129 resultados para heart left ventricle filling


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: Levosimendan, a calcium-sensitizing agent has been reported as useful for the management of patients with low cardiac output state. We report here our experience, safety and efficacy of use of levosimendan as rescue therapy after surgery for congenital heart disease. Methods: Retrospective cohort study on patients necessitating levosimendan therapy for post operative low cardiac output or severe post operative systolic and diastolic dysfunction. Twelve patients with a mean age of 2.1 years (range 7 days - 14 years old) received levosimendan. Type of surgery: 3 arterial switch, 3 correction of complete abnormal pulmonary venous return, 3 closure of VSD and correction of aortic coarctation, 3 Tetralogy of Fallot, one correction of truncus arteriosus and one palliation for single ventricle. The mean time of ECC was 203 +/- 81min. Ten patients received levosimendan for low cardiac output not responding to conventional therapy in these cases (milrinone, dopamine and noradrenaline) in the first 6 hours following entry in the ICU and 3 patients received levosimendan 3-4 days after surgery for severe systolic and diastolic dysfunction. Levosimendan was given as a drip for 24-48 hours at the dose of 0.1-0.2 mcg/ kg/min, without loading dose. Results: Significant changes were noted on mean plasmatic lactate (3.3 +/- 1.7mmole/L vs 1.8 +/-0.6mmole/L, p+0.01), mean central venous saturation (55 +/- 11% vs 68 +/- 10%, p+0.01) and mean arterio-venous difference in CO2 (9.6 +/- 4.9mmHg vs 6.7 +/- 2.1mmHg, p+0.05) for values before and at the end of levosimendan administration. There was no significant changes on heart rate, systolic pressure or central venous pressure. No adverse effect was observed. Conclusion: Levosimendan, used as rescue therapy after surgery for congenital heart disease, is safe and improves cardiac output as demonstrated with improvement of parameters commonly used clinically.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: A hybrid intervention is a joint procedure involving the interventional cardiologist and the cardiac surgeon. At our institution we have opted for this type of approach in congenital heart disease since 2005. We report here our initial experience. Cases: 1. A 3 year old boy with double aortic arch and multiple muscular ventricular septal defects (VSD),was readdressed for pulmonary band (PAB) removal and residual VSD closure after previous palliation. After surgical removal of the PAB, the surgeon provided a minimal transventricular access for placement of a 6mm Amplatzer® muscular VSD occluder by the cardiologist under transoesophageal guidance. The patient was extubated the same day and discharged after 5 days. 2. An 8 year old girl with Williams syndrome was followed for two large VSDs and severe peripheral pulmonary arteries (PA) stenosis. The membranous VSD was closed surgically, the muscular VSD during the same operation by direct placement of a 12 mm Amplatzer® muscular VSD occluder. During rewarming, balloon angioplasty of peripheral PA stenosis was achieved under fluoroscopy. Patient was extubated the following day and discharged after 8 days. 3. A 9 year old boy post tetralogy of Fallot repair had severe distal stenosis of the right ventricular to PA conduit.With patient on partial cardiopulmonary bypass, an incision was made on the conduit and a CP 8 Zig 16 stent placed on the stenosis. The child passed on full bypass and the definitive placement of the stent achieved. The child was extubated at the end of the intervention and discharged after 6 days. 4. A newborn presented at 2 days life with complex aortic arch anatomy: left aortic arch and right descending thoracic aorta perfused directly from a right arterial duct and left PA atresia. The arterial duct was stented with a Genesis XD stent dilated at 7mm. Two days later the cardiac surgeon made banded the right PA. The child was extubated after the operation and discharged a week later. Conclusion: Hybrid approach opens new ways of correction or palliation in congenital heart disease with encouraging results and less morbidity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Existing VADs are single-ventricle pumps needing anticoagulation. We developed a bi ventricular external assist device that reproduces the physiological heart muscle movement completely avoiding anticoagulants. Methods: The device has a carbon fibre skeleton fitting a 30-40 kg patient's heart, to which a Nitinol based artificial muscle is connected. The artificial muscle wraps both ventricles. The strength of the Nitinol fibres is amplified by a pivot articulation in contact with the ventricle wall. The fibres are electrically driven and a dedicated control unit has been developed. We assessed hemodynamic performances of this device using a previously described dedicated bench test. Volume ejected and pressure gradient has been measured with afterload ranging from 25 to 50mmHg. Results: With anafterload of 50mmHg the system has an ejection fraction (EF) of 10% on the right side and 8% on the left side. The system is able to generate a systolic ejection of 5,5 ml on the right side and 4,4 ml on the left side. With anafterload of 25mmHg the results are reduced of about 20%. The activation frequency is 80/minute resulting in a total volume displacement of 440 ml/minute on the right side and 352 ml/minute on the left side. Conclusions: The artificial muscle follows Starling's law as the ejected volume increases when afterload increases. These preliminary studies confirmed the possibility of improving the EF of a failing heart using artificial muscle for external cardiac compression. This device could be helpful in weaning CPB and/or for short-term cardio-circulatory support in paediatric population with cardiac failure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Left ventricular hypertrophy (LVH) is due to pressure overload or mechanical stretch and is thought to be associated with remodeling of gap-junctions. We investigated whether the expression of connexin 43 (Cx43) is altered in humans in response to different degrees of LVH. The expression of Cx43 was analyzed by quantitative polymerase chain reaction, Western blot analysis and immunohistochemistry on left ventricular biopsies from patients undergoing aortic or mitral valve replacement. Three groups were analyzed: patients with aortic stenosis with severe LVH (n=9) versus only mild LVH (n=7), and patients with LVH caused by mitral regurgitation (n=5). Cx43 mRNA expression and protein expression were similar in the three groups studied. Furthermore, immunohistochemistry revealed no change in Cx43 distribution. We can conclude that when compared with mild LVH or with LVH due to volume overload, severe LVH due to chronic pressure overload is not accompanied by detectable changes of Cx43 expression or spatial distribution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Left atrial (LA) dilatation is associated with a large variety of cardiac diseases. Current cardiovascular magnetic resonance (CMR) strategies to measure LA volumes are based on multi-breath-hold multi-slice acquisitions, which are time-consuming and susceptible to misregistration. AIM: To develop a time-efficient single breath-hold 3D CMR acquisition and reconstruction method to precisely measure LA volumes and function. METHODS: A highly accelerated compressed-sensing multi-slice cine sequence (CS-cineCMR) was combined with a non-model-based 3D reconstruction method to measure LA volumes with high temporal and spatial resolution during a single breath-hold. This approach was validated in LA phantoms of different shapes and applied in 3 patients. In addition, the influence of slice orientations on accuracy was evaluated in the LA phantoms for the new approach in comparison with a conventional model-based biplane area-length reconstruction. As a reference in patients, a self-navigated high-resolution whole-heart 3D dataset (3D-HR-CMR) was acquired during mid-diastole to yield accurate LA volumes. RESULTS: Phantom studies. LA volumes were accurately measured by CS-cineCMR with a mean difference of -4.73 ± 1.75 ml (-8.67 ± 3.54%, r2 = 0.94). For the new method the calculated volumes were not significantly different when different orientations of the CS-cineCMR slices were applied to cover the LA phantoms. Long-axis "aligned" vs "not aligned" with the phantom long-axis yielded similar differences vs the reference volume (-4.87 ± 1.73 ml vs. -4.45 ± 1.97 ml, p = 0.67) and short-axis "perpendicular" vs. "not-perpendicular" with the LA long-axis (-4.72 ± 1.66 ml vs. -4.75 ± 2.13 ml; p = 0.98). The conventional bi-plane area-length method was susceptible for slice orientations (p = 0.0085 for the interaction of "slice orientation" and "reconstruction technique", 2-way ANOVA for repeated measures). To use the 3D-HR-CMR as the reference for LA volumes in patients, it was validated in the LA phantoms (mean difference: -1.37 ± 1.35 ml, -2.38 ± 2.44%, r2 = 0.97). Patient study: The CS-cineCMR LA volumes of the mid-diastolic frame matched closely with the reference LA volume (measured by 3D-HR-CMR) with a difference of -2.66 ± 6.5 ml (3.0% underestimation; true LA volumes: 63 ml, 62 ml, and 395 ml). Finally, a high intra- and inter-observer agreement for maximal and minimal LA volume measurement is also shown. CONCLUSIONS: The proposed method combines a highly accelerated single-breathhold compressed-sensing multi-slice CMR technique with a non-model-based 3D reconstruction to accurately and reproducibly measure LA volumes and function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrical impedance tomography (EIT) is a non-invasive imaging technique that can measure cardiac-related intra-thoracic impedance changes. EIT-based cardiac output estimation relies on the assumption that the amplitude of the impedance change in the ventricular region is representative of stroke volume (SV). However, other factors such as heart motion can significantly affect this ventricular impedance change. In the present case study, a magnetic resonance imaging-based dynamic bio-impedance model fitting the morphology of a single male subject was built. Simulations were performed to evaluate the contribution of heart motion and its influence on EIT-based SV estimation. Myocardial deformation was found to be the main contributor to the ventricular impedance change (56%). However, motion-induced impedance changes showed a strong correlation (r = 0.978) with left ventricular volume. We explained this by the quasi-incompressibility of blood and myocardium. As a result, EIT achieved excellent accuracy in estimating a wide range of simulated SV values (error distribution of 0.57 ± 2.19 ml (1.02 ± 2.62%) and correlation of r = 0.996 after a two-point calibration was applied to convert impedance values to millilitres). As the model was based on one single subject, the strong correlation found between motion-induced changes and ventricular volume remains to be verified in larger datasets.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To test the hypothesis that both coronary anatomy and ventricular function can be assessed simultaneously using a single four-dimensional (4D) acquisition. METHODS: A free-running 4D whole-heart self-navigated acquisition incorporating a golden angle radial trajectory was implemented and tested in vivo in nine healthy adult human subjects. Coronary magnetic resonance angiography (MRA) datasets with retrospective selection of acquisition window width and position were extracted and quantitatively compared with baseline self-navigated electrocardiography (ECG) -triggered coronary MRA. From the 4D datasets, the left-ventricular end-systolic, end-diastolic volumes (ESV & EDV) and ejection fraction (EF) were computed and compared with values obtained from conventional 2D cine images. RESULTS: The 4D datasets enabled dynamic assessment of the whole heart with isotropic spatial resolution of 1.15 mm(3) . Coronary artery image quality was very similar to that of the ECG-triggered baseline scan despite some SNR penalty. A good agreement between 4D and 2D cine imaging was found for EDV, ESV, and EF. CONCLUSION: The hypothesis that both coronary anatomy and ventricular function can be assessed simultaneously in vivo has been tested positive. Retrospective and flexible acquisition window selection allows to best visualize each coronary segment at its individual time point of quiescence. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: For free-breathing cardiovascular magnetic resonance (CMR), the self-navigation technique recently emerged, which is expected to deliver high-quality data with a high success rate. The purpose of this study was to test the hypothesis that self-navigated 3D-CMR enables the reliable assessment of cardiovascular anatomy in patients with congenital heart disease (CHD) and to define factors that affect image quality. METHODS: CHD patients ≥2 years-old and referred for CMR for initial assessment or for a follow-up study were included to undergo a free-breathing self-navigated 3D CMR at 1.5T. Performance criteria were: correct description of cardiac segmental anatomy, overall image quality, coronary artery visibility, and reproducibility of great vessels diameter measurements. Factors associated with insufficient image quality were identified using multivariate logistic regression. RESULTS: Self-navigated CMR was performed in 105 patients (55% male, 23 ± 12y). Correct segmental description was achieved in 93% and 96% for observer 1 and 2, respectively. Diagnostic quality was obtained in 90% of examinations, and it increased to 94% if contrast-enhanced. Left anterior descending, circumflex, and right coronary arteries were visualized in 93%, 87% and 98%, respectively. Younger age, higher heart rate, lower ejection fraction, and lack of contrast medium were independently associated with reduced image quality. However, a similar rate of diagnostic image quality was obtained in children and adults. CONCLUSION: In patients with CHD, self-navigated free-breathing CMR provides high-resolution 3D visualization of the heart and great vessels with excellent robustness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The majority of transcatheter aortic valve implantations, structural heart procedures and the newly developed transcatheter mitral valve repair and replacement are traditionally performed either through a transfemoral or a transapical access site, depending on the presence of severe peripheral vascular disease or anatomic limitations. The transapical approach, which carries specific advantages related to its antegrade nature and the short distance between the introduction site and the cardiac target, is traditionally performed through a left anterolateral mini-thoracotomy and requires rib retractors, soft tissue retractors and reinforced apical sutures to secure, at first, the left ventricular apex for the introduction of the stent-valve delivery systems and then to seal the access site at the end of the procedure. However, despite the advent of low-profile apical sheaths and newly designed delivery systems, the apical approach represents a challenge for the surgeon, as it has the risk of apical tear, life-threatening apical bleeding, myocardial damage, coronary damage and infections. Last but not least, the use of large-calibre stent-valve delivery systems and devices through standard mini-thoracotomies compromises any attempt to perform transapical transcatheter structural heart procedures entirely percutaneously, as happens with the transfemoral access site, or via a thoracoscopic or a miniaturised video-assisted percutaneous technique. During the past few years, prototypes of apical access and closure devices for transapical heart valve procedures have been developed and tested to make this standardised successful procedure easier. Some of them represent an important step towards the development of truly percutaneous transcatheter transapical heart valve procedures in the clinical setting.