87 resultados para Assessment in Mathematics
em Université de Lausanne, Switzerland
Resumo:
Currently, the most widely used criteria for assessing response to therapy in high-grade gliomas are based on two-dimensional tumor measurements on computed tomography (CT) or magnetic resonance imaging (MRI), in conjunction with clinical assessment and corticosteroid dose (the Macdonald Criteria). It is increasingly apparent that there are significant limitations to these criteria, which only address the contrast-enhancing component of the tumor. For example, chemoradiotherapy for newly diagnosed glioblastomas results in transient increase in tumor enhancement (pseudoprogression) in 20% to 30% of patients, which is difficult to differentiate from true tumor progression. Antiangiogenic agents produce high radiographic response rates, as defined by a rapid decrease in contrast enhancement on CT/MRI that occurs within days of initiation of treatment and that is partly a result of reduced vascular permeability to contrast agents rather than a true antitumor effect. In addition, a subset of patients treated with antiangiogenic agents develop tumor recurrence characterized by an increase in the nonenhancing component depicted on T2-weighted/fluid-attenuated inversion recovery sequences. The recognition that contrast enhancement is nonspecific and may not always be a true surrogate of tumor response and the need to account for the nonenhancing component of the tumor mandate that new criteria be developed and validated to permit accurate assessment of the efficacy of novel therapies. The Response Assessment in Neuro-Oncology Working Group is an international effort to develop new standardized response criteria for clinical trials in brain tumors. In this proposal, we present the recommendations for updated response criteria for high-grade gliomas.
Resumo:
This study describes the validation of a new wearable system for assessment of 3D spatial parameters of gait. The new method is based on the detection of temporal parameters, coupled to optimized fusion and de-drifted integration of inertial signals. Composed of two wirelesses inertial modules attached on feet, the system provides stride length, stride velocity, foot clearance, and turning angle parameters at each gait cycle, based on the computation of 3D foot kinematics. Accuracy and precision of the proposed system were compared to an optical motion capture system as reference. Its repeatability across measurements (test-retest reliability) was also evaluated. Measurements were performed in 10 young (mean age 26.1±2.8 years) and 10 elderly volunteers (mean age 71.6±4.6 years) who were asked to perform U-shaped and 8-shaped walking trials, and then a 6-min walking test (6MWT). A total of 974 gait cycles were used to compare gait parameters with the reference system. Mean accuracy±precision was 1.5±6.8cm for stride length, 1.4±5.6cm/s for stride velocity, 1.9±2.0cm for foot clearance, and 1.6±6.1° for turning angle. Difference in gait performance was observed between young and elderly volunteers during the 6MWT particularly in foot clearance. The proposed method allows to analyze various aspects of gait, including turns, gait initiation and termination, or inter-cycle variability. The system is lightweight, easy to wear and use, and suitable for clinical application requiring objective evaluation of gait outside of the lab environment.
Resumo:
OBJECTIVE: The aim of this pilot study was to describe problems in functioning and associated rehabilitation needs in persons with spinal cord injury after the 2010 earthquake in Haiti by applying a newly developed tool based on the International Classification of Functioning, Disability and Health (ICF). DESIGN: Pilot study. SUBJECTS: Eighteen persons with spinal cord injury (11 women, 7 men) participated in the needs assessment. Eleven patients had complete lesions (American Spinal Injury Association Impairment Scale; AIS A), one patient had tetraplegia. METHODS: Data collection included information from the International Spinal Cord Injury Core Data Set and a newly developed needs assessment tool based on ICF Core Sets. This tool assesses the level of functioning, the corresponding rehabilitation need, and required health professional. Data were summarized using descriptive statistics. RESULTS: In body functions and body structures, patients showed typical problems following spinal cord injury. Nearly all patients showed limitations and restrictions in their activities and participation related to mobility, self-care and aspects of social integration. Several environmental factors presented barriers to these limitations and restrictions. However, the availability of products and social support were identified as facilitators. Rehabilitation needs were identified in nearly all aspects of functioning. To address these needs, a multidisciplinary approach would be needed. CONCLUSION: This ICF-based needs assessment provided useful information for rehabilitation planning in the context of natural disaster. Future studies are required to test and, if necessary, adapt the assessment.
Resumo:
BACKGROUND: In patients with malignant pleural mesothelioma undergoing a multimodality therapy, treatment toxicity may outweigh the benefit of progression-free survival. The subjective experience across different treatment phases is an important clinical outcome. This study compares a standard with an individual quality of life (QoL) measure used in a multi-center phase II trial. PATIENTS AND METHODS: Sixty-one patients with stage I-III technically operable pleural mesothelioma were treated with preoperative chemotherapy, followed by pleuropneumonectomy and subsequent radiotherapy. QoL was assessed at baseline, at day 1 of cycle 3, and 1, 3 and 6 months post-surgery by using the Rotterdam Symptom Checklist (RSCL) and the Schedule for the Evaluation of Quality of Life-Direct Weighting (SEIQoL-DW), a measure that is based on five individually nominated and weighted QoL-domains. RESULTS: Completion rates were 98% (RSCL) and 92% (SEIQoL) at baseline and 98%/89% at cycle 3, respectively. Of the operated patients (N=45) RSCL and SEIQoL were available from 86%/72%, 93%/74%, and 94%/76% at months 1, 3, and 6 post-surgery. Average assessment time for the SEIQoL was 24min compared to 8min needed for the RSCL. Median changes from baseline indicate that both RSCL QoL overall score and SEIQoL index remained stable during chemotherapy with a clinically significant deterioration (change>or=8 points) 1 month after surgery (median change of -66 and -14 for RSCL and SEIQoL, respectively). RSCL QoL overall scores improved thereafter, but remained beneath baseline level until 6 months after surgery. SEIQoL scores improved to baseline-level at month 3 after surgery, but worsened again at month 6. RSCL QoL overall score and SEIQoL index were moderately correlated at baseline (r=.30; p<or=.05) and at 6-month follow-up (r=.42; p<or=.05) but not at the other time points. CONCLUSION: The SEIQoL assessment seems to be feasible within a phase II clinical trial, but may require more effort from staff. More distinctive QoL changes in accordance with clinical changes were measured with the RSCL. Our findings suggest that the two measures are not interchangeable: the RSCL is to favor when mainly information related to the course of disease- and treatment is of interest.
Resumo:
Background We assessed the impact of a smoking ban in hospitality venues in the Seychelles 9 months after legislation was implemented. Methods Survey officers observed compliance with the smoking ban in 38 most popular hospitality venues and administered a structured questionnaire to two customers, two workers and one manager in each venue. Results Virtually no customers or workers were seen smoking in the indoor premises. Patrons, workers and managers largely supported the ban. The personnel of the hospitality venues reported that most smokers had no difficulty refraining from smoking. However, a third of workers did not systematically request customers to stop smoking and half of them did not report adequate training. Workers reported improved health. No substantial change in the number of customers was noted. Conclusion A ban on public smoking was generally well implemented in hospitality venues but some less than optimal findings suggest the need for adequate training of workers and strengthened enforcement measures. The simple and inexpensive methodology used in this rapid survey may be a useful approach to evaluate the implementation and impact of clean air policy in low and middle-income countries.
Resumo:
Background Delirium is an independent predictor of increased length of stay, mortality, and treatment costs in critical care patients. Its incidence may be underestimated or overestimated if delirium is assessed by using subjective clinical impression alone rather than an objective instrument. Objectives To determine frequency of discrepancies between subjective and objective delirium monitoring. Methods An observational cohort study was performed in a surgical-cardiosurgical 31-bed intensive care unit of a university hospital. Patients' delirium status was rated daily by bedside nurses on the basis of subjective individual clinical impressions and by medical students on the basis of scores on the objective Confusion Assessment Method for the Intensive Care Unit. Results Of 160 patients suitable for analysis, 38.8% (n = 62) had delirium according to objective criteria at some time during their stay in the intensive care unit. A total of 436 paired observations were analyzed. Delirium was diagnosed in 26.1% of observations (n = 114) with the objective method. This percentage included 6.4% (n = 28) in whom delirium was not recognized via subjective criteria. According to subjective criteria, delirium was present in 29.4% of paired observations (n = 128), including 9.6% (n = 42) with no objective indications of delirium. A total of 8 patients with no evidence of delirium according to the objective criteria were prescribed haloperidol and lorazepam because the subjective method indicated they had delirium. Conclusions Use of objective criteria helped detect delirium in more patients and also identified patients mistakenly thought to have delirium who actually did not meet objective criteria for diagnosis of the condition.
Resumo:
PURPOSE: The purpose of this study was to study the pharmacokinetics of irinotecan injected intravenously, intra-arterially, or loaded onto a delivery platform. MATERIAL AND METHODS: Fifty-four New Zealand White rabbits with VX2 liver tumor, divided in 3 groups of 17 rabbits, each received irinotecan either by intravenous (IV) route, intra-arterial hepatic (IA) route, or loaded on drug-eluting beads (DEBIRI). Animals were killed at 1, 6, and 24 h. Irinotecan and SN-38 concentrations were measured at different time points in serum, tumor, and normal liver. RESULTS: Twelve milligrams of irinotecan were injected IV and IA, whereas 6-16.5 mg were injected loaded onto DEBIRI. Normalized serum irinotecan reached a peak of 333 ng/ml (range 198.8-502.5) for IV, 327.1 ng/ml (range 277.1-495.6) for IA, and 189.7 ng/ml (range 111.1-261.9) for DEBIRI (P < 0.001) delivery. The area-under-the-curve value from 10 to 60 min of serum irinotecan concentration was significantly lower for DEBIRI (P = 0.0009). Tumor irinotecan levels for IV, IA, and DEBIRI (in ng/200 mg of tissue followed by ranges in parentheses) were, respectively, 23.6 (0.3-24.9), 36.5 (7.7-1914.1), and 20.2 (2.9-319) at 1 h; 4.2 (1-27.9), 99.3 (46.6-159.5), and 42.1 (11.3-189) at 6 h; and 2.7 (2.5-6.9), 18.3 (1.5-369.1), and 174.4 (3.4-5147.3) at 24 h (P = 0.02). At 24 h, tumor necrosis was 25% (10-30), 60% (40-91.25), and 95% (76.25-95) for IV, IA, and DEBIRI, respectively (P = 0.03). CONCLUSION: Compared with IV or IA, DEBIRI induces lower early serum levels of irinotecan, a high and prolonged intratumoral level of irinotecan, and a greater rate of tumor necrosis at 24 h. Further evaluation of the clinical benefit of DEBIRI is warranted.
Resumo:
RésuméL'origine de l'obésité, qui atteint des proportions épidémiques, est complexe. Elle est liée au mode de vie et au comportement des individus par rapport à l'activité physique, expression des choix individuels et de l'interaction avec l'environnement. Les mesures du comportement au niveau de l'activité physique des individus face à leur environnement, la répartition des types d'activité physique, la durée, la fréquence, l'intensité, et la dépense énergétique sont d'une grande importance. Aujourd'hui, il y a un manque de méthodes permettant une évaluation précise et objective de l'activité physique et du comportement des individus. Afin de compléter les recherches relatives à l'activité physique, à l'obésité et à certaines maladies, le premier objectif du travail de thèse était de développer un modèle pour l'identification objective des types d'activité physique dans des conditions de vie réelles et l'estimation de la dépense énergétique basée sur une combinaison de 2 accéléromètres et 1 GPS. Le modèle prend en compte qu'une activité donnée peut être accomplie de différentes façons dans la vie réelle. Les activités quotidiennes ont pu être classées en 8 catégories, de sédentaires à actives, avec une précision de 1 min. La dépense énergétique a pu peut être prédite avec précision par le modèle. Après validation du modèle, le comportement des individus de l'activité physique a été évalué dans une seconde étude. Nous avons émis l'hypothèse que, dans un environnement caractérisé par les pentes, les personnes obèses sont tentées d'éviter les pentes raides et de diminuer la vitesse de marche au cours d'une activité physique spontanée, ainsi que pendant les exercices prescrits et structurés. Nous avons donc caractérisé, par moyen du modèle développé, le comportement des individus obèses dans un environnement vallonné urbain. La façon dont on aborde un environnement valloné dans les déplacements quotidiens devrait également être considérée lors de la prescription de marche supplémentaire afin d'augmenter l'activité physique.SummaryOrigin of obesity, that reached epidemic proportion, is complex and may be linked to different lifestyle and physical activity behaviour. Measurement of physical activity behaviour of individuals towards their environment, the distribution of physical activity in terms of physical activity type, volume, duration, frequency, intensity, and energy expenditure is of great importance. Nowadays, there is a lack of methods for accurate and objective assessment of physical activity and of individuals' physical activity behaviour. In order to complement the research relating physical activity to obesity and related diseases, the first aim of the thesis work was to develop a model for objective identification of physical activity types in real-life condition and energy expenditure based on a combination of 2 accelerometers and 1 GPS device. The model takes into account that a given activity can be achieved in many different ways in real life condition. Daily activities could be classified in 8 categories, as sedentary to active physical activity, within 1 min accuracy, and physical activity patterns determined. The energy expenditure could be predicted accurately with an accuracy below 10%. Furthermore, individuals' physical activity behaviour is expression of individual choices and their interaction with the neighbourhood environment. In a second study, we hypothesized that, in an environment characterized by inclines, obese individuals are tempted to avoid steep positive slopes and to decrease walking speed during spontaneous outdoor physical activity, as well as during prescribed structured bouts of exercise. Finally, we characterized, by mean of the developed model, the physical activity behaviour of obese individuals in a hilly urban environment. Quantifying how one tackles hilly environment or avoids slope in their everyday displacements should be also considered while prescribing extra walking in free-living conditions in order to increase physical activity.
Resumo:
In many European countries, image quality for digital x-ray systems used in screening mammography is currently specified using a threshold-detail detectability method. This is a two-part study that proposes an alternative method based on calculated detectability for a model observer: the first part of the work presents a characterization of the systems. Eleven digital mammography systems were included in the study; four computed radiography (CR) systems, and a group of seven digital radiography (DR) detectors, composed of three amorphous selenium-based detectors, three caesium iodide scintillator systems and a silicon wafer-based photon counting system. The technical parameters assessed included the system response curve, detector uniformity error, pre-sampling modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE). Approximate quantum noise limited exposure range was examined using a separation of noise sources based upon standard deviation. Noise separation showed that electronic noise was the dominant noise at low detector air kerma for three systems; the remaining systems showed quantum noise limited behaviour between 12.5 and 380 µGy. Greater variation in detector MTF was found for the DR group compared to the CR systems; MTF at 5 mm(-1) varied from 0.08 to 0.23 for the CR detectors against a range of 0.16-0.64 for the DR units. The needle CR detector had a higher MTF, lower NNPS and higher DQE at 5 mm(-1) than the powder CR phosphors. DQE at 5 mm(-1) ranged from 0.02 to 0.20 for the CR systems, while DQE at 5 mm(-1) for the DR group ranged from 0.04 to 0.41, indicating higher DQE for the DR detectors and needle CR system than for the powder CR phosphor systems. The technical evaluation section of the study showed that the digital mammography systems were well set up and exhibiting typical performance for the detector technology employed in the respective systems.
Resumo:
Age-related physiological changes and comorbidities affect older patients' tolerance to surgery. Pre-operative assessment in these patients requires, beside the usual physical evaluation, the systematic screening of common geriatric syndromes. Cognitive, gait and balance, nutritional, and functional impairments, all flag patients at higher risk for per- and postoperative complications. Preoperative assessment is an opportunity to detect these syndromes and propose preventative interventions (physical therapy, nutritional and cognitive support measures) likely to reduce the incidence of postoperative morbidity.