210 resultados para Arsenic -- Toxicology

em Université de Lausanne, Switzerland


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A remarkable feature of the carcinogenicity of inorganic arsenic is that while human exposures to high concentrations of inorganic arsenic in drinking water are associated with increases in skin, lung, and bladder cancer, inorganic arsenic has not typically caused tumors in standard laboratory animal test protocols. Inorganic arsenic administered for periods of up to 2 yr to various strains of laboratory mice, including the Swiss CD-1, Swiss CR:NIH(S), C57Bl/6p53(+/-), and C57Bl/6p53(+/+), has not resulted in significant increases in tumor incidence. However, Ng et al. (1999) have reported a 40% tumor incidence in C57Bl/6J mice exposed to arsenic in their drinking water throughout their lifetime, with no tumors reported in controls. In order to investigate the potential role of tissue dosimetry in differential susceptibility to arsenic carcinogenicity, a physiologically based pharmacokinetic (PBPK) model for inorganic arsenic in the rat, hamster, monkey, and human (Mann et al., 1996a, 1996b) was extended to describe the kinetics in the mouse. The PBPK model was parameterized in the mouse using published data from acute exposures of B6C3F1 mice to arsenate, arsenite, monomethylarsonic acid (MMA), and dimethylarsinic acid (DMA) and validated using data from acute exposures of C57Black mice. Predictions of the acute model were then compared with data from chronic exposures. There was no evidence of changes in the apparent volume of distribution or in the tissue-plasma concentration ratios between acute and chronic exposure that might support the possibility of inducible arsenite efflux. The PBPK model was also used to project tissue dosimetry in the C57Bl/6J study, in comparison with tissue levels in studies having shorter duration but higher arsenic treatment concentrations. The model evaluation indicates that pharmacokinetic factors do not provide an explanation for the difference in outcomes across the various mouse bioassays. Other possible explanations may relate to strain-specific differences, or to the different durations of dosing in each of the mouse studies, given the evidence that inorganic arsenic is likely to be active in the later stages of the carcinogenic process. [Authors]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intoxications are a frequent problem in the ER. In the vast majorityof cases, supportive treatment is sufficient. Severe intoxications withunknown agents are considered an indication for a urinary drug screen,and are recommended by several toxicology centers. However, theirusefulness for patient management remains uncertain.Study objectives: Evaluation of the impact of a urinary drug screen(Biosite Triage TOX Drug Screen) testing 11 substances(acetaminophen, amphetamines, methamphetamines, barbiturates,benzodiazepines, cocaïne, methadone, opioids, phencyclidine,cannabis, tricyclic antidepressants) on initial adult patient managementin the emergency department of a university hospital with ~35.000annual admissions.Methods: Observational retrospective analysis of all tests performedbetween 09/2009 and 09/2010. A test utility was defined as useful if itresulted in the administration of a specific antidote (Flumazenil/Naloxone), the use of a quantitative confirmatory toxicologic test, or achange in patient's disposition.Results: 57 tests were performed. Patient age was 32 ± 11 (SD) years;58% were men; 30% were also intoxicated with alcohol. Two patientsdied (3.5%): the first one of a diphenhydramin overdose, the other of ahypertensive intracerebral hemorrhage believed to be caused cocaineabuse but a negative urine test. Test indications were: 54% firstpsychotic episode; 25% acute respiratory failure; 18% coma; 12%seizure; 11% opioids toxidrome; 7% sympathicomimetic toxidrome; 5%hypotension; 4% ventricular arrhythmia (VT, VF, torsades de pointes)or long QT. 75% of tests were positives for >=1 substance (mean 1.7 ±0.9). 47% of results were unexpected by history. 18% of resultsinfluenced patient management: 7% had a negative test that confirmedthe diagnosis of endogenous psychosis in a first psychotic episode, andallowed transfer to psychiatry; 5% received flumazenil/naloxone;2% had an acetaminophen blood level after a positive screen; finally,4% had an unexpected methadone abuse that required prolongationof hospital stay.Conclusions: A rapid urinary toxicologic screen was seldom used inour emergency department, and its impact on patient managementwas marginal: only one in 6 tests influenced treatment decisions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the development of an analytical technique for arsenic analyses that is based on genetically-modified bioreporter bacteria bearing a gene encoding for the production of a green fluorescent protein (gfp). Upon exposure to arsenic (in the aqueous form of arsenite), the bioreporter production of the fluorescent reporter molecule is monitored spectroscopically. We compared the response measured as a function of time and concentration by steady-state fluorimetry (SSF) to that measured by epi-fluorescent microscopy (EFM). SSF is a bulk technique; as such it inherently yields less information, whereas EFM monitors the response of many individual cells simultaneously and data can be processed in terms of population averages or subpopulations. For the bioreporter strain used here, as well as for the literature we cite, the two techniques exhibit similar performance characteristics. The results presented here show that the EFM technique can compete with SSF and shows substantially more promise for future improvement; it is a matter of research interest to develop optimized methods of EFM image analysis and statistical data treatment. EFM is a conduit for understanding the dynamics of individual cell response vs. population response, which is not only a matter of research interest, but is also promising in the practical terms of developing micro-scale analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A luminescent bacterial biosensor was used to quantify bioavailable arsenic in artificial groundwater. Its light production above the background emission was proportional to the arsenite concentration in the toxicologically relevant range of 0 to 0.5 mu M. Effects of the inorganic solutes phosphate, Fe(II) and silicate on the biosensor signal were studied. Phosphate at a concentration of 0.25 g L-1 phosphate slightly stimulated the light emission, but much less than toxicologically relevant concentrations of the much stronger inducer arsenite. No effect of phosphate was oberved in the presence of arsenite. Freshly prepared sodium silicate solution at a concentration of 10 g L-1 Si reduced the arsenite-induced light production by roughly 37%, which can be explained by transient polymerization leading to sequestration of some arsenic. After three days of incubation, silicate did not have this effect anymore, probably because depolymerization occurred. In the presence of 0.4 g L-1 Fe(II), the arsenite-induced light emission was reduced by up to 90%, probably due to iron oxidation followed by arsenite adsorption on the less soluble Fe(III) possibly along with some oxidation to the stronger adsorbing As(V). Addition of 100 mu M EDTA was capable of releasing all arsenic from the precipitate and to transform it into the biologically measurable, dissolved state. The biosensor also proved valuable for monitoring the effectiveness of an arsenic removal procedure based on water filtration through a mixture of sand and iron granules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A test kit based on living, lyophilized bacterial bioreporters emitting bioluminescence as a response to arsenite and arsenate was applied during a field campaign in six villages across Bangladesh. Bioreporter field measurements of arsenic in groundwater from tube wells were in satisfying agreement with the results of spectroscopic analyses of the same samples conducted in the lab. The practicability of the bioreporter test in terms of logistics and material requirements, suitability for high sample throughput, and waste disposal was much better than that of two commercial chemical test kits that were included as references. The campaigns furthermore demonstrated large local heterogeneity of arsenic in groundwater, underscoring the use of well switching as an effective remedy to avoid high arsenic exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arsenic contamination of natural waters is a worldwide concern, as the drinking water supplies for large populations can have high concentrations of arsenic. Traditional techniques to detect arsenic in natural water samples can be costly and time-consuming; therefore, robust and inexpensive methods to detect arsenic in water are highly desirable. Additionally, methods for detecting arsenic in the field have been greatly sought after. This article focuses on the use of bacteria-based assays as an emerging method that is both robust and inexpensive for the detection of arsenic in groundwater both in the field and in the laboratory. The arsenic detection elements in bacteria-based bioassays are biosensor-reporter strains; genetically modified strains of, e.g., Escherichia coli, Bacillus subtilis, Staphylococcus aureus, and Rhodopseudomonas palustris. In response to the presence of arsenic, such bacteria produce a reporter protein, the amount or activity of which is measured in the bioassay. Some of these bacterial biosensor-reporters have been successfully utilized for comparative in-field analyses through the use of simple solution-based assays, but future methods may concentrate on miniaturization using fiberoptics or microfluidics platforms. Additionally, there are other potential emerging bioassays for the detection of arsenic in natural waters including nematodes and clams.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a compact portable biosensor to measure arsenic As(III) concentrations in water using Escherichia coli bioreporter cells. Escherichia coli expresses green fluorescent protein in a linearly dependent manner as a function of the arsenic concentration (between 0 and 100 μg/L). The device accommodates a small polydimethylsiloxane microfluidic chip that holds the agarose-encapsulated bacteria, and a complete optical illumination/collection/detection system for automated quantitative fluorescence measurements. The device is capable of sampling water autonomously, controlling the whole measurement, storing and transmitting data over GSM networks. We demonstrate highly reproducible measurements of arsenic in drinking water at 10 and 50 μg/L within 100 and 80 min, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Escherichia coli-based bioreporters for arsenic detection are typically based on the natural feedback loop that controls ars operon transcription. Feedback loops are known to show a wide range linear response to the detriment of the overall amplification of the incoming signal. While being a favourable feature in controlling arsenic detoxification for the cell, a feedback loop is not necessarily the most optimal for obtaining highest sensitivity and response in a designed cellular reporter for arsenic detection. Here we systematically explore the effects of uncoupling the topology of arsenic sensing circuitry on the developed reporter signal as a function of arsenite concentration input. A model was developed to describe relative ArsR and GFP levels in feedback and uncoupled circuitry, which was used to explore new ArsR-based synthetic circuits. The expression of arsR was then placed under the control of a series of constitutive promoters, which differed in promoter strength, and which could be further modulated by TetR repression. Expression of the reporter gene was maintained under the ArsR-controlled Pars promoter. ArsR expression in the systems was measured by using ArsR-mCherry fusion proteins. We find that stronger constitutive ArsR production decreases arsenite-dependent EGFP output from Pars and vice versa. This leads to a tunable series of arsenite-dependent EGFP outputs in a variety of systematically characterized circuitries. The higher expression levels and sensitivities of the response curves in the uncoupled circuits may be useful for improving field-test assays using arsenic bioreporters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La recherche de substances ayant pu jouer un rôle direct ou indirect dans la cause de la mort ou ayant pu modifier le comportement d'un individu constitue la mission première de la toxicologie forensique. L'augmentation de la consommation de substances illégales et de médicaments dans les sociétés modernes a fait connaître à la toxicologie forensique un essor très important ces dernières décennies. D'autre part, les développements technologiques analytiques ont permis d'obtenir des outils très sensibles et spécifiques pour la recherche et le dosage d'une multitude de substances dans une grande variété d'échantillons biologiques, parfois présentes à des concentrations très faibles, conséquence d'une dose équivalente à la prise d'une seule unité galénique. Forensic toxicology has to bring evidence of substances that could have been involved directly or indirectly in the cause of death or that could influence the behaviour of somebody. The increase of the consumption of illegal and legal drugs in modern societies during last decades gave a boost to forensic toxicology. Moreover, improvement with analytical technology gave tools with high degrees of sensitivity and specificity for the screening and quantification of a large amount of substances in various biological specimens, even with very low concentration resulting of a single dose of medication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The adsorption of As(V) onto alpha -Al2O3 was investigated at 25, 50 and 70 degreesC using batch adsorption experiments. Results indicate that As is strongly adsorbed at low pH and gets progressively released to the fluid with increasing pH above 7. At any pH, increasing temperature favors aqueous species of As over surface species. Surface complexation constants were determined at the experimental temperatures by fitting the adsorption data. Adsorption reactions were then converted to semi-isocolumbic reactions, i.e, reactions with balanced like-charged aqueous species. Intrinsic adsorption constants of semi-isocolumbic reactions change linearly when plotted against inverse temperature, suggesting that the heat capacity of these reactions remains constant over the temperature range considered. This permitted thermodynamic parameters of intrinsic surface complexation constants to be determined. Changes in surface complexation constants result in a change in the surface speciation with increasing temperature. This change is similar to the one observed for aqueous species, i.e. increasing temperature favors less negatively charged species below a pH of 9 and more negatively charged species above a pH of 10. Comparison with the stability of As surface complexes with Fe suggests that surface complexes with Al are more stable. (C) 2001 Elsevier Science Ltd. All rights reserved.