157 resultados para electrical measurements


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A geophysical and geochemical study has been conducted in a fractured carbonate aquifer located at Combioula in the southwestern Swiss Alps with the objective to detect and characterize hydraulically active fractures along a 260-m-deep borehole. Hydrochemical analyses, borehole diameter, temperature and fluid electrical conductivity logging data were integrated in order to relate electrokinetic self-potential signals to groundwater flow inside the fracture network. The results show a generally good, albeit locally variable correlation of variations of the self-potential signals with variations in temperature, fluid electrical conductivity and borehole diameter. Together with the hydrochemical evidence, which was found to be critical for the interpretation of the self-potential data, these measurements not only made it possible to detect the hydraulically active fractures but also to characterize them as zones of fluid gain or fluid loss. The results complement the available information from the corresponding litholog and illustrate the potential of electrokinetic self-potential signals in conjunction with temperature, fluid electrical conductivity and hydrochemical analyses for the characterization of fractured aquifers, and thus may offer a perspective for an effective quantitative characterization of this increasingly important class of aquifers and geothermal reservoirs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have constructed a forward modelling code in Matlab, capable of handling several commonly used electrical and electromagnetic methods in a 1D environment. We review the implemented electromagnetic field equations for grounded wires, frequency and transient soundings and present new solutions in the case of a non-magnetic first layer. The CR1Dmod code evaluates the Hankel transforms occurring in the field equations using either the Fast Hankel Transform based on digital filter theory, or a numerical integration scheme applied between the zeros of the Bessel function. A graphical user interface allows easy construction of 1D models and control of the parameters. Modelling results are in agreement with other authors, but the time of computation is less efficient than other available codes. Nevertheless, the CR1Dmod routine handles complex resistivities and offers solutions based on the full EM-equations as well as the quasi-static approximation. Thus, modelling of effects based on changes in the magnetic permeability and the permittivity is also possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The spatial resolution visualized with hydrological models and the conceptualized images of subsurface hydrological processes often exceed resolution of the data collected with classical instrumentation at the field scale. In recent years it was possible to increasingly diminish the inherent gap to information from point like field data through the application of hydrogeophysical methods at field-scale. With regards to all common geophysical exploration techniques, electric and electromagnetic methods have arguably to greatest sensitivity to hydrologically relevant parameters. Of particular interest in this context are induced polarisation (IP) measurements, which essentially constrain the capacity of a probed subsurface region to store an electrical charge. In the absence of metallic conductors the IP- response is largely driven by current conduction along the grain surfaces. This offers the perspective to link such measurements to the characteristics of the solid-fluid-interface and thus, at least in unconsolidated sediments, should allow for first-order estimates of the permeability structure.¦While the IP-effect is well explored through laboratory experiments and in part verified through field data for clay-rich environments, the applicability of IP-based characterizations to clay-poor aquifers is not clear. For example, polarization mechanisms like membrane polarization are not applicable in the rather wide pore-systems of clay free sands, and the direct transposition of Schwarz' theory relating polarization of spheres to the relaxation mechanism of polarized cells to complex natural sediments yields ambiguous results.¦In order to improve our understanding of the structural origins of IP-signals in such environments as well as their correlation with pertinent hydrological parameters, various laboratory measurements have been conducted. We consider saturated quartz samples with a grain size spectrum varying from fine sand to fine gravel, that is grain diameters between 0,09 and 5,6 mm, as well as corresponding pertinent mixtures which can be regarded as proxies for widespread alluvial deposits. The pore space characteristics are altered by changing (i) the grain size spectra, (ii) the degree of compaction, and (iii) the level of sorting. We then examined how these changes affect the SIP response, the hydraulic conductivity, and the specific surface area of the considered samples, while keeping any electrochemical variability during the measurements as small as possible. The results do not follow simple assumptions on relationships to single parameters such as grain size. It was found that the complexity of natural occurring media is not yet sufficiently represented when modelling IP. At the same time simple correlation to permeability was found to be strong and consistent. Hence, adaptations with the aim of better representing the geo-structure of natural porous media were applied to the simplified model space used in Schwarz' IP-effect-theory. The resulting semi- empiric relationship was found to more accurately predict the IP-effect and its relation to the parameters grain size and permeability. If combined with recent findings about the effect of pore fluid electrochemistry together with advanced complex resistivity tomography, these results will allow us to picture diverse aspects of the subsurface with relative certainty. Within the framework of single measurement campaigns, hydrologiste can than collect data with information about the geo-structure and geo-chemistry of the subsurface. However, additional research efforts will be necessary to further improve the understanding of the physical origins of IP-effect and minimize the potential for false interpretations.¦-¦Dans l'étude des processus et caractéristiques hydrologiques des subsurfaces, la résolution spatiale donnée par les modèles hydrologiques dépasse souvent la résolution des données du terrain récoltées avec des méthodes classiques d'hydrologie. Récemment il est possible de réduire de plus en plus cet divergence spatiale entre modèles numériques et données du terrain par l'utilisation de méthodes géophysiques, notamment celles géoélectriques. Parmi les méthodes électriques, la polarisation provoquée (PP) permet de représenter la capacité des roches poreuses et des sols à stocker une charge électrique. En l'absence des métaux dans le sous-sol, cet effet est largement influencé par des caractéristiques de surface des matériaux. En conséquence les mesures PP offrent une information des interfaces entre solides et fluides dans les matériaux poreux que nous pouvons lier à la perméabilité également dirigée par ces mêmes paramètres. L'effet de la polarisation provoquée à été étudié dans différentes études de laboratoire, ainsi que sur le terrain. A cause d'une faible capacité de polarisation des matériaux sableux, comparé aux argiles, leur caractérisation par l'effet-PP reste difficile a interpréter d'une manière cohérente pour les environnements hétérogènes.¦Pour améliorer les connaissances sur l'importance de la structure du sous-sol sableux envers l'effet PP et des paramètres hydrologiques, nous avons fait des mesures de laboratoire variées. En détail, nous avons considéré des échantillons sableux de quartz avec des distributions de taille de grain entre sables fins et graviers fins, en diamètre cela fait entre 0,09 et 5,6 mm. Les caractéristiques de l'espace poreux sont changées en modifiant (i) la distribution de taille des grains, (ii) le degré de compaction, et (iii) le niveau d'hétérogénéité dans la distribution de taille de grains. En suite nous étudions comment ces changements influencent l'effet-PP, la perméabilité et la surface spécifique des échantillons. Les paramètres électrochimiques sont gardés à un minimum pendant les mesures. Les résultats ne montrent pas de relation simple entre les paramètres pétro-physiques comme par exemples la taille des grains. La complexité des media naturels n'est pas encore suffisamment représenté par les modèles des processus PP. Néanmoins, la simple corrélation entre effet PP et perméabilité est fort et consistant. En conséquence la théorie de Schwarz sur l'effet-PP a été adapté de manière semi-empirique pour mieux pouvoir estimer la relation entre les résultats de l'effet-PP et les paramètres taille de graines et perméabilité. Nos résultats concernant l'influence de la texture des matériaux et celles de l'effet de l'électrochimie des fluides dans les pores, permettront de visualiser des divers aspects du sous-sol. Avec des telles mesures géo-électriques, les hydrologues peuvent collectionner des données contenant des informations sur la structure et la chimie des fluides des sous-sols. Néanmoins, plus de recherches sur les origines physiques de l'effet-PP sont nécessaires afin de minimiser le risque potentiel d'une mauvaise interprétation des données.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of motor training using closed loop controlled Functional Electrical Stimulation (FES) on motor performance was studied in 5 spinal cord injured (SCI) volunteers. The subjects trained 2 to 3 times a week during 2 months on a newly developed rehabilitation robot (MotionMaker?). The FES induced muscle force could be adequately adjusted throughout the programmed exercises by the way of a closed loop control of the stimulation currents. The software of the MotionMaker? allowed spasms to be detected accurately and managed in a way to prevent any harm to the SCI persons. Subjects with incomplete SCI reported an increased proprioceptive awareness for motion and were able to achieve a better voluntary activation of their leg muscles during controlled FES. At the end of the training, the voluntary force of the 4 incomplete SCI patients was found increased by 388% on their most affected leg and by 193% on the other leg. Active mobilisation with controlled FES seems to be effective in improving motor function in SCI persons by increasing the sensory input to neuronal circuits involved in motor control as well as by increasing muscle strength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Current indications for therapeutic hypothermia (TH) are restricted to comatose patients with cardiac arrest (CA) due to ventricular fibrillation (VF) and without circulatory shock. Additional studies are needed to evaluate the benefit of this treatment in more heterogeneous groups of patients, including those with non-VF rhythms and/or shock and to identify early predictors of outcome in this setting. DESIGN: Prospective study, from December 2004 to October 2006. SETTING: 32-bed medico-surgical intensive care unit, university hospital. PATIENTS: Comatose patients with out-of-hospital CA. INTERVENTIONS: TH to 33 +/- 1 degrees C (external cooling, 24 hrs) was administered to patients resuscitated from CA due to VF and non-VF (including asystole or pulseless electrical activity), independently from the presence of shock. MEASUREMENTS AND MAIN RESULTS: We hypothesized that simple clinical criteria available on hospital admission (initial arrest rhythm, duration of CA, and presence of shock) might help to identify patients who eventually survive and might most benefit from TH. For this purpose, outcome was related to these predefined variables. Seventy-four patients (VF 38, non-VF 36) were included; 46% had circulatory shock. Median duration of CA (time from collapse to return of spontaneous circulation [ROSC]) was 25 mins. Overall survival was 39.2%. However, only 3.1% of patients with time to ROSC > 25 mins survived, as compared to 65.7% with time to ROSC < or = 25 mins. Using a logistic regression analysis, time from collapse to ROSC, but not initial arrest rhythm or presence of shock, independently predicted survival at hospital discharge. CONCLUSIONS: Time from collapse to ROSC is strongly associated with outcome following VF and non-VF cardiac arrest treated with therapeutic hypothermia and could therefore be helpful to identify patients who benefit most from active induced cooling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine the incidence and risk factors of electrical seizures and other electrical epileptic activity using continuous EEG (cEEG) in patients with acute stroke. METHODS: One hundred consecutive patients with acute stroke admitted to our stroke unit underwent cEEG using 10 electrodes. In addition to electrical seizures, repetitive focal sharp waves (RSHWs), repetitive focal spikes (RSPs), and periodic lateralized epileptic discharges (PLEDs) were recorded. RESULTS: In the 100 patients, cEEG was recorded for a mean duration of 17 hours 34 minutes (range 1 hour 12 minutes to 37 hours 10 minutes). Epileptic activity occurred in 17 patients and consisted of RSHWs in seven, RSPs in seven, and PLEDs in three. Electrical seizures occurred in two patients. On univariate Cox regression analysis, predictors for electrical epileptic activity were stroke severity (high score on the National Institutes of Health Stroke Scale) (hazard ratio [HR] 1.12; p = 0.002), cortical involvement (HR 5.71; p = 0.021), and thrombolysis (HR 3.27; p = 0.040). Age, sex, stroke type, use of EEG-modifying medication, and cardiovascular risk factors were not predictors of electrical epileptic activity. On multivariate analysis, stroke severity was the only independent predictor (HR 1.09; p = 0.016). CONCLUSION: In patients with acute stroke, electrical epileptic activity occurs more frequently than previously suspected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Most studies assess the prevalence of hypertension in pediatric populations based on blood pressure (BP) readings taken on a single visit. We determined the prevalence of hypertension measured on up to three visits in a Swiss pediatric population and examined the association between hypertension and overweight and selected other factors. METHODS: Anthropometric data and BP were measured in all children of the sixth school grade of the Vaud canton (Switzerland) in 2005-2006. 'Elevated BP' was defined according to sex-specific, age-specific and height-specific US reference data. BP was measured on up to two additional visits in children with elevated BP. 'Hypertension' was defined as 'elevated BP' on all three visits. RESULTS: Out of 6873 children, 5207 (76%) participated [2621 boys, 2586 girls; mean (SD) age, 12.3 (0.5) years]. The prevalence of elevated BP was 11.4, 3.8 and 2.2% on first, second and thirds visits, respectively; hence 2.2% had hypertension. Among hypertensive children, 81% had isolated systolic hypertension. Hypertension was associated with excess body weight, elevated heart rate and parents' history of hypertension. Of the children, 16.1% of boys and 12.4% of girls were overweight or obese (CDC criteria, body mass index >or= 85th percentile). Thirty-seven percent of cases of hypertension could be attributed to overweight or obesity. CONCLUSIONS: The proportion of children with elevated BP based on one visit was five times higher than based on three measurements taken at few-week intervals. Our data re-emphasize the need for prevention and control of overweight in children to curb the global hypertension burden.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Patients with magnetic resonance (MR)-negative focal epilepsy (MRN-E) have less favorable surgical outcomes (between 40% and 70%) compared to those in whom an MRI lesion guides the site of surgical intervention (60-90%). Patients with extratemporal MRN-E have the worst outcome (around 50% chance of seizure freedom). We studied whether electroencephalography (EEG) source imaging (ESI) of interictal epileptic activity can contribute to the identification of the epileptic focus in patients with normal MRI. METHODS: We carried out ESI in 10 operated patients with nonlesional MRI and a postsurgical follow-up of at least 1 year. Five of the 10 patients had extratemporal lobe epilepsy. Evaluation comprised surface and intracranial EEG monitoring of ictal and interictal events, structural MRI, [(18)F]fluorodeoxyglucose positron emission tomography (FDG-PET), ictal and interictal perfusion single photon emission computed tomography (SPECT) scans. Eight of the 10 patients also underwent intracranial monitoring. RESULTS: ESI correctly localized the epileptic focus within the resection margins in 8 of 10 patients, 9 of whom experienced favorable postsurgical outcomes. DISCUSSION: The results highlight the diagnostic value of ESI and encourage broadening its application to patients with MRN-E. If the surface EEG contains fairly localized spikes, ESI contributes to the presurgical decision process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the evaluation results of the methods submitted to Challenge US: Biometric Measurements from Fetal Ultrasound Images, a segmentation challenge held at the IEEE International Symposium on Biomedical Imaging 2012. The challenge was set to compare and evaluate current fetal ultrasound image segmentation methods. It consisted of automatically segmenting fetal anatomical structures to measure standard obstetric biometric parameters, from 2D fetal ultrasound images taken on fetuses at different gestational ages (21 weeks, 28 weeks, and 33 weeks) and with varying image quality to reflect data encountered in real clinical environments. Four independent sub-challenges were proposed, according to the objects of interest measured in clinical practice: abdomen, head, femur, and whole fetus. Five teams participated in the head sub-challenge and two teams in the femur sub-challenge, including one team who tackled both. Nobody attempted the abdomen and whole fetus sub-challenges. The challenge goals were two-fold and the participants were asked to submit the segmentation results as well as the measurements derived from the segmented objects. Extensive quantitative (region-based, distance-based, and Bland-Altman measurements) and qualitative evaluation was performed to compare the results from a representative selection of current methods submitted to the challenge. Several experts (three for the head sub-challenge and two for the femur sub-challenge), with different degrees of expertise, manually delineated the objects of interest to define the ground truth used within the evaluation framework. For the head sub-challenge, several groups produced results that could be potentially used in clinical settings, with comparable performance to manual delineations. The femur sub-challenge had inferior performance to the head sub-challenge due to the fact that it is a harder segmentation problem and that the techniques presented relied more on the femur's appearance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PAH (N-(4-aminobenzoyl)glycin) clearance measurements have been used for 50 years in clinical research for the determination of renal plasma flow. The quantitation of PAH in plasma or urine is generally performed by colorimetric method after diazotation reaction but the measurements must be corrected for the unspecific residual response observed in blank plasma. We have developed a HPLC method to specifically determine PAH and its metabolite NAc-PAH using a gradient elution ion-pair reversed-phase chromatography with UV detection at 273 and 265 nm, respectively. The separations were performed at room temperature on a ChromCart (125 mmx4 mm I.D.) Nucleosil 100-5 microm C18AB cartridge column, using a gradient elution of MeOH-buffer pH 3.9 1:99-->15:85 over 15 min. The pH 3.9 buffered aqueous solution consisted in a mixture of 375 ml sodium citrate-citric acid solution (21.01 g citric acid and 8.0 g NaOH per liter), added up with 2.7 ml H3PO4 85%, 1.0 g of sodium heptanesulfonate and completed ad 1000 ml with ultrapure water. The N-acetyltransferase activity does not seem to notably affect PAH clearances, although NAc-PAH represents 10.2+/-2.7% of PAH excreted unchanged in 12 healthy subjects. The performance of the HPLC and the colorimetric method have been compared using urine and plasma samples collected from healthy volunteers. Good correlations (r=0.94 and 0.97, for plasma and urine, respectively) are found between the results obtained with both techniques. However, the colorimetric method gives higher concentrations of PAH in urine and lower concentrations in plasma than those determined by HPLC. Hence, both renal (ClR) and systemic (Cls) clearances are systematically higher (35.1 and 17.8%, respectively) with the colorimetric method. The fraction of PAH excreted by the kidney ClR/ClS calculated from HPLC data (n=143) is, as expected, always <1 (mean=0.73+/-0.11), whereas the colorimetric method gives a mean extraction ratio of 0.87+/-0.13 implying some unphysiological values (>1). In conclusion, HPLC not only enables the simultaneous quantitation of PAH and NAc-PAH, but may also provide more accurate and precise PAH clearance measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: In this study we investigated differences in the spatial recruitment of motor units (MUs) in the quadriceps when electrical stimulation is applied over the quadriceps belly versus the femoral nerve. METHODS: M-waves and mechanical twitches were evoked using over-the-quadriceps and femoral nerve stimulation of gradually increasing intensity from 22 young, healthy subjects. Spatial recruitment was investigated using recruitment curves of M-waves recorded from the vastus medialis (VM) and vastus lateralis (VL) and of twitches recorded from the quadriceps. RESULTS: At maximal stimulation intensity (Imax), no differences were found between nerve and over-the-quadriceps stimulation. At submaximal intensities, VL M-wave amplitude was higher for over-the-quadriceps stimulation at 40% Imax, and peak twitch force was greater for nerve stimulation at 60% and 80% Imax. CONCLUSIONS: For the VM, MU spatial recruitment during nerve and over-the-quadriceps stimulation of increasing intensity occurred in a similar manner, whereas significant differences were observed for the VL. Muscle Nerve, 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé: Dans le contexte d'un climat de plus en plus chaud, la localisation du pergélisol dans les terrains sédimentaires à forte déclivité et l'évaluation des mouvements de terrain qui y ont cours s'avèrent primordiales. S'insérant dans cette problématique, ce travail de thèse s'articule autour de deux axes de recherche différents. D'un point de vue statique, cette recherche propose une étude de la distribution et des caractéristiques du pergélisol dans les éboulis de la zone périglaciaire alpine. D'un point de vue dynamique, une analyse de l'influence des caractéristiques du pergélisol (teneur en glace, température du pergélisol, etc.) et des variations des températures de l'air et du sol sur les vitesses de fluage des corps sédimentaires gelés est effectuée. Afin de répondre à ce double objectif, l'approche "terrain" a été privilégiée. Pour déterminer la répartition et les caractéristiques du pergélisol, les méthodes traditionnelles de prospection du pergélisol ont été utilisées, à savoir la mesure de la température du sol à la base du manteau neigeux (BTS), la mesure de la température du sol en continu ainsi que la méthode géoélectrique. Les mouvements de terrain ont pour leur part été mesurés à l'aide d'un GPS différentiel. L'étude de la distribution du pergélisol a été effectuée dans une quinzaine d'éboulis situés dans les régions du Mont Gelé (Verbier-Nendaz) et d'Arolla principalement. Dans la plupart des cas, un pergélisol a pu être mis en évidence dans la partie inférieure des accumulations sédimentaires, alors que la partie médiane des éboulis n'est, le plus souvent, pas gelée. Si cette absence de pergélisol se prolonge parfois dans les portions sommitales des pentes, les mesures réalisées montrent que dans d'autres cas des sédiments gelés y sont à nouveau présents. Les résistivités électriques mesurées dans les portions gelées des éboulis étudiés sont dans la plupart des cas nettement inférieures à celles mesurées sur les glaciers rocheux. Des études préalables ont montré que des circulations d'air internes sont responsables de l'anomalie thermique négative et, lorsqu'il existe, du pergélisol que l'on trouve dans la partie inférieure d'éboulis situés plus de 1000 m plus bas que la limite inférieure régionale du pergélisol discontinu. L'étude de quatre sites de basse altitude (1400-1900 m), et notamment l'équipement du site de Dreveneuse (Préalpes Valaisannes) avec deux forages, des capteurs de température de surface et un anémomètre a permis de vérifier et de préciser le mécanisme de ventilation actif au sein des éboulis froids de basse altitude. Ce mécanisme fonctionne de la manière suivante: en hiver, l'air contenu dans l'éboulis, plus chaud et plus léger que l'air extérieur, monte à l'intérieur de l'accumulation sédimentaire et est expulsé dans ses parties sommitales. Cet effet de cheminée provoque une aspiration d'air froid à l'intérieur de la partie inférieure de l'éboulis, causant ainsi un sur-refroidissement marqué du terrain. En été, le mécanisme s'inverse, l'éboulis étant plus froid que l'air environnant. De l'air froid est alors expulsé au bas de la pente. Une ventilation ascendante hivernale a pu être mise en évidence dans certains des éboulis de haute altitude étudiés. Elle est probablement en grande partie responsable de la configuration particulière des zones gelées observées. Même si l'existence d'un effet de cheminée n'a pu être démontrée dans tous les cas, du fait notamment de la glace interstitielle qui entrave le cheminement de l'air, des indices laissant présager son possible fonctionnement existent dans la quasi totalité des éboulis étudiés. L'absence de pergélisol à des altitudes qui lui sont favorables pourrait en tous les cas s'expliquer par un réchauffement du terrain lié à des expulsions d'air relativement chaud. L'étude des mouvements de terrain a été effectuée sur une dizaine de sites, principalement sur des glaciers rocheux, mais également sur une moraine de poussée et - II - Résumé ? abstract quelques éboulis. Plusieurs glaciers rocheux présentent des formes de déstabilisation récente (niches d'arrachement, blocs basculés, apparition de la matrice fine à la surface, etc.), ce qui témoigne d'une récente accélération des vitesses de déplacement. Ce phénomène, qui semble général à l'échelle alpine, est probablement à mettre sur le compte du réchauffement du pergélisol depuis une vingtaine d'années. Les vitesses mesurées sur ces formations sont souvent plus élevées que les valeurs habituellement proposées dans la littérature. On note par ailleurs une forte variabilité inter-annuelle des vitesses, qui semblent dépendre de la variation de la température moyenne annuelle de surface. Abstract: In the context of a warmer climate, the localisation of permafrost in steep sedimentary terrain and the measurement of terrain movements that occur in these areas is of great importance. With respect to these problems, this PhD thesis follows two different research axes. From a static point of view, the research presents a study of the permafrost distribution and characteristics in the talus slopes of the alpine periglacial belt. From a dynamic point of view, an analysis of the influence of the permafrost characteristics (ice content, permafrost temperature, etc.) and air and soil temperature variations on the creep velocities of frozen sedimentary bodies is carried out. In order to attain this double objective, the "field" approach was favoured. To determine the distribution and the characteristics of permafrost, the traditional methods of permafrost prospecting were used, i.e. ground surface temperature measurements at the base of the snow cover (BTS), year-round ground temperature measurements and DC-resistivity prospecting. The terrain movements were measured using a differential GPS. The permafrost distribution study was carried out on 15 talus slopes located mainly in the Mont Gelé (Verbier-Nendaz) and Arolla areas (Swiss Alps). In most cases, permafrost was found in the lower part of the talus slope, whereas the medium part was free of ice. In some cases, the upper part of the talus is also free of permafrost, whereas in other cases permafrost is present. Electrical resistivities measured in the frozen parts of the studied talus are in most cases clearly lower than those measured on rock glaciers. Former studies have shown that internal air circulation is responsible for the negative thermal anomaly and, when it exists, the permafrost present in the lower part of talus slopes located more than 1000 m below the regional lower limit of discontinuous permafrost. The study of four low-altitude talus slopes (1400-1900 m), and notably the equipment of Dreveneuse field site (Valais Prealps) with two boreholes, surface temperature sensors and an anemometer permitted to verify and to detail the ventilation mechanism active in low altitude talus slopes. This mechanism works in the following way: in winter, the air contained in the block accumulation is warmer and lighter than the surrounding air and therefore moves upward in the talus and is expelled in its upper part. This chimney effect induces an aspiration of cold air in the interior of the lower part of talus, that causes a strong overcooling of the ground. In summer, the mechanism is reversed because the talus slope is colder than the surrounding air. Cold air is then expelled in the lower part of the slope. Evidence of ascending ventilation in wintertime could also be found in some of the studied high-altitude talus slopes. It is probably mainly responsible for the particular configuration of the observed frozen areas. Even if the existence of a chimney effect could not be demonstrated in all cases, notably because of interstitial ice that obstructs Résumé ? abstract - III - the air circulation, indices of its presence exist in nearly all the studied talus. The absence of permafrost at altitudes favourable to its presence could be explained, for example, by the terrain warming caused by expulsion of relatively warm air. Terrain movements were measured at about ten sites, mainly on rock glaciers, but also on a push moraine and some talus slopes. Field observations reveal that many rock glaciers display recent destabilization features (landslide scars, tilted blocks, presence of fine grained sediments at the surface, etc.) that indicate a probable recent acceleration of the creep velocities. This phenomenon, which seems to be widespread at the alpine scale, is probably linked to the permafrost warming during the last decades. The measured velocities are often higher than values usually proposed in the literature. In addition, strong inter-annual variations of the velocities were observed, which seems to depend on the mean annual ground temperature variations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'aquifère du Seeland représente une richesse en ressources hydriques qu'il est impératif de préserver contre tout risque de détérioration. Cet aquifère prolifique est constitué principalement de sédiments alluviaux post-glaciaires (graviers, sables et limons). Il est soumis aux contraintes environnementales des pratiques d'agriculture intensive, du réseau routier, des villes et de leurs activités industrielles. La connaissance optimale de ces ressources est donc primordiale pour leur protection. Dans cette optique, deux sites Kappelen et Grenchen représentatifs de l'aquifère du Seeland ont été étudiés. L'objectif de ce travail est de caractériser d'un point de vue hydrogéophysique l'aquifère au niveau de ces deux sites, c'est-à-dire, comprendre la dynamique des écoulements souterrains par l'application des méthodes électriques de surface associées aux diagraphies en intégrant des méthodes hydrogéologiques. Pour le site de Kappelen, les méthodes électriques de surface ont permis d'identifier les différents faciès géoélectriques en présence et de mettre en évidence leur disposition en une structure tabulaire et horizontale. Il s'agit d'un aquifère libre constitué d'une série de graviers allant jusqu'à 15 m de profondeur reposant sur de la moraine argileuse. Les diagraphies électriques, nucléaires et du fluide ont servis à la détermination des caractéristiques pétrophysiques et hydrauliques de l'aquifère qui contrôlent son comportement hydrodynamique. Les graviers aquifères de Kappelen présentent deux minéraux dominants: quartz et calcite. Les analyses minéralogiques indiquent que ces deux éléments constituent 65 à 75% de la matrice. La porosité totale obtenue par les diagraphies nucléaires varie de 20 à 30 %, et de 22 à 29 % par diagraphies électrique. Avec les faibles valeurs de Gamma Ray ces résultats indiquent que l'aquifère des graviers de Kappelen est dépourvu d'argile minéralogique. La perméabilité obtenue par diagraphies du fluide varie de 3.10-4 à 5.10-2 m/s, et par essais de pompage de 10-4 à 10-2 m/s. Les résultats des analyses granulométriques indiquent une hétérogénéité granulométrique au niveau des graviers aquifères. La fraction de sables, sables très fins, silts et limons constitue de 10 à 40 %. Ces éléments jouent un rôle important dans le comportement hydraulique de l'aquifère. La porosité efficace de 11 à 25% estimée à partir des résultats des analyses granulométriques suppose que les zones les plus perméables correspondent aux zones les plus graveleuses du site. Etablie sur le site de Kappelen, cette méthodologie a été utilisée sur le site de Grenchen. Les méthodes électriques de surface indiquent que l'aquifère captif de Grenchen est constitué des sables silteux comprenant des passages sableux, encadrés par des silts argileux imperméables. L'aquifère de Grenchen est disposé dans une structure relativement tabulaire et horizontale. Son épaisseur totale peut atteindre les 25 m vers le sud et le sud ouest ou les passages sableux sont les plus importants. La détermination des caractéristiques pétrophysiques et hydrauliques s'est faite à l'aide des diagraphies. Les intensités Gamma Ray varient de 30 à 100 cps, les plus fortes valeurs n'indiquent qu'une présence d'éléments argileux mais pas de bancs d'argile. Les porosités totales de 15 à 25% et les densités globales de 2.25 à 2.45 g/cm3 indiquent que la phase minérale (matrice) est composée essentiellement de quartz et de calcaire. Les densités de matrice varient entre 2.65 et 2.75 g/cm3. La perméabilité varie de 2 10-6 à 5 10-4 m/s. La surestimation des porosités totales à partir des diagraphies électriques de 25 à 42% est due à la présence d'argiles. -- The vast alluvial Seeland aquifer system in northwestern Switzerland is subjected to environmental challenges due to intensive agriculture, roads, cities and industrial activities. Optimal knowledge of the hydrological resources of this aquifer system is therefore important for their protection. Two representative sites, Kappelen and Grenchen, of the Seeland aquifer were investigated using surface-based geoelectric methods and geophysical borehole logging methods. By integrating of hydrogeological and hydrogeophysical methods, a reliable characterization of the aquifer system at these two sites can be performed in order to better understand the governing flow and transport process. At the Kappelen site, surface-based geoelectric methods allowed to identify various geoelectric facies and highlighted their tabular and horizontal structure. It is an unconfined aquifer made up of 15 m thick gravels with an important sandy fraction and bounded by a shaly glacial aquitard. Electrical and nuclear logging measurements allow for constraining the petrophysical and hydrological parameters of saturated gravels. Results indicate that in agreement with mineralogical analyses, matrix of the probed formations is dominated by quartz and calcite with densities of 2.65 and 2.71 g/cc, respectively. These two minerals constitute approximately 65 to 75 % of the mineral matrix. Matrix density values vary from 2.60 to 2.75 g/cc. Total porosity values obtained from nuclear logs range from 20 to 30 % and are consistent with those obtained from electrical logs ranging from 22 to 29 %. Together with the inherently low natural gamma radiation and the matrix density values obtained from other nuclear logging measurements, this indicates that at Kappelen site the aquifer is essentially devoid of clay. Hydraulic conductivity values obtained by the Dilution Technique vary between 3.10-4 and 5.10-2 m/s, while pumping tests give values ranging from 10-4 to 10-2 m/s. Grain size analysis of gravel samples collected from boreholes cores reveal significant granulometric heterogeneity of these deposits. Calculations based on these granulometric data have shown that the sand-, silt- and shale-sized fractions constitute between 10 and 40 % of the sample mass. The presence of these fine elements in general and their spatial distribution in particular are important as they largely control the distribution of the total and effective porosity as well as the hydraulic conductivity. Effective porosity values ranging from 11 to 25% estimated from grain size analyses indicate that the zones of higher hydraulic conductivity values correspond to the zones dominated by gravels. The methodology established at the Kappelen site was then applied to the Grenchen site. Results from surface-based geoelectric measurements indicate that it is a confined aquifer made up predominantly of shaly sands with intercalated sand lenses confined impermeable shally clay. The Grenchen confined aquifer has a relatively tabular and horizontal structure with a maximum thickness of 25 m in the south and the southwest with important sand passages. Petrophysical and hydrological characteristics were performed using electrical and nuclear logging. Natural gamma radiation values ranging from 30 to 100 cps indicate presence of a clay fraction but not of pure clay layers. Total porosity values obtained from electrical logs vary form 25 to 42%, whereas those obtained from nuclear logs values vary from 15 to 25%. This over-estimation confirms presences of clays. Density values obtained from nuclear logs varying from 2.25 to 2.45 g/cc in conjunction with the total porosity values indicate that the dominating matrix minerals are quartz and calcite. Matrix density values vary between 2.65 and 2.75 g/cc. Hydraulic conductivity values obtained by the Dilution Technique vary from 2 10-6 to 5 10-4 m/s.