227 resultados para Autologous bone graft
em Université de Lausanne, Switzerland
A pedicled bone graft from the acromion: an anatomical investigation regarding surgical feasibility.
Resumo:
OBJECTIVE: To investigate the technical feasibility of harvesting a vascularized bone graft from the acromion pedicled on the acromial branch. BACKGROUND: Complex fractures of the proximal humerus may result in partial or total avascular necrosis of the head fragment. Treatment of avascular necrosis of the humeral head is dependent upon the stage of disease as well as the dimension and location of necrosis. In general, the outcome is poor and complete restoration of the shoulder function is rarely attained. Contrary to osteonecrosis of carpal bones (where vascularized bone grafts have been routinely carried out for decades), reports of analogous procedures at the humeral head are anecdotal. METHODS: Based on selective post-mortem computer-tomographic angiography of 5 and the dissection of 30 embalmed human cadaver shoulders, we describe the anatomy of the acromial branch of the thoracoacromial trunk. The main focus was the constancy of its anatomical course, its dimensions and potential use as a nutrient vessel for a pedicled bone graft from the acromion. RESULTS: The course of the acromial branch revealed a constant topographic relationship to anatomical landmarks. Its terminal branches reliably supplied the anterior part of the acromion. The vascularized bone graft could be sufficiently mobilized to allow tension-free transfer to the humeral head as well as to the lateral two-thirds of the clavicle. CONCLUSION: We demonstrated the feasibility of vascularized bone graft harvesting from the acromion. This technique could be a joint-preserving procedure for osteonecrosis of the humeral head or may assist in the revision of a clavicular pseudoarthrosis.
Resumo:
We analyzed the initial adhesion and biofilm formation of Staphylococcus aureus (ATCC 29213) and S. epidermidis RP62A (ATCC 35984) on various bone grafts and bone graft substitutes under standardized in vitro conditions. In parallel, microcalorimetry was evaluated as a real-time microbiological assay in the investigation of biofilm formation and material science research. The materials beta-tricalcium phosphate (beta-TCP), processed human spongiosa (Tutoplast) and poly(methyl methacrylate) (PMMA) were investigated and compared with polyethylene (PE). Bacterial counts (log(10) cfu per sample) were highest on beta-TCP (S. aureus 7.67 +/- 0.17; S. epidermidis 8.14 +/- 0.05) while bacterial density (log(10) cfu per surface) was highest on PMMA (S. aureus 6.12 +/- 0.2, S. epidermidis 7.65 +/- 0.13). Detection time for S. aureus biofilms was shorter for the porous materials (beta-TCP and processed human spongiosa, p < 0.001) compared to the smooth materials (PMMA and PE), with no differences between beta-TCP and processed human spongiosa (p > 0.05) or PMMA and PE (p > 0.05). In contrast, for S. epidermidis biofilms the detection time was different (p < 0.001) between all materials except between processed human spongiosa and PE (p > 0.05). The quantitative analysis by quantitative culture after washing and sonication of the material demonstrated the importance of monitoring factors like specific surface or porosity of the test materials. Isothermal microcalorimetry proved to be a suitable tool for an accurate, non-invasive and real-time microbiological assay, allowing the detection of bacterial biomass without removing the biofilm from the surface.
Resumo:
BACKGROUND: Bone graft substitute such as calcium sulfate are frequently used as carrier material for local antimicrobial therapy in orthopedic surgery. This study aimed to assess the systemic absorption and disposition of tobramycin in patients treated with a tobramycin-laden bone graft substitute (Osteoset® T). METHODS: Nine blood samples were taken from 12 patients over 10 days after Osteoset® T surgical implantation. Tobramycin concentration was measured by fluorescence polarization. Population pharmacokinetic analysis was performed using NONMEM to assess the average value and variability (CV) of pharmacokinetic parameters. Bioavailability (F) was assessed by equating clearance (CL) with creatinine clearance (Cockcroft CLCr). Based on the final model, simulations with various doses and renal function levels were performed. (ClinicalTrials.gov number, NCT01938417). RESULTS: The patients were 52 +/- 20 years old, their mean body weight was 73 +/- 17 kg and their mean CLCr was 119 +/- 55 mL/min. Either 10 g or 20 g Osteoset® T with 4% tobramycin sulfate was implanted in various sites. Concentration profiles remained low and consistent with absorption rate-limited first-order release, while showing important variability. With CL equated to CLCr, mean absorption rate constant (ka) was 0.06 h-1, F was 63% or 32% (CV 74%) for 10 and 20 g Osteoset® T respectively, and volume of distribution (V) was 16.6 L (CV 89%). Simulations predicted sustained high, potentially toxic concentrations with 10 g, 30 g and 50 g Osteoset® T for CLCr values below 10, 20 and 30 mL/min, respectively. CONCLUSIONS: Osteoset® T does not raise toxicity concerns in subjects without significant renal failure. The risk/benefit ratio might turn unfavorable in case of severe renal failure, even after standard dose implantation.
Resumo:
AIMS: Clinical trials suggest that intracoronary delivery of autologous bone marrow-derived cells (BMCs) 1-7 days post-acute myocardial infarction (AMI) may improve left ventricular (LV) function. Earlier time points have not been evaluated. We sought to determine the effect of intracoronary autologous BMC on LV function when delivered within 24 h of successful reperfusion therapy. METHODS AND RESULTS: A multi-centre phase II randomized, double-blind, and placebo-controlled trial. One hundred patients with anterior AMI and significant regional wall motion abnormality were randomized to receive either intracoronary infusion of BMC or placebo (1:1) within 24 h of successful primary percutaneous intervention (PPCI). The primary endpoint was the change in left ventricular ejection fraction (LVEF) between baseline and 1 year as determined by advanced cardiac imaging. At 1 year, although LVEF increased compared with baseline in both groups, the between-group difference favouring BMC was small (2.2%; 95% confidence interval, CI: -0.5 to 5.0; P = 0.10). However, there was a significantly greater myocardial salvage index in the BMC-treated group compared with placebo (0.1%; 95% CI: 0.0-0.20; P = 0.048). Major adverse events were rare in both treatment groups. CONCLUSION: The early infusion of intracoronary BMC following PPCI for patients with AMI and regional wall motion abnormality leads to a small non-significant improvement in LVEF when compared with placebo; however, it may play an important role in infarct remodelling and myocardial salvage. CLINICAL TRIAL REGISTRATION: Clinicaltrials.gov NCT00765453 and EudraCT 2007-002144-16.
Resumo:
Introduction: Nonoperative treatment of displaced midshaft clavicle fractures is associated with higher nonunion rate than previously reported. Moreover, its occurrence can compromise shoulder function. The aim of this study was to evaluate the outcome of surgical treatment of symptomatic clavicle midshaft delayed and nonunion. Methods: Between 1999 and 2008, 19 clavicle delayed unions and nonunions were treated by open reduction and reconstructive plate fixation with augmentation by autologous bone graft. Iliac bone graft was used in 15 atrophic cases, and graft from the callus was used in 4 hypertrophic nonunions. There were 14 men and 5 women, with an average age of 41 years (range, 19 to 59 years) at time of surgery. No patient had undergone a previous surgery and all complained of shoulder pain. Delayed unions and nonunions were defined as non-healing after 3 and 6 months respectively. The mean time to surgery was 8 months (range, 4 to 23 months). All patients were pre and postoperatively clinically evaluated and imaged with standard radiographs until complete healing. Results: After a mean time of 3 months (range, 2 to 7 months) all fractures were completely healed. All patients reported full range of motion at time of last follow-up. Nine patients (47%) reported slight shoulder pain but all returned to their previous professional activities after a mean time of 3 months (range, 1 to 8 months). We reported 12 (63%) minor complications. There were 6 (32%) plate-related discomforts which resolved after hardware removal, two (11%) scar numbness, two (11%) adhesive capsulitis with spontaneous complete recovery, and two (11%) AC-joint pain treated successfully with local corticosteroids injection. Conclusion: Surgical treatment of delayed unions and nonunions of midshaft clavicle fractures yields satisfactory results and a high union rate. However, 50% of the patients may still complain of slight residual shoulder pain.
Resumo:
BACKGROUND: Intracoronary injection of autologous bone marrow-derived mononucleated cells (BM-MNC) may improve LV function shortly after acute ST elevation myocardial infarction (STEMI), but little is known about the long-term durability of the treatment effect. METHODS: In a single-centre trial a total of 60 patients with acute anterior STEMI, successful reperfusion therapy and a left ventricular ejection fraction (LVEF) of <50% were screened for the study. 23 patients were actively treated with intracoronary infusion of BM-MNC within a median of 3 days. The open-label control group consisted of 19 patients who did not consent to undergo BM-MNC treatment but agreed to undergo regular clinical and echocardiographic follow-up for up to 5 years after AMI. RESULTS: Whereas at 4 months there was no significant difference between the increase in LVEF in the BM-MNC group and the control group (+7.0%, 95%CI 3.6; 10.4) vs. +3.9%, 95%CI -2.1; 10), the absolute increase at 5 years remained stable in the BM-MNC but not in the control group (+7.95%, 95%CI 3.5; 12.4 vs. -0.5%, 95%CI -5.4; 4.4; p for interaction between groups = 0.035). DISCUSSION: In this single-centre, open-labelled study, intracoronary administration of BM-MNC is feasible and safe in the short term. It is also associated with sustained improvement of left ventricular function in patients with acute myocardial infarction, encouraging phase III studies to examine the potential BM-MNC effect on clinical outcome.
Resumo:
BACKGROUND: Intracoronary administration of autologous bone marrow-derived mononuclear cells (BM-MNC) may improve remodeling of the left ventricle (LV) after acute myocardial infarction. The optimal time point of administration of BM-MNC is still uncertain and has rarely been addressed prospectively in randomized clinical trials. METHODS AND RESULTS: In a multicenter study, we randomized 200 patients with large, successfully reperfused ST-segment elevation myocardial infarction in a 1:1:1 pattern into an open-labeled control and 2 BM-MNC treatment groups. In the BM-MNC groups, cells were administered either early (ie, 5 to 7 days) or late (ie, 3 to 4 weeks) after acute myocardial infarction. Cardiac magnetic resonance imaging was performed at baseline and after 4 months. The primary end point was the change from baseline to 4 months in global LV ejection fraction between the 2 treatment groups and the control group. The absolute change in LV ejection fraction from baseline to 4 months was -0.4±8.8% (mean±SD; P=0.74 versus baseline) in the control group, 1.8±8.4% (P=0.12 versus baseline) in the early group, and 0.8±7.6% (P=0.45 versus baseline) in the late group. The treatment effect of BM-MNC as estimated by ANCOVA was 1.25 (95% confidence interval, -1.83 to 4.32; P=0.42) for the early therapy group and 0.55 (95% confidence interval, -2.61 to 3.71; P=0.73) for the late therapy group. CONCLUSIONS: Among patients with ST-segment elevation myocardial infarction and LV dysfunction after successful reperfusion, intracoronary infusion of BM-MNC at either 5 to 7 days or 3 to 4 weeks after acute myocardial infarction did not improve LV function at 4-month follow-up. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00355186.
Resumo:
Various compositions of synthetic calcium phosphates (CaP) have been proposed and their use has considerably increased over the past decades. Besides differences in physico-chemical properties, resorption and osseointegration, artificial CaP bone graft might differ in their resistance against biofilm formation. We investigated standardised cylinders of 5 different CaP bone grafts (cyclOS, chronOS (both β-TCP (tricalcium phosphate)), dicalcium phosphate (DCP), calcium-deficient hydroxyapatite (CDHA) and α-TCP). Various physico-chemical characterisations e.g., geometrical density, porosity, and specific surface area were investigated. Biofilm formation was carried out in tryptic soy broth (TSB) and human serum (SE) using Staphylococcus aureus (ATCC 29213) and S. epidermidis RP62A (ATCC 35984). The amount of biofilm was analysed by an established protocol using sonication and microcalorimetry. Physico-chemical characterisation showed marked differences concerning macro- and micropore size, specific surface area and porosity accessible to bacteria between the 5 scaffolds. Biofilm formation was found on all scaffolds and was comparable for α-TCP, chronOS, CDHA and DCP at corresponding time points when the scaffolds were incubated with the same germ and/or growth media, but much lower for cyclOS. This is peculiar because cyclOS had an intermediate porosity, mean pore size, specific surface area, and porosity accessible to bacteria. Our results suggest that biofilm formation is not influenced by a single physico-chemical parameter alone but is a multi-step process influenced by several factors in parallel. Transfer from in vitro data to clinical situations is difficult; thus, advocating the use of cyclOS scaffolds over the four other CaP bone grafts in clinical situations with a high risk of infection cannot be clearly supported based on our data.
Resumo:
The morbidity of bone graft harvesting from the iliac crest has been widely discussed in the literature. For some authors, it is considered to be low and for others relatively high. We report on a case of a fracture of the iliac wing after graft harvesting from the anterior iliac crest despite good surgical technique. This complication is well known and most of these fractures heal uneventfully if treated conservatively. However, if anatomical and technical considerations are respected, the patient could be spared this inconvenience. Based on a literature review, we discuss the procedure's potential complications and how to avoid them in an update.
Resumo:
Background: Bacteria form a biofilm on the surface of orthopaedic devices, causing persistent and infection. Little is known about biofilms formation on bone grafts and bone substitutes. We analyzed various representative materials regarding their propensity for biofilm formation caused by Staphylococcus aureus.Methods: As bone graft beta-tricalciumphosphate (b-TCP, CyclOsTM) and as bone substitute a tantalum metal mesh (trabecular metalTM) and PMMA (Pala-cosTM) were investigated. As test organism S. aureus (strain ATCC 29213) was used. Test materials were incubated with bacterial solution of 105 colony-forming units (cfu)/ml at 37°C for 24 h without shaking. After 24 h, the test materials were removed and washed 3 times in normal saline, followed by sonication in 50 ml Ringer solution at 40 kHz for 5 minutes. The resulting sonication fluid was plated in aliquots of 0.1 ml onto aerobe blood agar with 5% sheep blood and incubated at 37°C with 5% CO2 for 24 h. Then, bacterial counts were enumerated and expressed as cfu/ml. All experiments were performed in triplicate to calculate the mean ± standard deviation. The Wilcoxon test was used for statistical calculations.Results: The three investigated materials show a differing specific surface with b-TCB>trabecular metal>PMMA per mm2. S. aureus formed biofilm on all test materials as confirmed by quantitative culture after washing and sonication. The bacterial counts in sonication fluid (in cfu/ml) were higher in b-TCP (5.1 x 106 ± 0.6 x 106) and trabecular metal (3.7 x 106 ± 0.6 x 106) than in PMMA (3.9 x 104 ± 1.8 x 104), p<0.05.Conclusion: Our results demonstrate that about 100-times more bacteria adhere on b-TCP and trabecular metal than on PMMA, reflecting the larger surface of b-TCP and trabecuar metal compared to the one of PMMA. This in-vitro data indicates that bone grafts are susceptible to infection. Further studies are needed to evaluate efficient approaches to prevent and treat infections associated with bone grafts and substitutes, including modification of the surface or antibacterial coating.
Resumo:
BACKGROUND: Hepatosplenic T cell lymphoma (HSTL) is a rare but very aggressive peripheral T cell lymphoma whose initial silent clinical presentation unfortunately delays the diagnosis and worsens the prognosis of patient survival. Efforts should be aimed at early recognition and treatment. METHODS: We describe a case of a 62-year-old woman who presented at our clinic with a non-palpable purpuric eruption of the face. Investigations revealed thrombocytopenia with hepatosplenomegaly, which showed rapid progression together with accentuation of the purpura. Two months later, a bone marrow biopsy revealed the diagnosis of a HSTL. RESULTS: The patient received six cycles of CHOP chemotherapy (vincristine, cyclophosphamide, doxorubicin, methylprednisolone) followed by a well-tolerated autologous bone marrow graft. Normalization of the platelet count resulted in regression of the purpuric rash. CONCLUSION: To our knowledge, this is the first report of a facial thrombocytopenic purpura as the inaugural symptom of HSTL. It emphasizes the privileged position of the dermatologist for early recognition of potentially lethal HSTL.
Resumo:
Although autologous nerve graft is still the first choice strategy in nerve reconstruction, it has the severe disadvantage of the sacrifice of a functional nerve. Cell transplantation in a bioartificial conduit is an alternative strategy to improve nerve regeneration. Nerve fibrin conduits were seeded with various cell types: primary Schwann cells (SC), SC-like differentiated bone marrow-derived mesenchymal stem cells (dMSC), SC-like differentiated adipose-derived stem cells (dASC). Two further control groups were fibrin conduits without cells and autografts. Conduits were used to bridge a 1 cm rat sciatic nerve gap in a long term experiment (16 weeks). Functional and morphological properties of regenerated nerves were investigated. A reduction in muscle atrophy was observed in the autograft and in all cell-seeded groups, when compared with the empty fibrin conduits. SC showed significant improvement in axon myelination and average fiber diameter of the regenerated nerves. dASC were the most effective cell population in terms of improvement of axonal and fiber diameter, evoked potentials at the level of the gastrocnemius muscle and regeneration of motoneurons, similar to the autografts. Given these results and other advantages of adipose derived stem cells such as ease of harvest and relative abundance, dASC could be a clinically translatable route towards new methods to enhance peripheral nerve repair.
Resumo:
Experimental studies in nude mice with human colon-carcinoma grafts demonstrated the therapeutic efficiency of F(ab')2 fragments to carcinoembryonic antigen (CEA) labeled with a high dose of 131Iodine. A phase I/II study was designed to determine the maximum tolerated dose of 131I-labeled F(ab')2 fragments (131I-F(ab')2) from anti-CEA monoclonal antibody F6, its limiting organ toxicity and tumor uptake. Ten patients with non-resectable liver metastases from colorectal cancer (9 detected by CT scan and 1 by laparotomy) were treated with 131I-F(ab')2, doses ranging from 87 mCi to 300 mCi for the first 5 patients, with a constant 300-mCi dose for the last 5 patients. For all the patients, autologous bone marrow was harvested and stored before treatment. Circulating CEA ranged from 2 to 126 ng/ml. No severe adverse events were observed during or immediately following infusion of therapeutic doses. The 9 patients with radiologic evidence of liver metastases showed uptake of 131I-F(ab')2 in the metastases, as observed by single-photon-emission tomography. The only toxicity was hematologic, and no severe aplasia was observed when up to 250 mCi was infused. At the 300-mCi dose, 5 out of 6 patients presented grade-3 or -4 hematologic toxicity, with a nadir for neutrophils and thrombocytes ranging from 25 to 35 days after infusion. In these 5 cases, bone marrow was re-infused. No clinical complications were observed during aplasia. The tumor response could be evaluated in 9 out of 10 patients. One patient showed a partial response of one small liver metastasis (2 cm in diameter) and a stable evolution of the other metastases, 2 patients had stable disease, and 6 showed tumor progression at the time of evaluation (2 or 3 months after injection) by CT scan. This phase-I/II study demonstrated that a dose of 300 mCi of 131I-F(ab')2 from the anti-CEA Mab F6 is well tolerated with bone-marrow rescue, whereas a dose of 200 mCi can be infused without severe bone-marrow toxicity.
Resumo:
Abstract: Osteomyelitis is responsible for high treatment costs, long hospital stays, and results in substantial morbidity. Treatment with surgical debridement and antibiotic-impregnated Polymethylmetacrylate (PMMA) beads is the standard of care, providing high local but low serum antibiotic concentrations, thereby avoiding systemic toxicity. However, for several reasons, the beads require surgical removal. Alternative antibiotic delivery systems should improve the treatment of bone infection, actively encourage bone healing and require no additional surgery for removal. We investigated the activity of gentamicin-loaded bioabsorbable beads against different microorganisms (Staphylococcus epidermidis, S. aureus, Escherichia coli, Enterococcus faecalis, Candida albicans) commonly causing surgical site bone infection, by microcalorimetry. Calcium sulphate beads containing gentamicin were incubated in microcalorimetry ampoules containing different concentrations of the corresponding microorganism. Growth medium with each germ and unloaded beads was used as positive control, growth medium with loaded beads alone as negative control. Bacterial growth-related heat production at 37 °C was measured for 24 h. Cultures without gentamicin-loaded beads produced heat-flow peaks corresponding to the exponential growth of the corresponding microorganisms in nutrient-rich medium. In contrast, cultures with gentamicin-loaded beads completely suppressed heat production during 24 h, demonstrating their antibiotic activity. Gentamicin-loaded beads effectively inhibited growth of susceptible microorganisms, under the described in vitro conditions.