84 resultados para Articular range of motion
em Université de Lausanne, Switzerland
Resumo:
Universal standard goniometer is an essential tool to measure articulations' range of motion (ROM). In this time of technological advances and increasing use of smartphones, new measurement's tools appear as specific smartphone applications. This article compares the iOS application "Knee Goniometer" with universal standard goniometer to assess knee ROM. To our knowledge, this is the first study that uses a goniometer application in a clinical context. The purpose of this study is to determine if this application could be used in clinical practice.
Resumo:
PURPOSE: The impacts of humeral offset and stem design after reverse shoulder arthroplasty (RSA) have not been well-studied, particularly with regard to newer stems which have a lower humeral inclination. The purpose of this study was to analyze the effect of different humeral stem designs on range of motion and humeral position following RSA. METHODS: Using a three-dimensional computer model of RSA, a traditional inlay Grammont stem was compared to a short curved onlay stem with different inclinations (155°, 145°, 135°) and offset (lateralised vs medialised). Humeral offset, the acromiohumeral distance (AHD), and range of motion were evaluated for each configuration. RESULTS: Altering stem design led to a nearly 7-mm change in humeral offset and 4 mm in the AHD. Different inclinations of the onlay stems had little influence on humeral offset and larger influence on decreasing the AHD. There was a 10° decrease in abduction and a 5° increase in adduction between an inlay Grammont design and an onlay design with the same inclination. Compared to the 155° model, the 135° model improved adduction by 28°, extension by 24° and external rotation of the elbow at the side by 15°, but led to a decrease in abduction of 9°. When the tray was placed medially, on the 145° model, a 9° loss of abduction was observed. CONCLUSIONS: With varus inclination prostheses (135° and 145°), elevation remains unchanged, abduction slightly decreases, but a dramatic improvement in adduction, extension and external rotation with the elbow at the side are observed.
Resumo:
PURPOSE: To determine whether motion preservation following oblique cervical corpectomy (OCC) for cervical spondylotic myelopathy (CSM) persists with serial follow-up. METHODS: We included 28 patients with preoperative and at least two serial follow-up neutral and dynamic cervical spine radiographs who underwent OCC for CSM. Patients with an ossified posterior longitudinal ligament (OPLL) were excluded. Changes in sagittal curvature, segmental and whole spine range of motion (ROM) were measured. Nathan's system graded anterior osteophyte formation. Neurological function was measured by Nurick's grade and modified Japanese Orthopedic Association (JOA) scores. RESULTS: The majority (23 patients) had a single or 2-level corpectomy. The average duration of follow-up was 45 months. The Nurick's grade and the JOA scores showed statistically significant improvements after surgery (p < 0.001). 17% of patients with preoperative lordotic spines had a loss of lordosis at last follow-up, but with no clinical worsening. 77% of the whole spine ROM and 62% of segmental ROM was preserved at last follow-up. The whole spine and segmental ROM decreased by 11.2° and 10.9°, respectively (p ≤ 0.001). Patients with a greater range of segmental movement preoperatively had a statistically greater range of movement at follow-up. The analysis of serial radiographs indicated that the range of movement of the whole spine and the range of movement at the segmental spine levels significantly reduced during the follow-up period. Nathan's grade showed increase in osteophytosis in more than two-thirds of the patients (p ≤ 0.01). The whole spine range of movement at follow-up significantly correlated with Nathan's grade. CONCLUSIONS: Although the OCC preserves segmental and whole spine ROM, serial measurements show a progressive decrease in ROM albeit without clinical worsening. The reduction in this ROM is probably related to degenerative ossification of spinal ligaments.
Resumo:
PURPOSE: To document the neurological outcome, spinal alignment and segmental range of movement after oblique cervical corpectomy (OCC) for cervical compressive myelopathy. METHODS: This retrospective study included 109 patients--93 with cervical spondylotic myelopathy and 16 with ossified posterior longitudinal ligament in whom spinal curvature and range of segmental movements were assessed on neutral and dynamic cervical radiographs. Neurological function was measured by Nurick's grade and modified Japanese Orthopedic Association (JOA) scores. Eighty-eight patients (81%) underwent either a single- or two-level corpectomy; the remaining (19%) undergoing three- or four-level corpectomies. The average duration of follow-up was 30.52 months. RESULTS: The Nurick's grade and the JOA scores showed statistically significant improvements after surgery (p < 0.001). The mean postoperative segmental angle in the neutral position straightened by 4.7 ± 6.5°. The residual segmental range of movement for a single-level corpectomy was 16.7° (59.7% of the preoperative value), for two-level corpectomy it was 20.0° (67.2%) and for three-level corpectomies it was 22.9° (74.3%). 63% of patients with lordotic spines continued to have lordosis postoperatively while only one became kyphotic without clinical worsening. Four patients with preoperative kyphotic spines showed no change in spine curvature. None developed spinal instability. CONCLUSIONS: The OCC preserves segmental motion in the short-term, however, the tendency towards straightening of the spine, albeit without clinical worsening, warrants serial follow-up imaging to determine whether this motion preservation is long lasting.
Resumo:
A new ambulatory technique for qualitative and quantitative movement analysis of the humerus is presented. 3D gyroscopes attached on the humerus were used to recognize the movement of the arm and to classify it as flexion, abduction and internal/external rotations. The method was first validated in a laboratory setting and then tested on 31 healthy volunteer subjects while carrying the ambulatory system during 8 h of their daily life. For each recording, the periods of sitting, standing and walking during daily activity were detected using an inertial sensor attached on the chest. During each period of daily activity the type of arm movement (flexion, abduction, internal/external rotation) its velocity and frequency (number of movement/hour) were estimated. The results showed that during the whole daily activity and for each activity (i.e. walking, sitting and walking) the frequency of internal/external rotation was significantly higher while the frequency of abduction was the lowest (P < 0.009). In spite of higher number of flexion, abduction and internal/external rotation in the dominant arm, we have not observed in our population a significant difference with the non-dominant arm, implying that in healthy subjects the arm dominance does not lie considerably on the number of movements. As expected, the frequency of the movement increased from sitting to standing and from standing to walking, while we provide a quantitative value of this change during daily activity. This study provides preliminary evidence that this system is a useful tool for objectively assessing upper-limb activity during daily activity. The results obtained with the healthy population could be used as control data to evaluate arm movement of patients with shoulder diseases during daily activity.
Resumo:
BACKGROUND: An objective measurement of surgical procedures outcomes is inherent to professional practices quality control; this especially applies in orthopaedics to joint replacement outcomes. A self-administered questionnaire offers an attractive alternative to surgeon's judgement but is infrequently used in France for these purposes. The British questionnaire, the 12-item Oxford Hip Score (OHS) was selected for this study because of its ease of use. HYPOTHESIS: The objective of this study was to validate the French translation of the self-assessment 12-item Oxford Hip Score and compare its results with those of the reference functional scores: the Harris Hip Score (HHS) and the Postel-Merle d'Aubigné (PMA) score. MATERIALS AND METHODS: Based on a clinical series of 242 patients who were candidates for total hip arthroplasty, the French translation of this questionnaire was validated. Its coherence was also validated by comparing the preoperative data with the data obtained from the two other reference clinical scores. RESULTS: The translation was validated using the forward-backward translation procedure from French to English, with correction of all differences or mistranslations after systematized comparison with the original questionnaire in English. The mean overall OHS score was 43.8 points (range, 22-60 points) with similarly good distribution of the overall value of the three scores compared. The correlation was excellent between the OHS and the HHS, but an identical correlation between the OHS and the PMA was only obtained for the association of the pain and function parameters, after excluding the mobility criterion, relatively over-represented in the PMA score. DISCUSSION AND CONCLUSION: Subjective questionnaires that contribute a personal appreciation of the results of arthroplasty by the patient can easily be applied on a large scale. This study made a translated and validated version of an internationally recognized, reliable self-assessment score available to French orthopaedic surgeons. The results obtained encourage us to use this questionnaire as a complement to the classical evaluation scores and methods.
Resumo:
A new method of measuring joint angle using a combination of accelerometers and gyroscopes is presented. The method proposes a minimal sensor configuration with one sensor module mounted on each segment. The model is based on estimating the acceleration of the joint center of rotation by placing a pair of virtual sensors on the adjacent segments at the center of rotation. In the proposed technique, joint angles are found without the need for integration, so absolute angles can be obtained which are free from any source of drift. The model considers anatomical aspects and is personalized for each subject prior to each measurement. The method was validated by measuring knee flexion-extension angles of eight subjects, walking at three different speeds, and comparing the results with a reference motion measurement system. The results are very close to those of the reference system presenting very small errors (rms = 1.3, mean = 0.2, SD = 1.1 deg) and excellent correlation coefficients (0.997). The algorithm is able to provide joint angles in real-time, and ready for use in gait analysis. Technically, the system is portable, easily mountable, and can be used for long term monitoring without hindrance to natural activities.
Resumo:
HYPOTHESIS: Supraspinatus deficiency associated with total shoulder arthroplasty (TSA) provokes eccentric loading and may induce loosening of the glenoid component. A downward inclination of the glenoid component has been proposed to balance supraspinatus deficiency. METHODS: This hypothesis was assessed by a numeric musculoskeletal model of the glenohumeral joint during active abduction. Three cases were compared: TSA with normal muscular function, TSA with supraspinatus deficiency, and TSA with supraspinatus deficiency and downward inclination of the glenoid. RESULTS: Supraspinatus deficiency increased humeral migration and eccentric loading. A downward inclination of the glenoid partly balanced the loss of stability, but this potential advantage was counterbalanced by an important stress increase within the glenoid cement. The additional subchondral bone reaming required to incline the glenoid component indeed reduced the bone support, increasing cement deformation and stress. CONCLUSION: Glenoid inclination should not be obtained at the expense of subchondral bone support.
Resumo:
The free extended lateral arm flap (ELAF) has gained increasing popularity thank to its slimness and versatility, longer neurovascular pedicle, and greater flap size when compared with the original flap design. The aim of this study was to assess the donor-site morbidity associated with this extended procedure. A retrospective study of 25 consecutive patients analyzing postoperative complications using a visual analogue scale questionnaire revealed high patients satisfaction and negligible donor-site morbidity of the ELAF. Scar visibility was the commonest negative outcome. Impaired mobility of the elbow had the highest correlation with patient dissatisfaction. Sensory deficits or paresthetic disorders did not affect patient satisfaction. The extension of the lateral arm flap and positioning over the lateral humeral epicondyle is a safe and well-accepted procedure with minimal donor-site morbidity. To optimize outcomes, a maximal flap width of 6 or 7 cm and intensive postoperative mobilization therapy is advisable.
Resumo:
This study reviewed the subjective, clinical and radiological outcome of 71 patients (84 feet) treated by scarf osteotomy for hallux valgus deformity at our institution from 1995 to 1998 with an average follow-up time of 22 months (range, 17 to 48 months). At the time of follow-up, 39% of the patients were very satisfied, 50% were satisfied and 11% were not satisfied. The mean AOFAS score raised significantly from 43 points (14-68) preoperatively to 82 points (39 to 100) at follow-up (p < 0.001). The radiological angles including M1-M2, M1-P1, M1-M5 and DMAA improved significantly (p < 0.001). Among the 16 complications recorded, seven (8%) were minor and nine (11%) required an additional procedure. The scarf osteotomy of the first metatarsal coupled with a lateral soft-tissue release and, in three-quarters of our cases, with a basal closing wedge varisation osteotomy of the first phalanx, resulted in overall high satisfaction rate as well as significant clinical and radiological improvements in our series. Nevertheless, the range of motion of the first MP joint remained low: 30 degrees to 74 degrees in 52 patients (62%) and <30 degrees in four patients (5%). Furthermore, the mobility of the first ray as well as the consequences of the procedure in the sagittal plane need to be assessed more accurately, and this may be achieved by incorporating measurement of the plantar pressures in the forefoot area into the global rating system.
Resumo:
BACKGROUND: Clinical results of total ankle arthroplasty with early designs were disappointing. Recently-developed ankle prostheses have good mid-term results; however, limited information is available regarding effects of total ankle arthroplasty on ankle laxity. METHODS: Eight cadaveric lower extremities were tested with a custom device which enabled measurement of multi-axial forces, moments, and displacement during applied axial, shear, and rotational loading. Tests consisted of anterior-posterior and medial-lateral translation and internal-external rotation of the talus relative to the tibia during axial loads on the tibia simulating body weight (700 N) and an unloaded condition (5 N). Tests were performed in neutral, dorsiflexion, and plantarflexion. Laxity was determined for the intact ankle, and following insertion of an unconstrained total ankle implant, comparing load-displacement curve. FINDINGS: Laxity after total ankle arthroplasty did not approximate the normal ankle in most conditions tested. Displacement was significantly greater for total ankle arthroplasty in both posterior and lateral translation, and internal rotation, with 5 N axial loading, and anterior-posterior, medial-lateral translation, and internal-external rotation for 700 N axial loading. For the 700 N axial load condition, in the neutral ankle position, total anterior-posterior translation averaged 0.4 mm (SD 0.2 mm), but 6.0 mm (SD 1.5 mm) after total ankle arthroplasty (P<0.01). This study demonstrated more laxity in the replaced ankle than normal ankle for both unloaded and 700 N axially loaded conditions. INTERPRETATION: These data indicate the increased responsibility of the ligaments for ankle laxity after total ankle arthroplasty and suggest the importance of meticulous ligament reconstruction with total ankle arthroplasty operations.
Resumo:
In the 1920s, Ronald Fisher developed the theory behind the p value and Jerzy Neyman and Egon Pearson developed the theory of hypothesis testing. These distinct theories have provided researchers important quantitative tools to confirm or refute their hypotheses. The p value is the probability to obtain an effect equal to or more extreme than the one observed presuming the null hypothesis of no effect is true; it gives researchers a measure of the strength of evidence against the null hypothesis. As commonly used, investigators will select a threshold p value below which they will reject the null hypothesis. The theory of hypothesis testing allows researchers to reject a null hypothesis in favor of an alternative hypothesis of some effect. As commonly used, investigators choose Type I error (rejecting the null hypothesis when it is true) and Type II error (accepting the null hypothesis when it is false) levels and determine some critical region. If the test statistic falls into that critical region, the null hypothesis is rejected in favor of the alternative hypothesis. Despite similarities between the two, the p value and the theory of hypothesis testing are different theories that often are misunderstood and confused, leading researchers to improper conclusions. Perhaps the most common misconception is to consider the p value as the probability that the null hypothesis is true rather than the probability of obtaining the difference observed, or one that is more extreme, considering the null is true. Another concern is the risk that an important proportion of statistically significant results are falsely significant. Researchers should have a minimum understanding of these two theories so that they are better able to plan, conduct, interpret, and report scientific experiments.
Resumo:
Children with unresolved brachial plexus palsy frequently develop a disabling internal rotation contracture of the shoulder. Several surgical options, including soft tissue procedures such as muscle releases and/or transfers, and bone operations such as humeral osteotomy are available to correct this deformity. This study describes the effect of subscapularis muscle release performed in isolation. Thirteen patients (5 boys, 8 girls) were reviewed at an average of 3.5 years after their surgery (range, 2-7 years). Their mean age at operation was 4.7 years (range, 1-8 years). Three children had C5-C6 palsies, 8 had C5-C7 palsies, and 2 had C5-C8 palsies. Postoperatively, patients presented significant gains in shoulder active lateral rotation (+49 degrees, from 5 to 54 degrees), active abduction (+30 degrees, from 63 to 93 degrees), active flexion (+46 degrees, from 98 to 144 degrees), and active extension (+23 degrees, from 7 to 30 degrees). Gains were also observed in passive range of motion, but of a lesser degree. Subscapularis muscle release is a procedure we found to have few significant complications and was highly effective in increasing active range of motion and restoring shoulder function.