73 resultados para AIRBORNE ISOCYANATES

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An active, solvent-free solid sampler was developed for the collection of 1,6-hexamethylene diisocyanate (HDI) aerosol and prepolymers. The sampler was made of a filter impregnated with 1-(2-methoxyphenyl)piperazine contained in a filter holder. Interferences with HDI were observed when a set of cellulose acetate filters and a polystyrene filter holder were used; a glass fiber filter and polypropylene filter cassette gave better results. The applicability of the sampling and analytical procedure was validated with a test chamber, constructed for the dynamic generation of HDI aerosol and prepolymers in commercial two-component spray paints (Desmodur(R) N75) used in car refinishing. The particle size distribution, temporal stability, and spatial uniformity of the simulated aerosol were established in order to test the sample. The monitoring of aerosol concentrations was conducted with the solid sampler paired to the reference impinger technique (impinger flasks contained 10 mL of 0.5 mg/mL 1-(2-methoxyphenyl)piperazine in toluene) under a controlled atmosphere in the test chamber. Analyses of derivatized HDI and prepolymers were carried out by using high-performance liquid chromatography and ultraviolet detection. The correlation between the solvent-free and the impinger techniques appeared fairly good (Y = 0.979X - 0.161; R = 0.978), when the tests were conducted in the range of 0.1 to 10 times the threshold limit value (TLV) for HDI monomer and up to 60-mu-g/m3 (3 U.K. TLVs) for total -N = C = O groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On December 4th 2007, a 3-Mm3 landslide occurred along the northwestern shore of Chehalis Lake. The initiation zone is located at the intersection of the main valley slope and the northern sidewall of a prominent gully. The slope failure caused a displacement wave that ran up to 38 m on the opposite shore of the lake. The landslide is temporally associated with a rain-on-snow meteorological event which is thought to have triggered it. This paper describes the Chehalis Lake landslide and presents a comparison of discontinuity orientation datasets obtained using three techniques: field measurements, terrestrial photogrammetric 3D models and an airborne LiDAR digital elevation model to describe the orientation and characteristics of the five discontinuity sets present. The discontinuity orientation data are used to perform kinematic, surface wedge limit equilibrium and three-dimensional distinct element analyses. The kinematic and surface wedge analyses suggest that the location of the slope failure (intersection of the valley slope and a gully wall) has facilitated the development of the unstable rock mass which initiated as a planar sliding failure. Results from the three-dimensional distinct element analyses suggest that the presence, orientation and high persistence of a discontinuity set dipping obliquely to the slope were critical to the development of the landslide and led to a failure mechanism dominated by planar sliding. The three-dimensional distinct element modelling also suggests that the presence of a steeply dipping discontinuity set striking perpendicular to the slope and associated with a fault exerted a significant control on the volume and extent of the failed rock mass but not on the overall stability of the slope.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé: L'évaluation de l'exposition aux nuisances professionnelles représente une étape importante dans l'analyse de poste de travail. Les mesures directes sont rarement utilisées sur les lieux même du travail et l'exposition est souvent estimée sur base de jugements d'experts. Il y a donc un besoin important de développer des outils simples et transparents, qui puissent aider les spécialistes en hygiène industrielle dans leur prise de décision quant aux niveaux d'exposition. L'objectif de cette recherche est de développer et d'améliorer les outils de modélisation destinés à prévoir l'exposition. Dans un premier temps, une enquête a été entreprise en Suisse parmi les hygiénistes du travail afin d'identifier les besoins (types des résultats, de modèles et de paramètres observables potentiels). Il a été constaté que les modèles d'exposition ne sont guère employés dans la pratique en Suisse, l'exposition étant principalement estimée sur la base de l'expérience de l'expert. De plus, l'émissions de polluants ainsi que leur dispersion autour de la source ont été considérés comme des paramètres fondamentaux. Pour tester la flexibilité et la précision des modèles d'exposition classiques, des expériences de modélisations ont été effectuées dans des situations concrètes. En particulier, des modèles prédictifs ont été utilisés pour évaluer l'exposition professionnelle au monoxyde de carbone et la comparer aux niveaux d'exposition répertoriés dans la littérature pour des situations similaires. De même, l'exposition aux sprays imperméabilisants a été appréciée dans le contexte d'une étude épidémiologique sur une cohorte suisse. Dans ce cas, certains expériences ont été entreprises pour caractériser le taux de d'émission des sprays imperméabilisants. Ensuite un modèle classique à deux-zone a été employé pour évaluer la dispersion d'aérosol dans le champ proche et lointain pendant l'activité de sprayage. D'autres expériences ont également été effectuées pour acquérir une meilleure compréhension des processus d'émission et de dispersion d'un traceur, en se concentrant sur la caractérisation de l'exposition du champ proche. Un design expérimental a été développé pour effectuer des mesures simultanées dans plusieurs points d'une cabine d'exposition, par des instruments à lecture directe. Il a été constaté que d'un point de vue statistique, la théorie basée sur les compartiments est sensée, bien que l'attribution à un compartiment donné ne pourrait pas se faire sur la base des simples considérations géométriques. Dans une étape suivante, des données expérimentales ont été collectées sur la base des observations faites dans environ 100 lieux de travail différents: des informations sur les déterminants observés ont été associées aux mesures d'exposition des informations sur les déterminants observés ont été associé. Ces différentes données ont été employées pour améliorer le modèle d'exposition à deux zones. Un outil a donc été développé pour inclure des déterminants spécifiques dans le choix du compartiment, renforçant ainsi la fiabilité des prévisions. Toutes ces investigations ont servi à améliorer notre compréhension des outils des modélisations ainsi que leurs limitations. L'intégration de déterminants mieux adaptés aux besoins des experts devrait les inciter à employer cet outil dans leur pratique. D'ailleurs, en augmentant la qualité des outils des modélisations, cette recherche permettra non seulement d'encourager leur utilisation systématique, mais elle pourra également améliorer l'évaluation de l'exposition basée sur les jugements d'experts et, par conséquent, la protection de la santé des travailleurs. Abstract Occupational exposure assessment is an important stage in the management of chemical exposures. Few direct measurements are carried out in workplaces, and exposures are often estimated based on expert judgements. There is therefore a major requirement for simple transparent tools to help occupational health specialists to define exposure levels. The aim of the present research is to develop and improve modelling tools in order to predict exposure levels. In a first step a survey was made among professionals to define their expectations about modelling tools (what types of results, models and potential observable parameters). It was found that models are rarely used in Switzerland and that exposures are mainly estimated from past experiences of the expert. Moreover chemical emissions and their dispersion near the source have also been considered as key parameters. Experimental and modelling studies were also performed in some specific cases in order to test the flexibility and drawbacks of existing tools. In particular, models were applied to assess professional exposure to CO for different situations and compared with the exposure levels found in the literature for similar situations. Further, exposure to waterproofing sprays was studied as part of an epidemiological study on a Swiss cohort. In this case, some laboratory investigation have been undertaken to characterize the waterproofing overspray emission rate. A classical two-zone model was used to assess the aerosol dispersion in the near and far field during spraying. Experiments were also carried out to better understand the processes of emission and dispersion for tracer compounds, focusing on the characterization of near field exposure. An experimental set-up has been developed to perform simultaneous measurements through direct reading instruments in several points. It was mainly found that from a statistical point of view, the compartmental theory makes sense but the attribution to a given compartment could ñó~be done by simple geometric consideration. In a further step the experimental data were completed by observations made in about 100 different workplaces, including exposure measurements and observation of predefined determinants. The various data obtained have been used to improve an existing twocompartment exposure model. A tool was developed to include specific determinants in the choice of the compartment, thus largely improving the reliability of the predictions. All these investigations helped improving our understanding of modelling tools and identify their limitations. The integration of more accessible determinants, which are in accordance with experts needs, may indeed enhance model application for field practice. Moreover, while increasing the quality of modelling tool, this research will not only encourage their systematic use, but might also improve the conditions in which the expert judgments take place, and therefore the workers `health protection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The replacement of the HDI monomer by less volatile prepolymers is not accompanied by a decrease of the incidence of occupational asthma in Switzerland. Field measurements show that the prepolymer concentration levels may be high although the monomer is hardly detectable or complies with the norm. Our researches are focused on the improvement of generation and measurement techniques (international quality control), on the characterization of the prepolymers to study their transformation in biological media. Field surveys will be conducted to establish the prepolymer concentration profiles. We recommend for the introduction in Switzerland of threshold limit values for HDI-biuret and isocyanurate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most airborne microorganisms are natural components of our ecosystem. Soil, vegetation and animals, including humans, are sources for aerial release of these living or dead cells. In the past, assessment of airborne microorganisms was mainly restricted to occupational health concerns. Indeed, in several occupations, exposure to very high concentrations of non-infectious airborne bacteria and fungi, result in allergenic, toxic or irritant reactions. Recently, the threat of bioterrorism and pandemics have highlighted the urgent need to increase knowledge of bioaerosol ecology. More fundamentally, airborne bacterial and fungal communities begin to draw much more consideration from environmental microbiologists, who have neglected this area for a long time. This increased interest of scientists is to a great part due to the development and use of real-time PCR techniques to identify and quantify airborne microorganisms. Even if the advantages of the PCR technology are obvious, researchers are confronted with new problems. This review describes the methodological state of the art in bioaerosols field and emphasizes the future challenges and perspectives of the real-time PCR-based methods for airborne microorganism studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE:: Lactic acid bacteria (LAB) are used in food industries as probiotic agents. The aim of this study is to assess the potential health effects of airborne exposure to a mix of preblend (LAB and carbohydrate) and milk powder in workers. METHODS:: A medical questionnaire, lung function tests, and immunologic tests were carried out on 50 workers. Occupational exposure to inhalable dust and airborne LAB was measured. RESULTS:: Workers not using respiratory masks reported more symptoms of irritation than workers using protection. Workers from areas with higher levels of airborne LAB reported the most health symptoms and the immune responses of workers to LAB was higher than the immune responses of a control population. CONCLUSIONS:: Measures to reduce exposure to airborne LAB and milk powder in food industries are recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 41-year-old woman who worked in a furniture plant was admitted to hospital for acute dyspnea that had developed a few hours she marked pieces of "Alcantara" material with a heated metallic blade. The chest x-ray showed a restrictive syndrome. The lymphocyte count was high in the bronchioalveolar lavage fluid with a CD4/CD8 ratio of 0.11, leading to the diagnosis of alveolitis. Investigations at the work place allowed identification and evaluation of the causal agent. Alcantara is a synthetic fabric composed of 70% polyurethane fibers, which when burned produces isocyanate monomers. After eliminating exposure and institution of corticosteroid therapy, the outcome was good with complete recovery. The risk was eliminated by changing the work procedure. This risk has not been reported earlier for furniture manufacture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Miniature diffusion size classifiers (miniDiSC) are novel handheld devices to measure ultrafine particles (UFP). UFP have been linked to the development of cardiovascular and pulmonary diseases; thus, detection and quantification of these particles are important for evaluating their potential health hazards. As part of the UFP exposure assessments of highwaymaintenance workers in western Switzerland, we compared a miniDiSC with a portable condensation particle counter (P-TRAK). In addition, we performed stationary measurements with a miniDiSC and a scanning mobility particle sizer (SMPS) at a site immediately adjacent to a highway. Measurements with miniDiSC and P-TRAK correlated well (correlation of r = 0.84) but average particle numbers of the miniDiSC were 30%âeuro"60% higher. This difference was significantly increased for mean particle diameters below 40 nm. The correlation between theminiDiSC and the SMPSduring stationary measurements was very high (r = 0.98) although particle numbers from the miniDiSC were 30% lower. Differences between the three devices were attributed to the different cutoff diameters for detection. Correction for this size dependent effect led to very similar results across all counters.We did not observe any significant influence of other particle characteristics. Our results suggest that the miniDiSC provides accurate particle number concentrations and geometric mean diameters at traffic-influenced sites, making it a useful tool for personal exposure assessment in such settings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traditional culture-dependent methods to quantify and identify airborne microorganisms are limited by factors such as short-duration sampling times and inability to count nonculturableor non-viable bacteria. Consequently, the quantitative assessment of bioaerosols is often underestimated. Use of the real-time quantitative polymerase chain reaction (Q-PCR) to quantify bacteria in environmental samples presents an alternative method, which should overcome this problem. The aim of this study was to evaluate the performance of a real-time Q-PCR assay as a simple and reliable way to quantify the airborne bacterial load within poultry houses and sewage treatment plants, in comparison with epifluorescencemicroscopy and culture-dependent methods. The estimates of bacterial load that we obtained from real-time PCR and epifluorescence methods, are comparable, however, our analysis of sewage treatment plants indicate these methods give values 270-290 fold greater than those obtained by the ''impaction on nutrient agar'' method. The culture-dependent method of air impaction on nutrient agar was also inadequate in poultry houses, as was the impinger-culture method, which gave a bacterial load estimate 32-fold lower than obtained by Q-PCR. Real-time quantitative PCR thus proves to be a reliable, discerning, and simple method that could be used to estimate airborne bacterial load in a broad variety of other environments expected to carry high numbers of airborne bacteria. [Authors]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inhalation of fungal particles is a ubiquitous way of exposure to microorganisms during human life; however, this exposure may promote or exacerbate respiratory diseases only in particular exposure conditions and human genetic background. Depending on the fungal species and form, fungal particles can induce symptoms in the lung by acting as irritants, aeroallergens or pathogens causing infection. Some thermophilic species can even act in all these three ways (e.g. Aspergillus, Penicillium), mesophilic species being only involved in allergic and/or non-allergic airway diseases (e.g. Cladosporium, Alternaria, Fusarium). The goal of the present review is to present the current knowledge on the interaction between airborne fungal particles and the host immune system, to illustrate the differences of immune sensing of different fungal species and to emphasise the importance of conducting research on non-conventional mesophilic fungal species. Indeed, the diversity of fungal species we inhale and the complexity of their composition have a direct impact on fungal particle recognition and immune system decision to tolerate or respond to those particles, eventually leading to collateral damages promoting airway pathologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Occupational exposure to bioaerosols in wastewater treatment plants (WWTP) and its consequence on workers׳ health are well documented. Most studies were devoted to enumerating and identifying cultivable bacteria and fungi, as well as measuring concentrations of airborne endotoxins, as these are the main health-related factors found in WWTP. Surprisingly, very few studies have investigated the presence and concentrations of airborne virus in WWTP. However, many enteric viruses are present in wastewater and, due to their small size, they should become aerosolized. Two in particular, the norovirus and the adenovirus, are extremely widespread and are the major causes of infectious gastrointestinal diseases reported around the world. The third one, hepatitis E virus, has an emerging status. GOAL AND METHODS: This study׳s objectives were to detect and quantify the presence and concentrations of 3 different viruses (adenovirus, norovirus and the hepatitis E virus) in air samples from 31 WWTPs by using quantitative polymerase chain reaction (qPCR) during two different seasons and two consecutive years. RESULTS: Adenovirus was present in 100% of summer WWTP samples and 97% of winter samples. The highest airborne concentration measured was 2.27×10(6) genome equivalent/m(3) and, on average, these were higher in summer than in winter. Norovirus was detected in only 3 of the 123 air samples, and the hepatitis E virus was not detected. CONCLUSIONS: Concentrations of potentially pathogenic viral particles in WWTP air are non-negligible and could partly explain the work-related gastrointestinal symptoms often reported in employees in this sector.