38 resultados para Amorphous silicon films

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the investigation of thin films of transition metal nitrides, an essential role is played by the accurate determination of their chemical composition. Actually the chemical composition depends on the deposition parameters and influences the optical properties. These relations are illustrated in thin films of TiNx and (Ti1-yVy)N-x deposited by reactive magnetron sputtering from composite targets of the elements. By variation of the nitrogen partial pressure and the target composition, different samples have been obtained. The chemical composition has been measured by electron probe microanalysis at low irradiation voltages. The optical properties are evaluated by ex-situ ellipsometry. Using the screened Drude model, they are correlated with the differences in composition. Adding vanadium or nitrogen in Ti-N is shown to have the same effect on the optical properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dans cet ouvrage, l'auteur propose une conceptualisation théorique de la coprésence en un même film de mondes multiples en abordant différents paramètres (hétérogénéité de la facture de l'image, pratiques du montage alterné, typologie des enchâssements, expansion sérielle, etc.) sur la base d'un corpus de films de fiction récents qui appartiennent pour la plupart au genre de la science-fiction (Matrix, Dark City, Avalon, Resident Evil, Avatar,...). Issue de la filmologie, la notion de « diégèse » y est développée à la fois dans le potentiel d'autonomisation dont témoigne la conception mondaine qui semble dominer aujourd'hui à l'ère des jeux vidéo, dans ses liens avec le récit et dans une perspective intermédiale. Les films discutés ont la particularité de mettre en scène des machines permettant aux personnages de passer d'un monde à l'autre : les modes de figuration de ces technologies sont investigués en lien avec les imaginaires du dispositif cinématographique et les potentialité du montage. La comparaison entre les films (Tron et son récent sequel, Totall Recall et son remake) et entre des oeuvres filmiques et littéraires (en particulier les nouvelles de Philip K. Dick et Simlacron 3 de Galouye) constitue un outil d'analyse permettant de saisir la contemporanéité de cette problématique, envisagée sur le plan esthétique dans le contexte de l'imagerie numérique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'article se propose de discuter la question des modalités de la référence aux évangiles au cinéma en s'attachant à l'étude de la composante verbale et de ses liens avec la représentation de la figure christique dans deux films: le premier, Ben-Hur (Fred Niblo, 1925), est une superproduction produite par Hollywood à l'époque de l'apogée du muet; le second, Golgotha (1935), est réalisé par le cinéaste français Julien Duvivier durant les premières années de la généralisation du parlant. D'un côté l'écrit (sous forme d'intertitres), de l'autre la profération orale d'un texte. Le rapprochement proposé entre ces deux films tient à la façon dont la citation néotestamentaire participe à la construction par le film de la figure de Jésus, ou plutôt à la mise à distance de celle-ci, constamment rejetée dans une forme de hors-champ.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In many European countries, image quality for digital x-ray systems used in screening mammography is currently specified using a threshold-detail detectability method. This is a two-part study that proposes an alternative method based on calculated detectability for a model observer: the first part of the work presents a characterization of the systems. Eleven digital mammography systems were included in the study; four computed radiography (CR) systems, and a group of seven digital radiography (DR) detectors, composed of three amorphous selenium-based detectors, three caesium iodide scintillator systems and a silicon wafer-based photon counting system. The technical parameters assessed included the system response curve, detector uniformity error, pre-sampling modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE). Approximate quantum noise limited exposure range was examined using a separation of noise sources based upon standard deviation. Noise separation showed that electronic noise was the dominant noise at low detector air kerma for three systems; the remaining systems showed quantum noise limited behaviour between 12.5 and 380 µGy. Greater variation in detector MTF was found for the DR group compared to the CR systems; MTF at 5 mm(-1) varied from 0.08 to 0.23 for the CR detectors against a range of 0.16-0.64 for the DR units. The needle CR detector had a higher MTF, lower NNPS and higher DQE at 5 mm(-1) than the powder CR phosphors. DQE at 5 mm(-1) ranged from 0.02 to 0.20 for the CR systems, while DQE at 5 mm(-1) for the DR group ranged from 0.04 to 0.41, indicating higher DQE for the DR detectors and needle CR system than for the powder CR phosphor systems. The technical evaluation section of the study showed that the digital mammography systems were well set up and exhibiting typical performance for the detector technology employed in the respective systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Neuroticism is a personality component frequently found in anxious and depressive psychiatric disorders. The influence of neuroticism on negative emotions could be due to its action on stimuli related to fear and sadness, but this remains debated. Our goal was thus to better understand the impact of neuroticism through verbal and physiological assessment in response to stimuli inducing fear and sadness as compared to another negative emotion (disgust).¦Methods: Fifteen low neurotic and 18 high neurotic subjects were assessed on an emotional attending task by using film excerpts inducing fear, disgust, and sadness. We recorded skin conductance response (SCR) and corrugator muscle activity (frowning) as indices of emotional expression.¦Results: SCR was larger in high neurotic subjects than in low neurotics for fear relative to sadness and disgust. Moreover, corrugator activity and SCR were larger in high than in low neurotic subjects when fear was induced.¦Conclusion: After decades of evidence that individuals higher in neuroticism experience more intense emotional reactions to even minor stressors, our results indicate that they show greater SCR and expressive reactivity specifically to stimuli evoking fear rather than to those inducing sadness or disgust. Fear processing seems mainly under the influence of neuroticism. This modulation of autonomic activity by neurotics in response to threat/fear may explain their increased vulnerability to anxious psychopathologies such as PTSD (post traumatic stress disorder).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a silicon chip-based approach for the enhanced sensitivity detection of surface-immobilized fluorescent molecules. Green fluorescent protein (GFP) is bound to the silicon substrate by a disuccinimidyl terephtalate-aminosilane immobilization procedure. The immobilized organic layers are characterized by surface analysis techniques, like ellipsometry, atomic force microscopy (AFM) and X-ray induced photoelectron spectroscopy. We obtain a 20-fold enhancement of the fluorescent signal, using constructive interference effects in a fused silica dielectric layer, deposited before immobilization onto the silicon. Our method opens perspectives to increase by an order of magnitude the fluorescent response of surface immobilized DNA- or protein-based layers for a variety of biosensor applications.