125 resultados para Artificial source
em Université de Lausanne, Switzerland
Resumo:
Traditionally, subcortical structures such as the cerebellum are supposed to exert a modulatory effect on epileptic seizures, rather than being the primary seizure generator. We report a 14-month old girl presenting, since birth, with seizures symptomatic of a right cerebellar dysplasia, manifested as paroxystic contralateral hemifacial spasm and ipsilateral facial weakness. Multimodal imaging was used to investigate both anatomical landmarks related to the cerebellar lesion and mechanisms underlying seizure generation. Electric source imaging (ESI) supported the hypothesis of a right cerebellar epileptogenic generator in concordance with nuclear imaging findings; subsequently validated by intra-operative intralesional recordings. Diffusion spectrum imaging-related tractography (DSI) showed severe cerebellar structural abnormalities confirmed by histological examination. We suggest that hemispheric cerebellar lesions in cases like this are likely to cause epilepsy via an effect on the facial nuclei through ipsilateral and contralateral aberrant connections.
Resumo:
Transplantation of insulin secreting cells is regarded as a possible treatment for type 1 diabetes. One major difficulty in this approach is, however, that the transplanted cells are exposed to the patient's inflammatory and autoimmune environment, which originally destroyed their own beta-cells. Therefore, even if a good source of insulin-secreting cells can be identified for transplantation therapy, these cells need to be protected against these destructive influences. The aim of this project was to evaluate, using a clonal mouse beta-cell line, whether genetic engineering of protective genes could be a viable option to allow these cells to survive when transplanted into autoimmune diabetic mice. We demonstrated that transfer of the Bcl-2 anti-apoptotic gene and of several genes specifically interfering with cytokines intracellular signalling pathways, greatly improved resistance of the cells to inflammatory stresses in vitro. We further showed that these modifications did not interfere with the capacity of these cells to correct hyperglycaemia for several months in syngeneic or allogeneic streptozocin-diabetic mice. However, these cells were not protected against autoimmune destruction when transplanted into type 1 diabetic NOD mice. This suggests that in addition to inflammatory attacks by cytokines, autoimmunity very efficiently kills the transplanted cells, indicating that multiple protective mechanisms are required for efficient transplantation of insulin-secreting cells to treat type 1 diabetes.
Resumo:
Since the inception of cardiopulmonary bypass (CPB), little progress has been made concerning the design of cardiotomy suction (CS). Because this is a major source of hemolysis, we decided to test a novel device (Smartsuction [SS]) specifically aimed at minimizing hemolysis during CPB in a clinical setting. Block randomization was carried out on a treated group (SS, n=28) and a control group (CTRL, n=26). Biochemical parameters were taken pre-, peri-, and post CPB and were compared between the two groups using the Student's t-test with statistical significance when P<0.05. No significant differences in patient demographics were observed between the two groups. Lactate dehydrogenase (LDH) and plasma free hemoglobin (PFH) pre-CPB were comparable for the CTRL and SS groups, respectively. LDH peri-CPB was 275+/-100 U/L versus 207+/-83 U/L for the CTRL and SS groups, respectively (P<0.05). PFH was 486+/-204 mg/L versus 351+/-176 mg/L for the CTRL and SS groups, respectively (P<0.05). LDH post CPB was 354+/-116 U/L versus 275+/-89 U/L for the CTRL and SS groups, respectively (P<0.05). PFH was 549+/-271 mg/L versus 460+/-254 mg/L for the CTRL and SS groups, respectively (P<0.05). Preoperative hematocrit (Hct) of 43+/-5% (CTRL) versus 37+/-5% (SS), and hemoglobin (Hb) of 141+/-16 g/L (CTRL) versus 122+/-17 g/L (SS) were significantly lower in the SS group. However, when normalized (N), the SS was capable of conserving Hct, Hb, and erythrocyte count perioperatively. Erythrocytes (N) were 59+/-5% (CTRL) versus 67+/-9% (SS); Hct (N) was 59+/-6% (CTRL) versus 68+/-9% (SS), and Hb (N) was 61+/-6% (CTRL) versus 70+/-10% (SS) (all P<0.05). This novel SS device evokes significantly lowered blood PFH and LDH values peri- and post CPB compared with the CTRL blood using a CS system. The SS may be a valuable alternative compared to traditional CS techniques.
Resumo:
In cases of highly inflammatory dermatophytosis in humans, it is important to identify the possible source of animal transmission in order to prevent recurrence, family outbreaks or rapidly progressing epidemics. A survey of dermatophytes in pets during a 14-month period in Switzerland revealed, in addition to Microsporum canis, two different species of the Trichophyton mentagrophytes complex, Arthroderma benhamiae and Arthroderma vanbreuseghemii, all causing inflammatory dermatophytoses. Arthroderma benhamiae was only and frequently isolated from guinea pigs. Arthroderma vanbreuseghemii was isolated mainly from European short hair cats, but also from dogs and in one case from a pure-bred cat. Ninety-three percent of the cats carrying A. vanbreuseghemii were hunters and all had skin lesions. In contrast, cats with skin lesions that were strictly indoors were found to be almost exclusively infected by M. canis. Therefore, it can be suspected that infection with A. vanbreuseghemii occurred during hunting and that the natural source of this dermatophyte is either soil or an animal other than the cat, most probably a rodent.
Resumo:
Electroencephalography is mandatory to determine the epilepsy syndrome. However, for the precise localization of the irritative zone in patients with focal epilepsy, costly and sometimes cumbersome imaging techniques are used. Recent small studies using electric source imaging suggest that electroencephalography itself could be used to localize the focus. However, a large prospective validation study is missing. This study presents a cohort of 152 operated patients where electric source imaging was applied as part of the pre-surgical work-up allowing a comparison with the results from other methods. Patients (n = 152) with >1 year postoperative follow-up were studied prospectively. The sensitivity and specificity of each imaging method was defined by comparing the localization of the source maximum with the resected zone and surgical outcome. Electric source imaging had a sensitivity of 84% and a specificity of 88% if the electroencephalogram was recorded with a large number of electrodes (128-256 channels) and the individual magnetic resonance image was used as head model. These values compared favourably with those of structural magnetic resonance imaging (76% sensitivity, 53% specificity), positron emission tomography (69% sensitivity, 44% specificity) and ictal/interictal single-photon emission-computed tomography (58% sensitivity, 47% specificity). The sensitivity and specificity of electric source imaging decreased to 57% and 59%, respectively, with low number of electrodes (<32 channels) and a template head model. This study demonstrated the validity and clinical utility of electric source imaging in a large prospective study. Given the low cost and high flexibility of electroencephalographic systems even with high channel counts, we conclude that electric source imaging is a highly valuable tool in pre-surgical epilepsy evaluation.
Resumo:
(Résumé de l'ouvrage) A travers l'étude d'un corpus littéraire, constitué par le quatrième Evangile et les trois épîtres de Jean, il est possible de retracer l'histoire d'une tradition théologique originale et du groupe social qui en fut le porteur, la communauté johannique.
Resumo:
There are far-reaching conceptual similarities between bi-static surface georadar and post-stack, "zero-offset" seismic reflection data, which is expressed in largely identical processing flows. One important difference is, however, that standard deconvolution algorithms routinely used to enhance the vertical resolution of seismic data are notoriously problematic or even detrimental to the overall signal quality when applied to surface georadar data. We have explored various options for alleviating this problem and have tested them on a geologically well-constrained surface georadar dataset. Standard stochastic and direct deterministic deconvolution approaches proved to be largely unsatisfactory. While least-squares-type deterministic deconvolution showed some promise, the inherent uncertainties involved in estimating the source wavelet introduced some artificial "ringiness". In contrast, we found spectral balancing approaches to be effective, practical and robust means for enhancing the vertical resolution of surface georadar data, particularly, but not exclusively, in the uppermost part of the georadar section, which is notoriously plagued by the interference of the direct air- and groundwaves. For the data considered in this study, it can be argued that band-limited spectral blueing may provide somewhat better results than standard band-limited spectral whitening, particularly in the uppermost part of the section affected by the interference of the air- and groundwaves. Interestingly, this finding is consistent with the fact that the amplitude spectrum resulting from least-squares-type deterministic deconvolution is characterized by a systematic enhancement of higher frequencies at the expense of lower frequencies and hence is blue rather than white. It is also consistent with increasing evidence that spectral "blueness" is a seemingly universal, albeit enigmatic, property of the distribution of reflection coefficients in the Earth. Our results therefore indicate that spectral balancing techniques in general and spectral blueing in particular represent simple, yet effective means of enhancing the vertical resolution of surface georadar data and, in many cases, could turn out to be a preferable alternative to standard deconvolution approaches.
Resumo:
We would like to comment this study recently published in JFS. It is a short technical note proposing an artificial aging technique for the dating of ballpoint pen inks. This is a very difficult and controversial topic, and we are worried about the nature of this paper. The authors propose several ideas to differentiate fast aging and slow aging inks, but their experimental data is not validly represented and/or discussed. The data is insufficient to draw any conclusions about any potential of the method for ink dating purposes. This lack of information on the subject must be filled before proposing such methods for practical caseworks. These are preliminary and unconvincing results from development research performed in a laboratory on controlled samples without due warnings about potential shortcomings. They cannot be used or even compared to results obtained in real situations on uncontrolled specimens of limited size, unknown composition and undefined storage conditions. This can leave an undeserved feeling that these methods are ready for implementation when the task of ensuring their scientific validity is still far away.
Resumo:
We have recently reported that the PD-1 and CTLA4 signaling pathways are active in both effector and regulatory T cells, causing profound immune dysfunctions in the tumor microenvironment. In line with this notion, the dual blockade of PD-1- and CTLA4-conveyed signals may exert robust therapeutic effects. Here, we discuss the mechanisms possibly underlying such a synergic interaction.
Resumo:
Ventricular assist devices (VADs) are used in treatment for terminal heart failure or as a bridge to transplantation. We created biVAD using the artificial muscles (AMs) that supports both ventricles at the same time. We developed the test bench (TB) as the in vitro evaluating system to enable the measurement of performance. The biVAD exerts different pressure between left and right ventricle like the heart physiologically does. The heart model based on child's heart was constructed in silicone. This model was fitted with the biVAD. Two pipettes containing water with an ultrasonic sensor placed on top of each and attached to ventricles reproduced the preload and the after load of each ventricle by the real-time measurement of the fluid height variation proportionally to the exerted pressure. The LabVIEW software extrapolated the displaced volume and the pressure generated by each side of our biVAD. The development of a standardized protocol permitted the validation of the TB for in vitro evaluation, measurement of the performances of the AM biVAD herein, and reproducibility of data.
Resumo:
This paper presents the Juste-Neige system for predicting the snow height on the ski runs of a resort using a multi-agent simulation software. Its aim is to facilitate snow cover management in order to i) reduce the production cost of artificial snow and to improve the profit margin for the companies managing the ski resorts; and ii) to reduce the water and energy consumption, and thus to reduce the environmental impact, by producing only the snow needed for a good skiing experience. The software provides maps with the predicted snow heights for up to 13 days. On these maps, the areas most exposed to snow erosion are highlighted. The software proceeds in three steps: i) interpolation of snow height measurements with a neural network; ii) local meteorological forecasts for every ski resort; iii) simulation of the impact caused by skiers using a multi-agent system. The software has been evaluated in the Swiss ski resort of Verbier and provides useful predictions.
Resumo:
Objectives: The AMS 800TM is the current artificial urinary sphincter (AUS) for incontinence due to intrinsic sphincter deficiency. Despite good clinical results, technical failures inherent to the hydraulic mechanism or urethral ischemic injury contribute to revisions up to 60%. We are developing an electronic AUS, called ARTUS to overcome the rigors of AMS. The objective of this study was to evaluate the technical efficacy and tissue tolerance of the ARTUS system in an animal model.Methods: The ARTUS is composed by three parts: the contractile unit, a series of rings and an integrated microprocessor. The contractile unit is made of Nitinol fibers. The rings are placed around the urethra to control the flow of urine by squeezing the urethra. They work in a sequential alternative mode and are controlled by a microprocessor. In the first phase a three-rings device was used while in the second phase a two-rings ARTUS was used. The device was implanted in 14 sheep divided in two groups of six and eight animals for study purpose. The first group aimed at bladder leak point pressure (BLPP) measurement and validation of the animal model; the second group aimed at verifying mid-term tissue tolerance by explants at twelve weeks. General animal tolerance was also evaluated.Results: The ARTUS system implantation was uneventful. When the system was activated, the BLPP was measured at 1.038±0.044 bar (mean±SD). Urethral tissue analysis did not show significant morphological changes. No infection and no sign of discomfort were noted in animals at 12 weeks.Conclusions: The ARTUS proved to be effective in continence achievement in this study. Histological results support our idea that a sequential alternative mode can avoid urethral atrophy and ischemia. Further technical developments are needed to verify long-term outcome and permit human use.
Resumo:
Background: The posterior circulation Acute Stroke Prognosis Early CT Score (pc-ASPECTS) and the combined Pons-midbrain score quantify the extent of early ischemic changes in the posterior circulation. We compared the prognostic accuracy of both scores if applied to CT angiography (CTA) source images (CTA-SI) of patients in the Basilar Artery International Cooperation Study (BASICS).Methods: BASICS was a prospective, observational, multi-centre, registry of consecutive patients who presented with acute symptomatic basilar artery occlusion (BAO). Functional outcome was assessed at 1 month. We applied pc-ASPECTS and the combined Pons-midbrain score to CTA-SI by 3-reader-consensus. Readers were blinded to clinical data. We performed multivariable logistic regression analysis, adjusting for thrombolysis, baseline NIHSS score and age, and used the output to derive ROC curves to compare the ability of both scores to discriminate patients with favourable (modified Rankin Scale [mRS] scores 0-3) from patients with unfavourable (mRS scores 4-6) functional outcome.Results: We reviewed CTAs of 158 patients (64% men, mean age 65 _ 15 years, median NIHSS score 25 [0-38], median GCS score 7 [3-15], median onset-to-CTA time 234 minutes [11-7380]). At 1 month, 40 (25%) patients had a favourable outcome, 49 (31%) had an unfavourable outcome (mRS score 4-5) and 69 (44%) were deceased. Both techniques of assessing CTA-SI hypoattenuation in the posterior circulation showed equally good discriminative value in predicting final outcome (C-statistics; area under ROC curve 0.74 versus 0.75, respectively; p_0.37). Pc-ASPECTS dichotomized at _6 versus _6 was an independent predictor of favourable functional outcome (RR _ 2.2; CI95 1.1-4.7; p _ 0.034).Conclusion: Compared to the combined Pons-midbrain score, the pc-ASPECTS score has similar prognostic accuracy to identify patients with a favourable functional outcome in BASICS. Dichotomized pc-ASPECTS (_6 versus _6) is an independent predictor of favourable functional outcome in this population. Author Disclosures: V. Puetz: None. A. Khomenko: None. M.D. Hill: None. I. Dzialowski: None. P. Michel: None. C. Weimar: None. C.A.C. Wijman: None. H. Mattle: None. K. Muir: None. T. Pfefferkorn: None. D. Tanne: None. S. Engelter: None. K. Szabo: None. A. Algra: None. A.M. Demchuk: None. W.J. Schonewille: None.