129 resultados para spectral sensitivity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Natural killer (NK) cells are cytotoxic lymphocytes that substantially contribute to the therapeutic benefit of antitumor antibodies like Rituximab, a crucial component in the treatment of B-cell malignancies. In chronic lymphocytic leukemia (CLL), the ability of NK cells to lyse the malignant cells and to mediate antibody-dependent cellular cytotoxicity upon Fc receptor stimulation is compromised, but the underlying mechanisms are largely unclear. We report here that NK-cells activation-dependently produce the tumor necrosis factor family member 'B-cell activating factor' (BAFF) in soluble form with no detectable surface expression, also in response to Fc receptor triggering by therapeutic CD20-antibodies. BAFF in turn enhanced the metabolic activity of primary CLL cells and impaired direct and Rituximab-induced lysis of CLL cells without affecting NK reactivity per se. The neutralizing BAFF antibody Belimumab, which is approved for treatment of systemic lupus erythematosus, prevented the effects of BAFF on the metabolism of CLL cells and restored their susceptibility to direct and Rituximab-induced NK-cell killing in allogeneic and autologous experimental systems. Our findings unravel the involvement of BAFF in the resistance of CLL cells to NK-cell antitumor immunity and Rituximab treatment and point to a benefit of combinatory approaches employing BAFF-neutralizing drugs in B-cell malignancies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Our retrospective, international study aimed at evaluating the activity and safety of eribulin mesylate (EM) in pretreated metastatic breast cancer (MBC) in a routine clinical setting. METHODS: Patients treated with EM for a locally advanced or MBC between March 2011 and January 2014 were included in the study. Clinical and biological assessment of toxicity was performed at each visit. Tumour response was assessed every 3 cycles of treatment. A database was created to collect clinical, pathological and treatment data. RESULTS: Two hundred and fifty-eight patients were included in the study. Median age was 59 years old. Tumours were Hormone Receptor (HR)-positive (73.3 %) HER2-positive (10.2 %), and triple negative (TN, 22.5 %). 86.4 % of the patients presented with visceral metastases, mainly in the liver (67.4 %). Median previous metastatic chemotherapies number was 4 [1-9]. Previous treatments included anthracyclines and/or taxanes (100 %) and capecitabine (90.7 %). Median number of EM cycles was 5 [1-19]. The relative dose intensity was 0.917. At the time of analysis (median follow-up of 13.9 months), 42.3 % of the patients were still alive. The objective response rate was 25.2 % (95 %CI: 20-31) with a 36.1 % clinical benefit rate (CBR). Median time to progression (TTP) and overall survival were 3.97 (95 %CI: 3.25-4.3) and 11.2 (95 %CI: 9.3-12.1) months, respectively. One- and 2-year survival rates were 45.5 and 8.5 %, respectively. In multivariate analysis, HER2 positivity (HR = 0.29), the presence of lung metastases (HR = 2.49) and primary taxanes resistance (HR = 2.36) were the only three independent CBR predictive factors, while HR positivity (HR = 0.67), the presence of lung metastases (HR = 1.52) and primary taxanes resistance (HR = 1.50) were the only three TTP independent prognostic factors. Treatment was globally well tolerated. Most common grade 3-4 toxicities were neutropenia (20.9 %), peripheral neuropathy (3.9 %), anaemia (1.6 %), liver dysfunction (0.8 %) and thrombocytopenia (0.4 %). Thirteen patients (5 %) developed febrile neutropenia. CONCLUSION: EM is an effective new option in heavily pretreated MBC, with a favourable efficacy/safety ratio in a clinical practice setting. Our results comfort the use of this new molecule and pledge for the evaluation of EM-trastuzumab combination in this setting. Tumour biology, primary taxanes sensitivity and metastatic sites could represent useful predictive and prognostic factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

(Matrix-assisted) laser desorption/ionization ((MA)LDI) mass spectrometry imaging (MSI) has been driven by remarkable technological developments in the last couple of years. Although molecular information of a wide range of molecules including peptides, lipids, metabolites, and xenobiotics can be mapped, (MA)LDI MSI only leads to the detection of the most abundant soluble molecules in the cells and, consequently, does not provide access to the least expressed species, which can be very informative in the scope of disease research. Within a short period of time, numerous protocols and concepts have been developed and introduced in order to increase MSI sensitivity, including in situ tissue chemistry and solvent-free matrix depositions. In this chapter, we will discuss some of the latest developments in the field of high-sensitivity MSI using solvent-free matrix depositions and will detail protocols of two methods with their capability of enriching molecular MSI signal as demonstrated within our laboratory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A photonic system has been developed that enables sensitive quantitative determination of reactive oxygen species (ROS) - mainly hydrogen peroxide (H2O2) - in aerosol samples such as airborne nanoparticles and exhaled air from patients. The detection principle relies on the amplification of the absorbance under multiple scattering conditions due to optical path lengthening [1] and [2]. In this study, the presence of cellulose membrane that acts as random medium into the glass optical cell considerably improved the sensitivity of the detection based on colorimetric FOX assay (FeII/orange xylenol). Despite the loss of assay volume (cellulose occupies 75% of cell volume) the limit of detection is enhanced by one order of magnitude reaching the value of 9 nM (H2O2 equivalents). Spectral analysis is performed automatically with a periodicity of 5 to 15 s, giving rise to real-time ROS measurements. Moreover, the elution of air sample into the collection chamber via a micro-diffuser (impinger) enables quantitative determination of ROS contained in or generated from airborne samples. As proof-of-concept the photonic ROS detection system was used in the determination of both ROS generated from traffic pollution and ROS contained in the exhaled breath as lung inflammation biomarkers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: There is now solid evidence for a relation between adverse life events (ALE) and psychotic symptoms in patients with psychosis and in the general population. A recent study has shown that this relation may be partially mediated by stress sensitivity, suggesting the influence of other factors. The aim of this study was to assess the mediation effect of emotion regulation strategies and stress sensitivity in the relation between ALE and attenuated positive psychotic symptoms (APPS) in the general population. METHODS: Hundred and twelve healthy volunteers were evaluated with measures of APPS, emotion regulation strategies, ALE and stress sensitivity. RESULTS: Results demonstrated that the relation between ALE, hallucination and delusion proneness was completely mediated by maladaptive emotion regulation strategies, but not by stress sensitivity. However, in addition to maladaptive emotion regulation strategies, stress sensitivity demonstrated a mediation effect between ALE and attenuated positive psychotic positive symptoms when positive psychotic symptoms were grouped together. CONCLUSIONS: There are probably several possible trajectories leading to the formation of positive psychotic symptoms and the results of the present study reveal that one such trajectory may involve the maladaptive regulation of negative emotions alongside a certain general vulnerability after experiencing ALE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiovascular disease is the leading cause of death worldwide. Within this subset, coronary artery disease (CAD) is the most prevalent. Magnetic resonance angiography (MRA) is an emerging technique that provides a safe, non-invasive way of assessing CAD progression. To generate contrast between tissues, MR images are weighted according to the magnetic properties of those tissues. In cardiac MRI, T2 contrast, which is governed by the rate of transverse signal loss, is often created through the use of a T2-Preparation module. T2-Preparation, or T2-Prep, is a magnetization preparation scheme used to improve blood/myocardium contrast in cardiac MRI. T2-Prep methods generally use a non-selective +90°, 180°, 180°, -90° train of radiofrequency (RF) pulses (or variant thereof), to tip magnetization into the transverse plane, allow it to evolve, and then to restore it to the longitudinal plane. A key feature in this process is the combination of a +90° and -90° RF pulse. By changing either one of these, a mismatch occurs between signal excitation and restoration. This feature can be exploited to provide additional spectral or spatial selectivity. In this work, both of these possibilities are explored. The first - spectral selectivity - has been examined as a method of improving fat saturation in coronary MRA. The second - spatial selectivity - has been examined as a means of reducing imaging time by decreasing the field of view, and as a method of reducing artefacts originating from the tissues surrounding the heart. Two additional applications, parallel imaging and self-navigation, are also presented. This thesis is thus composed of four sections. The first, "A Fat Signal Suppression for Coronary MRA at 3T using a Water-Selective Adiabatic T2-Preparation Technique", was originally published in the journal Magnetic Resonance in Medicine (MRM) with co-authors Ruud B. van Heeswijk and Matthias Stuber. The second, "Combined T2-Preparation and 2D Pencil Beam Inner Volume Selection", again with co-authors Ruud van Heeswijk and Matthias Stuber, was also published in the journal MRM. The third, "A cylindrical, inner volume selecting 2D-T2-Prep improves GRAPPA-accelerated image quality in MRA of the right coronary artery", written with co-authors Jerome Yerly and Matthias Stuber, has been submitted to the "Journal of Cardiovascular Magnetic Resonance", and the fourth, "Combined respiratory self-navigation and 'pencil-beam' 2D-T2 -Prep for free-breathing, whole-heart coronary MRA", with co¬authors Jerome Chaptinel, Giulia Ginami, Gabriele Bonanno, Simone Coppo, Ruud van Heeswijk, Davide Piccini, and Matthias Stuber, is undergoing internal review prior to submission to the journal MRM. -- Les maladies cardiovasculaires sont la cause principale de décès dans le monde : parmi celles-ci, les maladies coronariennes sont les plus répandues. L'angiographie par résonance magnétique (ARM) est une technique émergente qui fournit une manière sûre, non invasive d'évaluer la progression de la coronaropathie. Pour obtenir un contraste entre les tissus, les images d'IRM sont pondérées en fonction des propriétés magnétiques de ces tissus. En IRM cardiaque, le contraste en T2, qui est lié à la décroissance du signal transversal, est souvent créé grâce à l'utilisàtion d'un module de préparation T2. La préparation T2, ou T2-Prep, est un système de préparation de l'aimantation qui est utilisé pour améliorer le contraste entre le sang et le myocarde lors d'une IRM cardiaque. Les méthodes de T2-Prep utilisent généralement une série non-sélective d'impulsions de radiofréquence (RF), typiquement [+ 90°, 180°, 180°, -90°] ou une variante, qui bascule l'aimantation dans le plan transversal, lui permet d'évoluer, puis la restaure dans le plan longitudinal. Un élément clé de ce processus est la combinaison des impulsions RF de +90° et -90°. En changeant l'une ou l'autre des impulsions, un décalage se produit entre l'excitation du signal et de la restauration. Cette fonction peut être exploitée pour fournir une sélectivité spectrale ou spatiale. Dans cette thèse, les deux possibilités sont explorées. La première - la sélectivité spectrale - a été examinée comme une méthode d'améliorer la saturation de la graisse dans l'IRM coronarienne. La deuxième - la sélectivité spatiale - a été étudiée comme un moyen de réduire le temps d'imagerie en diminuant le champ de vue, et comme une méthode de réduction des artefacts provenant des tissus entourant le coeur. Deux applications supplémentaires, l'imagerie parallèle et la self-navigation, sont également présentées. Cette thèse est ainsi composée de quatre sections. La première, "A Fat Signal Suppression for Coronary MRA at 3T using a Water-Selective Adiabatic T2-Preparation Technique", a été publiée dans la revue médicale Magnetic Resonance .in Medicine (MRM) avec les co-auteurs Ruud B. van Heeswijk et Matthias Stuber. La deuxième, Combined T2-Preparation and 2D Pencil Beam Inner Volume Selection", encore une fois avec les co-auteurs Ruud van Heeswijk et Matthias Stuber, a également été publiée dans le journal MRM. La troisième, "A cylindrical, inner volume selecting 2D-T2-Prep improves GRAPPA- accelerated image quality in MRA of the right coronary artery", écrite avec les co-auteurs Jérôme Yerly et Matthias Stuber, a été présentée au "Journal of Cardiovascular Magnetic Resonance", et la quatrième, "Combined respiratory self-navigation and 'pencil-beam' 2D-T2 -Prep for free-breathing, whole-heart coronary MRA", avec les co-auteurs Jérôme Chaptinel, Giulia Ginami, Gabriele Bonanno , Simone Coppo, Ruud van Heeswijk, Davide Piccini, et Matthias Stuber, subit un examen interne avant la soumission à la revue MRM.