12 resultados para 6K-955-CR

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess whether lambda waves are elicited by watching television (TV) and their association with demographical and EEG features. METHODS: We retrospectively compared lambda wave occurrence in prolonged EEG monitorings of outpatients who were allowed to watch TV and in standard EEGs recorded in TV-free rooms. All EEGs were interpreted by the same two electroencephalographers. RESULTS: Of 2,072 standard EEG reports, 36 (1.7 %) mentioned lambda waves versus 46 (32.2%) of 143 prolonged EEG monitoring reports (P < 0.001). Multivariable comparison of prolonged EEG monitorings and standard EEGs disclosed that recordings performed in rooms with a TV (odds ratio, 20.6; 95% confidence interval, 4.8-88.0) and normal EEGs (odds ratio, 3.03; 95% confidence interval, 1.5-6.25) were independently associated with lambda waves. In the prolonged EEG monitoring group, all recordings with lambda waves also had positive occipital sharp transients of sleep. CONCLUSIONS: Watching TV likely represents a powerful and previously unrecognized stimulus for lambda waves. Furthermore, this study confirms the benign nature of this EEG variant and its strong association with positive occipital sharp transients of sleep.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An objective analysis of image quality parameters was performed for a computed radiography (CR) system using both standard single-side and prototype dual-side read plates. The pre-sampled modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) for the systems were determined at three different beam qualities representative of pediatric chest radiography, at an entrance detector air kerma of 5 microGy. The NPS and DQE measurements were realized under clinically relevant x-ray spectra for pediatric radiology, including x-ray scatter radiations. Compared to the standard single-side read system, the MTF for the dual-side read system is reduced, but this is offset by a significant decrease in image noise, resulting in a marked increase in DQE (+40%) in the low spatial frequency range. Thus, for the same image quality, the new technology permits the CR system to be used at a reduced dose level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IL-28 (IFN-λ) cytokines exhibit potent antiviral and antitumor function but their full spectrum of activities remains largely unknown. Recently, IL-28 cytokine family members were found to be profoundly down-regulated in allergic asthma. We now reveal a novel role of IL-28 cytokines in inducing type 1 immunity and protection from allergic airway disease. Treatment of wild-type mice with recombinant or adenovirally expressed IL-28A ameliorated allergic airway disease, suppressed Th2 and Th17 responses and induced IFN-γ. Moreover, abrogation of endogenous IL-28 cytokine function in IL-28Rα(-/-) mice exacerbated allergic airway inflammation by augmenting Th2 and Th17 responses, and IgE levels. Central to IL-28A immunoregulatory activity was its capacity to modulate lung CD11c(+) dendritic cell (DC) function to down-regulate OX40L, up-regulate IL-12p70 and promote Th1 differentiation. Consistently, IL-28A-mediated protection was absent in IFN-γ(-/-) mice or after IL-12 neutralization and could be adoptively transferred by IL-28A-treated CD11c(+) cells. These data demonstrate a critical role of IL-28 cytokines in controlling T cell responses in vivo through the modulation of lung CD11c(+) DC function in experimental allergic asthma. →See accompanying Closeup by Michael R Edwards and Sebastian L Johnston http://dx.doi.org/10.1002/emmm.201100143.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hepatitis C virus (HCV) infections are the major cause of chronic liver disease, cirrhosis and hepatocellular carcinoma worldwide. Both spontaneous and treatment-induced clearance of HCV depend on genetic variation within the interferon-lambda locus, but until now no clear causal relationship has been established. Here we demonstrate that an amino-acid substitution in the IFNλ4 protein changing a proline at position 70 to a serine (P70S) substantially alters its antiviral activity. Patients harbouring the impaired IFNλ4-S70 variant display lower interferon-stimulated gene (ISG) expression levels, better treatment response rates and better spontaneous clearance rates, compared with patients coding for the fully active IFNλ4-P70 variant. Altogether, these data provide evidence supporting a role for the active IFNλ4 protein as the driver of high hepatic ISG expression as well as the cause of poor HCV clearance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In our recent paper by Monnin et al. [Med. Phys. 33, 411-420 (2006)], an objective analysis of the relative performance of a computed radiography (CR) system using both standard single-side (ST-VI) and prototype dual-side read (ST-BD) plates was reported. The presampled modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) for the systems were determined at three different beam qualities representative of paediatric chest radiography, at an entrance detector air kerma of 5 microGy. Experiments demonstrated that, compared to the standard single-side read system, the MTF for the dual-side read system was slightly reduced, but a significant decrease in image noise resulted in a marked increase in DQE (+40%) in the low spatial frequency range. However, the DQE improvement for the ST-BD plate decreased with increasing spatial frequency, and, at spatial frequencies above 2.2 mm(-1), the DQE of the dual-side read system was lower than that of the single-side one.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectifs: Comparaison des performances en qualité d'image des deux types de systèmes CR. Matériels et méthodes: Les performances ont été mesurées au moyen de la fonction de transfert de modulation (FTM), du spectre de bruit, de l'efficacité quantique de détection (DQE),le seuil de détection du contraste en épaisseur d'or et la dose glandulaire moyenne. Les systèmes CR à aiguilles Agfa HM5.0 et Carestream SNP-M1 ont étécomparés aux systèmes à poudre Agfa MM3.0, Fuji ProfectCS et Carestream EHR-M3. Résultats: La FTM à 5mm-1 de Agfa HM5,0 et Carestream SNP-M1 est 0,21 et 0,27, et entre 0,14 et 0,16 pour les systèmes à poudre. Un DQE maximal de 0,51 et 0,5 a étéobtenu pour Agfa HM5,0 et Carestream SNP-M1, et 0,35, 0,50 et 0,34 pour Agfa MM3,0, Fuji Profect et Carestream EHR-M3. Des valeurs de DQE à 5mm-1 de0,18 et 0,13 ont été obtenues pour Agfa HM5,0 et Carestream SNP-M1, et entre 0,04 et 0,065 pour les systèmes à poudre. Les seuils de détection du contrastede Agfa HM5,0 et Carestream SNP-M1 étaient 1,33im et 1,29im, et 1,45im et 1,63im pour Agfa MM3,0 et Fuji Profect. Conclusion: Les systèmes à aiguilles offrent des meilleures FTM et DQE et un seuil de visibilité du contraste plus bas que les systèmes à poudre .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three standard radiation qualities (RQA 3, RQA 5 and RQA 9) and two screens, Kodak Lanex Regular and Insight Skeletal, were used to compare the imaging performance and dose requirements of the new Kodak Hyper Speed G and the current Kodak T-MAT G/RA medical x-ray films. The noise equivalent quanta (NEQ) and detective quantum efficiencies (DQE) of the four screen-film combinations were measured at three gross optical densities and compared with the characteristics for the Kodak CR 9000 system with GP (general purpose) and HR (high resolution) phosphor plates. The new Hyper Speed G film has double the intrinsic sensitivity of the T-MAT G/RA film and a higher contrast in the high optical density range for comparable exposure latitude. By providing both high sensitivity and high spatial resolution, the new film significantly improves the compromise between dose and image quality. As expected, the new film has a higher noise level and a lower signal-to-noise ratio than the standard film, although in the high frequency range this is compensated for by a better resolution, giving better DQE results--especially at high optical density. Both screen-film systems outperform the phosphor plates in terms of MTF and DQE for standard imaging conditions (Regular screen at RQA 5 and RQA 9 beam qualities). At low energy (RQA 3), the CR system has a comparable low-frequency DQE to screen-film systems when used with a fine screen at low and middle optical densities, and a superior low-frequency DQE at high optical density.