 1992 and November 2010, 737 patients have been operated with GKRS for ITN and prospectively evaluated in Timone University Hospital in Marseille, France. Among these, 54 patients had a previous history of MVD. Radiosurgery using a Gamma Knife (model B or C or Perfexion) was performed on the basis of on both MR and CT targeting. A single 4 mm isocenter was positioned in the cisternal portion of the trigeminal nerve at a median distance of 7.6 mm (range 3.9-11.9) anteriorly to the emergence of the nerve (retrogasserian target). A median maximum dose of 85 Gy (range 70-90) was delivered. Here, the 45 patients with previous MVD and a follow-up longer than one year are evaluated (the patients with megadolichobasilar artery compression and multiple sclerosis were excluded). Results: The median age in this series was 56.75 years (range 28.09-82.39). The median follow-up period was 39.48 months (range 14.10-144.65). All the patients had a past history of surgery, with at least one previous failed MVD, but also radiofrequency lesion (RFL) in 16 patients (35.6%), balloon microcompression in 7 (15.6%) and glycerol rhizotomy in 1 (2.2%). Thirty-five patients (77.8%) were initially pain free after GKS within a median time of 14 days (range 0, 180). Patients from this group had less probability of being pain free compared to our global population of essential trigeminal neuralgia without previous MVD history (p=0.010, hazard ratio of 0.64). Their probability of remaining pain free at 3, 5, 7 and 10 years was 66.5%, 59.1%, 59.1% and 44.3%, respectively. Twelve patients (34.3%) initially pain free experienced a recurrence with a median delay of 31.21 months (range 3.40-89.93). The hypoesthesia actuarial rate at 1 year was 9.1% and remained stable till 12 years with a median delay of onset of 8 months (range 8-8). Conclusions: Retrogasserian GKS proofed to be safe and effective on the long-term basis even after failed previous MVD. Even if the initial result of pain free was only 77.8%, the toxicity was low with only 9.1% hypoesthesia. No patient reported a bothersome hypoesthesia. The probability of maintaining pain relief in the long-term was of 44.3% at 10 years.
Resumo:
BACKGROUND & AIMS: The study was designed to investigate and quantify nutritional support, and particularly enteral nutrition (EN), in critically ill patients with severe hemodynamic failure. METHODS: Prospective, descriptive study in a surgical intensive care unit (ICU) in a university teaching hospital: patients aged 67+/-13 yrs (mean+/-SD) admitted after cardiac surgery with extracorporeal circulation, staying 5 days in the ICU with acute cardiovascular failure. Severity of disease was assessed with SAPS II, and SOFA scores. Variables were energy delivery and balance, nutrition route, vasopressor doses, and infectious complications. Artificial feeding delivered according to ICU protocol. EN was considered from day 2-3. Energy target was set 25 kcal/kg/day to be reached stepwise over 5 days. RESULTS: Seventy out of 1114 consecutive patients were studied, aged 67+/-17 years, and staying 10+/-7 days in the ICU. Median SAPS II was 43. Nine patients died (13%). All patients had circulatory failure: 18 patients required intra-aortic balloon-pump support (IABP). Norepinephrine was required in 58 patients (83%). Forty patients required artificial nutrition. Energy delivery was very variable. There was no abdominal complication related to EN. As a mean, 1360+/-620 kcal/kg/day could be delivered enterally during the first 2 weeks, corresponding to 70+/-35% of energy target. Enteral nutrient delivery was negatively influenced by increasing dopamine and norepinephrine doses, but not by the use of IABP. CONCLUSION: EN is possible in the majority of patients with severe hemodynamic failure, but usually results in hypocaloric feeding. EN should be considered in patients with careful abdominal and energy monitoring.