17 resultados para After-images.
em Université de Lausanne, Switzerland
Resumo:
To compare autofluorescence (AF) images obtained with the confocal scanning laser ophthalmoscope (using the Heidelberg retina angiograph; HRA) and the modified Topcon fundus camera, in a routine clinical setting. A prospective comparative study conducted at the Jules-Gonin Eye Hospital. Fifty-six patients from the medical retina clinic. All patients had complete ophthalmic slit-lamp and fundus examinations, colour and red-free fundus photography, AF imaging with both instruments, and fluorescein angiography. Cataract and fixation were graded clinically. AF patterns were analyzed for healthy and pathological features. Differences of image noise were analyzed by cataract grading and fixation. A total of 105 eyes were included. AF patterns discovered by the retina angiograph and the fundus camera images, respectively, were a dark optic disc in 72 % versus 15 %, a dark fovea in 92 % versus 4 %, sub- and intraretinal fluid visible as hyperautofluorescence on HRA images only, lipid exudates visible as hypoautofluorescence on HRA images only. The same autofluorescent pattern was found on both images for geographic atrophy, retinal pigment changes, drusen and haemorrhage. Image noise was significantly associated with the degree of cataract and/or poor fixation, favouring the fundus camera. Images acquired by the fundus camera before and after fluorescein angiography were identical. Fundus AF images differ according to the technical differences of the instruments used. Knowledge of these differences is important not only for correctly interpreting images, but also for selecting the most appropriate instrument for the clinical situation.
Resumo:
BACKGROUND AND PURPOSE: The posterior circulation Acute Stroke Prognosis Early CT Score (pc-ASPECTS) quantifies the extent of early ischemic changes in the posterior circulation with a 10-point grading system. We hypothesized that pc-ASPECTS applied to CT angiography source images predicts functional outcome of patients in the Basilar Artery International Cooperation Study (BASICS). METHODS: BASICS was a prospective, observational registry of consecutive patients with acute symptomatic basilar artery occlusion. Functional outcome was assessed at 1 month. We applied pc-ASPECTS to CT angiography source images of patients with CT angiography for confirmation of basilar artery occlusion. We calculated unadjusted and adjusted risk ratios (RRs) of pc-ASPECTS dichotomized at ≥8 versus <8. Primary outcome measure was favorable outcome (modified Rankin Scale scores 0-3). Secondary outcome measures were mortality and functional independence (modified Rankin Scale scores 0-2). RESULTS: Of 158 patients included, 78 patients had a CT angiography source images pc-ASPECTS≥8. Patients with a pc-ASPECTS≥8 more often had a favorable outcome than patients with a pc-ASPECTS<8 (crude RR, 1.7; 95% CI, 0.98-3.0). After adjustment for age, baseline National Institutes of Health Stroke Scale score, and thrombolysis, pc-ASPECTS≥8 was not related to favorable outcome (RR, 1.3; 95% CI, 0.8-2.2), but it was related to reduced mortality (RR, 0.7; 95% CI, 0.5-0.98) and functional independence (RR, 2.0; 95% CI, 1.1-3.8). In post hoc analysis, pc-ASPECTS dichotomized at ≥6 versus <6 predicted a favorable outcome (adjusted RR, 3.1; 95% CI, 1.2-7.5). CONCLUSIONS: pc-ASPECTS on CT angiography source images independently predicted death and functional independence at 1 month in the CT angiography subgroup of patients in the BASICS registry.
Resumo:
Successful detection of inflammatory lesions by planar scintigraphy and SPECT after injection of iodine-123 labelled monoclonal antibodies directed against human granulocytes (123I-Mabgc) is demonstrated. This new tracer has been compared with indium-111 labelled white blood cells (111In-WBC) in selected patients with proven infectious lesions. Scans were equally positive in all cases, but the methodical advantages of the new marker were obvious, namely, there is no need for cell separation and the images of inflammatory lesions were better defined. In addition, SPECT could be performed with 123I-Mabgc and allowed a better anatomic localization and a three-dimensional description of the lesions. No adverse reactions have been seen. It is concluded, therefore, that 123I-Mabgc is a promising agent for the detection of acute focal inflammatory lesions which may, with advantages, replace 111In-WBC.
Resumo:
OBJECTIVE: To test the ability of a novel phase-shifting medium (PSM) to provide sustained distension of the uterine cavity and produce saline infusion sonography (SIS)-like images in a simplified contrast ultrasound procedure. DESIGN: Prospective pilot feasibility trial of a new diagnostic procedure, contrast ultrasound. SETTING: Clinical reproductive endocrine and infertility unit of regional teaching hospital. PATIENT(S): Twenty-six asymptomatic infertile women (group I) and 27 women presenting with dysfunctional uterine bleeding (DUB) who were scheduled for exploratory surgery (group II). INTERVENTION(S): All women who were temporarily on oral contraceptive first had a regular pelvic ultrasound followed by the intrauterine instillation of up to 3 mL PSM, using a regular insemination catheter, after which all instruments were removed and a regular ultrasound was performed again. RESULT(S): In all 53 women, intrauterine instillation of 1-3 mL PSM resulted in a 3-7 mm uterine distension, sufficient to produce SIS-like images of the uterine cavity that lasted 7-10 min. Contrast ultrasound revealed an endometrial polyp in 3 asymptomatic women of group I. In group II. 12 of 14 women (86%) whose vaginal ultrasound were positive or dubious had positive findings with contrast ultrasound; 9 of 12 patients whose vaginal ultrasounds were negative also had positive contrast ultrasound findings. All the positive and negative findings of contrast ultrasound made in group II were confirmed anatomically (sensitivity and specificity of 100%), whereas the correlation for standard vaginal ultrasound was markedly lower at 57.1% and 85.7%, respectively. Most patients (46 of 53) reported no discomfort during or after the procedure, and 7 women described the procedure as mildly uncomfortable. CONCLUSION(S): Contrast ultrasound, a novel simple diagnostic procedure conducted after intrauterine instillation of 1-3 mL PSM using a simple plastic catheter, delivered SIS-quality images in asymptomatic (group I) and symptomatic (group II) patients while retaining the simplicity of standard ultrasound. We therefore foresee broad application of contrast ultrasound for sensitive and specific assessment for uterine pathologies in the physician's office.
Resumo:
PURPOSE: Cardiovascular magnetic resonance (CMR) has become a robust and important diagnostic imaging modality in cardiovascular medicine. However,insufficient image quality may compromise its diagnostic accuracy. No standardized criteria are available to assess the quality of CMR studies. We aimed todescribe and validate standardized criteria to evaluate the quality of CMR studies including: a) cine steady-state free precession, b) delayed gadoliniumenhancement, and c) adenosine stress first-pass perfusion. These criteria will serve for the assessment of the image quality in the setting of the Euro-CMR registry.METHOD AND MATERIALS: First, a total of 45 quality criteria were defined (35 qualitative criteria with a score from 0-3, and 10 quantitative criteria). Thequalitative score ranged from 0 to 105. The lower the qualitative score, the better the quality. The quantitative criteria were based on the absolute signal intensity (delayed enhancement) and on the signal increase (perfusion) of the anterior/posterior left ventricular wall after gadolinium injection. These criteria were then applied in 30 patients scanned with a 1.5T system and in 15 patients scanned with a 3.0T system. The examinations were jointly interpreted by 3 CMR experts and 1 study nurse. In these 45 patients the correlation between the results of the quality assessment obtained by the different readers was calculated.RESULTS: On the 1.5T machine, the mean quality score was 3.5. The mean difference between each pair of observers was 0.2 (5.7%) with a mean standarddeviation of 1.4. On the 3.0T machine, the mean quality score was 4.4. The mean difference between each pair of onservers was 0.3 (6.4%) with a meanstandard deviation of 1.6. The quantitative quality assessments between observers were well correlated for the 1.5T machine: R was between 0.78 and 0.99 (pCONCLUSION: The described criteria for the assessment of CMR image quality are robust and have a low inter-observer variability, especially on 1.5T systems.CLINICAL RELEVANCE/APPLICATION: These criteria will allow the standardization of CMR examinations. They will help to improve the overall quality ofexaminations and the comparison between clinical studies.
Resumo:
OBJECTIVE: To determine the usefulness of computed tomography (CT), magnetic resonance imaging (MRI), and Doppler ultrasonography (US) in providing specific images of gouty tophi. METHODS: Four male patients with chronic gout with tophi affecting the knee joints (three cases) or the olecranon processes of the elbows (one case) were assessed. Crystallographic analyses of the synovial fluid or tissue aspirates of the areas of interest were made with polarising light microscopy, alizarin red staining, and x ray diffraction. CT was performed with a GE scanner, MR imaging was obtained with a 1.5 T Magneton (Siemens), and ultrasonography with colour Doppler was carried out by standard technique. RESULTS: Crystallographic analyses showed monosodium urate (MSU) crystals in the specimens of the four patients; hydroxyapatite and calcium pyrophosphate dihydrate (CPPD) crystals were not found. A diffuse soft tissue thickening was seen on plain radiographs but no calcifications or ossifications of the tophi. CT disclosed lesions containing round and oval opacities, with a mean density of about 160 Hounsfield units (HU). With MRI, lesions were of low to intermediate signal intensity on T(1) and T(2) weighting. After contrast injection in two cases, enhancement of the tophus was seen in one. Colour Doppler US showed the tophi to be hypoechogenic with peripheral increase of the blood flow in three cases. CONCLUSION: The MR and colour Doppler US images showed the tophi as masses surrounded by a hypervascular area, which cannot be considered as specific for gout. But on CT images, masses of about 160 HU density were clearly seen, which correspond to MSU crystal deposits.
Resumo:
The aim of the present study was to explore the prevalence of acute cerebrovascular symptoms temporally related to carotid Doppler examination (DEx), in order to increase the awareness and recording of such events and to discuss possible mechanisms. All adult patients who complained of acute onset neurologic symptoms during or shortly after a carotid DEx, between 01/2003 and 12/2011 in the University Hospital of Lausanne were prospectively collected. We identified four consecutive patients with acute onset neurologic symptoms during or shortly after a carotid DEx among approximately 13,500 patients who underwent carotid DEx in our facility during the nine-year period (0.015% of all examined carotids). Clinical data, imaging reports and CTA (CT angiography) or/and ultrasound images are presented for each patient. Ischemic cerebrovascular events during or immediately after cervical Doppler could be due to chance or to several physical factors. They should be promptly recognized by Doppler personnel and properly treated, but do not put into question the overwhelming benefits of Doppler in cerebrovascular patients.
Resumo:
This clinical study was based on experimental results obtained in nude mice grafted with human colon carcinoma, showing that injected 131I-labeled F(ab')2 and Fab fragments from high affinity anti-carcinoembryonic antigen (CEA) monoclonal antibodies (MAb) gave markedly higher ratios of tumor to normal tissue localization than intact MAb. 31 patients with known colorectal carcinoma, including 10 primary tumors, 13 local tumor recurrences, and 21 metastatic involvements, were injected with 123I-labeled F(ab')2 (n = 14) or Fab (n = 17) fragments from MAb anti-CEA. The patients were examined by emission-computerized tomography (ECT) at 6, 24, and sometimes 48 h after injection using a rotating dual head scintillation camera. All 23 primary tumors and local recurrences except one were clearly visualized on at least two sections of different tomographic planes. Interestingly, nine of these patients had almost normal circulating CEA levels, and three of the visualized tumors weighed only 3-5 g. Among 19 known metastatic tumor involvements, 14 were correctly localized by ECT. Two additional liver and several bone metastases were discovered by immunoscintigraphy. Altogether, 86% of the tumor sites were detected, 82% with F(ab')2 and 89% with Fab fragments. The contrast of the tumor images obtained with Fab fragments suggests that this improved method of immunoscintigraphy has the potential to detect early tumor recurrences and thus to increase the survival of patients. The results of this retrospective study, however, should be confirmed in a prospective study before this method can be recommended for the routine diagnosis of cancer.
Resumo:
A better prediction of the outcome after ischemia and estimation of onset time at early time points would greatly facilitate clinical decisions. Therefore, the aim of the present study was to use magnetic resonance spectroscopy to identify neurochemical markers for outcome prediction at early time points after ischemia.ICR-CD1 mice were subjected to 10-minute, 30-minute or permanent middle cerebral artery occlusion (MCAO). The regional cerebral blood flow (CBF) was monitored in all animals by laser-Doppler flowmetry. All MR studies were carried out in a horizontal 14.1T magnet. Fast spin echo images with T2-weighted parameters were Bacquired to localize the volume of interest and evaluate the lesion size. Immediately after adjustment of field inhomogeneities, localized 1H MRS was applied to obtain the neurochemical profile from the striatum (6-8 μl) or the cortex (2.2-2.5 μl). Six animals (sham group) underwent nearly identical procedures without MCAO.By comparing the evolution of several metabolites in ischemia of varying severity, we observed that glutamine increases early after transient ischemia independently of severity, but decreases in permanent ischemia. On the opposite, GABA increased in permanent ischemia and decreased in transient. We also observed a decrease in the sum of N-acetyl aspartate + glutamate + taurine in all irreversibly damaged tissues, independently of reperfusion and severity. Finally, we have observed that some metabolites decrease exponentially after ischemia. This exponential decrease could be used to determine the time of ischemia onset in permanent ischemia.In Conclusion, magnetic resonance spectroscopy can be used as a prognostic and diagnostic tool to monitor reperfusion, identify reversibly and irreversibly damaged tissue and evaluate the time of ischemia onset. If these Results can be translated to stroke patients, this technique would greatly improve the diagnosis and help with clinical decisions.
Endoscopic extraction of a prevertebral migrated guidewire after posterior cervical instrumentation.
Resumo:
Images of Spine Care
Resumo:
BACKGROUND: Hippocampal atrophy (HA) is a known predictor of dementia in Alzheimer's disease. HA has been found in advanced Parkinson's disease (PD), but no predicting value has been demonstrated yet. The identification of such a predictor in candidates for subthalamic deep brain stimulation (STN-DBS) would be of value. Our objective was to compare preoperative hippocampal volumes (HV) between PD patients who subsequently converted to dementia (PDD) after STN-DBS and those who did not (PDnD). METHODS: From a cohort of 70 consecutive STN-DBS treated PD patients, 14 converted to dementia over 25.6+/-20.2 months (PDD). They were compared to 14 matched controls (PDnD) who did not convert to dementia after 43.9+/-11.7 months. On the preoperative 3D MPRAGE MRI images, HV and total brain volumes (TBV) were measured by a blinded investigator using manual and automatic segmentation respectively. RESULTS: PDD had smaller preoperative HV than PDnD (1.95+/-0.29 ml; 2.28+/-0.33 ml; p<0.01). This difference reinforced after normalization for TBV (3.28+/-0.48, 3.93+/-0.60; p<0.01). Every 0.1 ml decrease of HV increased the likelihood to develop dementia by 24.6%. A large overlap was found between PD and PDnD HVs, precluding the identification of a cut-off score. CONCLUSIONS: As in Alzheimer's disease, HA may be a predictor of the conversion to dementia in PD. This preoperative predictor suggests that the development of dementia after STN-DBS is related to the disease progression, rather then the procedure. Further studies are needed to define a cut-off score for HA, in order to affine its predictive value for an individual patient.
Resumo:
We propose to evaluate automatic three-dimensional gray-value rigid registration (RR) methods for prostate localization on cone-beam computed tomography (CBCT) scans. In total, 103 CBCT scans of 9 prostate patients have been analyzed. Each one was registered to the planning CT scan using different methods: (a) global RR, (b) pelvis bone structure RR, (c) bone RR refined by local soft-tissue RR using the CT clinical target volume (CTV) expanded with a 1, 3, 5, 8, 10, 12, 15 or 20-mm margin. To evaluate results, a radiation oncologist was asked to manually delineate the CTV on the CBCT scans. The Dice coefficients between each automatic CBCT segmentation - derived from the transformation of the manual CT segmentation - and the manual CBCT segmentation were calculated. Global or bone CT/CBCT RR has been shown to yield insufficient results in average. Local RR with an 8-mm margin around the CTV after bone RR was found to be the best candidate for systematically significantly improving prostate localization.
Resumo:
OBJECTIVE: The objective of our study was to establish optimal perfusion conditions for high-resolution postmortem angiography that would permit dynamic visualization of the arterial and venous systems. MATERIALS AND METHODS: Cadavers of two dogs and one cat were perfused with diesel oil through a peristaltic pump. The lipophilic contrast agent Lipiodol Ultra Fluide was then injected, and angiography was performed. The efficiency of perfusion was evaluated in the chick chorioallantoic membrane. RESULTS: Vessels could be seen up to the level of the smaller supplying and draining vessels. Hence, both the arterial and the venous sides of the vascular system could be distinguished. The chorioallantoic membrane assay revealed that diesel oil enters microvessels up to 50 microm in diameter and that it does not penetrate the capillary network. CONCLUSION: After establishing a postmortem circulation by diesel oil perfusion, angiography can be performed by injection of Lipiodol Ultra Fluide. The resolution of the images obtained up to 3 days after death is comparable to that achieved in clinical angiography.
Resumo:
Matrix sublimation has demonstrated to be a powerful approach for high-resolution matrix-assisted laser desorption ionization (MALDI) imaging of lipids, providing very homogeneous solvent-free deposition. This work presents a comprehensive study aiming to evaluate current and novel matrix candidates for high spatial resolution MALDI imaging mass spectrometry of lipids from tissue section after deposition by sublimation. For this purpose, 12 matrices including 2,5-dihydroxybenzoic acid (DHB), sinapinic acid (SA), α-cyano-4-hydroxycinnamic acid (CHCA), 2,6-dihydroxyacetphenone (DHA), 2',4',6'-trihydroxyacetophenone (THAP), 3-hydroxypicolinic acid (3-HPA), 1,8-bis(dimethylamino)naphthalene (DMAN), 1,8,9-anthracentriol (DIT), 1,5-diaminonapthalene (DAN), p-nitroaniline (NIT), 9-aminoacridine (9-AA), and 2-mercaptobenzothiazole (MBT) were investigated for lipid detection efficiency in both positive and negative ionization modes, matrix interferences, and stability under vacuum. For the most relevant matrices, ion maps of the different lipid species were obtained from tissue sections at high spatial resolution and the detected peaks were characterized by matrix-assisted laser desorption ionization time-of-flight/time-of-flight (MALDI-TOF/TOF) mass spectrometry. First proposed for imaging mass spectrometry (IMS) after sublimation, DAN has demonstrated to be of high efficiency providing rich lipid signatures in both positive and negative polarities with high vacuum stability and sub-20 μm resolution capacity. Ion images from adult mouse brain were generated with a 10 μm scanning resolution. Furthermore, ion images from adult mouse brain and whole-body fish tissue sections were also acquired in both polarity modes from the same tissue section at 100 μm spatial resolution. Sublimation of DAN represents an interesting approach to improve information with respect to currently employed matrices providing a deeper analysis of the lipidome by IMS.
Resumo:
Normal and abnormal brains can be segmented by registering the target image with an atlas. Here, an atlas is defined as the combination of an intensity image (template) and its segmented image (the atlas labels). After registering the atlas template and the target image, the atlas labels are propagated to the target image. We define this process as atlas-based segmentation. In recent years, researchers have investigated registration algorithms to match atlases to query subjects and also strategies for atlas construction. In this paper we present a review of the automated approaches for atlas-based segmentation of magnetic resonance brain images. We aim to point out the strengths and weaknesses of atlas-based methods and suggest new research directions. We use two different criteria to present the methods. First, we refer to the algorithms according to their atlas-based strategy: label propagation, multi-atlas methods, and probabilistic techniques. Subsequently, we classify the methods according to their medical target: the brain and its internal structures, tissue segmentation in healthy subjects, tissue segmentation in fetus, neonates and elderly subjects, and segmentation of damaged brains. A quantitative comparison of the results reported in the literature is also presented.