137 resultados para BLOOD COLLECTION

em Université de Lausanne, Switzerland


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: As imatinib pharmacokinetics are highly variable, plasma levels differ largely between patients under the same dosage. Retrospective studies in chronic myeloid leukemia (CML) patients showed significant correlations between low levels and suboptimal response, as well as between high levels and poor tolerability. Monitoring of trough plasma levels, targeting 1000 μg/L and above, is thus increasingly advised. Our study was launched to assess prospectively the clinical usefulness of systematic imatinib TDM in CML patients. This preliminary analysis addresses the appropriateness of the dosage adjustment approach applied in this study, which targets the recommended trough level and allows an interval of 4-24 h after last drug intake for blood sampling. Methods: Blood samples from the first 15 patients undergoing 1st TDM were obtained 1.5-25 h after last dose. Imatinib plasma levels were measured by LC-MS/MS and the concentrations were extrapolated to trough based on a Bayesian approach using a population pharmacokinetic model. Trough levels were predicted to differ significantly from the target in 12 patients (10 <750 μg/L; 2 >1500 μg/L along with poor tolerance) and individual dose adjustments were proposed. 8 patients underwent a 2nd TDM cycle. Trough levels of 1st and 2nd TDM were compared, the sample drawn 1.5 h after last dose (during distribution phase) was excluded from the analysis. Results: Individual dose adjustments were applied in 6 patients. Observed concentrations extrapolated to trough ranged from 360 to 1832 μg/L (median 725; mean 810, CV 52%) on 1st TDM and from 720 to 1187 μg/L (median 950; mean 940, CV 18%) on 2nd TDM cycle. Conclusions: These preliminary results suggest that TDM of imatinib using a Bayesian interpretation is able to target the recommended trough level of 1000 μg/L and to reduce the considerable differences in trough level exposure between patients (with CV decreasing from 52% to 18%). While this may simplify blood collection in daily practice, as samples do not have to be drawn exactly at trough, the largest possible interval to last drug intake yet remains preferable to avoid sampling during distribution phase leading to biased extrapolation. This encourages the evaluation of the clinical benefit of a routine TDM intervention in CML patients, which the randomized Swiss I-COME trial aims to.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Copeptin (CP), a derivate from the antidiuretic hormone (ADH) precursor pre-pro-vasopressin, stochiometrically mirrors ADH secretion. CP is increasingly evaluated as a diagnostic and prognostic biomarker in different diseases. It is therefore important to recognize possible confounding factors when interpreting CP levels. In healthy regularly menstruating women, there is a small but measurable physiological variability of hormones involved in fluid regulation. ADH plasma levels have been found to be lowest at menstruation, increasing during the follicular phase with a peak at ovulation and a drop in the luteal phase. We investigated the variability of CP during the menstrual cycle (MC) and its correlation to MC hormones. Methods: In total, 15 healthy women with regular MC (from 26 to 33 days) were included in this study. Ovulation was confirmed by progesterone (prog) levels on day 21 of the MC before entering the study and during the study. Blood collection was performed on days 3, 5, 8-16, 18, 21, 24 and 27 of their MC. Serums were assayed for prog, estradiol (E2), LH, and CP. Mixed linear regression analysis for repeated measures was performed to study the changes of CP, prog, E2 and LH during the MC, and to test the correlation of CP with sex hormones during the MC. Results: Mean MC length in all subjects was 28.5±2.2 d. E2, prog, and LH exhibited characteristic changes during the MC (all P< 0.05). All cycles were ovulatory (peak prog 54±15 nmol/l). CP levels did not change significantly throughout the MC, and were not associated with changes in prog, E2 or LH-levels (all P=ns). Conclusion: CP levels remain stable during the MC and are not influenced by changes in sex hormones. This implicates that it is not necessary to consider MC phases when using CP as a biomarker in premenopausal women.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: As imatinib pharmacokinetics are highly variable, plasma levels differ largely between patients under the same dosage. Retrospective studies in chronic myeloid leukemia (CML) patients showed significant correlations between low levels and suboptimal response, and between high levels and poor tolerability. Monitoring of plasma levels is thus increasingly advised, targeting trough concentrations of 1000 μg/L and above. Objectives: Our study was launched to assess the clinical usefulness of systematic imatinib TDM in CML patients. The present preliminary evaluation questions the appropriateness of dosage adjustment following plasma level measurement to reach the recommended trough level, while allowing an interval of 4-24 h after last drug intake for blood sampling. Methods: Initial blood samples from the first 9 patients in the intervention arm were obtained 4-25 h after last dose. Trough levels in 7 patients were predicted to be significantly away from the target (6 <750 μg/L, and 1 >1500 μg/L with poor tolerance), based on a Bayesian approach using a population pharmacokinetic model. Individual dosage adjustments were taken up in 5 patients, who had a control measurement 1-4 weeks after dosage change. Predicted trough levels were confronted to anterior model-based extrapolations. Results: Before dosage adjustment, observed concentrations extrapolated at trough ranged from 359 to 1832 μg/L (median 710; mean 804, CV 53%) in the 9 patients. After dosage adjustment they were expected to target between 720 and 1090 μg/L (median 878; mean 872, CV 13%). Observed levels of the 5 recheck measurements extrapolated at trough actually ranged from 710 to 1069 μg/L (median 1015; mean 950, CV 16%) and had absolute differences of 21 to 241 μg/L to the model-based predictions (median 175; mean 157, CV 52%). Differences between observed and predicted trough levels were larger when intervals between last drug intake and sampling were very short (~4 h). Conclusion: These preliminary results suggest that TDM of imatinib using a Bayesian interpretation is able to bring trough levels closer to 1000 μg/L (with CV decreasing from 53% to 16%). While this may simplify blood collection in daily practice, as samples do not have to be drawn exactly at trough, the largest possible interval to last drug intake yet remains preferable. This encourages the evaluation of the clinical benefit of a routine TDM intervention in CML patients, which the randomized Swiss I-COME study aims to.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Blood doping (BD) is the use of Erythropoietic Stimulating Agents (ESAs) and/or transfusion to increase aerobic performance in athletes. Direct toxicologic techniques are insufficient to unmask sophisticated doping protocols. The Hematological module of the ABP (World Anti-Doping Agency), associates decision support technology and expert assessment to indirectly detect BD hematological effects. Methods: The ABP module is based on blood parameters, under strict pre-analytical and analytical rules for collection, storage and transport at 2-12°C, internal and external QC. Accuracy, reproducibility and interlaboratory harmonization fulfill forensic standard. Blood samples are collected in competition and out-ofcompetition. Primary parameters for longitudinal monitoring are: - hemoglobin (HGB); - reticulocyte percentage (RET); - OFF score, indicator of suppressed erythropoiesis, calculated as [HGB(g/L) * 60-√RET%]. Statistical calculation predicts individual expected limits by probabilistic inference. Secondary parameters are RBC, HCT, MCHC-MCH-MCV-RDW-IFR. ABP profiles flagged as atypical are review by experts in hematology, pharmacology, sports medicine or physiology, and classified as: - normal - suspect (to target) - likely due to BD - likely due to pathology. Results: Thousands of athletes worldwide are currently monitored. Since 2010, at least 35 athletes have been sanctioned and others are prosecuted on the sole basis of abnormal ABP, with a 240% increase of positivity to direct tests for ESA, thanks to improved targeting of suspicious athletes (WADA data). Specific doping scenarios have been identified by the Experts (Table and Figure). Figure. Typical HGB and RET profiles in two highly suspicious athletes. A. Sample 2: simultaneous increases in HGB and RET (likely ESA stimulation) in a male. B. Samples 3, 6 and 7: "OFF" picture, with high HGB and low RET in a female. Sample 10: normal HGB and increased RET (ESA or blood withdrawal). Conclusions: ABP is a powerful tool for indirect doping detection, based on the recognition of specific, unphysiological changes triggered by blood doping. The effect of factors of heterogeneity, such as sex and altitude, must also be considered. Schumacher YO, et al. Drug Test Anal 2012, 4:846-853. Sottas PE, et al. Clin Chem 2011, 57:969-976.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: Elevated plasma levels of the elastase alpha 1-proteinase inhibitor complex (E-alpha 1 PI) have been proposed as a marker of bacterial infection and neutrophil activation. Liberation of elastase from neutrophils after collection of blood may cause falsely elevated results. Collection methods have not been validated for critically ill neonates and children. We evaluated the influence of preanalytical methods on E-alpha 1 PI results including the recommended collection into EDTA tubes. DESIGN AND METHODS: First, we compared varying acceleration speeds and centrifugation times. Centrifugation at 1550 g for 3 min resulted in reliable preparation of leukocyte free plasma. Second, we evaluated all collection tubes under consideration for absorption of E-alpha 1 PI. Finally, 12 sets of samples from healthy adults and 42 sets obtained from critically ill neonates and children were distributed into the various sampling tubes. Samples were centrifuged within 15 min of collection and analyzed with a new turbidimetric assay adapted to routine laboratory analyzers. RESULTS: One of the two tubes containing a plasma-cell separation gel absorbed 22.1% of the E-alpha 1 PI content. In the remaining tubes without absorption of E-alpha 1 PI no differences were observed for samples from healthy adult patients. However, in samples from critically ill neonates or children, significantly higher results were obtained for plain Li-heparin tubes (mean = 183 micrograms/L), EDTA tubes (mean = 93 micrograms/L), and citrate tubes (mean = 88.5 micrograms/L) than for the Li-hep tube with cell-plasma separation gel and no absorption of E-alpha 1 PI (mean = 62.4 micrograms/L, p < 0.01). CONCLUSION: Contrary to healthy adults, E-alpha 1 PI results in plasma samples from critically ill neonates and children depend on the type of collection tube.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: A misleading blood tacrolimus concentration (BTC) value caused by the contamination of a central venous catheter previously used for tacrolimus administration is described. SUMMARY: A 59-year-old woman with severe chronic obstructive pulmonary disease successfully underwent double lung transplantation. In the intensive care unit, she received a continuous i.v. infusion of tacrolimus from days 1 to 5 after transplantation through the distal lumen of a polyurethane triple-lumen central venous catheter. The catheter lumen was flushed twice a day with 0.9% sodium chloride injection. The proximal lumen was used for blood sampling after being flushed; the first 10 mL of blood was discarded. BTCs determined in whole blood one, four, and five days after transplantation were within the therapeutic range of 5-15 ng/mL. On day five the patient was transferred to the thoracic surgery ward and was switched to oral tacrolimus 1.5 mg twice daily. The BTC on day 6 was unexpectedly high at 134.5 ng/mL. The patient's clinical status was normal, and no signs of tacrolimus toxicity were observed. On day 7, blood samples were drawn from a peripheral vein and simultaneously through the central venous catheter. Although the central venous catheter had not been exposed to tacrolimus during the preceding two days, it yielded blood with a BTC eight times higher than the BTC in blood from the peripheral vein (41.4 ng/mL versus 5.1 ng/mL). CONCLUSION: The collection of blood from a central venous catheter lumen that had been used for tacrolimus administration resulted in a BTC about eight times higher than what was measured in peripheral blood.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction:  With the setting up of the newly Athlete's Biological Passport antidoping programme, novel guidelines have been introduced to guarantee results beyond reproach. We investigated in this context, the effect of storage time on the variables commonly measured for the haematological passport. We also wanted to assess for these variables, the within and between analyzer variations. Methods:  Blood samples were obtained from top level male professional cyclists (27 samples for the first part of the study and 102 for the second part) taking part to major stage races. After collection, they were transported under refrigerated conditions (2 °C < T < 12 °C), delivered to the antidoping laboratory, analysed and then stored at approximately 4 °C to conduct analysis at different time points up to 72 h after delivery. A mixed-model procedure was used to determine the stability of the different variables. Results:  As expected haemoglobin concentration was not affected by storage and showed stability for at least 72 h. Under the conditions of our investigation, the reticulocytes percentage showed a much better stability than previous published data (> 48 h) and the technical comparison of the haematology analyzer demonstrated excellent results. Conclusion:  In conclusion, our data clearly demonstrate that as long as the World Anti-Doping Agency's guidelines are followed rigorously, all blood results reach the quality level required in the antidoping context.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The availability of stored red blood cells (RBCs) for transfusion remains an important aspect of the treatment of polytrauma, acute anemia or major bleedings. RBCs are prepared by blood banks from whole blood donations and stored in the cold in additive solutions for typically six weeks. These far from physiological storage conditions result in the so-called red cell storage lesion that is of importance both to blood bankers and to clinical practitioners. Here we review the current state of knowledge about the red cell storage lesion from a proteomic perspective. In particular, we describe the current models accounting for RBC aging and response to lethal stresses, review the published proteomic studies carried out to uncover the molecular basis of the RBC storage lesion, and conclude by suggesting a few possible proteomic studies that would provide further knowledge of the molecular alterations carried by RBCs stored in the cold for six weeks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hematocrit (Hct) is one of the most critical issues associated with the bioanalytical methods used for dried blood spot (DBS) sample analysis. Because Hct determines the viscosity of blood, it may affect the spreading of blood onto the filter paper. Hence, accurate quantitative data can only be obtained if the size of the paper filter extracted contains a fixed blood volume. We describe for the first time a microfluidic-based sampling procedure to enable accurate blood volume collection on commercially available DBS cards. The system allows the collection of a controlled volume of blood (e.g., 5 or 10 μL) within several seconds. Reproducibility of the sampling volume was examined in vivo on capillary blood by quantifying caffeine and paraxanthine on 5 different extracted DBS spots at two different time points and in vitro with a test compound, Mavoglurant, on 10 different spots at two Hct levels. Entire spots were extracted. In addition, the accuracy and precision (n = 3) data for the Mavoglurant quantitation in blood with Hct levels between 26% and 62% were evaluated. The interspot precision data were below 9.0%, which was equivalent to that of a manually spotted volume with a pipet. No Hct effect was observed in the quantitative results obtained for Hct levels from 26% to 62%. These data indicate that our microfluidic-based sampling procedure is accurate and precise and that the analysis of Mavoglurant is not affected by the Hct values. This provides a simple procedure for DBS sampling with a fixed volume of capillary blood, which could eliminate the recurrent Hct issue linked to DBS sample analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Dried blood spots (DBS) sampling has gained popularity in the bioanalytical community as an alternative to conventional plasma sampling, as it provides numerous benefits in terms of sample collection and logistics. The aim of this work was to show that these advantages can be coupled with a simple and cost-effective sample pretreatment, with subsequent rapid LC-MS/MS analysis for quantitation of 15 benzodiazepines, six metabolites and three Z-drugs. For this purpose, a simplified offline procedure was developed that consisted of letting a 5-µl DBS infuse directly into 100 µl of MeOH, in a conventional LC vial. RESULTS: The parameters related to the DBS pretreatment, such as extraction time or internal standard addition, were investigated and optimized, demonstrating that passive infusion in a regular LC vial was sufficient to quantitatively extract the analytes of interest. The method was validated according to international criteria in the therapeutic concentration ranges of the selected compounds. CONCLUSION: The presented strategy proved to be efficient for the rapid analysis of the selected drugs. Indeed, the offline sample preparation was reduced to a minimum, using a small amount of organic solvent and consumables, without affecting the accuracy of the method. Thus, this approach enables simple and rapid DBS analysis, even when using a non-DBS-dedicated autosampler, while lowering the costs and environmental impact.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Concerns about self-reports have led to calls for objective measures of blood alcohol concentration (BAC). The present study compared objective measures with self-reports. Methods: BAC from breath or blood samples were obtained from 272 randomly sampled injured patients who were admitted to a Swiss emergency department (ED). Self-reports were compared a) between those providing and refusing a BAC test, and b) to estimated peak BAC (EPBAC) values based on BACs using the Widmark formula. Results: Those providing BACs were significantly (P < 0.05) younger, more often male, and less often reported alcohol consumption before injury, but consumed higher quantities when drinking. Eighty-eight percent of those with BAC measures gave consistent reports (positive or negative). Significantly more patients reported consumption with negative BAC measures (N = 29) than vice versa (N = 3). Duration of consumption and times between injury and BAC measurement predicted EPBAC better than did the objective BAC measure. Conclusions: There is little evidence that patients who provide objective BAC measures deliberately conceal consumption. ED studies must rely on self-reports, eg, take the time period between injury and ED admission into account. Clearly, objective measures are of clinical relevance, eg, to provide optimal treatment in the ED. However, they may be less relevant to establishing effects in an epidemiologic sense, such as estimating risk relationships. In this respect, efforts to increase the validity and reliability of self-reports should be preferred over the collection of additional objective measures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this work was to combine the advantages of the dried blood spot (DBS) sampling process with the highly sensitive and selective negative-ion chemical ionization tandem mass spectrometry (NICI-MS-MS) to analyze for recent antidepressants including fluoxetine, norfluoxetine, reboxetine, and paroxetine from micro whole blood samples (i.e., 10 microL). Before analysis, DBS samples were punched out, and antidepressants were simultaneously extracted and derivatized in a single step by use of pentafluoropropionic acid anhydride and 0.02% triethylamine in butyl chloride for 30 min at 60 degrees C under ultrasonication. Derivatives were then separated on a gas chromatograph coupled with a triple-quadrupole mass spectrometer operating in negative selected reaction monitoring mode for a total run time of 5 min. To establish the validity of the method, trueness, precision, and selectivity were determined on the basis of the guidelines of the "Société Française des Sciences et des Techniques Pharmaceutiques" (SFSTP). The assay was found to be linear in the concentration ranges 1 to 500 ng mL(-1) for fluoxetine and norfluoxetine and 20 to 500 ng mL(-1) for reboxetine and paroxetine. Despite the small sampling volume, the limit of detection was estimated at 20 pg mL(-1) for all the analytes. The stability of DBS was also evaluated at -20 degrees C, 4 degrees C, 25 degrees C, and 40 degrees C for up to 30 days. Furthermore, the method was successfully applied to a pharmacokinetic investigation performed on a healthy volunteer after oral administration of a single 40-mg dose of fluoxetine. Thus, this validated DBS method combines an extractive-derivative single step with a fast and sensitive GC-NICI-MS-MS technique. Using microliter blood samples, this procedure offers a patient-friendly tool in many biomedical fields such as checking treatment adherence, therapeutic drug monitoring, toxicological analyses, or pharmacokinetic studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Some recent studies have characterized the stability of blood variables commonly measured for the Athlete Biological Passport. The aim of this study was to characterize the impact of different shipments conditions and the quality of the results returned by the haematological analyzer. Twenty-two healthy male subjects provided five EDTA tubes each. Four shipment conditions (24, 36, 48, 72 h) under refrigerated conditions were tested and compared to a set of samples left in the laboratory also under refrigerated conditions (group control). All measurements were conducted using two Sysmex XT-2000i analyzers. Haemoglobin concentration, reticulocytes percentage, and OFF-score numerical data were the same for samples analyzed just after collection and after a shipment under refrigerated conditions up to 72 h. Detailed information reported especially by the differential (DIFF) channel scatterplot of the Sysmex XT-2000i indicated that there were signs of blood deterioration, but were not of relevance for the variables used in the Athlete Biological Passport. As long as the cold chain is guaranteed, the time delay between the collection and the analyses of blood variables can be extended. Copyright© 2015 John Wiley & Sons, Ltd.