35 resultados para Aqueous Mixtures

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The genetic characterization of unbalanced mixed stains remains an important area where improvementis imperative. Most cases of aggression, homicide and sexual assault produce biological traces withrelatively large amount of the victim's DNA and small amount of the aggressor's DNA. If this ratio issmaller than 1:10 it is currently not possible to obtain a conventional autosomal DNA profile of the minorcontributor, with potential loss of crucial DNA evidence. Y-STR analysis represents a solution for somecases but has several limitations. We propose here a method based on a new compound genetic markerformed by a Deletion/Insertion Polymorphism (DIP) linked to a Short Tandem Repeat polymorphism(STR), that we name DIP-STR. By means of allele-specific amplifications of DIP-STR haplotypes, we canproduce a high resolution autosomal DNA profile of a donor that contributes less than 0.1% to a DNAmixture. Based on these features DIP-STR markers may outperform conventional Y-STR markers inmixed stain analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Imaging mass spectrometry (IMS) is an emergent and innovative approach for measuring the composition, abundance and regioselectivity of molecules within an investigated area of fixed dimension. Although providing unprecedented molecular information compared with conventional MS techniques, enhancement of protein signature by IMS is still necessary and challenging. This paper demonstrates the combination of conventional organic washes with an optimized aqueous-based buffer for tissue section preparation before matrix-assisted laser desorption/ionization (MALDI) IMS of proteins. Based on a 500 mM ammonium formate in water-acetonitrile (9:1; v/v, 0.1% trifluororacetic acid, 0.1% Triton) solution, this buffer wash has shown to significantly enhance protein signature by profiling and IMS (~fourfold) when used after organic washes (70% EtOH followed by 90% EtOH), improving the quality and number of ion images obtained from mouse kidney and a 14-day mouse fetus whole-body tissue sections, while maintaining a similar reproducibility with conventional tissue rinsing. Even if some protein losses were observed, the data mining has demonstrated that it was primarily low abundant signals and that the number of new peaks found is greater with the described procedure. The proposed buffer has thus demonstrated to be of high efficiency for tissue section preparation providing novel and complementary information for direct on-tissue MALDI analysis compared with solely conventional organic rinsing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Samples containing highly unbalanced DNA mixtures from two individuals commonly occur both in forensic mixed stains and in peripheral blood DNA microchimerism induced by pregnancy or following organ transplant. Because of PCR amplification bias, the genetic identification of a DNA that contributes trace amounts to a mixed sample represents a tremendous challenge. This means that standard genetic markers, namely microsatellites, also referred as short tandem repeats (STR), and single-nucleotide polymorphism (SNP) have limited power in addressing common questions of forensic and medical genetics. To address this issue, we developed a molecular marker, named DIP-STR that relies on pairing deletion-insertion polymorphisms (DIP) with STR. This novel analytical approach allows for the unambiguous genotyping of a minor component in the presence of a major component, where DIP-STR genotypes of the minor were successfully procured at ratios up to 1:1,000. The compound nature of this marker generates a high level of polymorphism that is suitable for identity testing. Here, we demonstrate the power of the DIP-STR approach on an initial set of nine markers surveyed in a Swiss population. Finally, we discuss the limitations and potential applications of our new system including preliminary tests on clinical samples and estimates of their performance on simulated DNA mixtures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new and original reagent based on the use of highly fluorescent cadmium telluride (CdTe) quantum dots (QDs) in aqueous solution is proposed to detect weak fingermarks in blood on non-porous surfaces. To assess the efficiency of this approach, comparisons were performed with one of the most efficient blood reagents on non-porous surfaces, Acid Yellow 7 (AY7). To this end, four non-porous surfaces were studied, i.e. glass, transparent polypropylene, black polyethylene, and aluminium foil. To evaluate the sensitivity of both reagents, sets of depleted fingermarks were prepared, using the same finger, initially soaked with blood, which was then successively applied on the same surface without recharging it with blood or latent secretions. The successive marks were then cut in halves and the halves treated separately with each reagent. The results showed that QDs were equally efficient to AY7 on glass, polyethylene and polypropylene surfaces, and were superior to AY7 on aluminium. The use of QDs in new, sensitive and highly efficient latent and blood mark detection techniques appears highly promising. Health and safety issues related to the use of cadmium are also discussed. It is suggested that applying QDs in aqueous solution (and not as a dry dusting powder) considerably lowers the toxicity risks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Elevated IOP is commonly associated with iris and ciliary body melanoma. Traditional management requires the majority of eyes to undergo enucleation. The authors describe the first series of Baerveldt aqueous shunts in eyes with uveal melanoma, treated by total anterior segment irradiation.Methods: 25 consecutive patients with unilateral iris melanoma were prospectively recruited after obtaining informed consent. All patients underwent anterior segment proton beam irradiation, corneal limbal autografts and Baerveldt tube implantation at Jules Gonin Eye Hospital, Lausanne. Postoperative examinations were performed on day 1, weeks 1,3,6,9 and months 3,6,12 and annually thereafter. Success was defined as: IOP </=18mmHg (definition A); IOP </= 21mmHg and 20% reduction in IOP (definition B). All complications were recorded.Results: Mean age was 53; mean follow up, 10.3 months; mean interval to treatment following irradiation, 2.4 years; mean pre-op IOP was 29.9 mmHg; mean post-op IOP 14.1 mmHg; mean pre-op medications 3.0; post-op medications 1.3. Success rates were, definition A: 95%; definition B: 90%. Only11% had minor complications and there were no sight-threatening complications. Aggressive ocular hypertension was observed in the several eyes prior to shunt implantation. Two eyes were enucleated for non-glaucoma related sequelae.Conclusions: Baerveldt aqueous shunts are safe and efficacious following total anterior segment irradiation for uveal melanoma. The novel interdisciplinary approach improved ocular retention rates, offering a promising alternative to current management algorithms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The genetic characterization of unbalanced mixed stains remains an important area where improvement is imperative. In fact, with current methods for DNA analysis (Polymerase Chain Reaction with the SGM Plus™ multiplex kit), it is generally not possible to obtain a conventional autosomal DNA profile of the minor contributor if the ratio between the two contributors in a mixture is smaller than 1:10. This is a consequence of the fact that the major contributor's profile 'masks' that of the minor contributor. Besides known remedies to this problem, such as Y-STR analysis, a new compound genetic marker that consists of a Deletion/Insertion Polymorphism (DIP), linked to a Short Tandem Repeat (STR) polymorphism, has recently been developed and proposed elsewhere in literature [1]. The present paper reports on the derivation of an approach for the probabilistic evaluation of DIP-STR profiling results obtained from unbalanced DNA mixtures. The procedure is based on object-oriented Bayesian networks (OOBNs) and uses the likelihood ratio as an expression of the probative value. OOBNs are retained in this paper because they allow one to provide a clear description of the genotypic configuration observed for the mixed stain as well as for the various potential contributors (e.g., victim and suspect). These models also allow one to depict the assumed relevance relationships and perform the necessary probabilistic computations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a compact portable biosensor to measure arsenic As(III) concentrations in water using Escherichia coli bioreporter cells. Escherichia coli expresses green fluorescent protein in a linearly dependent manner as a function of the arsenic concentration (between 0 and 100 μg/L). The device accommodates a small polydimethylsiloxane microfluidic chip that holds the agarose-encapsulated bacteria, and a complete optical illumination/collection/detection system for automated quantitative fluorescence measurements. The device is capable of sampling water autonomously, controlling the whole measurement, storing and transmitting data over GSM networks. We demonstrate highly reproducible measurements of arsenic in drinking water at 10 and 50 μg/L within 100 and 80 min, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lake Geneva is one of the largest European lakes with a surface area of 580 km2. Its catchment area covers 7400 km2, of which approximately 20% is arable land. Monitoring campaigns have been carried out in 2004 and 2005 to determine the contamination of the lake by pesticides. The results highlight the widespread presence of herbicides in water, the measured concentrations for most substances remaining constant in 2004 and 2005. However, for some individual herbicides the concentrations increased drastically (e.g., the herbicide foramsulfuron). We assessed the environmental risk of the herbicides detected in the lake using water quality criteria recently determined for the Swiss environmental protection agency. Furthermore, we assessed the risk of herbicide mixtures, grouped based upon their mode of action. Generally, the risk estimated for all single substances is low, except for some sulfonylurea compounds. For these substances, the measured concentrations are higher than the predicted no-effect concentration. Impact on the flora of the lake can therefore not be excluded. When mixtures of pesticides with similar mode of action are taken into account, the risk remains lower than the mixture water quality criteria for all groups, but can reach as high as one third of this quality criteria. A further step would therefore be to assess the risk of the total pesticide mixture, including similar and dissimilar modes of action

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE The choice of containers for storage of aqueous samples between their collection, transport and water hydrogen (2H) and oxygen (18O) stable isotope analysis is a topic of concern for a wide range of fields in environmental, geological, biomedical, food, and forensic sciences. The transport and separation of water molecules during water vapor or liquid uptake by sorption or solution and the diffusive transport of water molecules through organic polymer material by permeation or pervaporation may entail an isotopic fractionation. An experiment was conducted to evaluate the extent of such fractionation. METHODS Sixteen bottle-like containers of eleven different organic polymers, including low and high density polyethylene (LDPE and HDPE), polypropylene (PP), polycarbonate (PC), polyethylene terephthalate (PET), and perfluoroalkoxy-Teflon (PFA), of different wall thickness and size were completely filled with the same mineral water and stored for 659?days under the same conditions of temperature and humidity. Particular care was exercised to keep the bottles tightly closed and prevent loss of water vapor through the seals. RESULTS Changes of up to +5 parts per thousand for d2H values and +2.0 parts per thousand for d18O values were measured for water after more than 1?year of storage within a plastic container, with the magnitude of change depending mainly on the type of organic polymer, wall thickness, and container size. The most important variations were measured for the PET and PC bottles. Waters stored in glass bottles with Polyseal (TM) cone-lined PP screw caps and thick-walled HDPE or PFA containers with linerless screw caps having an integrally molded inner sealing ring preserved their original d2H and d18O values. The carbon, hydrogen, and oxygen stable isotope compositions of the organic polymeric materials were also determined. CONCLUSIONS The results of this study clearly show that for precise and accurate measurements of the water stable isotope composition in aqueous solutions, rigorous sampling and storage procedures are needed both for laboratory standards and for unknown samples. Copyright (c) 2012 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Aqueous shunt implantation into the anterior chamber is associated with corneal decompensation in up to a third of eyes. Intracameral tube position may affect corneal endothelial cell loss. The authors set out to examine the efficacy and safety of Baerveldt shunt implantation into the ciliary sulcus combined with surgical peripheral iridectomy (SPI). Methods: One hundred eyes prospectively underwent Baerveldt shunt implantation into the cilliary sulcus combined with SPI, leaving a short intracameral tube length (1-2mm). Pre and post operative measures recorded included patient demographics, visual acuity, IOP, number of glaucoma medications (GMs) and all complications. Pre-existing corneal decompensation was recorded. Success was defined as IOP≤21mmHg and 20% reduction in IOP from baseline with or without GMs. Results: Mean age was 65.4 years (±20.4years). Mean follow-up was 10.8 months. Preoperatively IOP was 25.7mmHg (± 9.9mmHg), GMs were 2.9 (±1.2) and VA was 0.4 (±0.3). At one year postoperatively there was a significant drop in IOP (mean= 13.3mmHg (± 5.0mmHg); p<0.001) and number of GMs (mean= 1.3 (±1.4); p<0.001); and no significant change in VA (mean= 0.4 (±0.3); p=0.93). The success rate at one year was 83%. Complications were minor and non sight threatening (10%), there were no cases of postoperative corneal decompensation, tube blockage or iris/corneal-tube contact. Conclusions: The results demonstrate that placement of Baerveldt shunts into the ciliary sulcus with SPI is a safe and efficacious method of IOP reduction in comparison with standard shunt positioning in the anterior chamber. The intracameral tube position combined with SPI avoided tube-iris contact and corneal decompensation. Sulcus placement of aqueous shunts should be considered in pseudophakic eyes.