85 resultados para Artificial respiration.
em Université de Lausanne, Switzerland
Resumo:
The health status of previously premature neonates after closure of a patent ductus arteriosus (PDA) was analyzed in childhood and adolescence. Physician questionnaires were used to study 180 hospital survivors among 210 consecutive premature neonates who underwent PDA closure between 1985 and 2005. Complete follow-up data were obtained for 129 patients (72%). During a median follow-up period of 7 years (range, 2-22 years), three late deaths (2.3%) had occurred. Only 45% of the patients were considered healthy. Morbidity included developmental delay (41.1%), pulmonary illness (12.4%), neurologic impairment (14.7%), hearing impairment (3.9%), gastrointestinal disease (3.1%), and thoracic deformity (1.2%). None of the adverse variables during the neonatal period (intraventricular hemorrhage, bradycardia apnea syndrome, bronchopulmonary dysplasia, pulmonary bleeding, hyaline membrane disease, artificial respiration time [continuous positive airway pressure + intubation], or necrotizing enterocolitis) statistically predicted respective system morbidity at the follow-up evaluation. Hyaline membrane disease (odds ratio, 2.5; p = 0.026) and longer hospitalization time (odds ratio, 1.2 days per 10 hospitalization days; p = 0.032) in the newborn period were significant predictors of an unhealthy outcome at the last follow-up evaluation. Survival until childhood after closure of a hemodynamically significant PDA in premature neonates is satisfactory. However, physical and neurodevelopmental co-morbidity persist for half of the patients, perhaps as a sequela of prematurity unrelated to ductus closure.
Resumo:
In Part I of this review, we have covered basic concepts regarding cardiorespiratory interactions. Here, we put this theoretical framework to practical use. We describe mechanisms underlying Kussmaul's sign and pulsus paradoxus. We review the literature on the use of respiratory variations of blood pressure to evaluate volume status. We show the possibilities of attaining the latter aim by investigating with ultrasonography how the geometry of great veins fluctuates with respiration. We provide a Guytonian analysis of the effects of PEEP on cardiac output. We terminate with some remarks on the potential of positive pressure breathing to induce acute cor pulmonale, and on the cardiovascular mechanisms that at times may underly the failure to wean a patient from the ventilator.
Resumo:
BACKGROUND: To date, there is no quality assurance program that correlates patient outcome to perfusion service provided during cardiopulmonary bypass (CPB). A score was devised, incorporating objective parameters that would reflect the likelihood to influence patient outcome. The purpose was to create a new method for evaluating the quality of care the perfusionist provides during CPB procedures and to deduce whether it predicts patient morbidity and mortality. METHODS: We analysed 295 consecutive elective patients. We chose 10 parameters: fluid balance, blood transfused, Hct, ACT, PaO2, PaCO2, pH, BE, potassium and CPB time. Distribution analysis was performed using the Shapiro-Wilcoxon test. This made up the PerfSCORE and we tried to find a correlation to mortality rate, patient stay in the ICU and length of mechanical ventilation. Univariate analysis (UA) using linear regression was established for each parameter. Statistical significance was established when p < 0.05. Multivariate analysis (MA) was performed with the same parameters. RESULTS: The mean age was 63.8 +/- 12.6 years with 70% males. There were 180 CABG, 88 valves, and 27 combined CABG/valve procedures. The PerfSCORE of 6.6 +/- 2.4 (0-20), mortality of 2.7% (8/295), CPB time 100 +/- 41 min (19-313), ICU stay 52 +/- 62 hrs (7-564) and mechanical ventilation of 10.5 +/- 14.8 hrs (0-564) was calculated. CPB time, fluid balance, PaO2, PerfSCORE and blood transfused were significantly correlated to mortality (UA, p < 0.05). Also, CPB time, blood transfused and PaO2 were parameters predicting mortality (MA, p < 0.01). Only pH was significantly correlated for predicting ICU stay (UA). Ultrafiltration (UF) and CPB time were significantly correlated (UA, p < 0.01) while UF (p < 0.05) was the only parameter predicting mechanical ventilation duration (MA). CONCLUSIONS: CPB time, blood transfused and PaO2 are independent risk factors of mortality. Fluid balance, blood transfusion, PaO2, PerfSCORE and CPB time are independent parameters for predicting morbidity. PerfSCORE is a quality of perfusion measure that objectively quantifies perfusion performance.
Resumo:
We would like to comment this study recently published in JFS. It is a short technical note proposing an artificial aging technique for the dating of ballpoint pen inks. This is a very difficult and controversial topic, and we are worried about the nature of this paper. The authors propose several ideas to differentiate fast aging and slow aging inks, but their experimental data is not validly represented and/or discussed. The data is insufficient to draw any conclusions about any potential of the method for ink dating purposes. This lack of information on the subject must be filled before proposing such methods for practical caseworks. These are preliminary and unconvincing results from development research performed in a laboratory on controlled samples without due warnings about potential shortcomings. They cannot be used or even compared to results obtained in real situations on uncontrolled specimens of limited size, unknown composition and undefined storage conditions. This can leave an undeserved feeling that these methods are ready for implementation when the task of ensuring their scientific validity is still far away.
Resumo:
To investigate whether respiratory acidosis modulates ventilator-induced lung injury (VILI), we perfused (constant flow) 21 isolated sets of normal rabbit lungs, ventilated them for 20 min (pressure controlled ventilation [PCV] = 15 cm H(2)O) (Baseline) with an inspired CO(2) fraction adjusted for the partial pressure of CO(2) in the perfusate (PCO(2) approximately equal to 40 mm Hg), and then randomized them into three groups. Group A (control: n = 7) was ventilated with PCV = 15 cm H(2)O for three consecutive 20-min periods (T1, T2, T3). In Group B (high PCV/normocapnia; n = 7), PCV was given at 20 (T1), 25 (T2), and 30 (T3) cm H(2)O. The targeted PCO(2) was 40 mm Hg in Groups A and B. Group C (high PCV/hypercapnia; n = 7) was ventilated in the same way as Group B, but the targeted PCO(2) was approximately equal to 70 to 100 mm Hg. The changes (from Baseline to T3) in weight gain (Delta WG: g) and in the ultrafiltration coefficient (Delta K(f) = gr/min/ cm H(2)O/100g) and the protein and hemoglobin concentrations in bronchoalveolar lavage fluid (BALF) were used to assess injury. Group B experienced a significantly greater Delta WG (14.85 +/- 5.49 [mean +/- SEM] g) and Delta K(f) (1.40 +/- 0.49 g/min/cm H(2)O/100 g) than did either Group A (Delta WG = 0.70 +/- 0.43; Delta K(f) = 0.01 +/- 0.03) or Group C (Delta WG = 5.27 +/- 2.03 g; Delta K(f) = 0.25 +/- 0.12 g/min/cm H(2)O/ 100 g). BALF protein and hemoglobin concentrations (g/L) were higher in Group B (11.98 +/- 3.78 g/L and 1.82 +/- 0.40 g/L, respectively) than in Group A (2.92 +/- 0.75 g/L and 0.38 +/- 0.15 g/L) or Group C (5.71 +/- 1.88 g/L and 1.19 +/- 0.32 g/L). We conclude that respiratory acidosis decreases the severity of VILI in this model.
Resumo:
Ventricular assist devices (VADs) are used in treatment for terminal heart failure or as a bridge to transplantation. We created biVAD using the artificial muscles (AMs) that supports both ventricles at the same time. We developed the test bench (TB) as the in vitro evaluating system to enable the measurement of performance. The biVAD exerts different pressure between left and right ventricle like the heart physiologically does. The heart model based on child's heart was constructed in silicone. This model was fitted with the biVAD. Two pipettes containing water with an ultrasonic sensor placed on top of each and attached to ventricles reproduced the preload and the after load of each ventricle by the real-time measurement of the fluid height variation proportionally to the exerted pressure. The LabVIEW software extrapolated the displaced volume and the pressure generated by each side of our biVAD. The development of a standardized protocol permitted the validation of the TB for in vitro evaluation, measurement of the performances of the AM biVAD herein, and reproducibility of data.
Resumo:
This paper presents the Juste-Neige system for predicting the snow height on the ski runs of a resort using a multi-agent simulation software. Its aim is to facilitate snow cover management in order to i) reduce the production cost of artificial snow and to improve the profit margin for the companies managing the ski resorts; and ii) to reduce the water and energy consumption, and thus to reduce the environmental impact, by producing only the snow needed for a good skiing experience. The software provides maps with the predicted snow heights for up to 13 days. On these maps, the areas most exposed to snow erosion are highlighted. The software proceeds in three steps: i) interpolation of snow height measurements with a neural network; ii) local meteorological forecasts for every ski resort; iii) simulation of the impact caused by skiers using a multi-agent system. The software has been evaluated in the Swiss ski resort of Verbier and provides useful predictions.
Resumo:
Pulse oximetry has been proposed as a noninvasive continuous method for transcutaneous monitoring of arterial oxygen saturation of hemoglobin (tcSO2) in the newborn infant. The reliability of this technique in detecting hyperoxemia is controversial, because small changes in saturation greater than 90% are associated with relatively large changes in arterial oxygen tension (PaO2). The purpose of this study was to assess the reliability of pulse oximetry using an alarm limit of 95% tcSO2 in detecting hyperoxemia (defined as PaO2 greater than 90 mm Hg) and to examine the effect of varying the alarm limit on reliability. Two types of pulse oximeter were studied alternately in 50 newborn infants who were mechanically ventilated with indwelling arterial lines. Three arterial blood samples were drawn from every infant during routine increase of inspired oxygen before intratracheal suction, and PaO2 was compared with tcSO2. The Nellcor N-100 pulse oximeter identified all 26 hyperoxemic instances correctly (sensitivity 100%) and alarmed falsely in 25 of 49 nonhyperoxemic instances (specificity 49%). The Ohmeda Biox 3700 pulse oximeter detected 13 of 35 hyperoxemic instances (sensitivity 37%) and alarmed falsely in 7 of 40 nonhyperoxemic instances (specificity 83%). The optimal alarm limit, defined as a sensitivity of 95% or more associated with maximal specificity, was determined for Nellcor N-100 at 96% tcSO2 (specificity 38%) and for Ohmeda Biox 3700 at 89% tcSO2 (specificity 52%). It was concluded that pulse oximeters can be highly sensitive in detecting hyperoxemia provided that type-specific alarm limits are set and a low specificity is accepted.
Resumo:
Objectives: The AMS 800TM is the current artificial urinary sphincter (AUS) for incontinence due to intrinsic sphincter deficiency. Despite good clinical results, technical failures inherent to the hydraulic mechanism or urethral ischemic injury contribute to revisions up to 60%. We are developing an electronic AUS, called ARTUS to overcome the rigors of AMS. The objective of this study was to evaluate the technical efficacy and tissue tolerance of the ARTUS system in an animal model.Methods: The ARTUS is composed by three parts: the contractile unit, a series of rings and an integrated microprocessor. The contractile unit is made of Nitinol fibers. The rings are placed around the urethra to control the flow of urine by squeezing the urethra. They work in a sequential alternative mode and are controlled by a microprocessor. In the first phase a three-rings device was used while in the second phase a two-rings ARTUS was used. The device was implanted in 14 sheep divided in two groups of six and eight animals for study purpose. The first group aimed at bladder leak point pressure (BLPP) measurement and validation of the animal model; the second group aimed at verifying mid-term tissue tolerance by explants at twelve weeks. General animal tolerance was also evaluated.Results: The ARTUS system implantation was uneventful. When the system was activated, the BLPP was measured at 1.038±0.044 bar (mean±SD). Urethral tissue analysis did not show significant morphological changes. No infection and no sign of discomfort were noted in animals at 12 weeks.Conclusions: The ARTUS proved to be effective in continence achievement in this study. Histological results support our idea that a sequential alternative mode can avoid urethral atrophy and ischemia. Further technical developments are needed to verify long-term outcome and permit human use.
Resumo:
OBJECTIVE : To determine the prevalence of patient-ventilator asynchrony in patients receiving non-invasive ventilation (NIV) for acute respiratory failure. DESIGN : Prospective multicenter observation study. SETTING : Intensive care units in three university hospitals. METHODS: Patients consecutively admitted to ICU were included. NIV, performed with an ICU ventilator, was set by the clinician. Airway pressure, flow, and surface diaphragmatic electromyography were recorded continuously for 30 min. Asynchrony events and the asynchrony index (AI) were determined from visual inspection of the recordings and clinical observation. RESULTS: A total of 60 patients were included, 55% of whom were hypercapnic. Auto-triggering was present in 8 (13%) patients, double triggering in 9 (15%), ineffective breaths in 8 (13%), premature cycling 7 (12%) and late cycling in 14 (23%). An AI > 10%, indicating severe asynchrony, was present in 26 patients (43%), whose median (25-75 IQR) AI was 26 (15-54%). A significant correlation was found between the magnitude of leaks and the number of ineffective breaths and severity of delayed cycling. Multivariate analysis indicated that the level of pressure support and the magnitude of leaks were weakly, albeit significantly, associated with an AI > 10%. Patient comfort scale was higher in pts with an AI < 10%. CONCLUSION: Patient-ventilator asynchrony is common in patients receiving NIV for acute respiratory failure. Our results suggest that leaks play a major role in generating patient-ventilator asynchrony and discomfort, and point the way to further research to determine if ventilator functions designed to cope with leaks can reduce asynchrony in the clinical setting.
Resumo:
Acute severe asthma is defined by the occurrence of an acute exacerbation resistant to the initial medical treatment, complicated by life-threatening respiratory distress due to severe lung hyperinflation. The conventional therapeutic approach is based on oxygen therapy and on the combined treatment of inhaled beta2-agonists at repeated doses and systemic corticosteroids. Inhaled or systemic magnesium sulfate is also recommended. The unresponsiveness to the initial bronchodilating therapy and the development of respiratory distress requiring intubation significantly increases mortality, due to the complications induced by mechanical ventilation. In these situations, a ventilatory strategy, including controlled hypoventilation with permissive hypercapnia, aiming at preventing lung hyperinflation, is indicated. Non-invasive ventilation may be successful in certain patients and represents an effective alternative to intubation. In ventilated patients, helium-oxygen mixtures can be considered as adjunctive therapies. After having reviewed the basic pathophysiological principles, this article will focus on the current medical treatment and of the modalities of mechanical ventilation in acute severe asthma.
Resumo:
WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: The AMS 800 urinary control system is the gold standard for the treatment of urinary incontinence due to sphincter insufficiency. Despite excellent functional outcome and latest technological improvements, the revision rate remains significant. To overcome the shortcomings of the current device, we developed a modern electromechanical artificial urinary sphincter. The results demonstrated that this new sphincter is effective and well tolerated up to 3 months. This preliminary study represents a first step in the clinical application of novel technologies and an alternative compression mechanism to the urethra. OBJECTIVES: To evaluate the effectiveness in continence achievement of a new electromechanical artificial urinary sphincter (emAUS) in an animal model. To assess urethral response and animal general response to short-term and mid-term activation of the emAUS. MATERIALS AND METHODS: The principle of the emAUS is electromechanical induction of alternating compression of successive segments of the urethra by a series of cuffs activated by artificial muscles. Between February 2009 and May 2010 the emAUS was implanted in 17 sheep divided into three groups. The first phase aimed to measure bladder leak point pressure during the activation of the device. The second and third phases aimed to assess tissue response to the presence of the device after 2-9 weeks and after 3 months respectively. Histopathological and immunohistochemistry evaluation of the urethra was performed. RESULTS: Bladder leak point pressure was measured at levels between 1091 ± 30.6 cmH2 O and 1244.1 ± 99 cmH2 O (mean ± standard deviation) depending on the number of cuffs used. At gross examination, the explanted urethra showed no sign of infection, atrophy or stricture. On microscopic examination no significant difference in structure was found between urethral structure surrounded by a cuff and control urethra. In the peripheral tissues, the implanted material elicited a chronic foreign body reaction. Apart from one case, specimens did not show significant presence of lymphocytes, polymorphonuclear leucocytes, necrosis or cell degeneration. Immunohistochemistry confirmed the absence of macrophages in the samples. CONCLUSIONS: This animal study shows that the emAUS can provide continence. This new electronic controlled sequential alternating compression mechanism can avoid damage to urethral vascularity, at least up to 3 months after implantation. After this positive proof of concept, long-term studies are needed before clinical application could be considered.