182 resultados para Assisted reproduction techniques
em Université de Lausanne, Switzerland
Resumo:
National and international registries are essential tools for establishing new standards and comparing success rates, but they do not take into account the total pregnancy/delivery rate per oocyte recovery. In Switzerland and Germany, because of legal constraints, a maximum of three two-pronuclear zygotes are allocated for transfer whereas all the supernumerary pronuclear zygotes are immediately cryopreserved, preventing selection of the transferred embryos. We report on a 10 years' experience (1993-2002) of our centre which performs transfers of unselected embryos and cryopreservation at the two-pronuclear zygote stage. As approximately 30% of all deliveries are from cryo cycles, it is essential to take into account the contribution of the cryo transfers, and we propose therefore to evaluate, as a measure of IVF performance, the cumulated delivery rate per oocyte pick-up. This delivery rate is broken down further into the cumulated singleton delivery rate (CUSIDERA) and the cumulated twin delivery rate (CUTWIDERA). The sum (S) of these two rates is a measure of efficacy while the ratio CUTWIDERA/S as a percentage is a measure of safety of IVF treatments. Using these new indexes, the average 10 year efficacy and safety of our IVF programme were 26 and 19%, respectively. Both CUSIDERA and CUTWIDERA can be calculated easily in any clinical situation and yield useful parameters for patient counselling and internal/external benchmarking purposes.
Resumo:
PURPOSE: Our purpose was to develop a well-defined medium for the in vitro maturation (IVM) of immature bovine cumulus-oocyte complexes (COC). METHODS: The COC were cultured in the presence of three protein supplementations: fetal bovine serum (FBS), bovine serum albumin, and Synthetic Serum Substitute. The embryos obtained after in vitro fertilization of IVM oocytes were cocultured with Vero cells and their development to the morula and blastocyst stages was studied. RESULTS: When FBS was absent from the IVM medium, a significantly lower fertilization rate was observed, followed by a decrease in the percentage of embryos reaching the blastocyst stage. When FBS was replaced by a defined protein supplementation, the best results were obtained with Synthetic Serum Substitute. CONCLUSIONS: Adequate protein supplementation of the IVM medium optimizes the fertilization rate and the development of bovine IVM oocytes. The implication of these results in the human field is discussed.
Resumo:
Respiratory muscle weakness may induce dyspnoea, secretion retention and respiratory failure. Assessing respiratory muscle strength is mandatory in neuromuscular diseases and in case of unexplained dyspnoea. A step by step approach is recommended, starting with simple volitional tests. Using spirometry, respiratory muscle weakness may be suspected on the basis of an abnormal flow-volume loop or a fall of supine vital capacity. When normal, maximal inspiratory and expiratory pressures against a near complete occlusion exclude significant muscle weakness, but low values are more difficult to interpret. Sniff nasal inspiratory pressure is a useful alternative because it is easy and it eliminates the problem of air leaks around the mouthpiece in patients with neuromuscular disorders. The strength available for coughing is easily assessed by measuring peak cough flow. In most cases, these simple non invasive tests are sufficient to confirm or to eliminate significant respiratory muscle weakness and help the timely introduction of ventilatory support or assisted cough techniques. In a minority of patients, a more complete evaluation is necessary using non volitional tests like cervical magnetic stimulation of phrenic nerves.
Resumo:
Oculo-auriculo-vertebral spectrum is a complex developmental disorder characterised mainly by anomalies of the ear, hemifacial microsomia, epibulbar dermoids and vertebral anomalies. The aetiology is largely unknown, and the epidemiological data are limited and inconsistent. We present the largest population-based epidemiological study to date, using data provided by the large network of congenital anomalies registries in Europe. The study population included infants diagnosed with oculo-auriculo-vertebral spectrum during the 1990-2009 period from 34 registries active in 16 European countries. Of the 355 infants diagnosed with oculo-auriculo-vertebral spectrum, there were 95.8% (340/355) live born, 0.8% (3/355) fetal deaths, 3.4% (12/355) terminations of pregnancy for fetal anomaly and 1.5% (5/340) neonatal deaths. In 18.9%, there was prenatal detection of anomaly/anomalies associated with oculo-auriculo-vertebral spectrum, 69.7% were diagnosed at birth, 3.9% in the first week of life and 6.1% within 1 year of life. Microtia (88.8%), hemifacial microsomia (49.0%) and ear tags (44.4%) were the most frequent anomalies, followed by atresia/stenosis of external auditory canal (25.1%), diverse vertebral (24.3%) and eye (24.3%) anomalies. There was a high rate (69.5%) of associated anomalies of other organs/systems. The most common were congenital heart defects present in 27.8% of patients. The prevalence of oculo-auriculo-vertebral spectrum, defined as microtia/ear anomalies and at least one major characteristic anomaly, was 3.8 per 100,000 births. Twinning, assisted reproductive techniques and maternal pre-pregnancy diabetes were confirmed as risk factors. The high rate of different associated anomalies points to the need of performing an early ultrasound screening in all infants born with this disorder.
Resumo:
Objective: This article presents a study of the change over time in the family interactions of couples who conceived through in-vitro fertilisation (IVF). Background: Observational methods are rarely used to study family interactions in families who used assisted reproductive techniques, but these methods are crucial for taking account of the communication that occurs in interactions with infants. Methods: Thirty-one couples expecting their first child were seen during the fifth month of pregnancy and when the child was nine months old. Family interactions were recorded in pre- and postnatal versions of the Lausanne Trilogue Play situation. Measures of marital satisfaction and parent-to-foetus/baby attachment or 'bonding' were also used to assess family relational dynamics. Results: Results showed that family alliance, marital satisfaction and parental attachment scores in the IVF sample were all similar to or higher than those in the reference sample during pregnancy. However, at nine months postnatally, the family alliance scores were lower. While marital satisfaction decreased over the period and parent-baby attachment increased, the family alliance scores were unstable, as no association was observed between the pre- and postnatal scores. In addition, neither prenatal marital satisfaction nor parent-foetus attachment predicted the postnatal family alliance. Conclusion: The change in the family alliance over the transition to parenthood appears to be specific to our IVF sample. Given that postnatal family functioning could not be predicted by prenatal family functioning, our observational data underline the importance of offering postnatal support to these families.
Resumo:
Malposition of the acetabular component during hip arthroplasty increases the occurrence of impingement, reduces range of motion, and increases the risk of dislocation and long-term wear. To prevent malpositioned hip implants, an increasing number of computer-assisted orthopaedic systems have been described, but their accuracy is not well established. The purpose of this study was to determine the reproducibility and accuracy of conventional versus computer-assisted techniques for positioning the acetabular component in total hip arthroplasty. Using a lateral approach, 150 cups were placed by 10 surgeons in 10 identical plastic pelvis models (freehand, with a mechanical guide, using computer assistance). Conditions for cup implantations were made to mimic the operating room situation. Preoperative planning was done from a computed tomography scan. The accuracy of cup abduction and anteversion was assessed with an electromagnetic system. Freehand placement revealed a mean accuracy of cup anteversion and abduction of 10 degrees and 3.5 degrees, respectively (maximum error, 35 degrees). With the cup positioner, these angles measured 8 degrees and 4 degrees (maximum error, 29.8 degrees), respectively, and using computer assistance, 1.5 degrees and 2.5 degrees degrees (maximum error, 8 degrees), respectively. Computer-assisted cup placement was an accurate and reproducible technique for total hip arthroplasty. It was more accurate than traditional methods of cup positioning.
Resumo:
L'émergence des nouvelles technologies de la reproduction (NTR) est allée de pair avec un certain nombre de discours. Un discours promettant d'une part une extension de la palette de choix reproductifs des individus, une extension de leur liberté et de leur autonomie reproductives, dont la forme la plus extrême peut se traduire par la formule : un enfant quand je veux et comme je veux. D'autre part, un discours annonçant une série de « catastrophes » à venir, telles que l'effondrement de l'institution de la famille et la modification de l'espèce humaine. En d'autres termes, une tension entre promesses et catastrophes qui place les sociétés contemporaines face à de nombreux défis sociaux, politiques et éthiques, notamment quant à la question de la régulation de la PMA (procréation médicalement assistée) : qui peut y avoir accès ? Quelles techniques doit-on autoriser ? Ou au contraire limiter ? Tant de questions auxquelles aucune réponse simple et évidente n'existe. La diversité des réponses législatives quant à ces questions illustre cette complexité. L'éthique peut, ici, jouer un rôle fondamental. Sans toutefois prétendre donner des réponses toutes faites et facilement applicables, elle offre un espace de réflexion, le privilège de prendre une certaine distance face à des enjeux contemporains. C'est dans cette perspective que nous avons ancré ce travail de recherche en questionnant les enjeux éthiques de la PMA à partir d'une perspective de justice. Toutefois, au sein des études en bioéthique, majoritairement issues de la tradition libérale, la tension énoncée précédemment mène la bioéthique à justifier un certain nombre d'inégalités plutôt que de veiller à les dépasser. Ainsi, une évaluation de la pratique de la PMA à partir d'une perspective de la justice, exige, au préalable, une réévaluation du concept même de justice. Ce faisant, par une articulation entre l'éthique du care de Joan Tronto et l'approche des capabilités de Martha Nussbaum qui placent la vulnérabilité au coeur de la personne, nous avons proposé une conception de la justice fondée sur une anthropologie de la vulnérabilité. Cette conception nous permet d'identifier, dans le cadre de la pratique de la PMA en Suisse et en partant de la loi sur la procréation assistée (LPMA), les constructions normatives qui mènent à la non-reconnaissance et, ce faisant, à la mise à l'écart, de certaines formes de vulnérabilité : une vulnérabilité générique et une vulnérabilité socio-économique. Traitant la question de la vulnérabilité générique principalement, nos analyses ont une incidence sur les conceptions de la famille, du bien de l'enfant, de la femme et de la nature, telles qu'elles sont actuellement véhiculées par une conception naturalisée de la PMA. Répondre aux vulnérabilités identifiées, en veillant à leur donner une place, signifie alors déplacer ces conceptions naturalisées, afin que les vulnérabilités soient intégrées aux pratiques sociales et que les exigences de justice soient ainsi remplies. - The emergence of assisted reproductive technologies (ART) came along with several discourses. On the one hand a discourse promising an extension of the individuals' reproductive choices, their procreative liberty and autonomy. On the other hand a discourse announced a series of disasters to come such as the collapse of the family institution and the modification of human kind. In other words, a growing tension appears between promises and disasters and contemporary societies are facing inevitable social, political and ethical challenges, in particular with regard to the issue of ART regulation: who has access? What procedures should be authorized? Which ones should be limited? These complex questions have no simple or obvious answers. The variety of legislative responses to these questions highlights complexity. Ethics can play a fundamental role, and without claiming to give simple answers, also offer a space for reflection as well as the privilege to distance itself with regard to contemporary issues. It is in this perspective that this study questions the ethical considerations of ART in a perspective of justice. However, in previous studies in bioethics mainly following a liberal tradition, previously mentioned tension has lead bioethics to justify some inequalities instead of trying to overcome them. As a consequence, evaluating practices of ART from a perspective of justice requires to first reevaluate the concept of justice itself. In doing so we offer a conception of justice founded on the anthropology of vulnerability. This conception draws on an articulation of the ethic of care of Joan Tronto and the capability approach of Martha Nussbaum, which places vulnerability at the center of the person. This conception allows us to identify, within the framework of ARTS in Switzerland and starting with the laws of medically assisted procreation (LPMA), some normative constructions. These constructions lead to the non-recognition and the disregard of some forms of vulnerability: a generic vulnerability as well as socio-economic counterpart. Focusing mainly on the issue of generic vulnerability, our analysis has implications for the conceptions of family, the best interests of the child, woman, and nature in the way they are defined in a naturalized conception of ART. Responding to such failures by taking into account these vulnerabilities thus means to move these conceptions in order for vulnerabilities to be integrated in social practices and requirements for justice to be fulfilled.
Resumo:
Introduction: In order to improve safety of pedicle screw placement several techniques have been developed. More recently robotically assisted pedicle insertion has been introduced aiming at increasing accuracy. The aim of this study was to compare this new technique with the two main pedicle insertion techniques in our unit namely fluoroscopically assisted vs EMG aided insertion. Material and methods: A total of 382 screws (78 thoracic,304 lumbar) were introduced in 64 patients (m/f = 1.37, equally distributed between insertion technique groups) by a single experienced spinal surgeon. From those, 64 (10 thoracic, 54 lumbar) were introduced in 11 patients using a miniature robotic device based on pre operative CT images under fluoroscopic control. 142 (4 thoracic, 138 lumbar) screws were introduced using lateral fluoroscopy in 27 patients while 176 (64 thoracic, 112 lumbar) screws in 26 patients were inserted using both fluoroscopy and EMG monitoring. There was no difference in the distribution of scoliotic spines between the 3 groups (n = 13). Screw position was assessed by an independent observer on CTs in axial, sagittal and coronal planes using the Rampersaud A to D classification. Data of lumbar and thoracic screws were processed separately as well as data obtained from axial, sagittal and coronal CT planes. Results: Intra- and interobserver reliability of the Rampersaud classification was moderate, (0.35 and 0.45 respectively) being the least good on axial plane. The total number of misplaced screws (C&D grades) was generally low (12 thoracic and 12 lumbar screws). Misplacement rates were same in straight and scoliotic spines. The only difference in misplacement rates was observed on axial and coronal images in the EMG assisted thoracic screw group with a higher proportion of C or D grades (p <0.05) in that group. Recorded compound muscle action potentials (CMAP) values of the inserted screws were 30.4 mA for the robot and 24.9mA for the freehand technique with a CI of 3.8 of the mean difference of 5.5 mA. Discussion: Robotic placement did improve the placement of thoracic screws but not that of lumbar screws possibly because our misplacement rates in general near that of published navigation series. Robotically assisted spine surgery might therefore enhance the safety of screw placement in particular in training settings were different users at various stages of their learning curve are involved in pedicle instrumentation.
Resumo:
OBJECTIVE: The optimal coronary MR angiography sequence has yet to be determined. We sought to quantitatively and qualitatively compare four coronary MR angiography sequences. SUBJECTS AND METHODS. Free-breathing coronary MR angiography was performed in 12 patients using four imaging sequences (turbo field-echo, fast spin-echo, balanced fast field-echo, and spiral turbo field-echo). Quantitative comparisons, including signal-to-noise ratio, contrast-to-noise ratio, vessel diameter, and vessel sharpness, were performed using a semiautomated analysis tool. Accuracy for detection of hemodynamically significant disease (> 50%) was assessed in comparison with radiographic coronary angiography. RESULTS: Signal-to-noise and contrast-to-noise ratios were markedly increased using the spiral (25.7 +/- 5.7 and 15.2 +/- 3.9) and balanced fast field-echo (23.5 +/- 11.7 and 14.4 +/- 8.1) sequences compared with the turbo field-echo (12.5 +/- 2.7 and 8.3 +/- 2.6) sequence (p < 0.05). Vessel diameter was smaller with the spiral sequence (2.6 +/- 0.5 mm) than with the other techniques (turbo field-echo, 3.0 +/- 0.5 mm, p = 0.6; balanced fast field-echo, 3.1 +/- 0.5 mm, p < 0.01; fast spin-echo, 3.1 +/- 0.5 mm, p < 0.01). Vessel sharpness was highest with the balanced fast field-echo sequence (61.6% +/- 8.5% compared with turbo field-echo, 44.0% +/- 6.6%; spiral, 44.7% +/- 6.5%; fast spin-echo, 18.4% +/- 6.7%; p < 0.001). The overall accuracies of the sequences were similar (range, 74% for turbo field-echo, 79% for spiral). Scanning time for the fast spin-echo sequences was longest (10.5 +/- 0.6 min), and for the spiral acquisitions was shortest (5.2 +/- 0.3 min). CONCLUSION: Advantages in signal-to-noise and contrast-to-noise ratios, vessel sharpness, and the qualitative results appear to favor spiral and balanced fast field-echo coronary MR angiography sequences, although subjective accuracy for the detection of coronary artery disease was similar to that of other sequences.
Resumo:
Stress radiographs have been recommended in order to obtain a better objective quantification of abnormal compartment knee motion. This tool has showed to be superior in quantifying a posterior cruciate ligament (PCL) lesion compared to clinical or arthrometer evaluation. Different radiographic techniques have been described in literature to quantify posterior pathological laxity. In this study we evaluated the total amount of posterior displacement (PTD) and side to side difference (SSD), before and after surgical reconstruction of PCL or PCL and posterolateral complex (PLC), using two different stress radiography techniques (Telos stress and kneeling view). Twenty patients were included in this study. We found a statistical significant difference about both total PTD and SSD among the two techniques preoperatively and at follow-up, with greatest values occurring using the kneeling view. Although stress radiographies has been introduced to allow an objective quantification of laxity in ligamentous injured knee, we believe that further studies on a large numbers of subjects are required to define the relationship between PTD values, measured with stress knee radiography, particularly using kneeling view, and ligamentous knee injury, in order to obtain a real useful tool in the decision making process, as well as to evaluate the outcome after ligamentous surgery.
Resumo:
Although gravity drainage has been the standard technique for cardiopulmonary bypass (CPB), the development of min imally invasive techniques for cardiac surgery has renewed interest in using vacuum assisted venous drainage (VAVD) Dideco (Mirandola, Italy) has modified the D903 Avant oxygenator to apply a vacuum to its venous reservoir. The impact of VAVD on blood damage with this device is analyzed. Six calves (mean body weight, 71.3 +/- 4.1 kg) were con nected to CPB by jugular venous and carotid arterial cannu lation, with a flow rate of 4-4.51 L/min for 6 h. They were assigned to gravity drainage (standard D903 Avant oxygen ator, n = 3) or VAVD (modified D903 Avant oxygenator, n = 3). The animals were allowed to survive for 7 days. A standard battery of blood samples was taken before bypass, throughout bypass, and 24 h, 48 h, and 7 days after bypass. Analysis of variance was used for repeated measurements. Thrombocyte and white blood cell counts, corrected by hematocrit and normalized by prebypass values, were not significantly different between groups throughout all study periods. The same holds true for hemolytic parameters (lactate dehydrogenase [LDH] and plasma hemoglobin). Both peaked at 24 hr in the standard and VAVD groups: LDH, 2,845 +/- 974 IU/L vs. 2,537 +/- 476 IU/L (p = 0.65), respectively; and plasma hemoglobin, 115 +/- 31 mg/L vs. 89 +/- 455 mg/L (p = 0.45), respectively. In this experimental setup with prolonged perfusion time, VAVD does not increase trauma to blood cells in comparison with standard gravity drainage.
Resumo:
Electrotransfer and iontophoresis are being developed as innovative non-viral gene delivery systems for the treatment of eye diseases. These two techniques rely on the use of electric current to allow for higher transfection yield of various ocular cell types in vivo. Short pulses of relatively high-intensity electric fields are used for electrotransfer delivery, whereas the iontophoresis technique is based on the application of low voltage electric current. The basic principles of these techniques and their potential therapeutic application for diseases of the anterior and posterior segments of the eye are reviewed. Iontophoresis has been found most efficient for the delivery of small nucleic acid fragments such as antisense oligonucleotides, siRNA, or ribozymes. Electrotransfer, on the other hand, is being developed for the delivery of oligonucleotides or custom designed plasmids. The wide range of strategies already validated and the potential for targeting specific types of cells confirm the promising early observations made using electrotransfer and iontophoresis. These two nonviral delivery systems are safe and can be used efficiently for targeted gene delivery to ocular tissues in vivo. At the present, their application for the treatment of ocular human diseases is nearing its final stages of adaptation and practical implementation at the bedside.
Resumo:
Until recently, matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) techniques for the identification of microorganisms remained confined to research laboratories. In the last 2 years, the availability of relatively simple to use MALDI-TOF MS devices, which can be utilized in clinical microbiology laboratories, has changed the laboratory workflows for the identification of pathogens. Recently, the first prospective studies regarding the performance in routine bacterial identification showed that MALDI-TOF MS is a fast, reliable and cost-effective technique that has the potential to replace and/or complement conventional phenotypic identification for most bacterial strains isolated in clinical microbiology laboratories. For routine bacterial isolates, correct identification by MALDI-TOF MS at the species level was obtained in 84.1-93.6% of instances. In one of these studies, a protein extraction step clearly improved the overall valid identification yield, from 70.3% to 93.2%. This review focuses on the current state of use of MALDI-TOF MS for the identification of routine bacterial isolates and on the main difficulties that may lead to erroneous or doubtful identifications.