313 resultados para intraocular prosthesis


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wear of polyethylene is associated with aseptic loosening of orthopaedic implants and has been observed in hip and knee prostheses and anatomical implants for the shoulder. The reversed shoulder prostheses have not been assessed as yet. We investigated the volumetric polyethylene wear of the reversed and anatomical Aequalis shoulder prostheses using a mathematical musculoskeletal model. Movement and joint stability were achieved by EMG-controlled activation of the muscles. A non-constant wear factor was considered. Simulated activities of daily living were estimated from in vivo recorded data. After one year of use, the volumetric wear was 8.4 mm(3) for the anatomical prosthesis, but 44.6 mm(3) for the reversed version. For the anatomical prosthesis the predictions for contact pressure and wear were consistent with biomechanical and clinical data. The abrasive wear of the polyethylene in reversed prostheses should not be underestimated, and further analysis, both experimental and clinical, is required.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cataract surgery is the most frequent surgery performed in the world. Modernization of cataract surgery is a continuous process and recent technological progress have enlarged the spectrum of treatable refractive errors, improved safety of surgery, speed of visual recovery and reduction of complications rate. Thus, during the last years, refractive intraocular lenses such as toric and multifocal IOLS have been introduced in practice, as well as torsional phacoemulsification and corneal microincision. For endophthalmitis prophylaxis, modern management includes intracameral injection of antibiotics. The future of cataract surgery is probably to replace phacoemulsification surgery by laser surgery, which is safer and more reproducible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

HYPOTHESIS: The nonanatomical design of reverse shoulder prostheses induce medial displacement of the center of rotation, impingements and may reduce the mobility of the shoulder. The aim of this study is to test the hypothesis that during activities of daily living functional mobility of the shoulder can be restored by scapular compensation. MATERIAL AND METHODS: A numerical 3-dimensional model was developed to reproduce the movement of the scapula and humerus, during 4 activities of daily living measured experimentally. This hypothesis was tested in 4 configurations of the aequalis reverse prosthesis (standard 36-mm glenosphere, 42-mm glenosphere, lateralized 36-mm glenosphere, lateralized Bony Increased-Offset Reverse Shoulder Arthroplasty [BIO-RSA]), which were implanted in the virtual model. All impingement positions were evaluated, as the required scapular compensation to avoid impingements. RESULTS: With the 36-mm glenosphere, impingements occurred only for rest of hand to back-pocket positions. The 42-mm partly improved the mobility. The 2 lateralized glenospheres were free of impingement. When impingements occurred, the scapular compensation was less than 10°. CONCLUSION: Most reverse prostheses impingements reported in clinical and biomechanical studies can be avoided, either by scapular compensation or by a glenosphere lateralization. After reverse shoulder arthroplasty, a fraction of the mobility of the gleno-humeral is transferred to the scapulo-thoracic joint.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Total shoulder arthroplasty (TSA) is an accepted and most successfully used treatment for different shoulder pathologies. Different risk factors for the failure of the prosthesis are known. A pathological scapular orientation, observed in elderly people or in patients suffering from neuromuscular diseases, could be a cause of failure, which has not been investigated yet. To test this hypothesis, a numerical musculoskeletal model of the glenohumeral joint was used to compare two TSA cases: a reference normal case and a case with a pathological anterior tilt of the scapula. An active abduction of 150° was simulated. Joint force, contact pattern, polyethylene and cement stress were evaluated for both cases. The pathological tilt slightly increased the joint force and the contact pressure, but also shifted the contact pattern. This eccentric contact increased the stress level within the polyethylene of the glenoid component and within the surrounding cement layer. This adverse effect occurred mainly during the first 60° of abduction. Therefore, a pathological orientation of the scapula may increase the risk of a failure of the cement layer around the glenoid component. These preliminary numerical results should be confirmed by a clinical study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Proximal femoral extracapsular fractures have shown a significantly high morbidity and mortality rate at 1 year in cases of nonoperative treatment. The standard gamma nail was originally designed to provide stable fixation and allow early mobilization and weight bearing for elderly patients. The design of the standard gamma nail, however, appears to be associated with intraoperative or postoperative femoral shaft fractures in < or = 17% of patients, compromising the outcome. The trochanteric nail was developed to overcome the problems encountered with the use of the standard gamma nail. Between July 2000 and January 2001, 88 consecutive proximal femoral extracapsular fractures were treated with a trochanteric nail, Seventy-five patients (76 fractures) were observed clinically and radiographically for 2 years.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To report the use of argon laser iridoplasty in the management of uveitic acute angle-closure glaucoma. METHODS: Interventional case report. RESULTS: A 46-year-old man developed uveitic acute angle-closure glaucoma with an intraocular pressure (IOP) of 65 mmHg. After unsuccessful attempts with medical treatment and two laser peripheral iridotomies, iridoplasty allowed to break posterior synechiae, open the angle, and reduce the IOP within a few hours. CONCLUSIONS: Argon laser iridoplasty allowed rapid reduction of IOP and prevented the need for emergency surgery. Therefore, the authors stipulate that it is a viable management option in active uveitic acute angle-closure glaucoma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Nonspecific inflammatory reactions characterized by local tenderness, fever, and flu-like discomfort have been seen in patients undergoing endoluminal graft placement in the abdominal aorta or the femoral arteries. We undertook a study to assess the clinical and laboratory parameters of this inflammation. METHODS: Ten patients with femoropopliteal artery (n = 9) or aortic (n = 1) lesions were treated with EndoPro System 1 stent-grafts made of nitinol alloy and covered with a polyester (Dacron) fabric. Eleven patients implanted with a bare nitinol stent served as the control group. RESULTS: In the stent-graft group, four patients showed clinical signs of acute inflammation manifested by fever and local tenderness. Three of these patients suffered thrombosis of the stent-grafts during the first month of follow-up. Plasma levels of interleukin-1 beta and interleukin-6 in all stent-graft patients were markedly increased 1 day after intervention (7.3 +/- 2.8 versus 90.2 +/- 34.1 pg/mL and 15.6 +/- 5.8 versus 175.5 +/- 66.3 pg/mL, respectively; p < 0.01). This was followed by an increase in fibrinogen (3.0 +/- 0.2 versus 5.0 +/- 0.2 g/L; p < 0.05) and C-reactive protein (14.6 +/- 3.3 versus 77.5 +/- 15.0 mg/L; p < 0.01) at 1 week. No direct correlation between the inflammatory markers and symptoms could be found. In vitro analysis showed that individual components of the stent-graft did not activate human neutrophils, whereas the intact stent-graft itself induced a marked neutrophil activation. CONCLUSIONS: The component of the self-expanding stent-graft responsible for the nonspecific inflammatory reaction was not identified in this study. It is likely that the stent-graft itself or some as yet unrecognized element of the device other than the Dacron fabric or metal alloy may be a potent in vivo inducer of cytokine reaction by neutrophils.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To determine the value of immunoscintigraphy (IS) with antigranulocyte monoclonal antibodies (Mab) in the diagnosis of subacute or chronic infection of hip prostheses, we prospectively studied 57 patients (23 women and 34 men; age 29-92 years, mean 72.7 years) sent to our institution in the past 6 years for clinical suspicion of septic loosening of a hip prosthesis. Nineteen patients had bilateral prostheses and one of them was studied twice. A total of 78 prostheses were examined. All patients had three-phase bone scans followed by IS with technetium-99m antigranulocyte Mab BW 250/183. Intervals between bone scans and IS varied from 2 days to 4 weeks. Final diagnosis was assessed by culture in 48 cases (articular puncture or intraoperative sampling) and by clinical follow-up of at least 8 months in 30 cases. Twelve prostheses were considered septic and 66 non-septic. The overall sensitivity and specificity were 92% and 64% respectively for bone scans, 67% and 75% for IS and 67% and 84% for both modalities together. In three cases, IS was doubtful and the final clinical diagnosis was negative for infection. False-positive results were observed in the presence of massive loosening of the prosthesis or in association with metaplastic peri-articular bone formation. In three of the four false-negative results, infection was proven only after enrichment of the culture, and the bacterium was Staphylococcus epidermidis. In 12/33 (36%) positive bone scans IS allowed the diagnosis of infection to be excluded. Overall accuracy of both modalities together was 81% and the negative predictive value was 93%, which compares favourably with the results reported for other non-invasive methods.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To determine the outcomes of vitreoretinal surgery after choroidal tumor biopsy. DESIGN: Retrospective, single-center, consecutive case series. PARTICIPANTS: A total of 739 consecutive patients undergoing choroidal tumor biopsy. METHODS: All subjects who underwent transretinal or transscleral choroidal tumor biopsy for diagnostic or prognostic purposes between May 1993 and May 2013 were identified in our database. We then reviewed patients who subsequently required secondary vitreoretinal surgery for complications arising from such biopsies. MAIN OUTCOME MEASURES: Reason for vitreoretinal surgery, association with biopsy procedure, best-corrected visual acuity (BCVA; logarithm of the minimum angle of resolution [logMAR]), intraocular or extrascleral tumor dissemination, resolution of vitreous hemorrhage, reattachment of the retina with a single vitreoretinal procedure, number of additional vitrectomies undertaken, and number of enucleations. RESULTS: A total of 20 of 739 eyes (2.7%) underwent vitreoretinal surgery for complications arising from choroidal tumor biopsy. The tumors consisted of choroidal melanoma in all 20 eyes. The reasons for the secondary surgery included persistent vitreous hemorrhage in 1.9% (14/739), rhegmatogenous retinal detachment in 0.7% (5/739), and endophthalmitis in 0.14% (1/739). Median BCVA improved from 2.0 logMAR (mean, 1.92 logMAR; range, 0.8-2.7 logMAR) before vitrectomy to 0.72 logMAR (mean, 0.88 logMAR; range, -0.14 to 2.7 logMAR) after vitrectomy and 0.76 logMAR (mean, 1.14 logMAR; range, 0.1-3.0 logMAR) at the final visit (P < 0.0001, t test). Permanent resolution of vitreous hemorrhage was achieved in 6 of 14 patients, and reattachment of the retina was achieved in 2 of 5 patients after the first vitrectomy. A median of 1 (mean, 1.5; range, 1-3) additional vitrectomy was performed. Enucleation was necessary in 3 of 20 eyes (15%). There were no cases of intraocular invasion or extrascleral extension after vitrectomy. CONCLUSIONS: Vitrectomy for complications of choroidal tumor biopsy is rare. Such corrective surgery is complex and is best undertaken by specialized ocular oncologists or vitreoretinal surgeons with experience in managing this problem.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: An objective measurement of surgical procedures outcomes is inherent to professional practices quality control; this especially applies in orthopaedics to joint replacement outcomes. A self-administered questionnaire offers an attractive alternative to surgeon's judgement but is infrequently used in France for these purposes. The British questionnaire, the 12-item Oxford Hip Score (OHS) was selected for this study because of its ease of use. HYPOTHESIS: The objective of this study was to validate the French translation of the self-assessment 12-item Oxford Hip Score and compare its results with those of the reference functional scores: the Harris Hip Score (HHS) and the Postel-Merle d'Aubigné (PMA) score. MATERIALS AND METHODS: Based on a clinical series of 242 patients who were candidates for total hip arthroplasty, the French translation of this questionnaire was validated. Its coherence was also validated by comparing the preoperative data with the data obtained from the two other reference clinical scores. RESULTS: The translation was validated using the forward-backward translation procedure from French to English, with correction of all differences or mistranslations after systematized comparison with the original questionnaire in English. The mean overall OHS score was 43.8 points (range, 22-60 points) with similarly good distribution of the overall value of the three scores compared. The correlation was excellent between the OHS and the HHS, but an identical correlation between the OHS and the PMA was only obtained for the association of the pain and function parameters, after excluding the mobility criterion, relatively over-represented in the PMA score. DISCUSSION AND CONCLUSION: Subjective questionnaires that contribute a personal appreciation of the results of arthroplasty by the patient can easily be applied on a large scale. This study made a translated and validated version of an internationally recognized, reliable self-assessment score available to French orthopaedic surgeons. The results obtained encourage us to use this questionnaire as a complement to the classical evaluation scores and methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The objective of this study was to evaluate the long-term safety and pharmacokinetic profile of a dexamethasone-loaded poly-epsilon-caprolactone (PCL) intravitreous implant. METHODS: The PCL devices were prepared by compression and were inserted into the vitreous of pigmented rabbits. At different time points, vitreous samples were retrieved, and dexamethasone concentration was analyzed by high-performance liquid chromatography. The biodegradation of the implants was evaluated by scanning electron microscopy, and the dexamethasone remaining was evaluated at the end of follow-up. Clinical and histologic examinations were performed to evaluate the implant's tolerance. RESULTS: The PCL implant allows for a controlled and prolonged delivery of dexamethasone in rabbits eyes since it released the drug within the therapeutic range for at least 55 weeks. At 55 weeks approximately 79% of the drug was still present in the implant. Biodegradation study showed that PCL implants degradation is very slow. Clinical and histologic observations showed that the devices were very well tolerated in the rabbit eye. CONCLUSIONS: This study demonstrates the feasibility and tolerance of intravitreous PCL drug delivery systems, which can offer a wide range of applications for intraocular drug delivery because of their controlled and prolonged release over months or even years.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the ageing of the population, articular prosthetic replacements are becoming more and more frequent. One of the most feared complications is prosthetic infection, mostly due to bacteria of the cutaneous flora. Listeria monocytogenes is rarely the cause. This paper describes the management of a hip prosthetic infection due to Listeria monocytogenes. The patient was cured with antimicrobial therapy and a two-stage exchange. This case report creates an opportunity to review the literature in the aim of determining the risk factors and the optimal care.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Several studies have reported significant alteration of the scapula-humeral rythm after total shoulder arthroplasty. However, the biomechanical and clinical effects, particularly on implants lifespan, are still unknown. The goal of this study was to evaluate the biomechanical consequences of an altered scapula-humeral rhythm. Methods: A numerical musculoskeletal model of the shoulder was used. The model included the scapula, the humerus and 6 scapulohumeral muscles: middle, anterior, and posterior deltoid, supraspinatus, subscapularis and infraspinatus combined with teres minor. Arm motion and joint stability were achieved by muscles. The reverse and anatomic Aequalis prostheses (Tornier Inc) were inserted. Two scapula-humeral rhythms were considered for each prosthesis: a normal 2:1 rhythm, and an altered 1:2 rhythm. For the 4 configurations, a movement of abduction in the scapular plane was simulated. The gleno-humeral force and contact pattern, but also the stress in the polyethylene and cement were evaluated. Results: With the anatomical prosthesis, the gleno-humeral force increased of 23% for the altered rhythm, with a more eccentric (posterior and superior) contact. The contact pressure, polyethylene stress, and cement stress increased respectively by 20%, 48% and 64%. With the reverse prosthesis, the gleno-humeral force increased of 11% for an altered rhythm. There was nearly no effect on the contact pattern on the polyethylene component surface. Conclusion: The present study showed that alteration oft the scapula-humeral rythm induced biomechanical consequences which could preclude the long term survival of the glenoid implant of anatomic prostheses. However,an altered scapula-humeral rhythm, even severe, should not be a contra indication for the use of a reverse prosthesis.