48 resultados para Adhesive phenol-formaldehyde

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study is to create a standard test to approve the efficacy of a surgical sealant. An industrial test, the bulge-and-blister test, which is very convenient for measuring adhesion energy, is applied to the surgical field to quantify adhesion of bioadhesives. METHODS: Samples were composed of two circular layers of equine pericardium glued by the surgical sealant studied. The sample was fixed to a support with an industrial glue. The support and the bottom layer were perforated in the centre to allow injection of pressurised water. Water was progressively introduced through the hole in the support and the bottom layer to create a blister with constant radius, increasing height and internal pressure during this first step. At a critical pressure, delamination started, the radius and height of the blister increased and the pressure decreased. At this point, the adhesion energy could be determined. The experimental parameters were measured with a pressure sensor and an optical profilometry device for deflection. RESULTS: Adhesion testing was carried out in eight paired equine pericardium samples bonded with a Dermabond cyanoacrylate glue. The average value of the practical adhesion energy is 2.3 Jm(-2) with a standard deviation of 1.5 Jm(-2). CONCLUSION: Application of the bulge-and-blister test to the surgical field was achieved and allowed a quantification of adhesion of a surgical glue. Such information is essential to compare the different surgical glues presently available. The study of the impact of bonding conditions such as pressure, hygrometry or setting conditions will provide a better understanding of the characteristics of adhesion in the surgical field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: CD44 represents a heterogeneous group of surface glycoproteins involved in cell-cell and cell-matrix interactions. CD44H is the major receptor for hyaluronate, and most if not all CD44H known functions are attributed to its ability to recognize hyaluronate. We have previously demonstrated a lack of CD44 expression in high stages and NMYC-amplified tumors and further have shown that NMYC-amplified cell lines either did not express CD44 at all or expressed a nonfunctional receptor. On the other hand, nonamplified cells constitutively expressed an active receptor, suggesting that absence of CD44-mediated hy aluronate binding could be related to increased malignancy in human neuroblastoma. PROCEDURE: In the present study we have compared the glycosylated structure of CD44 expressed by NMYC amplified vs. nonamplified cell lines in relation to their adhesive properties for hyaluronate. These adhesive properties were measured after modifications of the carbohydrate structure with enzymes and inhibitors of N- or O-linked glycosylation. RESULTS AND CONCLUSIONS: Our results indicate that increased sialylation, defective N-linked glycosylation, and substitution of the CD44 glycoprotein with keratan sulfate glycosaminoglycan might include modifications observed on neuroblastoma cells that could account for the inability of the receptor to bind hyaluronate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Strong platelet activation results in a redistribution of negatively charged phospholipids from the cytosolic to the outer leaflet of the cellular membrane. Annexin V has a high affinity to negatively charged phospholipids and can be used to identify procoagulant platelets. Formaldehyde fixation can cause factitious Annexin V binding. Our aim was to evaluate a method for fixing platelets avoiding additional Annexin V binding. We induced expression of negatively charged phospholipids on the surface of a fraction of platelets by combined activation with convulxin and thrombin in the presence of Annexin V-fluorescein isothiocyanate and calcium. Aliquots of resting and activated platelets were fixed with a low concentration, calcium-free formaldehyde solution. Both native platelets and fixed platelets were analyzed by flow cytometry immediately and after a 24-h storage at 4°C. We observed that the percentage of Annexin V positive resting platelets ranged from 1.5 to 9.3% for the native samples and from 0.4 to 12.8% for the fixed samples (P=0.706, paired t-test). The amount of Annexin V positive convulxin/thrombin activated platelets varied from 12.9 to 35.4% without fixation and from 15.3 to 36.3% after formalin fixation (P=0.450). After a 24-h storage at 4°C, Annexin V positive platelets significantly increased both in the resting and in the convulxin/thrombin activated samples of native platelets (both P<0.001), while results for formalin fixed platelets did not differ from baseline values (P=0.318 for resting fixed platelets; P=0.673 for activated fixed platelets). We conclude that platelet fixation with a low concentration, calcium-free formaldehyde solution does not alter the proportion of Annexin V positive platelets. This method can be used to investigate properties of procoagulant platelets by multicolor flow-cytometric analysis requiring fixation steps.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the variability of bond strength test results of adhesive systems (AS) and to correlate the results with clinical parameters of clinical studies investigating cervical restorations. MATERIALS AND METHODS: Regarding the clinical studies, the internal database which had previously been used for a meta-analysis on cervical restorations was updated with clinical studies published between 2008 and 2012 by searching the PubMed and SCOPUS databases. PubMed and the International Association for Dental Research abstracts online were searched for laboratory studies on microtensile, macrotensile and macroshear bond strength tests. The inclusion criteria were (1) dentin, (2) testing of at least four adhesive systems, (3) same diameter of composite and (4) 24h of water storage prior to testing. The clinical outcome variables were retention loss, marginal discoloration, detectable margins, and a clinical index comprising the three parameters by weighing them. Linear mixed models which included a random study effect were calculated for both, the laboratory and the clinical studies. The variability was assessed by calculating a ratio of variances, dividing the variance among the estimated bonding effects obtained in the linear mixed models by the sum of all variance components estimated in these models. RESULTS: Thirty-two laboratory studies fulfilled the inclusion criteria comprising 183 experiments. Of those, 86 used the microtensile test evaluating 22 adhesive systems (AS). Twenty-seven used the macrotensile test with 17 AS, and 70 used the macroshear test with 24 AS. For 28 AS the results from clinical studies were available. Microtensile and macrotensile (Spearman rho=0.66, p=0.007) were moderately correlated and also microtensile and macroshear (Spearman rho=0.51, p=0.03) but not macroshear and macrotensile (Spearman rho=0.34, p=0.22). The effect of the adhesive system was significant for microtensile and macroshear (p<0.001) but not for macrotensile. The effect of the adhesive system could explain 36% of the variability of the microtensile test, 27% of the macrotensile and 33% of the macroshear test. For the clinical trials, about 49% of the variability of retained restorations could be explained by the adhesive system. With respect to the correlation between bond strength tests and clinical parameters, only a moderate correlation between micro- and macrotensile test results and marginal discoloration was demonstrated. However, no correlation between these tests and a retention loss or marginal integrity was shown. The correlation improved when more studies were included compared to assessing only one study. SIGNIFICANCE: The high variability of bond strength test results highlights the need to establish individual acceptance levels for a given test institute. The weak correlation of bond-strength test results with clinical parameters leads to the conclusion that one should not rely solely on bond strength tests to predict the clinical performance of an adhesive system but one should conduct other laboratory tests like tests on the marginal adaptation of fillings in extracted teeth and the retention loss of restorations in non-retentive cavities after artificial aging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Animal models of infective endocarditis (IE) induced by high-grade bacteremia revealed the pathogenic roles of Staphylococcus aureus surface adhesins and platelet aggregation in the infection process. In humans, however, S. aureus IE possibly occurs through repeated bouts of low-grade bacteremia from a colonized site or intravenous device. Here we used a rat model of IE induced by continuous low-grade bacteremia to explore further the contributions of S. aureus virulence factors to the initiation of IE. Rats with aortic vegetations were inoculated by continuous intravenous infusion (0.0017 ml/min over 10 h) with 10(6) CFU of Lactococcus lactis pIL253 or a recombinant L. lactis strain expressing an individual S. aureus surface protein (ClfA, FnbpA, BCD, or SdrE) conferring a particular adhesive or platelet aggregation property. Vegetation infection was assessed 24 h later. Plasma was collected at 0, 2, and 6 h postinoculation to quantify the expression of tumor necrosis factor (TNF), interleukin 1α (IL-1α), IL-1β, IL-6, and IL-10. The percentage of vegetation infection relative to that with strain pIL253 (11%) increased when binding to fibrinogen was conferred on L. lactis (ClfA strain) (52%; P = 0.007) and increased further with adhesion to fibronectin (FnbpA strain) (75%; P < 0.001). Expression of fibronectin binding alone was not sufficient to induce IE (BCD strain) (10% of infection). Platelet aggregation increased the risk of vegetation infection (SdrE strain) (30%). Conferring adhesion to fibrinogen and fibronectin favored IL-1β and IL-6 production. Our results, with a model of IE induced by low-grade bacteremia, resembling human disease, extend the essential role of fibrinogen binding in the initiation of S. aureus IE. Triggering of platelet aggregation or an inflammatory response may contribute to or promote the development of IE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Traumatic injuries resulting in peripheral nerve lesions often require a graft to bridge the gap. Although autologous nerve auto-graft is still the first-choice strategy in reconstructions, it has the severe disadvantage of the sacrifice of a functional nerve. Cell transplantation in a bioartificial conduit is an alternative strategy to create a favourable environment for nerve regeneration. We decided to test new fibrin nerve conduits seeded with various cell types (primary Schwann cells and adult stem cells differentiated to a Schwann cell-like phenotype) for repair of sciatic nerve injury. Two weeks after implantation, the conduits were removed and examined by immunohistochemistry for axonal regeneration (evaluated by PGP 9.5 expression) and Schwann cell presence (detected by S100 expression). The results show a significant increase in axonal regeneration in the group of fibrin seeded with Schwann cells compared with the empty fibrin conduit. Differentiated adipose-derived stem cells also enhanced regeneration distance in a similar manner to differentiated bone marrow mesenchymal stem cells. These observations suggest that adipose-derived stem cells may provide an effective cell population, without the limitations of the donor-site morbidity associated with isolation of Schwann cells, and could be a clinically translatable route towards new methods to enhance peripheral nerve repair.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Dissection during laparoscopic surgery produces smoke containing potentially toxic substances. The aim of the present study was to analyze smoke samples produced during laparoscopic colon surgery using a bipolar vessel sealing device (LigaSuretrade mark). METHODS: Four consecutive patients undergoing left-sided colectomy were enrolled in this pilot study. Smoke was produced by the use of LigaSuretrade mark. Samples (5,5l) were evacuated from the pneumoperitoneum in a closed system into a reservoir. Analysis was performed with CO2-laser-based photoacoustic spectroscopy and confirmed by a Fourier-transform infrared spectrum. The detected spectra were compared to the available spectra of known toxins. RESULTS: Samples from four laparoscopic sigmoid resections were analyzed. No relevant differences were noted regarding patient and operation characteristics. The gas samples were stable over time proven by congruent control measurements as late as 24 h after sampling. The absorption spectra differed considerably between the patients. One broad absorption line at 100 ppm indicating H2O and several unknown molecules were detected. With a sensitivity of alpha min ca 10-5 cm-1 no known toxic substances like phenol or indole were identified. CONCLUSION: The use of a vessel sealing device during laparoscopic surgery does not produce known toxic substances in relevant quantity. Further studies are needed to identify unknown molecules and to analyze gas emission under various conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. Streptococcus gallolyticus is a causative agent of infective endocarditis associated with colon cancer. Genome sequence of strain UCN34 revealed the existence of 3 pilus loci (pil1, pil2, and pil3). Pili are long filamentous structures playing a key role as adhesive organelles in many pathogens. The pil1 locus encodes 2 LPXTG proteins (Gallo2178 and Gallo2179) and 1 sortase C (Gallo2177). Gallo2179 displaying a functional collagen-binding domain was referred to as the adhesin, whereas Gallo2178 was designated as the major pilin. Methods. S. gallolyticus UCN34, Pil1(+) and Pil1(-), expressing various levels of pil1, and recombinant Lactococcus lactis strains, constitutively expressing pil1, were studied. Polyclonal antibodies raised against the putative pilin subunits Gallo2178 and Gallo2179 were used in immunoblotting and immunogold electron microscopy. The role of pil1 was tested in a rat model of endocarditis. Results. We showed that the pil1 locus (gallo2179-78-77) forms an operon differentially expressed among S. gallolyticus strains. Short pilus appendages were identified both on the surface of S. gallolyticus UCN34 and recombinant L. lactis-expressing pil1. We demonstrated that Pil1 pilus is involved in binding to collagen, biofilm formation, and virulence in experimental endocarditis. Conclusions. This study identifies Pil1 as the first virulence factor characterized in S. gallolyticus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: We examined the correlation between the quantitative margin analysis of two laboratory test methods (Berlin, Zurich) and the clinical outcome in Class V restorations. METHODS: Prospective clinical studies with an observation period of at least 18 months were searched in the literature, for which laboratory data were also available. The clinical outcome variables were retention loss, marginal discoloration, detectable margins and secondary caries. Forty-four clinical studies matched the inclusion criteria, including 34 adhesive systems for which laboratory data were also present. For both laboratory test methods and the clinical studies, an index was formulated to better compare the in vitro and in vivo results. Linear mixed models which included a random study effect were calculated. As most clinical data were available for 12 and 24 months, the main analysis was restricted to these recall intervals. RESULTS: The comparative analysis revealed a weak correlation between the clinical index and both in vitro indices. The correlation was statistically significant for the Berlin method but not for the Zurich method and only present if studies were compared which used the same composite in the in vitro and in vivo study. When defining specific cut-off values, the prognosis for the good clinical performance of an adhesive system based on in vitro results was 78% (Berlin) or 100% (Zurich). For poor performance it was 67% and 60%, respectively. No correlation was found between both in vitro methods. SIGNIFICANCE: The surrogate parameter "marginal adaptation" of restorations placed in extracted teeth has a mediocre value to predict the clinical performance of an adhesive system in cervical cavities. The composite is an important factor for a successful prediction. The comparison between in vitro/in vivo is sometimes hampered by the great variability of clinical results on the same adhesive system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For accurate and quantitative immunohistochemical localization of antigens it is crucial to know the solubility of tissue proteins and their degree of loss during processing. In this study we focused on the solubility of several cytoskeletal proteins in cat brain tissue at various ages and their loss during immunohistochemical procedures. We further examined whether fixation affected either solubility or immunocytochemical detectability of several cytoskeletal proteins. An assay was designed to measure the solubility of cytoskeletal proteins in cryostat sections. Quantity and quality of proteins lost or remaining in tissue were measured and analyzed by electrophoresis and immunoblots. Most microtubule proteins were found to be soluble in unfixed and alcohol fixed tissues. Furthermore, the microtubule proteins remaining in the tissue had a changed cellular distribution. In contrast, brain spectrin and all three neurofilament subunits were insoluble and remained in the tissue, allowing their immunocytochemical localization in alcohol-fixed tissue. Synapsin I, a protein associated with the spectrin cytoskeleton, was soluble, and aldehyde fixation is advised for its immunohistochemical localization. With aldehyde fixation, the immunoreactivity of some antibodies against neurofilament proteins was reduced in axons unveiling novel immunogenic sites in nuclei that may represent artifacts of fixation. In conclusion, protein solubility and the effects of fixation are influential factors in cytoskeletal immunohistochemistry, and should be considered before assessments for a quantitative distribution are made.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUME L'infiltration tissulaire par les cellules leucémiques, responsable de leucostase, est une complication grave de la leucémie aiguë hyperleucocytaire. Elle peut entraîner une détresse respiratoire et des troubles neurologiques de mauvais pronostic. Pendant longtemps, la prolifération intravasculaire des cellules leucémiques et l'augmentation de la viscosité étaient considérées comme en étant responsables, et le traitement reposait sur une cytoréduction rapide par leucaphérèse. Actuellement, l'interaction entre les cellules leucémiques et l'endothélium vasculaire est plutôt considérée comme la cause de ce phénomène. En effet, les cellules leucémiques peuvent induire l'expression des sélectives endothéliales. Les sélectives initient le roulement des leucocytes avant leur adhésion ferme et leur migration dans les tissus. Elles reconnaissent des ligands spécifiques exprimés à la surface des leucocytes, comme PSGL-1 qui est un ligand commun des sélectives. Cependant, plusieurs études suggèrent que d'autres ligands de la E-sélective soient exprimés par les leucocytes. L'interaction des cellules leucémiques avec la E- et la P- sélective est corrélée avec l'expression de la molécule CLA, reconnue par l'anticorps HECA-452. L'immunopurification des ligands de la E-sélective avec cet anticorps a permis d'isoler, des cellules THP1 et U937, une protéine de 170 kDa, ainsi qu'une autre protéine de 250 kDa des cellules U937, en plus de PSGL-1. Ces protéines ont également été purifiées avec la protéine de fusion Esélective/IgM. CD43 et CD44 semblent être des ligands de la E-sélective sur certaines lignées, mais leur interaction avec la E-sélective n'est pas toujours retrouvée. De plus, cette étude a permis de montrer que ces ligands de la E-sélectiné sont exprimés dans les rafts lipidiques, comme PSGL-1 et la L-sélective des neutrophiles. Ces deux nouveaux ligands sont en cours d'identification. Ils pourraient représenter une nouvelle cible dans le traitement de la leucostase, mais aussi lors d'inflammation chronique ou de métastases. ABSTRACT Leukostasis is alife-threatening complication of acute leukemia, that results from tissue infiltration of leukemic blasts that migrate out of blood flow and interfere with normal tissue functions. The process leading to these complications has been attributed to the overcrowding of leukemic cells in the microcirculation. However, leukostasis more likely results from the adhesive interactions between leukemic blasts and the endothelium. Activated endothelium express adhesion molecules like P- and E-selectin, and leukemic cells themselves can induce the expression of E-selectin on endothelial cells. Selectins are essential in initiating the rolling of intravascular cells on endothelium before firm adhesion and transmigration outside of blood vessels. They interact with specific ligands on leukocyte cell surface. P-selectin glycoprotein ligand-1 (PSGL-1) is common ligand for E-, P- and L-selectin. Recently, CD44, ESL-1 and CD44 were shown to cooperate. ìn supporting mouse neutrophil adhesion to E-selectin. Other E-selectin ligands remain to be identified in humans. Leukemic cells were screened in order to characterize human E-selectin ligands. The interactions of E- and P-selectin correlate with the expression of CLA epitope. Therefore, HECA-452 mAb that recognizes CLA was used for immunopurification. Aglycoprotein of 170 kDa was purified from THP1 and U937 cells, and a protein of 250 kDa from U937 cells. These proteins were also purified by affinity binding to E-selectin/IgM chimera. PSGL-1 bound to E-selectin as expected, but CD43 and CD44 were not always adsorbed on E-selectin chimera, depending on cell types. E-selectin ligands were also shown to be in lipid rafts in leukemic cells, like PSGL-1 and L-selectin in human neutrophils. The 170 kDa protein has been sequenced, and three interesting ligands were among the candidates: ESL-1, CD44 and podocalyxin. These ligands are under investigation, and may represent a new therapeutic target in leukostasis, inflammation or cancer metastasis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The c-Jun-N-terminal kinase (JNK) pathway has been shown to play an important role in excitotoxic neuronal death and several studies have demonstrated a neuroprotective effect of D-JNKi, a peptide inhibitor of JNK, in various models of cerebral ischemia. We have now investigated the effect of D-JNKi in a model of transient focal cerebral ischemia (90 min) induced by middle cerebral artery occlusion (MCAo) in adult male rats. D-JNKi (0.1 mg/kg), significantly decreased the volume of infarct, 3 days after cerebral ischemia. Sensorimotor and cognitive deficits were then evaluated over a period of 6 or 10 days after ischemia and infarct volumes were measured after behavioral testing. In behavioral studies, D-JNKi improved the general state of the animals as demonstrated by the attenuation of body weight loss and improvement in neurological score, as compared with animals receiving the vehicle. Moreover, D-JNKi decreased sensorimotor deficits in the adhesive removal test and improved cognitive function in the object recognition test. In contrast, D-JNKi did not significantly affect the infarct volume at day 6 and at day 10. This study shows that D-JNKi can improve functional recovery after transient focal cerebral ischemia in the rat and therefore supports the use of this molecule as a potential therapy for stroke.