93 resultados para Apertureless aplanatic lens
em Université de Lausanne, Switzerland
Resumo:
The main objective of WP1 of the ORAMED (Optimization of RAdiation protection for MEDical staff) project is to obtain a set of standardised data on extremity and eye lens doses for staff in interventional radiology (IR) and cardiology (IC) and to optimise staff protection. A coordinated measurement program in different hospitals in Europe will help towards this direction. This study aims at analysing the first results of the measurement campaign performed in IR and IC procedures in 34 European hospitals. The highest doses were found for pacemakers, renal angioplasties and embolisations. Left finger and wrist seem to receive the highest extremity doses, while the highest eye lens doses are measured during embolisations. Finally, it was concluded that it is difficult to find a general correlation between kerma area product and extremity or eye lens doses.
Resumo:
Background/Aims: To evaluate multifocal intraocular lens (MIOL) implantation in children. Methods: This is a retrospective study evaluating refractive, visual and safety results of MIOL in pediatric cataract surgery. Average follow-up was 25.73 ± 10.5 months. Surgery included 12 o'clock clear corneal incision, anterior capsulorhexis, lens material aspiration and MIOL implantation (SN6AD3; Alcon). Results: We included 34 cataract eyes of 26 pediatric patients aged 2-15 years, of which 14 (54%) were unilateral. Best near visual acuity (BNVA) and best distance visual acuity (BDVA) improved significantly in 100% of eyes (p = 0.0001). BDVA was above 0.8 in 31.25% (5/16) of bilateral cases. Significant stereopsis improvement was observed postoperatively in bilateral cases only (p = 0.01). Conclusion: MIOL implantation is a safe alternative to monofocal pseudophakia for pediatric cataract with a very low complication rate. Significant BNVA, BDVA and stereopsis improvement can be achieved, particularly in bilateral cases. Message: This study shows significant BDVA, BNVA and stereopsis improvement, especially in bilateral cases, after MIOL implantation for pediatric cataracts. © 2013 S. Karger AG, Basel.
Resumo:
Within the ORAMED project a coordinated measurement program for occupationally exposed medical staff was performed in different hospitals in Europe. The main objectives of ORAMED were to obtain a set of standardized data on doses for staff in interventional cardiology and radiology and to optimize staff protection. Doses were measured with thermoluminescent dosemeters on the ring finger and wrist of both hands, on legs and at the level of the eyes of the main operator performing interventional procedures. In this paper an overview of the doses per procedure measured during 646 interventional cardiology procedures is given for cardiac angiographies and angioplasties (CA/PTCA), radiofrequency ablations (RFA) and pacemaker and defibrillator implantations (PM/ICD). 31% of the monitored procedures were associated with no collective protective equipment, whereas 44% involved a ceiling screen and a table curtain. Although associated with the smallest air kerma - area product (KAP), PM/ICD procedures led to the highest doses. As expected, KAP and doses values exhibited a very large variability. The left side of the operator, most frequently the closest to the X-ray scattering region, was more exposed than his right side. An analysis of the effect of parameters influencing the doses, namely collective protective equipment, X-ray tube configuration and catheter access route, was performed on the doses normalized to KAP. Ceiling screen and table curtain were observed to reduce normalized doses by atmost a factor 4, much smaller than theoretical attenuation factors typical for such protections, i.e. from 10 to 100. This observation was understood as their inappropriate use by the operators and their non-optimized design. Configurations with tube above the patient led to higher normalized doses to the operator than tube below, but the effect of using a biplane X-ray suite was more complex to analyze. For CA/PTCA procedures, the upper part of the operator's body received higher normalized doses for radial than for femoral catheter access, by atmost a factor 5. This could be seen for cases with no collective protection. The eyes were observed to receive the maximum fraction of the annual dose limit almost as frequently as legs and hands, and clearly the most frequently, if the former 150 mSv and new 20 mSv recommended limits for the lens of the eye are considered, respectively.
Resumo:
Within the ORAMED project (Optimization of Radiation Protection of Medical Staff) a coordinated measurement program for occupationally exposed medical staff was performed in different hospitals in Europe (www.oramed-fp7.eu). The main objective was to obtain a set of standardized data on extremity and eye lens doses for staff involved in interventional radiology and cardiology and to optimize radiation protection. Special attention was given to the measurement of the doses to the eye lenses. In this paper an overview will be given of the measured eye lens doses and the main influence factors for these doses. The measured eye lens doses are extrapolated to annual doses. The extrapolations showed that monitoringof the eye lens should be performed on routine basis.
Resumo:
BACKGROUND: The activity of melanopsin containing intrinsically photosensitive ganglion retinal cells (ipRGC) can be assessed by a means of pupil responses to bright blue (appr.480 nm) light. Due to age related factors in the eye, particularly, structural changes of the lens, less light reaches retina. The aim of this study was to examine how age and in vivo measured lens transmission of blue light might affect pupil light responses, in particular, mediated by the ipRGC. METHODS: Consensual pupil responses were explored in 44 healthy subjects aged between 26 and 68 years. A pupil response was recorded to a continuous 20 s light stimulus of 660 nm (red) or 470 nm (blue) both at 300 cd/m2 intensity (14.9 and 14.8 log photons/cm2/s, respectively). Additional recordings were performed using four 470 nm stimulus intensities of 3, 30, 100 and 300 cd/m2. The baseline pupil size was measured in darkness and results were adjusted for the baseline pupil and gender. The main outcome parameters were maximal and sustained pupil contraction amplitudes and the postillumination response assessed as area under the curve (AUC) over two time-windows: early (0-10 s after light termination) and late (10-30 s after light termination). Lens transmission was measured with an ocular fluorometer. RESULTS: The sustained pupil contraction and the early poststimulus AUC correlated positively with age (p=0.02, p=0.0014, respectively) for the blue light stimulus condition only.The maximal pupil contraction amplitude did not correlate to age either for bright blue or red light stimulus conditions.Lens transmission decreased linearly with age (p<0.0001). The pupil response was stable or increased with decreasing transmission, though only significantly for the early poststimulus AUC to 300 cd/m2 light (p=0.02). CONCLUSIONS: Age did not reduce, but rather enhance pupil responses mediated by ipRGC. The age related decrease of blue light transmission led to similar results, however, the effect of age was greater on these pupil responses than that of the lens transmission. Thus there must be other age related factors such as lens scatter and/or adaptive processes influencing the ipRGC mediated pupil response enhancement observed with advancing age.
Resumo:
The specificities of multinational corporations (MNCs) have to date not been a focus area of IS research. Extant literature mostly proposes IS configurations for specific types of MNCs, following a static and prescriptive approach. Our research seeks to explain the dynamics of global IS design. It suggests a new theoretical lens for studying global IS design by applying the structural adjustment paradigm from organizational change theories. Relying on archetype theory, we conduct a longitudinal case study to theorize the dynamics of IS adaptation. We find that global IS design emerges as an organizational adaptation process to balance interpretative schemes (i.e. the organization's values and beliefs) and structural arrangements (i.e. strategic, organizational, and IS configurations). The resulting insights can be used as a basis to further explore alternative global IS designs and movements between them.
Resumo:
Purpose: IOL centration and stability after cataract surgery is of high interest for cataract surgeons and IOL-producing companies. We present a new imaging software to evaluate the centration of the rhexis and the centration of the IOL after cataract surgery.Methods: We developed, in collaboration with the Biomedical Imaging Group (BIG), EPFL, Lausanne, a new working tool in order to assess precisely outcomes after IOL-implantation, such as ideal capsulorhexis and IOL-centration. The software is a plug-in of ImageJ, a general-purpose image processing and image-analysis package. The specifications of this software are: evaluation of the rhexis-centration and evaluation the position of the IOL in the posterior chamber. The end points are to analyze the quality of the centration of a rhexis after cataract surgery, the deformation of the rhexis with capsular bag retraction and the centration of the IOL after implantation.Results: This software delivers tools to interactively measure the distances between limbus, IOL and capsulorhexis and its changes over time. The user is invited to adjust nodes of three radial curves for the limbus, rhexis and the optic of the IOL. The radial distances of the curves are computed to evaluate the IOL implantation. The user is also able to define patterns for ideal capsulorhexis and optimal IOL-centration. We are going to present examples of calculations after cataract surgery.Conclusions: Evaluation of the centration of the rhexis and of the IOL after cataract surgery is an important end point for optimal IOL implantation after cataract surgery. Especially multifocal or accommodative lenses need a precise position in the bag with a good stability over time. This software is able to evaluate these parameters just after the surgery but also its changes over time. The results of these evaluations can lead to an optimizing of surgical procedures and materials.
Resumo:
Background: The purpose of this study is to report the anatomic and functional results of primary 23 G vitrectomy using slit-lamp and non-contact 90 D lens for the treatment of pseudophakic rhegmatogenous retinal detachment. Patients and Methods: Pseudophakic eyes were operated by 23 G vitrectomy using slit-lamp and non-contact 90 D lens, internal subretinal fluid drainage, cryopexy and internal gas tamponade. The preoperative and postoperative characteristics were analysed. Main outcome measures were anatomic success rates after initial surgical intervention and after reoperation for primary failures, visual outcome at the last follow-up visit, and complications. Results: 46 pseudophakic eyes were included in this retrospective study (October 2013- January 2014). In 40 cases, sulfur hexafluoride 23 % gastamponade was used, silicone oil in 6 cases (13 %). The retina was reattached successfully after a single surgery in 44 eyes (96 %). Recurrence of retinal detachment occurred in 2 eyes. Final anatomic reattachment was obtained in 100 % after a second operation. Silicone oil was removed in all eyes. Visual acuity improved significantly from logMAR 0 (IQR 0 - 0.9) to logMAR 0 (IQR 0 - 0.2) (p < 0.005). Conclusions: Primary 23 G vitrectomy using slit-lamp and non contact 90 D lens for the treatment of pseudophakic rhegmatogenous retinal detachment provides a high anatomic and functional success rate and is associated with few complications.
Resumo:
A questionnaire was developed by the members of WG12 of EURADOS in order to establish an overview of the current status of eye lens radiation dose monitoring in hospitals. The questionnaire was sent to medical physicists and radiation protection officers in hospitals across Europe. Specific topics were addressed in the questionnaire such as: knowledge of the proposed eye lens dose limit; monitoring and dosimetry issues; training and radiation protection measures. The results of the survey highlighted that the new eye lens dose limit can be exceeded in interventional radiology procedures and that eye lens protection is crucial. Personnel should be properly trained in how to use protective equipment in order to keep eye lens doses as low as reasonably achievable. Finally, the results also highlighted the need to improve the design of eye dosemeters in order to ensure satisfactory use by workers.
Resumo:
PURPOSE: To test the ability of two preparations of FGF2-saporin, either FGF2 chemically conjugated to saporin (FGF2-SAP) or genetically engineered FGF2-saporin (rFGF2-SAP) to inhibit the growth of bovine epithelial lens (BEL) cells in vitro when in solution and when immobilized on heparin surface-modified (HSM) polymethylmethacrylate (PMMA) intraocular lenses (IOLs). METHOD: Bovine epithelial lens cells were incubated with various concentrations FGF2-saporin for as long as 4 days. The number of surviving cells was determined by counting the number of nuclei. Because FGF2 binds to heparin, FGF2-saporin was incubated with HSM PMMA IOLs; excess toxin was washed off, and the BEL cells were grown on the FGF2-saporin-treated IOLs (HSM and non-HSM) for 4 days. Cell density was determined by image analysis. RESULTS: Both FGF2-SAP and rFGF2-SAP were highly cytotoxic (nM range), with rFGF2-SAP 10 times less active than FGF2-SAP. FGF2-saporin bound to the surface of HSM IOLs and eluted by 2M NaCl retained its activity. Toxin bound to HSM IOLs killed more than 90% of the BEL cells placed on the IOL surface within 4 days. The ability of FGF2-saporin to prevent the growth of cells on the IOL surface was strictly dependent on the presence of heparin on the IOL. CONCLUSIONS: FGF2-saporin is bound to HSM PMMA IOLs and prevents the growth of epithelial cells on the surface of the lens.
Resumo:
Implantation of a phakic iris claw intraocular lens is a common, effective and safe procedure to correct high myopia, hyperopia and astigmatism [2]. Due to the nature of its fixation on the iris using claws, chronic irritation and inflammation have remained a major concern with the Artisan® lens since its market introduction in 1998. Following iris claw implantation, monitoring of postoperative inflammation is mandatory [4][7]. Usually, signs of inflammation can be detected in the anterior chamber during the early postoperative period. We present here the first case of late-onset inflammation after implantation of an iris claw lens triggered by an iris varix. The iris varix is a rare benign iris vascular abnormality, with a low prevalence as a solitary primary lesion in the general population and little is known about its clinical characteristics [1][5][6]. This report shows that an iris varix could be a cause of a late onset and chronic inflammation after phakic Artisan® lens implantation.
Resumo:
The main aim of the Work Package 1 (WP1) of the ORAMED project, Collaborative Project (2008-2011), supported by the European Commission within its 7th Framework Programme, was to obtain a set of standardized data on extremity and eye lens doses for staff in interventional radiology and cardiology (IR/IC) workplaces and to recommend a series of guidelines on radiation protection in order to both guarantee and optimize staff protection. Within the project, coordinated measurements were performed in 34 hospitals in 6 European countries. Furthermore, simulations of the most representative workplaces in IR and IC were performed to determine the main parameters that influence the extremity and eye lens doses. The work presented in this paper shows the recommendations that were formulated by the results obtained from both measurements and simulations. The presented guidelines are directed to operators, assistant personnel, radiation protection officers and medical physics experts. They concern radiation protection issues, such as the use of room protective equipment, as well as the positioning of the extremity and eye lens dosemeters for routine monitoring.