14 resultados para 240402 Quantum Optics and Lasers
em Université de Lausanne, Switzerland
Resumo:
Quantum indeterminism is frequently invoked as a solution to the problem of how a disembodied soul might interact with the brain (as Descartes proposed), and is sometimes invoked in theories of libertarian free will even when they do not involve dualistic assumptions. Taking as example the Eccles-Beck model of interaction between self (or soul) and brain at the level of synaptic exocytosis, I here evaluate the plausibility of these approaches. I conclude that Heisenbergian uncertainty is too small to affect synaptic function, and that amplification by chaos or by other means does not provide a solution to this problem. Furthermore, even if Heisenbergian effects did modify brain functioning, the changes would be swamped by those due to thermal noise. Cells and neural circuits have powerful noise-resistance mechanisms, that are adequate protection against thermal noise and must therefore be more than sufficient to buffer against Heisenbergian effects. Other forms of quantum indeterminism must be considered, because these can be much greater than Heisenbergian uncertainty, but these have not so far been shown to play a role in the brain.
Resumo:
Digital holographic microscopy (DHM) allows optical-path-difference (OPD) measurements with nanometric accuracy. OPD induced by transparent cells depends on both the refractive index (RI) of cells and their morphology. This Letter presents a dual-wavelength DHM that allows us to separately measure both the RI and the cellular thickness by exploiting an enhanced dispersion of the perfusion medium achieved by the utilization of an extracellular dye. The two wavelengths are chosen in the vicinity of the absorption peak of the dye, where the absorption is accompanied by a significant variation of the RI as a function of the wavelength.
Resumo:
Digital holographic microscopy (DHM) is a technique that allows obtaining, from a single recorded hologram, quantitative phase image of living cell with interferometric accuracy. Specifically the optical phase shift induced by the specimen on the transmitted wave front can be regarded as a powerful endogenous contrast agent, depending on both the thickness and the refractive index of the sample. Thanks to a decoupling procedure cell thickness and intracellular refractive index can be measured separately. Consequently, Mean corpuscular volume (MCV) and mean corpuscular hemoglobin concentration (MCHC), two highly relevant clinical parameters, have been measured non-invasively at a single cell level. The DHM nanometric axial and microsecond temporal sensitivities have permitted to measure the red blood cell membrane fluctuations (CMF) on the whole cell surface. ©2009 COPYRIGHT SPIE--The International Society for Optical Engineering.
Resumo:
Digital holography microscopy (DHM) is an optical microscopy technique which allows recording non-invasively the phase shift induced by living cells with nanometric sensitivity. Here, we exploit the phase signal as an indicator of dry mass (related to the protein concentration). This parameter allows monitoring the protein production rate and its evolution during the cell cycle. ©2008 COPYRIGHT SPIE
Resumo:
The kinetics of binding of a glycolipid-anchored protein (the promastigote surface protease, PSP) to planar lecithin bilayers is studied by an integrated optics technique, in which the bilayer membrane is supported on an optical wave guide and the phase velocities of guided light modes in the wave guide are measured. From these velocities, the optical parameters of the membrane and PSP layers deposited on the waveguide are determined, yielding in particular the mass of PSP bound to the membrane, which is followed in real time. From a comparison of the binding rates of PSP and PSP from which the lipid moiety has been removed, it is shown that the lipid moiety plays a key role in anchoring the protein to the membrane. Specific and nonspecific binding of antibodies to membrane-anchored PSP is also investigated. As little as a fifth of a monolayer of PSP is sufficient to suppress the appreciable nonspecific binding of antibodies to the membrane.
Resumo:
NlmCategory="UNASSIGNED">A version of cascaded systems analysis was developed specifically with the aim of studying quantum noise propagation in x-ray detectors. Signal and quantum noise propagation was then modelled in four types of x-ray detectors used for digital mammography: four flat panel systems, one computed radiography and one slot-scan silicon wafer based photon counting device. As required inputs to the model, the two dimensional (2D) modulation transfer function (MTF), noise power spectra (NPS) and detective quantum efficiency (DQE) were measured for six mammography systems that utilized these different detectors. A new method to reconstruct anisotropic 2D presampling MTF matrices from 1D radial MTFs measured along different angular directions across the detector is described; an image of a sharp, circular disc was used for this purpose. The effective pixel fill factor for the FP systems was determined from the axial 1D presampling MTFs measured with a square sharp edge along the two orthogonal directions of the pixel lattice. Expectation MTFs were then calculated by averaging the radial MTFs over all possible phases and the 2D EMTF formed with the same reconstruction technique used for the 2D presampling MTF. The quantum NPS was then established by noise decomposition from homogenous images acquired as a function of detector air kerma. This was further decomposed into the correlated and uncorrelated quantum components by fitting the radially averaged quantum NPS with the radially averaged EMTF(2). This whole procedure allowed a detailed analysis of the influence of aliasing, signal and noise decorrelation, x-ray capture efficiency and global secondary gain on NPS and detector DQE. The influence of noise statistics, pixel fill factor and additional electronic and fixed pattern noises on the DQE was also studied. The 2D cascaded model and decompositions performed on the acquired images also enlightened the observed quantum NPS and DQE anisotropy.
Resumo:
Different interferometric techniques were developed last decade to obtain full field, quantitative, and absolute phase imaging, such as phase-shifting, Fourier phase microscopy, Hilbert phase microscopy or digital holographic microscopy (DHM). Although, these techniques are very similar, DHM combines several advantages. In contrast, to phase shifting, DHM is indeed capable of single-shot hologram recording allowing a real-time absolute phase imaging. On the other hand, unlike to Fourier phase or Hilbert phase microscopy, DHM does not require to record in focus images of the specimen on the digital detector (CCD or CMOS camera), because a numerical focalization adjustment can be performed by a numerical wavefront propagation. Consequently, the depth of view of high NA microscope objectives is numerically extended. For example, two different biological cells, floating at different depths in a liquid, can be focalized numerically from the same digital hologram. Moreover, the numerical propagation associated to digital optics and automatic fitting procedures, permits vibrations insensitive full- field phase imaging and the complete compensation for a priori any image distortion or/and phase aberrations introduced for example by imperfections of holders or perfusion chamber. Examples of real-time full-field phase images of biological cells have been demonstrated. ©2008 COPYRIGHT SPIE
Resumo:
We report on advanced dual-wavelength digital holographic microscopy (DHM) methods, enabling single-acquisition real-time micron-range measurements while maintaining single-wavelength interferometric resolution in the nanometer regime. In top of the unique real-time capability of our technique, it is shown that axial resolution can be further increased compared to single-wavelength operation thanks to the uncorrelated nature of both recorded wavefronts. It is experimentally demonstrated that DHM topographic investigation within 3 decades measurement range can be achieved with our arrangement, opening new applications possibilities for this interferometric technique. ©2008 COPYRIGHT SPIE
Resumo:
We present dual-wavelength Digital Holographic Microscopy (DHM) measurements on a certified 8.9 nm high Chromium thin step sample and demonstrate sub-nanometer axial accuracy. We introduce a modified DHM Reference Calibrated Hologram (RCH) reconstruction algorithm taking into account amplitude contributions. By combining this with a temporal averaging procedure and a specific dual-wavelength DHM arrangement, it is shown that specimen topography can be measured with an accuracy, defined as the axial standard deviation, reduced to at least 0.9 nm. Indeed, it is reported that averaging each of the two wavefronts recorded with real-time dual-wavelength DHM can provide up to 30% spatial noise reduction for the given configuration, thanks to their non-correlated nature. ©2008 COPYRIGHT SPIE
Resumo:
Given the adverse impact of image noise on the perception of important clinical details in digital mammography, routine quality control measurements should include an evaluation of noise. The European Guidelines, for example, employ a second-order polynomial fit of pixel variance as a function of detector air kerma (DAK) to decompose noise into quantum, electronic and fixed pattern (FP) components and assess the DAK range where quantum noise dominates. This work examines the robustness of the polynomial method against an explicit noise decomposition method. The two methods were applied to variance and noise power spectrum (NPS) data from six digital mammography units. Twenty homogeneously exposed images were acquired with PMMA blocks for target DAKs ranging from 6.25 to 1600 µGy. Both methods were explored for the effects of data weighting and squared fit coefficients during the curve fitting, the influence of the additional filter material (2 mm Al versus 40 mm PMMA) and noise de-trending. Finally, spatial stationarity of noise was assessed.Data weighting improved noise model fitting over large DAK ranges, especially at low detector exposures. The polynomial and explicit decompositions generally agreed for quantum and electronic noise but FP noise fraction was consistently underestimated by the polynomial method. Noise decomposition as a function of position in the image showed limited noise stationarity, especially for FP noise; thus the position of the region of interest (ROI) used for noise decomposition may influence fractional noise composition. The ROI area and position used in the Guidelines offer an acceptable estimation of noise components. While there are limitations to the polynomial model, when used with care and with appropriate data weighting, the method offers a simple and robust means of examining the detector noise components as a function of detector exposure.
Resumo:
Après avoir situé le contexte de la recherche et défini les enjeux principaux du travail, différents types de nanoparticules, ainsi que leurs principales caractéristiques, sont parcourues. L'élaboration de critères de sélection ayant permis de déterminer les types de nanoparticules potentiellement adaptés à !a détection de traces papillaires, l'étude s'est alors focalisée sur deux familles de composés: les quantum dots et les nanoparticules d'oxyde de silicium. Deux types de quantum dots ont été synthétisés : le tellurure de cadmium et le sulfure de zinc). Ils n'ont toutefois pas permis la détection de traces papillaires réalistes. En effet, seules des traces fraîches et enrichies en sécrétions ont pu être mises en évidence. Toutefois, des résultats ont été obtenus avec les deux types de quantum dots pour la détection de traces papillaires sanglantes. Après optimisation, les techniques rivalisent avec les méthodes couramment appliquées en routine. Cependant, l'interaction se produisant entre les traces et les nanoparticules n'a pas pu être déterminé. Les nanoparticules d'oxyde de silicium ont dès lors été appliquées dans le but de comprendre plus en détails les interactions avec les traces papillaires. Ces nanoparticules ont l'avantage d'offrir un très bon contrôle de surface, permettant ainsi une étude détaillée des phénomènes en jeu. Des propriétés de surface variables ont dès lors été obtenues en greffant diverses molécules à la surface des nanoparticules d'oxyde de silicium. Après avoir exploré différentes hypothèses d'interaction, il a pu être déterminé qu'une réaction chimique se produit lors qu'un groupement de type carboxyle est présent à la surface des particules. Ce groupement réagit avec les fonctions amines primaires des sécrétions. L'interaction chimique a ensuite pu être renforcée par l'utilisation d'un catalyseur, permettant d'accélérer la réaction. Dans la dernière partie du travail, les nanoparticules d'oxyde de silicium ont été comparées à une technique utilisée en routine, la fumigation de cyanoacrylate. Bien que des études plus approfondies soient nécessaires, il s'avère que l'application de nanoparticules d'oxyde de silicium permet une détection de très bonne qualité, moins dépendante du donneur que les techniques courantes. Ces résultats sont prometteurs en vue du développement d'une technique possédant une sensibilité et une sélectivité accrue. - Having situated the background of research and identified key issues of work, different types of nanoparticles and their main features are reviewed. The development of selection criteria lead to the identification of nanoparticles types potentially suitable for fingermarks detection. The study focused then On two families of compounds: quantum dots and silicon oxide nanoparticles. Two types of quantum dots were synthesized and characterised: cadmium telluride and zinc sulphide. Unfortunally, they did not allow the detection realistic fingermarks. Indeed, only fresh and groomed fingermarks have been detected. However, results have been obtained with both types of quantum dots for the detection of fingermarks in blood. After optimization procedures, the quantum dots based teshniques compete with the methods currently used in routine. However, the interaction occurring between fingermarks and nanoparticles could not be determined. Silicon oxide nanoparticles have therefore been applied in order to understand in detail the interactions With fingermarks. These nanoparticles have the advantage of providing a very good surface control, allowing am in-depth study of the phenomena involved. Versatile surface properties were therefore obtained by grafting various molecules on the surface of silicon oxide nanoparticles. Different hypotheses were investigated and it was determined that a chemical reaction occurred between the surface functionalised nanoparticles and the fingermark residues. The carboxyl groups on the surface of the particles react with primary amines of the secretions. Therefore, this interaction was improved by the use of a catalyst. In the last part of the work, silicon oxide nanoparticles were compared to a routinely used technique: cyanocrylate fuming. Although further studies are still needed, it appears that the application of silicon oxide nanoparticles allows fingermark detection of very good quality, with a lowered donor dependency. These results are promising for the development of techniques with greater sensitivity and selectivity.