42 resultados para Applications and trend
em Université de Lausanne, Switzerland
Resumo:
Biological materials are increasingly used in abdominal surgery for ventral, pelvic and perineal reconstructions, especially in contaminated fields. Future applications are multi-fold and include prevention and one-step closure of infected areas. This includes prevention of abdominal, parastomal and pelvic hernia, but could also include prevention of separation of multiple anastomoses, suture- or staple-lines. Further indications could be a containment of infected and/or inflammatory areas and protection of vital implants such as vascular grafts. Reinforcement patches of high-risk anastomoses or unresectable perforation sites are possibilities at least. Current applications are based mostly on case series and better data is urgently needed. Clinical benefits need to be assessed in prospective studies to provide reliable proof of efficacy with a sufficient follow-up. Only superior results compared with standard treatment will justify the higher costs of these materials. To date, the use of biological materials is not standard and applications should be limited to case-by-case decision.
Resumo:
Skin diseases may have severe aesthetic and psychological repercussions leading sometimes to discriminations and social isolation. Dermatologists have contributed to the development of many cosmetic procedures: peelings, botulinum toxin or hyaluronic acid injections, lasers, blepharoplasty, facelift, etc. Many of these treatments have interesting clinical applications and may help numerous patients with skin diseases to return to a normal social life.
Resumo:
Over the past decade, CMRA has emerged as a unique clinical imaging tool with applications in selected populations. Patients with suspected coronary artery anomalies and patients with Kawasaki disease and coronary aneurysms are among those for whom CMRA has demonstrated clinical usefulness. For assessment of patients with atherosclerotic CAD, CMRA is useful for detection of patency of bypass grafts. At centers with appropriate expertise and resources, CMRA also appears to be of value for exclusion of severe proximal multivessel CAD in selected patients. Data from multicenter trials will continue to define the clinical role of CMRA, particularly as it relates to assessment of CAD. Future developments and enhancements of CMRA promise better lumen and coronary artery wall imaging. This may become the new target in noninvasive evaluation of CAD.
Resumo:
The research reported in this series of article aimed at (1) automating the search of questioned ink specimens in ink reference collections and (2) at evaluating the strength of ink evidence in a transparent and balanced manner. These aims require that ink samples are analysed in an accurate and reproducible way and that they are compared in an objective and automated way. This latter requirement is due to the large number of comparisons that are necessary in both scenarios. A research programme was designed to (a) develop a standard methodology for analysing ink samples in a reproducible way, (b) comparing automatically and objectively ink samples and (c) evaluate the proposed methodology in forensic contexts. This report focuses on the last of the three stages of the research programme. The calibration and acquisition process and the mathematical comparison algorithms were described in previous papers [C. Neumann, P. Margot, New perspectives in the use of ink evidence in forensic science-Part I: Development of a quality assurance process for forensic ink analysis by HPTLC, Forensic Sci. Int. 185 (2009) 29-37; C. Neumann, P. Margot, New perspectives in the use of ink evidence in forensic science- Part II: Development and testing of mathematical algorithms for the automatic comparison of ink samples analysed by HPTLC, Forensic Sci. Int. 185 (2009) 38-50]. In this paper, the benefits and challenges of the proposed concepts are tested in two forensic contexts: (1) ink identification and (2) ink evidential value assessment. The results show that different algorithms are better suited for different tasks. This research shows that it is possible to build digital ink libraries using the most commonly used ink analytical technique, i.e. high-performance thin layer chromatography, despite its reputation of lacking reproducibility. More importantly, it is possible to assign evidential value to ink evidence in a transparent way using a probabilistic model. It is therefore possible to move away from the traditional subjective approach, which is entirely based on experts' opinion, and which is usually not very informative. While there is room for the improvement, this report demonstrates the significant gains obtained over the traditional subjective approach for the search of ink specimens in ink databases, and the interpretation of their evidential value.
Resumo:
The research reported in this series of article aimed at (1) automating the search of questioned ink specimens in ink reference collections and (2) at evaluating the strength of ink evidence in a transparent and balanced manner. These aims require that ink samples are analysed in an accurate and reproducible way and that they are compared in an objective and automated way. This latter requirement is due to the large number of comparisons that are necessary in both scenarios. A research programme was designed to (a) develop a standard methodology for analysing ink samples in a reproducible way, (b) comparing automatically and objectively ink samples and (c) evaluate the proposed methodology in forensic contexts. This report focuses on the last of the three stages of the research programme. The calibration and acquisition process and the mathematical comparison algorithms were described in previous papers [C. Neumann, P. Margot, New perspectives in the use of ink evidence in forensic science-Part I: Development of a quality assurance process for forensic ink analysis by HPTLC, Forensic Sci. Int. 185 (2009) 29-37; C. Neumann, P. Margot, New perspectives in the use of ink evidence in forensic science-Part II: Development and testing of mathematical algorithms for the automatic comparison of ink samples analysed by HPTLC, Forensic Sci. Int. 185 (2009) 38-50]. In this paper, the benefits and challenges of the proposed concepts are tested in two forensic contexts: (1) ink identification and (2) ink evidential value assessment. The results show that different algorithms are better suited for different tasks. This research shows that it is possible to build digital ink libraries using the most commonly used ink analytical technique, i.e. high-performance thin layer chromatography, despite its reputation of lacking reproducibility. More importantly, it is possible to assign evidential value to ink evidence in a transparent way using a probabilistic model. It is therefore possible to move away from the traditional subjective approach, which is entirely based on experts' opinion, and which is usually not very informative. While there is room for the improvement, this report demonstrates the significant gains obtained over the traditional subjective approach for the search of ink specimens in ink databases, and the interpretation of their evidential value.
Resumo:
The book presents the state of the art in machine learning algorithms (artificial neural networks of different architectures, support vector machines, etc.) as applied to the classification and mapping of spatially distributed environmental data. Basic geostatistical algorithms are presented as well. New trends in machine learning and their application to spatial data are given, and real case studies based on environmental and pollution data are carried out. The book provides a CD-ROM with the Machine Learning Office software, including sample sets of data, that will allow both students and researchers to put the concepts rapidly to practice.
Resumo:
The research reported in this series of article aimed at (1) automating the search of questioned ink specimens in ink reference collections and (2) at evaluating the strength of ink evidence in a transparent and balanced manner. These aims require that ink samples are analysed in an accurate and reproducible way and that they are compared in an objective and automated way. This latter requirement is due to the large number of comparisons that are necessary in both scenarios. A research programme was designed to (a) develop a standard methodology for analysing ink samples in a reproducible way, (b) comparing automatically and objectively ink samples and (c) evaluate the proposed methodology in forensic contexts. This report focuses on the last of the three stages of the research programme. The calibration and acquisition process and the mathematical comparison algorithms were described in previous papers [C. Neumann, P. Margot, New perspectives in the use of ink evidence in forensic science-Part I: Development of a quality assurance process for forensic ink analysis by HPTLC, Forensic Sci. Int. 185 (2009) 29-37; C. Neumann, P. Margot, New perspectives in the use of ink evidence in forensic science-Part II: Development and testing of mathematical algorithms for the automatic comparison of ink samples analysed by HPTLC, Forensic Sci. Int. 185 (2009) 38-50]. In this paper, the benefits and challenges of the proposed concepts are tested in two forensic contexts: (1) ink identification and (2) ink evidential value assessment. The results show that different algorithms are better suited for different tasks. This research shows that it is possible to build digital ink libraries using the most commonly used ink analytical technique, i.e. high-performance thin layer chromatography, despite its reputation of lacking reproducibility. More importantly, it is possible to assign evidential value to ink evidence in a transparent way using a probabilistic model. It is therefore possible to move away from the traditional subjective approach, which is entirely based on experts' opinion, and which is usually not very informative. While there is room for the improvement, this report demonstrates the significant gains obtained over the traditional subjective approach for the search of ink specimens in ink databases, and the interpretation of their evidential value.
Resumo:
Point-of-care (POC) tests offer potentially substantial benefits for the management of infectious diseases, mainly by shortening the time to result and by making the test available at the bedside or at remote care centres. Commercial POC tests are already widely available for the diagnosis of bacterial and viral infections and for parasitic diseases, including malaria. Infectious diseases specialists and clinical microbiologists should be aware of the indications and limitations of each rapid test, so that they can use them appropriately and correctly interpret their results. The clinical applications and performance of the most relevant and commonly used POC tests are reviewed. Some of these tests exhibit insufficient sensitivity, and should therefore be coupled to confirmatory tests when the results are negative (e.g. Streptococcus pyogenes rapid antigen detection test), whereas the results of others need to be confirmed when positive (e.g. malaria). New molecular-based tests exhibit better sensitivity and specificity than former immunochromatographic assays (e.g. Streptococcus agalactiae detection). In the coming years, further evolution of POC tests may lead to new diagnostic approaches, such as panel testing, targeting not just a single pathogen, but all possible agents suspected in a specific clinical setting. To reach this goal, the development of serology-based and/or molecular-based microarrays/multiplexed tests will be needed. The availability of modern technology and new microfluidic devices will provide clinical microbiologists with the opportunity to be back at the bedside, proposing a large variety of POC tests that will allow quicker diagnosis and improved patient care.
Resumo:
Proteomics has changed the way proteins are analyzed in living systems. This approach has been applied to blood products and protein profiling has evolved in parallel with the development of techniques. The identification of proteins belonging to red blood cell, platelets or plasma was achieved at the end of the last century. Then, the questions on the applications emerged. Hence, several studies have focused on problems related to blood banking and products, such as the aging of blood products, identification of biomarkers, related diseases and the protein-protein interactions. More recently, a mass spectrometry-based proteomics approach to quality control has been applied in order to offer solutions and improve the quality of blood products. The current challenge we face is developing a closer relationship between transfusion medicine and proteomics. In this article, these issues will be approached by focusing first on the proteome identification of blood products and then on the applications and future developments within the field of proteomics and blood products.
Resumo:
Background: As part of the second generation surveillance system for HIV/Aids in Switzerland, repeated cross-sectional surveys were conducted in 1993, 1994, 1996, 2000, 2006 and 2011 among attenders of all low threshold facilities (LTFs) with needle exchange programmes and/or supervised drug consumption rooms for injection or inhalation. The number of syringes distributed to the injectors has also been measured annually since 2000. Distribution in other settings, such as pharmacies, is also monitored nationally. Methods: Periodic surveys of LTFs have been conducted using an interviewer/self-administered questionnaire structured along four themes: socio-demographic characteristics, drug consumption, risk/preventive behaviour and health. Analysis is restricted to attenders who had injected drugs during their lifetime (IDU´s). Pearson's chi-square test and trend analysis were conducted on annual aggregated data. Trend significance was assessed using Stata's non parametric test nptrend. Results: Median age of IDU´s increased from 26 years in 1993 to 40 in 2011; most are men (78%). Total yearly number of syringes distributed by LTFs has decreased by 44% in 10 years. Use of cocaine has increased (Table 1). Injection, regular use of heroin and borrowing of syringes/needles have decreased, while sharing of other material remains stable. There are fewer new injectors; more IDU´s report substitution treatment. Most attenders had ever been tested for HIV (90% in 1993, 94% in 2011). Reported prevalence of HIV remained stable around 10%; that of HCV decreased from 62% in 2000 to 42% in 2011. Conclusions: Overall, findings indicate a decrease in injection as a means of drug consumption in that population. This interpretation is supported by data from other sources, such as a national decrease in distribution from other delivery points. Switzerland's behavioural surveillance system is sustainable and allows the HIV epidemic to be monitored among this hard-to-reach population, providing information for planning and evaluation.
Resumo:
A transportable Raman spectrometer was tested for the detection of illicit drugs seized during border controls. In a first step, the analysis methodology was optimized using reference substances such as diacetylmorphine (heroin), cocaine and amphetamine (as powder or liquid forms). Adequate focalisation distance and times of analysis, influence of daylight and artificial light sources, repeatability and limits of detection were studied. In a second step the applications and limitations of the technique to detect the illicit substances in different mixtures and containers was evaluated. Transportable Raman spectroscopy was found to be adequate for a rapid screen of liquids and powders for the detection and identification of controlled substances. Additionally, it had the advantage over other portable techniques, such as ion mobility spectrometry, of being non-destructive and capable of rapid analysis of large quantities of substances through containers such as plastic bags and glass bottles.