10 resultados para 6K-956-CR
em Université de Lausanne, Switzerland
Resumo:
PURPOSE: The purposes of this study were to (1) develop a high-resolution 3-T magnetic resonance angiography (MRA) technique with an in-plane resolution approximate to that of multidetector coronary computed tomography (MDCT) and a voxel size of 0.35 × 0.35 × 1.5 mm³ and to (2) investigate the image quality of this technique in healthy participants and preliminarily in patients with known coronary artery disease (CAD). MATERIALS AND METHODS: A 3-T coronary MRA technique optimized for an image acquisition voxel as small as 0.35 × 0.35 × 1.5 mm³ (high-resolution coronary MRA [HRC]) was implemented and the coronary arteries of 22 participants were imaged. These included 11 healthy participants (average age, 28.5 years; 5 men) and 11 participants with CAD (average age, 52.9 years; 5 women) as identified on MDCT. In addition, the 11 healthy participants were imaged using a method with a more common spatial resolution of 0.7 × 1 × 3 mm³ (regular-resolution coronary MRA [RRC]). Qualitative and quantitative comparisons were made between the 2 MRA techniques. RESULTS: Normal vessels and CAD lesions were successfully depicted at 350 × 350 μm² in-plane resolution with adequate signal-to-noise ratio (SNR) and contrast-to-noise ratio. The CAD findings were consistent among MDCT and HRC. The HRC showed a 47% improvement in sharpness despite a reduction in SNR (by 72%) and in contrast-to-noise ratio (by 86%) compared with the regular-resolution coronary MRA. CONCLUSION: This study, as a first step toward substantial improvement in the resolution of coronary MRA, demonstrates the feasibility of obtaining at 3 T a spatial resolution that approximates that of MDCT. The acquisition in-plane pixel dimensions are as small as 350 × 350 μm² with a 1.5-mm slice thickness. Although SNR is lower, the images have improved sharpness, resulting in image quality that allows qualitative identification of disease sites on MRA consistent with MDCT.
Resumo:
Purpose: To study the filtering site using ultrasound biomicroscopy. (UBM) after posterior deep sclerectomy with Ex-PRESS? X-50 implant in patients undergoing filtering surgery.¦Methods: Twenty-six patients that participated in this prospective, non comparative study underwent a posterior deep sclerectomy and an Ex- PRESS? X-50 tube implantation. Clinical outcome factors recorded include: intraocular pressure, number of antiglaucoma medications, best corrected visual acuity (BCVA), frequency and types of complications. Six months postoperatively, an ultrasound biomicroscopy examination was performed.¦Results: Mean follow up was 12.0±3.4 months. Mean IOP decreased from 21 ±5.7 mmHg to 12.4±3 mmHg. At last follow-up examination, 65% of eyes had a complete success and 30% a qualified success. The mean number of antiglaucoma medications decreased from 2.5±1.2 preoperatively to 0.7±1 at the last follow-up postoperatively. BCVA was not changed. 27 complications were observed. On the UBM images, the mean intrascleral space volume was 0.25±0.27 mm3 and no relationship was found between volume and intraocular pressure reduction. We noted in 5/26 (19%) eyes a suprachoroïdal hypoechoic. Low-reflective blebs (L-type) were the most common: 15/26 (58%). No correlation between UBM findings and surgical success was evident.¦Conclusions: Deep sclerectomy with Ex-PRESS? X-50 tube implantation seems an efficient glaucoma surgery. It allows satisfactory IOP reduction with a low number of post operative complications. The advantages of deep sclerectomy with collagen implant are maintained with this modified technique. In both, the same reflective types of filtering blebs are present (high, low, encapsulated and flat). The UBM underlines the three mechanisms of aqueous humor resorption previously identified but no correlation with surgical success can be proved.¦-¦Ce travail de thèse est une analyse par ultrasonographic biomicroscopique (UBM) du site de filtration après sclérectomie profonde postérieure modifiée avec implantation d'un tube Ex- PRESS? X-50.¦Vingt six patients atteints d'un glaucome à angle ouvert, ont participé à cette étude prospective et non-comparative. Le critère d'inclusion est un glaucome à angle ouvert non contrôlé malgré un traitement topique maximal.¦Différents types de chirurgie filtrante sont effectués dans la chirurgie du glaucome dont la trabéculectomie et la sclérectomie profonde.¦L'intervention chirurgicale pratiquée dans cette étude consiste en l'implantation d'un tube Ex-PRESS? X-50 de format défini (3 mm de longueur et 50 μπι de diamètre interne) dans la chambre antérieure,au niveau du trabeculum, sous un volet scléral, ce qui permet le drainage de l'humeur aqueuse vers les espaces sous-conjonctivaux, avec diminution de la pression intraoculaire.¦Cette technique implique uniquement une dissection d'un volet scléral superficiel , sans volet scléral profond comme d'une sclérectomie profonde classique.¦Les modes de fonctionnement de cette sclérectomie profonde modifiée sont explorés par UBM, qui donne des images à haute résolution, semblables à des coupes anatomiques. Le volume de l'espace intrascléral créé artificiellement peut en effet être mesuré et mis en corrélation avec la pression intraoculaire et donc avec le taux de succès. Les différents types d'échogénécité de la bulle de filtration sous-conjonctivale provoquée par la dérivation de l'humeur aqueuse sont également observés. La présence éventuelle d'une filtration supplémentaire au niveau choroïdien est aussi détectée.¦De février 2007 à juin 2008, nous avons suivi chez les vingt six yeux des vingt six patients le volume intrascléral, la filtration sous-conjonctivale et la filtration choroïdienne le cas échéant, de même que l'acuité visuelle, la pression intraoculaire, le nombre de traitement antihypertenseur topique et les complications.¦Les résultats démontrent une réduction de 41 % par rapport à la pression intraoculaire préopératoire, ce qui est statistiquement significatif (p<0.0005). En ce qui concerne l'acuité visuelle, les valeurs demeurent stables. Par ailleurs, le nombre de médicaments antiglaucomateux diminue de façon significative de 2.5 ± 1.2 en préopératoire à 0.7 ± 1.0 au dernier examen (p<0.0005). Le volume de l'espace intrascléral, apparaissant toujours en échographie d'aspect fusiforme, n'est pas corrélé de façon significative avec un meilleur succès chirurgical bien que l'on aperçoive une tendance à une corrélation entre un plus grand volume et une pression intraoculaire plus basse.¦La classification la bulle de filtration se fait selon les 4 catégories de bulle de filtration décrites dans la littérature. La répartition révèle une majorité de type L soit hypoéchogène: 15/26 (58%) et une proportion identique, soit, 4/26 (16%), de bulles hyperéchogènes (type H) et encapsulées (type E); les bulles de filtration plates et hyperéchogènes (type F) sont les moins nombreuses 3/26 (11 %).¦La ligne hyporéflective visible dans 19 % des cas entre la sclère et la choroïde représentant potentiellement un drainage suprachoroïdien, n'est pas associée statistiquement à une meilleure filtration et une pression intraoculaire plus basse mais demeure une troisième voie de filtration, en plus de la filtration sous-conjonctivale et intrasclérale.¦En conclusion, cette technique différente, offrant une plus grande sécurité et des résultats satisfaisants sur l'abaissement de la pression intraoculaire, peut être, dans certains cas, une alternative à la sclérectomie profonde classique ,dont elle partage les mécanismes de filtration objectivés par ultrasonographic biomicrioscopique.
Resumo:
An objective analysis of image quality parameters was performed for a computed radiography (CR) system using both standard single-side and prototype dual-side read plates. The pre-sampled modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) for the systems were determined at three different beam qualities representative of pediatric chest radiography, at an entrance detector air kerma of 5 microGy. The NPS and DQE measurements were realized under clinically relevant x-ray spectra for pediatric radiology, including x-ray scatter radiations. Compared to the standard single-side read system, the MTF for the dual-side read system is reduced, but this is offset by a significant decrease in image noise, resulting in a marked increase in DQE (+40%) in the low spatial frequency range. Thus, for the same image quality, the new technology permits the CR system to be used at a reduced dose level.
Resumo:
In our recent paper by Monnin et al. [Med. Phys. 33, 411-420 (2006)], an objective analysis of the relative performance of a computed radiography (CR) system using both standard single-side (ST-VI) and prototype dual-side read (ST-BD) plates was reported. The presampled modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) for the systems were determined at three different beam qualities representative of paediatric chest radiography, at an entrance detector air kerma of 5 microGy. Experiments demonstrated that, compared to the standard single-side read system, the MTF for the dual-side read system was slightly reduced, but a significant decrease in image noise resulted in a marked increase in DQE (+40%) in the low spatial frequency range. However, the DQE improvement for the ST-BD plate decreased with increasing spatial frequency, and, at spatial frequencies above 2.2 mm(-1), the DQE of the dual-side read system was lower than that of the single-side one.
Resumo:
Objectifs: Comparaison des performances en qualité d'image des deux types de systèmes CR. Matériels et méthodes: Les performances ont été mesurées au moyen de la fonction de transfert de modulation (FTM), du spectre de bruit, de l'efficacité quantique de détection (DQE),le seuil de détection du contraste en épaisseur d'or et la dose glandulaire moyenne. Les systèmes CR à aiguilles Agfa HM5.0 et Carestream SNP-M1 ont étécomparés aux systèmes à poudre Agfa MM3.0, Fuji ProfectCS et Carestream EHR-M3. Résultats: La FTM à 5mm-1 de Agfa HM5,0 et Carestream SNP-M1 est 0,21 et 0,27, et entre 0,14 et 0,16 pour les systèmes à poudre. Un DQE maximal de 0,51 et 0,5 a étéobtenu pour Agfa HM5,0 et Carestream SNP-M1, et 0,35, 0,50 et 0,34 pour Agfa MM3,0, Fuji Profect et Carestream EHR-M3. Des valeurs de DQE à 5mm-1 de0,18 et 0,13 ont été obtenues pour Agfa HM5,0 et Carestream SNP-M1, et entre 0,04 et 0,065 pour les systèmes à poudre. Les seuils de détection du contrastede Agfa HM5,0 et Carestream SNP-M1 étaient 1,33im et 1,29im, et 1,45im et 1,63im pour Agfa MM3,0 et Fuji Profect. Conclusion: Les systèmes à aiguilles offrent des meilleures FTM et DQE et un seuil de visibilité du contraste plus bas que les systèmes à poudre .
Resumo:
Three standard radiation qualities (RQA 3, RQA 5 and RQA 9) and two screens, Kodak Lanex Regular and Insight Skeletal, were used to compare the imaging performance and dose requirements of the new Kodak Hyper Speed G and the current Kodak T-MAT G/RA medical x-ray films. The noise equivalent quanta (NEQ) and detective quantum efficiencies (DQE) of the four screen-film combinations were measured at three gross optical densities and compared with the characteristics for the Kodak CR 9000 system with GP (general purpose) and HR (high resolution) phosphor plates. The new Hyper Speed G film has double the intrinsic sensitivity of the T-MAT G/RA film and a higher contrast in the high optical density range for comparable exposure latitude. By providing both high sensitivity and high spatial resolution, the new film significantly improves the compromise between dose and image quality. As expected, the new film has a higher noise level and a lower signal-to-noise ratio than the standard film, although in the high frequency range this is compensated for by a better resolution, giving better DQE results--especially at high optical density. Both screen-film systems outperform the phosphor plates in terms of MTF and DQE for standard imaging conditions (Regular screen at RQA 5 and RQA 9 beam qualities). At low energy (RQA 3), the CR system has a comparable low-frequency DQE to screen-film systems when used with a fine screen at low and middle optical densities, and a superior low-frequency DQE at high optical density.
Resumo:
This study investigated fingermark residues using Fourier transform infrared microscopy (μ- FTIR) in order to obtain fundamental information about the marks' initial composition and aging kinetics. This knowledge would be an asset for fundamental research on fingermarks, such as for dating purposes. Attenuated Total Reflection (ATR) and single-point reflection modes were tested on fresh fingermarks. ATR proved to be better suited and this mode was subsequently selected for further aging studies. Eccrine and sebaceous material was found in fresh and aged fingermarks and the spectral regions 1000-1850 cm-1 and 2700-3600 cm-1 were identified as the most informative. The impact of substrates (aluminium and glass slides) and storage conditions (storage in the light and in the dark) on fingermark aging was also studied. Chemometric analyses showed that fingermarks could be grouped according to their age regardless of the substrate when they were stored in an open box kept in an air-conditioned laboratory at around 20°C next to a window. On the contrary, when fingermarks were stored in the dark, only specimens deposited on the same substrate could be grouped by age. Thus, the substrate appeared to influence aging of fingermarks in the dark. Furthermore, PLS regression analyses were conducted in order to study the possibility of modelling fingermark aging for potential fingermark dating applications. The resulting models showed an overall precision of ±3 days and clearly demonstrated their capability to differentiate older fingermarks (20 and 34-days old) from newer ones (1, 3, 7 and 9-days old) regardless of the substrate and lighting conditions. These results are promising from a fingermark dating perspective. Further research is required to fully validate such models and assess their robustness and limitations in uncontrolled casework conditions.