181 resultados para 157-956

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The purposes of this study were to (1) develop a high-resolution 3-T magnetic resonance angiography (MRA) technique with an in-plane resolution approximate to that of multidetector coronary computed tomography (MDCT) and a voxel size of 0.35 × 0.35 × 1.5 mm³ and to (2) investigate the image quality of this technique in healthy participants and preliminarily in patients with known coronary artery disease (CAD). MATERIALS AND METHODS: A 3-T coronary MRA technique optimized for an image acquisition voxel as small as 0.35 × 0.35 × 1.5 mm³ (high-resolution coronary MRA [HRC]) was implemented and the coronary arteries of 22 participants were imaged. These included 11 healthy participants (average age, 28.5 years; 5 men) and 11 participants with CAD (average age, 52.9 years; 5 women) as identified on MDCT. In addition, the 11 healthy participants were imaged using a method with a more common spatial resolution of 0.7 × 1 × 3 mm³ (regular-resolution coronary MRA [RRC]). Qualitative and quantitative comparisons were made between the 2 MRA techniques. RESULTS: Normal vessels and CAD lesions were successfully depicted at 350 × 350 μm² in-plane resolution with adequate signal-to-noise ratio (SNR) and contrast-to-noise ratio. The CAD findings were consistent among MDCT and HRC. The HRC showed a 47% improvement in sharpness despite a reduction in SNR (by 72%) and in contrast-to-noise ratio (by 86%) compared with the regular-resolution coronary MRA. CONCLUSION: This study, as a first step toward substantial improvement in the resolution of coronary MRA, demonstrates the feasibility of obtaining at 3 T a spatial resolution that approximates that of MDCT. The acquisition in-plane pixel dimensions are as small as 350 × 350 μm² with a 1.5-mm slice thickness. Although SNR is lower, the images have improved sharpness, resulting in image quality that allows qualitative identification of disease sites on MRA consistent with MDCT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Through a rational design approach, we generated a panel of HLA-A*0201/NY-ESO-1(157-165)-specific T cell receptors (TCR) with increasing affinities of up to 150-fold from the wild-type TCR. Using these TCR variants which extend just beyond the natural affinity range, along with an extreme supraphysiologic one having 1400-fold enhanced affinity, and a low-binding one, we sought to determine the effect of TCR binding properties along with cognate peptide concentration on CD8(+) T cell responsiveness. Major histocompatibility complexes (MHC) expressed on the surface of various antigen presenting cells were peptide-pulsed and used to stimulate human CD8(+) T cells expressing the different TCR via lentiviral transduction. At intermediate peptide concentration we measured maximum cytokine/chemokine secretion, cytotoxicity, and Ca(2+) flux for CD8(+) T cells expressing TCR within a dissociation constant (K(D)) range of ∼1-5 μM. Under these same conditions there was a gradual attenuation in activity for supraphysiologic affinity TCR with K(D) < ∼1 μM, irrespective of CD8 co-engagement and of half-life (t(1/2) = ln 2/k(off)) values. With increased peptide concentration, however, the activity levels of CD8(+) T cells expressing supraphysiologic affinity TCR were gradually restored. Together our data support the productive hit rate model of T cell activation arguing that it is not the absolute number of TCR/pMHC complexes formed at equilibrium, but rather their productive turnover, that controls levels of biological activity. Our findings have important implications for various immunotherapies under development such as adoptive cell transfer of TCR-engineered CD8(+) T cells, as well as for peptide vaccination strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a recent vaccination trial assessing the immunogenicity of an NY-ESO-1 (ESO) recombinant protein administered with Montanide and CpG, we have obtained evidence that this vaccine induces specific cytolytic T lymphocytes (CTL) in half of the patients. Most vaccine-induced CTLs were directed against epitopes located in the central part of the protein, between amino acids 81 and 110. This immunodominant region, however, is distinct from another ESO CTL region, 157-165, that is a frequent target of spontaneous CTL responses in A2+ patients bearing ESO tumors. In this study, we have investigated the CTL responses to ESO 157-165 in A2+ patients vaccinated with the recombinant protein. Our data indicate that after vaccination with the protein, CTL responses to ESO 157-165 are induced in some, but not all, A2+ patients. ESO 157-165-specific CTLs induced by vaccination with the ESO protein were functionally heterogeneous in terms of tumor recognition and often displayed decreased tumor reactivity as compared with ESO 157-165-specific CTLs isolated from patients with spontaneous immune responses to ESO. Remarkably, protein-induced CTLs used T-cell receptors similar to those previously isolated from patients vaccinated with synthetic ESO peptides (Vbeta4.1) and distinct from those used by highly tumor-reactive CTLs isolated from patients with spontaneous immune responses (Vbeta1.1, Vbeta8.1, and Vbeta13.1). Together, these results demonstrate that vaccination with the ESO protein elicits a repertoire of ESO 157-165-specific CTLs bearing T-cell receptors that are structurally distinct from those of CTLs found in spontaneous immune responses to the antigen and that are heterogeneous in terms of tumor reactivity, being often poorly tumor reactive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Case Report: A 19 year old female, originally from Cameroon, residentin Switzerland for 10 years, consults for chronic fatigue, constipationand menorrhagia. Clinical examination reveals pain in the iliac fossa,laboratory tests show an iron deficiency anaemia with a hemoglobinof 74 g/l (N: 117-157) and a ferritin less than 3 μg/l (N: 30-300).Gynecological aetiology is strongly suspected.Findings: The dietary history reveals a high intake of African chalkcalled "Mabel" in Lingala, for which she has a craving with criteria forsubstance dependence according to the Diagnostic and StatisticalManual IV. Eating non-food products is called "PICA" and the eatingof earth "geophagia". It is often assumed by the patient that geophagiaoffers nutritional virtues of the earth, and that the land would act asantitoxic, anti-emetic, immune-stimulant, strengthen the intestinalbarrier and be rich in calcium, iron and many nutrients. But insteadgeophagia causes anemia, iron chelation, heavy metal poisoningand significant constipation or obstruction.Management: The patient, following our advice, stopped ingestingchalk. Parenteral iron substitution of ferric carboxymaltose 1000 mgstopped the craving, and resolved her subjective state of fatigue andher haemoglobin normalized to 140 g/l. The menorrhagia resolved withhormone replacement and the constipation subsequently disappeared.Discussion: Our patient was suffering from iron deficiency resulting ina craving for non-food products in this case the earth. We advisepractitioners to systematically ask the question in patients of Africanand South American origin by using synonyms for the word "Mabel"(African chalk, kaolin, Kalaba, calabash chalk, calabash Stone, Kaolin,hurdle, or clay Nzu). A simple question can sometimes avoid costlyinvestigations. The ferrous replacement intravenously can probably stopthe practice of geophagy faster. Finally, we must remember that thispractice is underestimated and rarely expressed by patients as it isoften felt to be a shameful practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: As imatinib pharmacokinetics are highly variable, plasma levels differ largely between patients under the same dosage. Retrospective studies in chronic myeloid leukemia (CML) patients showed significant correlations between low levels and suboptimal response, and between high levels and poor tolerability. Monitoring of plasma levels is thus increasingly advised, targeting trough concentrations of 1000 μg/L and above. Objectives: Our study was launched to assess the clinical usefulness of systematic imatinib TDM in CML patients. The present preliminary evaluation questions the appropriateness of dosage adjustment following plasma level measurement to reach the recommended trough level, while allowing an interval of 4-24 h after last drug intake for blood sampling. Methods: Initial blood samples from the first 9 patients in the intervention arm were obtained 4-25 h after last dose. Trough levels in 7 patients were predicted to be significantly away from the target (6 <750 μg/L, and 1 >1500 μg/L with poor tolerance), based on a Bayesian approach using a population pharmacokinetic model. Individual dosage adjustments were taken up in 5 patients, who had a control measurement 1-4 weeks after dosage change. Predicted trough levels were confronted to anterior model-based extrapolations. Results: Before dosage adjustment, observed concentrations extrapolated at trough ranged from 359 to 1832 μg/L (median 710; mean 804, CV 53%) in the 9 patients. After dosage adjustment they were expected to target between 720 and 1090 μg/L (median 878; mean 872, CV 13%). Observed levels of the 5 recheck measurements extrapolated at trough actually ranged from 710 to 1069 μg/L (median 1015; mean 950, CV 16%) and had absolute differences of 21 to 241 μg/L to the model-based predictions (median 175; mean 157, CV 52%). Differences between observed and predicted trough levels were larger when intervals between last drug intake and sampling were very short (~4 h). Conclusion: These preliminary results suggest that TDM of imatinib using a Bayesian interpretation is able to bring trough levels closer to 1000 μg/L (with CV decreasing from 53% to 16%). While this may simplify blood collection in daily practice, as samples do not have to be drawn exactly at trough, the largest possible interval to last drug intake yet remains preferable. This encourages the evaluation of the clinical benefit of a routine TDM intervention in CML patients, which the randomized Swiss I-COME study aims to.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated fingermark residues using Fourier transform infrared microscopy (μ- FTIR) in order to obtain fundamental information about the marks' initial composition and aging kinetics. This knowledge would be an asset for fundamental research on fingermarks, such as for dating purposes. Attenuated Total Reflection (ATR) and single-point reflection modes were tested on fresh fingermarks. ATR proved to be better suited and this mode was subsequently selected for further aging studies. Eccrine and sebaceous material was found in fresh and aged fingermarks and the spectral regions 1000-1850 cm-1 and 2700-3600 cm-1 were identified as the most informative. The impact of substrates (aluminium and glass slides) and storage conditions (storage in the light and in the dark) on fingermark aging was also studied. Chemometric analyses showed that fingermarks could be grouped according to their age regardless of the substrate when they were stored in an open box kept in an air-conditioned laboratory at around 20°C next to a window. On the contrary, when fingermarks were stored in the dark, only specimens deposited on the same substrate could be grouped by age. Thus, the substrate appeared to influence aging of fingermarks in the dark. Furthermore, PLS regression analyses were conducted in order to study the possibility of modelling fingermark aging for potential fingermark dating applications. The resulting models showed an overall precision of ±3 days and clearly demonstrated their capability to differentiate older fingermarks (20 and 34-days old) from newer ones (1, 3, 7 and 9-days old) regardless of the substrate and lighting conditions. These results are promising from a fingermark dating perspective. Further research is required to fully validate such models and assess their robustness and limitations in uncontrolled casework conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The purpose of this study was to develop a mathematical model (sine model, SIN) to describe fat oxidation kinetics as a function of the relative exercise intensity [% of maximal oxygen uptake (%VO2max)] during graded exercise and to determine the exercise intensity (Fatmax) that elicits maximal fat oxidation (MFO) and the intensity at which the fat oxidation becomes negligible (Fatmin). This model included three independent variables (dilatation, symmetry, and translation) that incorporated primary expected modulations of the curve because of training level or body composition. METHODS: Thirty-two healthy volunteers (17 women and 15 men) performed a graded exercise test on a cycle ergometer, with 3-min stages and 20-W increments. Substrate oxidation rates were determined using indirect calorimetry. SIN was compared with measured values (MV) and with other methods currently used [i.e., the RER method (MRER) and third polynomial curves (P3)]. RESULTS: There was no significant difference in the fitting accuracy between SIN and P3 (P = 0.157), whereas MRER was less precise than SIN (P < 0.001). Fatmax (44 +/- 10% VO2max) and MFO (0.37 +/- 0.16 g x min(-1)) determined using SIN were significantly correlated with MV, P3, and MRER (P < 0.001). The variable of dilatation was correlated with Fatmax, Fatmin, and MFO (r = 0.79, r = 0.67, and r = 0.60, respectively, P < 0.001). CONCLUSIONS: The SIN model presents the same precision as other methods currently used in the determination of Fatmax and MFO but in addition allows calculation of Fatmin. Moreover, the three independent variables are directly related to the main expected modulations of the fat oxidation curve. SIN, therefore, seems to be an appropriate tool in analyzing fat oxidation kinetics obtained during graded exercise.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Synchronization of data coming from different sources is of high importance in biomechanics to ensure reliable analyses. This synchronization can either be performed through hardware to obtain perfect matching of data, or post-processed digitally. Hardware synchronization can be achieved using trigger cables connecting different devices in many situations; however, this is often impractical, and sometimes impossible in outdoors situations. The aim of this paper is to describe a wireless system for outdoor use, allowing synchronization of different types of - potentially embedded and moving - devices. In this system, each synchronization device is composed of: (i) a GPS receiver (used as time reference), (ii) a radio transmitter, and (iii) a microcontroller. These components are used to provide synchronized trigger signals at the desired frequency to the measurement device connected. The synchronization devices communicate wirelessly, are very lightweight, battery-operated and thus very easy to set up. They are adaptable to every measurement device equipped with either trigger input or recording channel. The accuracy of the system was validated using an oscilloscope. The mean synchronization error was found to be 0.39 μs and pulses are generated with an accuracy of <2 μs. The system provides synchronization accuracy about two orders of magnitude better than commonly used post-processing methods, and does not suffer from any drift in trigger generation.

Relevância:

10.00% 10.00%

Publicador: