8 resultados para ASHRAE Standard 55

em Université de Lausanne, Switzerland


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To investigate the accuracy of 4 clinical instruments in the detection of glaucomatous damage. Methods: 102 eyes of 55 test subjects (Age mean = 66.5yrs, range = [39; 89]) underwent Heidelberg Retinal Tomography (HRTIII), (disc area<2.43); and standard automated perimetry (SAP) using Octopus (Dynamic); Pulsar (TOP); and Moorfields Motion Displacement Test (MDT) (ESTA strategy). Eyes were separated into three groups 1) Healthy (H): IOP<21mmHg and healthy discs (clinical examination), 39 subjects, 78 eyes; 2) Glaucoma suspect (GS): Suspicious discs (clinical examination), 12 subjects, 15 eyes; 3) Glaucoma (G): progressive structural or functional loss, 14 subjects, 20 eyes. Clinical diagnostic precision was examined using the cut-off associated with the p<5% normative limit of MD (Octopus/Pulsar), PTD (MDT) and MRA (HRT) analysis. The sensitivity, specificity and accuracy were calculated for each instrument. Results: See table Conclusions: Despite the advantage of defining glaucoma suspects using clinical optic disc examination, the HRT did not yield significantly higher accuracy than functional measures. HRT, MDT and Octopus SAP yielded higher accuracy than Pulsar perimetry, although results did not reach statistical significance. Further studies are required to investigate the structure-function correlations between these instruments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Smart canula concept allows for collapsed cannula insertion, and self-expansion within a vein of the body. (A) Computational fluid dynamics, and (B) bovine experiments (76+/-3.8 kg) were performed for comparative analyses, prior to (C) the first clinical application. For an 18F access, a given flow of 4 l/min (A) resulted in a pressure drop of 49 mmHg for smart cannula versus 140 mmHg for control. The corresponding Reynolds numbers are 680 versus 1170, respectively. (B) For an access of 28F, the maximal flow for smart cannula was 5.8+/-0.5 l/min versus 4.0+/-0.1 l/min for standard (P<0.0001), for 24F 5.5+/-0.6 l/min versus 3.2+/-0.4 l/min (P<0.0001), and for 20F 4.1+/-0.3 l/min versus 1.6+/-0.3 l/min (P<0.0001). The flow obtained with the smart cannula was 270+/-45% (20F), 172+/-26% (24F), and 134+/-13% (28F) of standard (one-way ANOVA, P=0.014). (C) First clinical application (1.42 m2) with a smart cannula showed 3.55 l/min (100% predicted) without additional fluids. All three assessment steps confirm the superior performance of the smart cannula design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

QUESTIONS UNDER STUDY AND PRINCIPLES: Estimating glomerular filtration rate (GFR) in hospitalised patients with chronic kidney disease (CKD) is important for drug prescription but it remains a difficult task. The purpose of this study was to investigate the reliability of selected algorithms based on serum creatinine, cystatin C and beta-trace protein to estimate GFR and the potential added advantage of measuring muscle mass by bioimpedance. In a prospective unselected group of patients hospitalised in a general internal medicine ward with CKD, GFR was evaluated using inulin clearance as the gold standard and the algorithms of Cockcroft, MDRD, Larsson (cystatin C), White (beta-trace) and MacDonald (creatinine and muscle mass by bioimpedance). 69 patients were included in the study. Median age (interquartile range) was 80 years (73-83); weight 74.7 kg (67.0-85.6), appendicular lean mass 19.1 kg (14.9-22.3), serum creatinine 126 μmol/l (100-149), cystatin C 1.45 mg/l (1.19-1.90), beta-trace protein 1.17 mg/l (0.99-1.53) and GFR measured by inulin 30.9 ml/min (22.0-43.3). The errors in the estimation of GFR and the area under the ROC curves (95% confidence interval) relative to inulin were respectively: Cockcroft 14.3 ml/min (5.55-23.2) and 0.68 (0.55-0.81), MDRD 16.3 ml/min (6.4-27.5) and 0.76 (0.64-0.87), Larsson 12.8 ml/min (4.50-25.3) and 0.82 (0.72-0.92), White 17.6 ml/min (11.5-31.5) and 0.75 (0.63-0.87), MacDonald 32.2 ml/min (13.9-45.4) and 0.65 (0.52-0.78). Currently used algorithms overestimate GFR in hospitalised patients with CKD. As a consequence eGFR targeted prescriptions of renal-cleared drugs, might expose patients to overdosing. The best results were obtained with the Larsson algorithm. The determination of muscle mass by bioimpedance did not provide significant contributions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To estimate the prevalence of metabolically healthy obesity (MHO) according to different definitions. Population-based sample of 2803 women and 2557 men participated in the study. Metabolic abnormalities were defined using six sets of criteria, which included different combinations of the following: waist; blood pressure; total, high-density lipoprotein or low-density lipoprotein-cholesterol; triglycerides; fasting glucose; homeostasis model assessment; high-sensitivity C-reactive protein; personal history of cardiovascular, respiratory or metabolic diseases. For each set, prevalence of MHO was assessed for body mass index (BMI); waist or percent body fat. Among obese (BMI 30 kg/m(2)) participants, prevalence of MHO ranged between 3.3 and 32.1% in men and between 11.4 and 43.3% in women according to the criteria used. Using abdominal obesity, prevalence of MHO ranged between 5.7 and 36.7% (men) and 12.2 and 57.5% (women). Using percent body fat led to a prevalence of MHO ranging between 6.4 and 43.1% (men) and 12.0 and 55.5% (women). MHO participants had a lower odd of presenting a family history of type 2 diabetes. After multivariate adjustment, the odds of presenting with MHO decreased with increasing age, whereas no relationship was found with gender, alcohol consumption or tobacco smoking using most sets of criteria. Physical activity was positively related, whereas increased waist was negatively related with BMI-defined MHO. MHO prevalence varies considerably according to the criteria used, underscoring the need for a standard definition of this metabolic entity. Physical activity increases the likelihood of presenting with MHO, and MHO is associated with a lower prevalence of family history of type 2 diabetes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The writing of prescriptions is an important aspect of medical practice. This activity presents some specific problems given a danger of misinterpretation and dispensing errors in community pharmacies. The objective of this study was to determine the evolution of the prescription practice and writing quality in the outpatient clinics of our paediatric university hospital.¦METHODS: Copies of prescriptions written by physicians were collected from community pharmacies in the region of our hospital for a two-month period in 2005 and 2010. They were analysed according to standard criteria, including both formal and pharmaceutical aspects.¦RESULTS: A total of 597 handwritten prescriptions were reviewed in 2005 and 633 in 2010. They contained 1,456 drug prescriptions in 2005 and 1,348 in 2010. Fifteen drugs accounted for 80% of all prescriptions and the most common drugs were paracetamol and ibuprofen. A higher proportion of drugs were prescribed as International Nonproprietary Names (INN) or generics in 2010 (24.7%) compared with 2005 (20.9%). Of the drug prescriptions examined, 55.5% were incomplete in 2005 and 69.2% in 2010. Moreover in 2005, 3.2% were legible only with difficulty, 22.9% were ambiguous, and 3.0% contained an error. These proportions rose respectively to 5.2%, 27.8%, and 6.8% in 2010.¦CONCLUSION: This study showed that fifteen different drugs represented the majority of prescriptions, and a quarter of them were prescribed as INN or generics in 2010; and that handwritten prescriptions contained numerous omissions and preventable errors. In our hospital computerised prescribing coupled with advanced decision support is eagerly awaited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Earlobe crease (ELC) has been associated with cardiovascular diseases (CVD) or risk factors (CVRF) and could be a marker predisposing to CVD. However, most studies studied only a small number of CVRF and no complete assessment of the associations between ELC and CVRF has been performed in a single study. METHODS: Population-based study (n = 4635, 46.7 % men) conducted between 2009 and 2012 in Lausanne, Switzerland. RESULTS: Eight hundred six participants (17.4 %) had an ELC. Presence of ELC was associated with male gender and older age. After adjusting for age and gender (and medication whenever necessary), presence of ELC was significantly (p < 0.05) associated with higher levels of body mass index (BMI) [adjusted mean ± standard error: 27.0 ± 0.2 vs. 26.02 ± 0.07 kg/m(2)], triglycerides [1.40 ± 0.03 vs. 1.36 ± 0.01 mmol/L] and insulin [8.8 ± 0.2 vs. 8.3 ± 0.1 μIU/mL]; lower levels of HDL cholesterol [1.61 ± 0.02 vs. 1.64 ± 0.01 mmol/L]; higher frequency of abdominal obesity [odds ratio and (95 % confidence interval) 1.20 (1.02; 1.42)]; hypertension [1.41 (1.18; 1.67)]; diabetes [1.43 (1.15; 1.79)]; high HOMA-IR [1.19 (1.00; 1.42)]; metabolic syndrome [1.28 (1.08; 1.51)] and history of CVD [1.55 (1.21; 1.98)]. No associations were found between ELC and estimated cardiovascular risk, inflammatory or liver markers. After further adjustment on BMI, only the associations between ELC and hypertension [1.30 (1.08; 1.56)] and history of CVD [1.47 (1.14; 1.89)] remained significant. For history of CVD, further adjustment on diabetes, hypertension, total cholesterol and smoking led to similar results [1.36 (1.05; 1.77)]. CONCLUSION: In this community-based sample ELC was significantly and independently associated with hypertension and history of CVD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: To assess the differences across continental regions in terms of stroke imaging obtained for making acute revascularization therapy decisions, and to identify obstacles to participating in randomized trials involving multimodal imaging. METHODS: STroke Imaging Repository (STIR) and Virtual International Stroke Trials Archive (VISTA)-Imaging circulated an online survey through its website, through the websites of national professional societies from multiple countries as well as through email distribution lists from STIR and the above mentioned societies. RESULTS: We received responses from 223 centers (2 from Africa, 38 from Asia, 10 from Australia, 101 from Europe, 4 from Middle East, 55 from North America, 13 from South America). In combination, the sites surveyed administered acute revascularization therapy to a total of 25,326 acute stroke patients in 2012. Seventy-three percent of these patients received intravenous (i.v.) tissue plasminogen activator (tPA), and 27%, endovascular therapy. Vascular imaging was routinely obtained in 79% (152/193) of sites for endovascular therapy decisions, and also as part of standard IV tPA treatment decisions at 46% (92/198) of sites. Modality, availability and use of acute vascular and perfusion imaging before revascularization varied substantially between geographical areas. The main obstacles to participate in randomized trials involving multimodal imaging included: mainly insufficient research support and staff (50%, 79/158) and infrequent use of multimodal imaging (27%, 43/158) . CONCLUSION: There were significant variations among sites and geographical areas in terms of stroke imaging work-up used tomake decisions both for intravenous and endovascular revascularization. Clinical trials using advanced imaging as a selection tool for acute revascularization therapy should address the need for additional resources and technical support, and take into consideration the lack of routine use of such techniques in trial planning.